An interventional study of Artificial intelligence augmented ultrasound in Developmental Dysplasia of Hip, sponsored by Murdoch Childrens Research Institute. Not yet recruiting. Per ClinicalTrials.gov, last updated 2026-10-07.

Sponsored by Murdoch Childrens Research Institute · Not applicable, Interventional, and Screening

Updated Oct 7, 2026Start date movedPrimary completion moved+1 moreGo to Updates ↓
Phase
Not applicable
Study type
Interventional
Enrollment
100
Allocation
Not applicable
Sex
All
01

Study summary

The goal of this trial is to pilot a portable ultrasound device that uses artificial intelligence to screen for hip dysplasia. Researchers will gather data to understand the feasibility of performing a larger trial in birthing hospitals. It will also seek to collect initial data on how well the scan compares to the standard hip screening performed soon after birth.

Participants will:

  • Have the portable ultrasound performed on their baby before they are discharged from hospital
  • Have a diagnostic ultrasound performed on their baby at 6-weeks of age
  • Complete a short questionnaire about the experience of having the measurement performed on their baby
Read the detailed description

A recent study by our team showed that at The Royal Women's Hospital, Melbourne, screening at birth using the standard combination of neonatal hip examination and risk-based referral for ultrasound failed to detect 52% (n=100) of cases of Developmental Dysplasia of the Hip (DDH) and that 98.5% (n=2,637) of infants undergoing a screening ultrasound, due to perceived increased risk, do not have DDH. Further, this research team replicated in a regional setting at University Hospital, Geelong in Victoria (n=1,207), that 55.6% of cases of DDH were missed, and of those sent for diagnostic ultrasound scans 92.5% did not have DDH (unpublished data). Together, this means many infants are being scanned, but an unacceptably high proportion of cases are still being missed.

Late detected dysplasia is often resistant to conservative treatment. This form of dysplasia is unpredictable in its presentation and may require surgical intervention to obtain a contained and stable joint. Such patients are at a higher risk of developing degenerative hip disease in early adult life and can suffer considerable disability, often failing to reach their full potential. Thus, many initiatives have been taken to improve our current screening programs, including clinical education programs, streamlined access, and incorporation of hip examinations into child health assessments. However, none of these initiatives has effectively reduced the rate of late detection of dysplasia. Despite selective screening protocols being in place, the incidence of late-diagnosed DDH has increased in South Australia, showing a significant rise from 0.22 per 1000 live births (1988-2003) to 0.77 per 1000 live births (2003-2009).

One part of the solution is optimising screening protocols for DDH in existing care models. A possible solution is utilising artificial intelligence to aid in screening decisions. One such new tool is the Exo Iris, a portable ultrasound device supported by real-time AI-augmented analysis to screen for hip dysplasia. Importantly, use of this device does not require extensive training and could be performed by midwives or paediatricians in standard neonate hip examinations. Initial work has shown that AI could successfully identify the standard plane, make measurements, and classify the hip as normal or abnormal. Scans are simple to conduct, add little time to the overall consultation and are non-invasive without the use of ionising radiation. Importantly, non-experts can easily be trained to use the technology; they are cost-effective and can be used in any clinical environment connected to a standard tablet.

Initial Canadian data suggests that DDH detection rates suggests that artificial intelligence (AI) analysis for hip dysplasia are on par with orthopaedic specialists. Of the infants flagged for follow-up there were 6 subsequently referred to specialist clinics after repeat scan and all were treated for DDH (5 harnessed, 1 surgical intervention). Of these the six infants detected, only two presented with well documented risk factors for increased risk of DDH (female sex, Indigenous, breech, family history), which may not have been detected without initial portable ultrasound screening.

Further to this, Retuve is a new open-source software tool that uses AI-analysis to measures standard indices on hip ultrasound images collected from any manufacturer's ultrasound probe, which can help users make hip screening decisions. This platform generates novel imaging parameters beyond current standards that may also be helpful in further understanding undetected late presentations. However, as this is a relatively new tool there has been little research to fully evaluate its performance and its potential utility as a screening tool.

There is clear scope for this technology to revolutionise screening in Australia by reducing the number of cases of DDH missed and the number of costly conventional ultrasound scans; however, there is limited data assessing the feasibility and accuracy of the new AI analysis strategies for DDH screening in the context of neonatal screening. To date, although the Exo Iris and embedded hip AI software is indicated for use in infants 0-6 months there is a dearth of data examining neonates, and no data exists evaluating it in the context of selective neonatal screening.

This study will provide foundational pilot evidence on the accuracy and feasibility of using the Exo Iris probe and an alternate AI software platform as part of standard neonatal screening. In addition to this, long-term follow-up as part of the VicHip parent study will aid in understanding potential parameters associated with missed presentations. To do this, 100 infants will be recruited from Monash Medical Centre, Victoria, Australia and will undergo both the AI-ultrasound scan that will be analysed both by the embedded software and Retuve and results from the AI analyses will be compared to a 6-week full diagnostic ultrasound.

02

Conditions studied

  • Developmental Dysplasia of Hip

Browse trials for

Keywords

  • hip dysplasia
  • artificial intelligence
  • screening
  • ultrasound
  • infant
03

In context

Hip Dislocation

107 studies on the registry are indexed under Hip Dislocation; 36 are open to participants now.

This study's planned enrollment of 100 is above the median of 86 across 64 interventional studies indexed under Hip Dislocation.

Browse Hip Dislocation studies →

Lead sponsor

Murdoch Childrens Research Institute is the lead sponsor of 99 studies on the registry; 34 are open to participants now.

Of its 5 completed or terminated interventional studies of FDA-regulated products, 3 (60%) have results posted.

Counted across the registry records on this site, refreshed daily.

04

Who can participate

Ages eligible
Child (0–17), Adult (18–64), Older adult (65+)
Sexes eligible
All
Accepts healthy volunteers
No

Go through the criteria one by one — yes, no or not sure — and take the list to your doctor or the study team. Kept in this browser only.

Inclusion criteria

  1. Enrolled in the Victorian Hip Dysplasia Registry (VicHip) study
  2. Infant born at term (≥37 weeks gestation)
  3. Infant and caregiver admitted to the post-natal ward
  4. Caregivers indicate they are willing to attend a 6-week ultrasound
  5. Caregivers can provide a signed and dated form and is a legally acceptable representative capable of understanding the informed consent document and providing consent on the infant's behalf.

Exclusion criteria

Exclusion Criteria:

  1. Any known congenital anomalies in the infant precluding examination of the hips
  2. Any known congenital neuromuscular conditions in the infant
Terms in these criteria, in plain language(1)

Underlined terms in the criteria open these too. Explained by clinicaltrials.gg, not part of the registry record. The study team decides who can take part.

Informed consent

Before you join, the study team explains what taking part involves — its purpose, what happens, the risks and possible benefits — and answers your questions, so you can decide freely. Consent is usually recorded on a form (the informed consent form, ICF) signed by you or, where the law allows, by someone legally authorised to decide for you.

You can keep asking questions during the study, you are told of new information that matters, and you can choose to leave at any time.

05

Study design

Phase
Not applicable
Primary purpose
Screening
Allocation
Not applicable
Intervention model
Single group
Masking
None (open label)
Enrollment
100 participants (estimated)

Study arms

  • Experimental
    All active participants

    All infants will undergo the AI-augmented ultrasound measure

    Device: Artificial intelligence augmented ultrasound

Interventions

  • DeviceArtificial intelligence augmented ultrasound

    The hip ultrasound is performed using a handheld device (Exo Iris) that is a pocket-sized ultrasound probe and is run through an application on an IoS (Apple mobile) operation system. A real-time algorithm detects and records the anatomical landmarks.

06

What researchers measure

Primary outcomes

  1. Feasibility of the AI-ultrasound method as determined by a study-specific questionnaire administered to care givers at Day 1

    Caregiver perspectives will be captured via a study-specific questionnaire administered at Day 1 and this will enable determination of the feasibility of the AI-ultrasound method.

    Time frame: Day 1

  2. Number of infants unable to be scanned with the AI ultrasound

    The proportion of infants unable to be successfully scanned with the AI-ultrasound will be calculated.

    Time frame: Day 1

  3. Reasons for failure to obtain AI ultrasound scan as determined by the performing research assistant

    The reasons why infants were unable to be scanned as determined by the research assistant performing the AI scan will be documented as follows: Unsettled baby, technical failure, body habitus or other.

    Time frame: Day 1

  4. Proportion of infants lost to follow-up between the AI-ultrasound and 6-week (corrected) diagnostic scan

    The proportion of infants that had an initial AI scan at Day 1 but did not return for a scan at Week 6 will be calculated.

    Time frame: Week 6

Secondary outcomes

  1. Specificity of AI-ultrasound device as determined by comparison of the geometric measures (femoral head coverage and alpha angle) and expert reviews between the Day 1 and Week 6 scans

    AI-ultrasound results will be compared to 6-week diagnostic ultrasound imaging to calculate specificity (\[number of true negative cases detected/(number of false positive cases detected + number of true negatives cases detected\] X 100). Hips will be classified according to the AI-recommendations, "unremarkable" i.e. no follow-up required or "follow-up recommended" to define negative and positive cases; those that receive an "unremarkable" classification will be defined as negative cases, and those that receive a "follow-up recommended" scan will be considered as positive cases for the reliability calculations. Diagnosis will be defined from the 6-week ultrasound scan and will be defined by both expert conclusion and geometric measures (femoral head coverage and alpha angle). Calculations will be performed at both the hip and individual level.

    Time frame: Day 1, Week 6

  2. Sensitivity of AI-ultrasound measure determined by comparison of the geometric measures (femoral head coverage and alpha angle) and expert reviews between the Day 1 and Week 6 scans

    AI-ultrasound results will be compared to 6-week diagnostic ultrasound imaging to calculate sensitivity (\[number of true positive cases detected/(number of true positive cases detected + number of false negative cases detected)\] X 100). Hips will be classified according to the AI-recommendations, "unremarkable" i.e. no follow-up required or "follow-up recommended" to define negative and positive cases; those that receive an "unremarkable" classification will be defined as negative cases, and those that receive a "follow-up recommended" scan will be considered as positive cases for the reliability calculations. Diagnosis will be defined from the 6-week ultrasound scan and will be defined by both expert conclusion and geometric measures (femoral head coverage and alpha angle). Calculations will be performed at both the hip and individual level.

    Time frame: Day 1, Week 6

  3. The correlation between the alpha angle degree as reported by the AI-ultrasound analysis and expert analysis of the 6-week diagnostic ultrasound scan

    Dependent on the distribution of the data Pearsons or Spearman's Rho correlation coefficients will be reported.

    Time frame: Day 1, Week 6

  4. The correlation between the percentage femoral head coverage as reported by the AI-ultrasound analysis and expert analysis of the 6-week diagnostic ultrasound scan

    Dependent on the distribution of the data Pearsons or Spearman's Rho correlation coefficients will be reported.

    Time frame: Day 1, Week 6

Other outcomes

  1. Difference in specificity of standard neonatal screening and the AI-ultrasound scan to discriminate for DDH

    The specificity of standard neonatal screening and the AI-ultrasound screening will be compared.

    Time frame: Day 1

  2. Difference in specificity of Retuve and the AI-ultrasound scan to discriminate for DDH

    The specificity of an alternate AI-analysis platform will be compared to the AI-ultrasound scan results.

    Time frame: Day 1

07

Study locations

No study locations are listed for this record.

08

References and documents

Publications

  • McArthur A, Wichuk S, Burnside S, et al. Retuve: Automated multi-modality analysis of hip dysplasia with open source AI. Software Impacts. 2025/10/01/ 2025;26:100791. doi:https://doi.org/10.1016/j.simpa.2025.100791
  • Jaremko JL, Hareendranathan A, Bolouri SES, Frey RF, Dulai S, Bailey AL. AI aided workflow for hip dysplasia screening using ultrasound in primary care clinics. Sci Rep. 2023 Jun 7;13(1):9224. doi: 10.1038/s41598-023-35603-9. PubMed 37286559 ↗
  • from 3D ultrasound using artificial intelligence: A two-center multi-year study. Informatics in Medicine Unlocked. 09/01 2022;33:101082. doi:10.1016/j.imu.2022.101082
  • Studer K, Williams N, Antoniou G, Gibson C, Scott H, Scheil WK, Foster BK, Cundy PJ. Increase in late diagnosed developmental dysplasia of the hip in South Australia: risk factors, proposed solutions. Med J Aust. 2016 Apr 4;204(6):240. doi: 10.5694/mja15.01082. PubMed 27031400 ↗
  • Johnson MD, Kuschel C, Donnan L. Neonatal clinical examination and selective ultrasound screening are not reliable for the early diagnosis of hip dysplasia: A retrospective cohort study. J Paediatr Child Health. 2023 Oct;59(10):1146-1151. doi: 10.1111/jpc.16472. Epub 2023 Aug 7. PubMed 37545325 ↗

Individual participant data

Plan to share: Yes — The de-identified data set collected for this analysis of this trial will be available 12 months after publication of the primary outcome. The study protocol and informed consent form will also be available.

Supporting information: Study protocol, Informed consent form

Time frame: 12 months after the publication of data until the data is deleted (at minimum 1 year after the youngest participant turns 25 years of age).

Access criteria: The data must be obtained from the Murdoch Children's Research Institute. Prior to releasing any data the following are required: a data access agreement must be signed between relevant parties, the Study Management Group must see and approve the data analysis plan describing how the data will be analysed, there must be an agreement around appropriate acknowledgment and any additional costs involved must be covered. Should the Study Management Group be unavailable, this role is delegated to the Murdoch Children's Research Institute. Data will only be shared with a recognized research organisation which has approved the proposed analysis plan.

09

Updates

1 registry update since Sep 25, 2026
Start date
Aug 2026→Dec 2026
Oct 7, 2026
Primary completion
Feb 2027→Jun 2027
Oct 7, 2026
Study completion
Mar 2027→Jun 2027
Oct 7, 2026
Show all 1 update
  1. Oct 7, 2026
    Start date Aug 2026→Dec 2026
    Primary completion Feb 2027→Jun 2027
    Study completion Mar 2027→Jun 2027
    + 1 other change: verification date

From the registry record's own update history. This site started tracking changes on Sep 25, 2026; for anything earlier, see the record history on ClinicalTrials.gov ↗

10

Registry details

Key details

Study ID
NCT07794644
Lead sponsor
Murdoch Childrens Research Institute
Collaborators
Monash Health, University of Alberta
Responsible party
Sponsor
First posted
Aug 31, 2026
Start date
Dec 2026 (estimated)
Primary completion
Jun 2027 (estimated)
Completion
Jun 2027 (estimated)
Last update
Oct 7, 2026

Study contacts

Brian Loh
Contact
brian.loh@rch.org.au
+61383416200
Natalie Hyde
Contact
natalie.hyde@mcri.edu.au
+61383416200
Brian Loh, MBBS BBiomedSc FRACS FAOrthoA
principal investigator · Murdoch Children's Research Institute & Monash Health

Oversight

Data monitoring committee
No
FDA-regulated drug
No
FDA-regulated device
Yes
View the source record on ClinicalTrials.gov ↗

Not currently enrolling

This study is not yet recruiting, as verified in Oct 2026. You cannot join it, but the record below documents what was studied.

Follow this study

Get an email when the registry record changes — status, dates, results — or when someone posts here.

Sign in to follow

Discussion

Questions and observations about this study, from anyone following it. Not medical advice, and not a channel to the study team — their contact details are on the registry record.

Sign in to join the discussion. Reading takes no account; posting does. You choose a display name, and a pseudonym is the default.

Nothing here yet. If you are running this trial, taking part in it, or weighing whether to, this is the place to say so.

Start the discussion