ClinicalTrials.gg
Status unknownNCT06147583Updated Dec 14, 2023

Assessing Detection Algorithms for Insulin Pump Malfunctions in Type 1 Diabetes

An interventional study of Simulation of an insulin pump failure in Diabetes Mellitus, Type I, sponsored by University of Padova. Status unknown at 1 site in Italy. Open to participants aged 18 Years to 70 Years. Per ClinicalTrials.gov, last updated 2023-12-14.

Sponsored by University of Padova · Not applicable, Interventional, and Supportive care

The sponsor has not verified this record recently (last verified Dec 2023), so the status shown — last known as Not yet recruiting — may be out of date.
Phase
Not applicable
Study type
Interventional
Enrollment
20
Allocation
Not applicable
Ages
18 Years to 70 Years
Sex
All
01

Study summary

The goal of this clinical trial is to test the effectiveness of fault-detection algorithms in detecting malfunctioning of the insulin infusion system in an artificial pancreas (also known as Automated Insulin Delivery system) for type 1 diabetes.

The main questions it aims to answer is:

"Are the proposed algorithms effective in detecting insulin suspension?" Effectiveness accounts for both high sensitivity (i.e. the fraction of suspension correctly detected) and low false alarm rate.

The study has three phases:

  • free-living artificial pancreas data collection,
  • in-patient induction of hyperglycemia (mimicking an insulin pump malfunction),
  • retrospective analysis of the collected data to evaluate the effectiveness of the proposed algorithms in detecting insulin suspension.
Read the detailed description

In individuals with type 1 diabetes, adjusting insulin doses to accommodate the ever-changing conditions of daily life is crucial for achieving satisfactory metabolic control. To address this challenge, researchers have developed an Automated Insulin Delivery (AID) system, commonly known as an artificial pancreas. This system comprises of an insulin pump, a continuous glucose monitoring (CGM) sensor, and a sophisticated control algorithm. The algorithm uses CGM data to calculate the insulin dose required to maintain good glycemic control, and it automatically commands the insulin infusion.

However, artificial pancreas systems can experience malfunctions, some of which are highly risky. The most dangerous malfunctions include insulin pump failures and infusion set occlusions, which lead to prolonged interruptions in insulin delivery. This exposes the patient to the risk of hyperglycemia and, even more dangerously, ketoacidosis, a severe complication that can result in hospitalization and, in severe cases, death. Unfortunately, patients do not always notice these issues in a timely manner.

This study aims to test new algorithms for detecting pump/infusion set malfunctions that result in reduced or interrupted insulin delivery. The study consists of three phases:

  • Phase 1: Preliminary Data Collection (Free-living Data) In this phase, data related to glycemic trends and insulin administration in free-living conditions are collected. This data is obtained from a download form the patient's artificial pancreas. The one-month session is designed to gather a substantial amount of patient-specific data to enable the algorithms to learn how insulin and meals impact the patient's glycemia as recorded by the CGM sensor. During this phase, the patient continues to use their artificial pancreas in their daily life.
  • Phase 2: Induction of Hyperglycemia The second phase involves the patient visiting the clinic, where, according to a specific protocol and a defined schedule, insulin infusion is temporarily suspended to simulate a pump malfunction. The resulting episode of hyperglycemia is closely monitored under medical supervision. At the end of the experiment, the study team assists the patient in restoring euglycemia before returning home.
  • Phase 3: Retrospective Data Analysis In this phase, the collected data is retrospectively analyzed to evaluate the effectiveness of the proposed algorithms in detecting insulin suspension, simulating a pump malfunction. The sensitivity of the tested methods is assessed as the fraction of insulin suspensions (simulating a malfunction) correctly detected.

The uniqueness of this dataset lies in the controlled induction of malfunction, achieved by disconnecting the insulin pump and monitoring the resulting hyperglycemic episode. The presence of malfunctions in this data is certain and precisely characterized in terms of the start time and duration. The dataset resulting from this experimentation will be a valuable tool for the scientific community, enabling the retrospective testing of fault detection algorithms.

02

Conditions studied

  • Diabetes Mellitus, Type I
03

In context

Diabetes Mellitus, Type 1

3,614 studies on the registry are indexed under Diabetes Mellitus, Type 1; 586 are open to participants now.

This study's planned enrollment of 20 is below the median of 40 across 2,718 interventional studies indexed under Diabetes Mellitus, Type 1.

Browse Diabetes Mellitus, Type 1 studies →

Lead sponsor

University of Padova is the lead sponsor of 214 studies on the registry; 41 are open to participants now.

Counted across the registry records on this site, refreshed daily.

04

Who can participate

Ages eligible
18 Years to 70 Years
Sexes eligible
All
Accepts healthy volunteers
No

Go through the criteria one by one — yes, no or not sure — and take the list to your doctor or the study team. Kept in this browser only.

Inclusion criteria

  • Age between 18 (included) and 70 years
  • At least 1 year from the diagnosis of type 1 diabetes mellitus
  • Body mass index (BMI) less than 30 kg/m²
  • Treated with automated insulin delivery system (AID) for at least 3 months
  • Using carbohydrate counting to calculate meal bolus
  • Glycated hemoglobin \< 10%
  • If treated with antihypertensive, thyroid, antidepressant or lipid-lowering drugs, the therapy must be stable for at least 1 month before enrolment and remain stable for the entire duration of the study
  • Awareness of the study design and purpose
  • Willingness to undergo the study procedures
  • Signing the informed consent

Exclusion criteria

Exclusion Criteria:

  • Pregnancy or breastfeeding; pregnancy planning (effective contraception is required in women of childbearing age)
  • Hematocrit less than 36% in females and less than 38% in males
  • Presence of ischemic heart disease or congestive heart failure or history of a cerebrovascular event
  • Therapy with a drug that significantly affects glucose metabolism (e.g. steroids)
  • Uncontrolled hypertension
  • Allergy or adverse reaction to insulin
  • Known adrenal problems, pancreatic cancer, or insulinoma
  • Any comorbid condition affecting glucose metabolism as judged by the investigator
  • Current alcohol abuse, substance abuse, or serious mental illness, as judged by the investigator
  • Unstable proliferative retinopathy according to fundus examination within the last year
  • Known hemorrhagic diathesis or dyscrasia
  • Blood donation in the last 3 months
  • Renal failure with creatinine > 150 μmol/L
  • Impaired hepatic function based on plasma AST/ALT levels > 2 times the upper limits of normal values
05

Study design

Phase
Not applicable
Primary purpose
Supportive care
Allocation
Not applicable
Intervention model
Single group
Masking
None (open label)
Enrollment
20 participants (estimated)

Study arms

  • Experimental
    Insulin pump fault simulation

    Collection of patients data during outpatient use of AID (automated insulin delivery); Inpatient simulation of insulin pump faults by suspension of insulin administration.

    Other: Simulation of an insulin pump failure

Interventions

  • OtherSimulation of an insulin pump failure

    The intervention will consist in simulating an insulin pump failure by suspending insulin infusion and monitoring the consequent hyperglycemia.

06

What researchers measure

Primary outcomes

  1. Sensitivity

    Fraction of correctly detected insulin suspension in the population

    Time frame: During the intervention (during the inpatient insulin suspension to simulate a pump fault)

Secondary outcomes

  1. False positive per day

    Number of false alarms (normalized by the number of days of monitoring)

    Time frame: Baseline pre-intervention (during the outpatient data collection)

07

Study locations

1 site
08

References and documents

Publications

  • Meneghetti L, Dassau E, Doyle FJ 3rd, Del Favero S. Machine Learning-Based Anomaly Detection Algorithms to Alert Patients Using Sensor Augmented Pump of Infusion Site Failures. J Diabetes Sci Technol. 2022 May;16(3):641-648. doi: 10.1177/1932296821997854. Epub 2021 Mar 9. PubMed 33686873 ↗
  • Meneghetti L, Facchinetti A, Favero SD. Model-Based Detection and Classification of Insulin Pump Faults and Missed Meal Announcements in Artificial Pancreas Systems for Type 1 Diabetes Therapy. IEEE Trans Biomed Eng. 2021 Jan;68(1):170-180. doi: 10.1109/TBME.2020.3004270. Epub 2020 Dec 21. PubMed 32746034 ↗
  • Meneghetti L, Susto GA, Del Favero S. Detection of Insulin Pump Malfunctioning to Improve Safety in Artificial Pancreas Using Unsupervised Algorithms. J Diabetes Sci Technol. 2019 Nov;13(6):1065-1076. doi: 10.1177/1932296819881452. Epub 2019 Oct 14. PubMed 31608660 ↗
  • Facchinetti A, Del Favero S, Sparacino G, Cobelli C. An online failure detection method of the glucose sensor-insulin pump system: improved overnight safety of type-1 diabetic subjects. IEEE Trans Biomed Eng. 2013 Feb;60(2):406-16. doi: 10.1109/TBME.2012.2227256. Epub 2012 Nov 15. PubMed 23193300 ↗

Individual participant data

Plan to share: No

09

Timeline

Tracking since Sep 25, 2026
ElapsedEstimatedEstimated, not yet reachedSimilar studies: half by the dot; the band is the middle halfHalf of similar studies reached it by the dot; the band is the middle half, from a quarter to three quarters

Start is estimated for Dec 2023; primary completion for Feb 2024, 2 months later.

Of 821 non-industry interventional studies with no phase under Diabetes Mellitus, Type 1, half reached primary completion within 19 months of starting (the median), counting those still running; a quarter within 9 and three quarters within 37. This study's planned 2 months is below that.

Counting every sponsor, half of 921 studies reached it within 18 months; a quarter within 9 and three quarters within 35.

How these figures are worked out, and which studies are left out of them.

Registered
Nov 15, 2023
First posted
Nov 27, 2023
StartEst.
Dec 2023
Primary completionEst.
Feb 2024
CompletionEst.
Apr 2024
Last update
Dec 14, 2023
What these dates mean
Start.
When the first participant enrolled; while estimated, when the study expects to open to recruitment.
Primary completion.
When the last participant was examined or treated to collect data for the study's main question, its primary outcome. A study that stopped early gives the date its data collection stopped.
Completion.
When the last participant's last visit took place, for every outcome, secondary ones and side effects included: the end of the study. Often later than primary completion, sometimes the same day.
Actual and Est.
Actual means the registry says the date has happened. Est. (estimated) is a date the sponsor plans or expects. It can still move, and the sponsor is expected to change it to actual once it has passed.
No changes since tracking began. The registry record was last updated on Dec 14, 2023, before this site started recording changes on Sep 25, 2026. Its history is on ClinicalTrials.gov ↗
10

Registry details

Key details

Study ID
NCT06147583
Collaborators
Azienda Ospedaliera di Padova
Responsible party
Daniela Bruttomesso (Principal Investigator and Medical Doctor, University of Padova) — Principal investigator
First posted
Nov 27, 2023
Start date
Dec 2023 (estimated)
Primary completion
Feb 2024 (estimated)
Completion
Apr 2024 (estimated)
Last update
Dec 14, 2023

Study contacts

Daniela Bruttomesso, MD, Phd
Contact
daniela.bruttomesso@unipd.it
0498212183
Federico Boscari, MD, Phd
Contact
federico.boscari@gmail.com
0498212180

Oversight

Data monitoring committee
No
FDA-regulated drug
No
FDA-regulated device
No
View the source record on ClinicalTrials.gov ↗

Not currently enrolling

This study is status unknown, as verified in Dec 2023. You cannot join it, but the record below documents what was studied.

Follow this study

Get an email when the registry record changes — status, dates, results — or when someone posts here.

Sign in to follow

Discussion

Questions and observations about this study, from anyone following it. Not medical advice, and not a channel to the study team — their contact details are on the registry record.

Sign in to join the discussion. Reading takes no account; posting does. You choose a display name, and a pseudonym is the default.

Nothing here yet. If you are running this trial, taking part in it, or weighing whether to, this is the place to say so.

Start the discussion