An interventional study of Stream™ Platform in User-Centered Design, Anastomotic Leak and Colorectal Surgery, sponsored by FluidAI Medical. Not yet recruiting at 1 site in Canada. Open to participants aged 18 Years and older. Per ClinicalTrials.gov, last updated 2025-02-28.
Sponsored by FluidAI Medical · Not applicable, Interventional, and Other
Help build ClinicalTrials.gg — short surveys, remote interviews or testing, in your language. Take part →
The study aims to demonstrate the potential for at-home monitoring using Stream™ Platform, through simulated-use testing. Lay users, defined as subjects or nonprofessional caregivers, will be asked to operate Stream™ Platform. Safety, efficacy, and usability data will be collected to ensure that users are able to comply with prescribed device use.
Additionally, clinical testing will be conducted to identify correlations between measurements from Stream™ Platform and standard laboratory, radiological, and clinical assessments used for leak detection as part of the current standard of care (SOC) that may be skipped if the subject is discharged early.
240 studies on the registry are indexed under Anastomotic Leak; 72 are open to participants now.
This study's planned enrollment of 25 is below the median of 140 across 128 interventional studies indexed under Anastomotic Leak.
Browse Anastomotic Leak studies →FluidAI Medical is the lead sponsor of 5 studies on the registry; 2 are open to participants now.
Counted across the registry records on this site, refreshed daily.
Go through the criteria one by one — yes, no or not sure — and take the list to your doctor or the study team. Kept in this browser only.
Exclusion Criteria:
Underlined terms in the criteria open these too. Explained by clinicaltrials.gg, not part of the registry record. The study team decides who can take part.
Before you join, the study team explains what taking part involves — its purpose, what happens, the risks and possible benefits — and answers your questions, so you can decide freely. Consent is usually recorded on a form (the informed consent form, ICF) signed by you or, where the law allows, by someone legally authorized to decide for you.
You can keep asking questions during the study, you are told of new information that matters, and you can choose to leave at any time.
Informed consent
Before you join, the study team explains what taking part involves — its purpose, what happens, the risks and possible benefits — and answers your questions, so you can decide freely. Consent is usually recorded on a form (the informed consent form, ICF) signed by you or, where the law allows, by someone legally authorized to decide for you.
You can keep asking questions during the study, you are told of new information that matters, and you can choose to leave at any time.
Explained by clinicaltrials.gg, not part of the registry record. The study team decides who can take part.
Stream™ Platform will be attached to the abdominal/pelvic drains of the patients enrolled in this group. The platform will conduct continuous pH and electrical conductivity measurements of the abdominal drain fluid. All subjects recruited will take part in the evaluation of Stream™ Platform in a simulated home-use environment.
Device: Stream™ Platform
Stream™ Platform consists of 5 main components: Origin™, Delta™ Monitor, Stream™ Application, Accessory Calibration Syringe(s), and Stream™ Cart. Origin™ is an inline biosensor system that can be attached between an off-the-shelf drainage catheter and evacuator bag/bulb system and is designed to monitor real-time changes in drained effluent characteristics (specifically pH and electrical conductivity (EC)) for the early identification of postoperative complications. Origin™ requires daily calibration (via Accessory Calibration Syringe(s)) for optimal performance and accuracy of its sensors. The Stream Application is a mobile application for displaying and analyzing data collected continuously via Origin™. Stream™ Application is pre-installed on Android mobile devices (called Delta™ Monitor) that are supplied by FluidAI. Origin connects to Stream Application via Bluetooth. Mobile carts/mounts, denoted Stream™ Carts/Delta Mounts, will be used to house the Delta™ Monitor.
Evaluate if lay users can operate Stream Platform safely and effectively under healthcare providers supervision (simulated home use)
1. Statistical evaluation of the number of calibration errors encountered due to lay user error as reported by the healthcare providers. 2. Statistical evaluation of the number of calibration errors due to lay user errors that required intervention by the supervising healthcare provider to protect subject health and safety. 3. Occurrence of device associated adverse events including: i. Adverse Device Events (ADE) ii. Serious Adverse Device Events (SADE) iii. Unanticipated Serious Adverse Device Events (USADE) iv. Device Deficiencies
Time frame: Through study completion, an average of 6-months
Evaluate lay users' satisfaction through user feedback survey
Subject reported overall satisfaction with daily calibrations and overall device. The following parameters will be recorded on a scale of 1-5: 1. System Related Feedback * Overall feedback on Stream Platform * Overall feedback on Stream Application 2. Training Related Feedback * Overall feedback on the instructions provided by Stream Application * Overall feedback on the training material provided including but not limited to training video, infographic, etc. * Overall feedback on the in-person training conducted 3. Subject Comfort Assessment * Overall subject experience performing ADLs (Activities of Daily Living) while Stream Platform is in use. * Overall subject experience sleeping while Stream Platform is in use
Time frame: Through study completion, an average of 6-months
Utilize continuous pH and EC measurements collected prospectively using Stream™ Platform to supplement FluidAI's existing clinical model for early prediction of leakage after colorectal surgery.
Data collected will be used to supplement Stream™ Platform's existing clinical model for early prediction of leakage.
Time frame: Through study completion, an average of 6-months
Identify correlations between measurements from Stream™ Platform and current standard of care (SOC).
Assess if any strong correlations exist between pH/EC measurement collected using FluidAI's Stream™ Platform and other diagnostic biomarkers for AL
Time frame: Through study completion, an average of 6-months
Estimate the time taken by lay users to conduct calibration procedures
Quantify the average time taken by subjects/caregiver to conduct calibration in seconds as measured by the Stream™ Platform
Time frame: Through study completion, an average of 6-months
Plan to share: No
No publications or documents are linked to this record.
Start is estimated for Mar 2025; primary completion for Jul 2025, 4 months later.
Of 66 interventional studies with no phase under Anastomotic Leak, half reached primary completion within 32 months of starting (the median), counting those still running; a quarter within 19 and three quarters within 42. This study's planned 4 months is below that.
How these figures are worked out, and which studies are left out of them.
This study is not yet recruiting, as verified in Feb 2025. You cannot join it, but the record below documents what was studied.
Get an email when the registry record changes — status, dates, results — or when someone posts here.
Sign in to followQuestions and observations about this study, from anyone following it. Not medical advice, and not a channel to the study team — their contact details are on the registry record.
Sign in to join the discussion. Reading takes no account; posting does. You choose a display name, and a pseudonym is the default.
Nothing here yet. If you are running this trial, taking part in it, or weighing whether to, this is the place to say so.
FluidAI Medical