An interventional study of Hybrid Closed-loop Insulin Delivery System and Insulin pump in Diabetes Mellitus, sponsored by Huazhong University of Science and Technology. Completed at 1 site in China. Open to participants aged 18 Years to 75 Years. Per ClinicalTrials.gov, last updated 2025-05-23.
Sponsored by Huazhong University of Science and Technology · Not applicable, Interventional, and Treatment
Perioperative management of glucose levels remains challenging. The purpose of the study is to compare the hybrid closed-loop insulin delivery system with the standard insulin therapy ( insulin pump with CGM, insulin dose controlled by physicians) in controlling glucose levels among patients in the perioperative period.
Hyperglycemia is particularly frequent in the perioperative period, which leads to metabolic and functional disorders, aggravates organ damage, induces various complications, and increases the risk of postoperative infection and even death.
However, glucose level management among perioperative patients remains challenging because of the frequent blood glucose monitoring requirement and insulin adjustment to accommodate the physiological changes of patients before surgery.
In this study, we planned to use an open-source, hybrid closed-loop insulin delivery system and common insulin pump combined with CGM for short-term intensive insulin therapy in patients with diabetes during the perioperative period. To comprehensively evaluate the clinical efficacy and safety of the hybrid closed-loop insulin delivery system, we planned to compare the blood glucose control and other clinical indicators such as postoperative complications of patients with different intensive insulin therapy regimens If the participant is enrolled before the surgery, the following procedure will be followed:
Preoperative: the participants wear the open-source AP system for treatment.
Intraoperative: participants should discontinue the insulin pump in advance, with the specific timing determined by the endocrinologist. The CGM can remain in place as long as it does not interfere with the surgery.
Postoperative: After the subject returns to the ward, the nurse will reinstall the open-source AP system, and the treatment will continue for at least 3-4 days.
Huazhong University of Science and Technology is the lead sponsor of 241 studies on the registry; 60 are open to participants now.
Counted across the registry records on this site, refreshed daily.
1)18\~75 years old (including 18 years old and 75 years old),
2)Perioperative patients with need diabetes including type 2 diabetes mellitus and other special types of diabetes mellitus and need insulin therapy;
3)Fasting blood glucose ≥7.0mmol/L or random blood glucose 11.1≥mmol/L;
4)Patients signed the informed consent form and volunteered to participate in the clinical trial.
5 ) Patients who have already undergone surgery and are still hospitalized during the perioperative period with poor glycemic control.
Exclusion Criteria:
After patients signed the informed consent form in the ward, the nurse installed the insulin pump and the subcutaneous, real-time, continuous glucose monitor (CGM). The insulin pump was installed in the abdomen or upper arm, and the CGM was installed in the upper arm. A Hybrid closed-loop insulin delivery system with an open-source algorithm was set up for participants by the clinical trial investigators. The algorithm was initialized with the participant's weight and basal insulin requirements. The control algorithm modulated insulin delivery every 5 min based on the CGM glucose level, anticipated glucose trends, and patient-specific information such as the basal rate profile to guarantee blood glucose control within the target range. The perioperative patients in the hybrid closed-loop insulin delivery group who were admitted to the hospital received 3-5 days of glucose-lowering therapy.
Device: Hybrid Closed-loop Insulin Delivery System
The insulin treatment with a pump and CGM was applied according to the local clinical guidelines. The insulin pump was installed in the abdomen or upper arm, and the CGM was inserted in the upper arm by the investigator. Doctors adjust the insulin dose according to the patient's glucose level.
Device: Insulin pump
The Hybrid Closed-loop Insulin Delivery System system consisted of a Medtronic pump, a continuous glucose monitoring system(SIBIONICS®)and an open-source algorithm integrated into the phone. Insulin pump therapy group consisted of a Medtronic pump, and a continuous glucose monitoring system(SIBIONICS®). The difference between the two groups is that the artificial pancreas system automatically regulates the basal rate to maintain blood glucose in a target range.
Participants used conventional insulin pumps to control blood glucose, At the same time, a continuous glucose monitoring system was used to monitor glucose changes. Health care providers adjust the insulin dose of patients according to their blood glucose level.
TIR
time in range
Time frame: 5-10days
TAR
time above range
Time frame: 5-10days
TBR
time blow range
Time frame: 5-10days
MBG
mean blood glucose
Time frame: 5-10days
postoperative infection
rate of postoperative infection in the perioperative period
Time frame: 5-10days
Plan to share: No
No publications or documents are linked to this record.
This study is completed, as verified in May 2025. You cannot join it, but the record below documents what was studied.
Get an email when the registry record changes — status, dates, results — or when someone posts here.
Sign in to followQuestions and observations about this study, from anyone following it. Not medical advice, and not a channel to the study team — their contact details are on the registry record.
Sign in to join the discussion. Reading takes no account; posting does. You choose a display name, and a pseudonym is the default.
Nothing here yet. If you are running this trial, taking part in it, or weighing whether to, this is the place to say so.
Huazhong University of Science and Technology