An interventional study of Apnea test under high-flow oxygenation in Brain Death, sponsored by Centre Hospitalier Régional d'Orléans. Completed at 1 site in France. Open to participants aged 18 Years and older. Per ClinicalTrials.gov, last updated 2024-08-02.
Sponsored by Centre Hospitalier Régional d'Orléans · Not applicable, Interventional, and Diagnostic
Brain death is a clinical and paraclinical diagnosis established in a known etiological context. It involves the irreversible destruction of cerebral functions in a beating-heart individual.
In the context of organ and tissue donation from a critically ill patient, the clinical diagnosis of brain death is confirmed through a mandatory apnea test. This test is conducted by disconnecting the patient from the ventilator for a duration of 8 to 10 minutes. The test is considered validated when there is no spontaneous respiratory movement and the presence of hypercapnia. Hypercapnia is defined as a PaCO2 (carbon dioxide partial pressure) greater than 60 mmHg or an increase of more than 20 mmHg compared to the pre-ventilator disconnection capnia. These thresholds are meant to provide a strong stimulus to the respiratory centers, objectively confirming the absence of spontaneous ventilation.
In practice, the apnea test is performed under CPAP (Continuous Positive Airway Pressure) or by administering oxygen at 6-10L/min through the endotracheal tube.
High-flow oxygenation could be a simple alternative for the apnea test during the validation of the clinical diagnosis of brain death while reducing the risk of lung derecruitment and compromising organ viability and/or lung donation.
However, due to the high gas flow used (60 L/min), high-flow oxygenation can lead to a "washout" effect in the anatomical dead space, which may lower the carbon dioxide partial pressure. Consequently, even in a patient in a state of brain death, where spontaneous ventilation is absent by definition, it is not certain that the carbon dioxide partial pressure will increase to the threshold of 60 mmHg or more than 20 mmHg in 10 minutes during an apnea test conducted with high-flow oxygenation.
The purpose of this study is, therefore, to examine the feasibility of clinically diagnosing brain death through an apnea test performed with high-flow oxygenation.
To determine whether the validation criterion which involves observing an arterial capnia > 60 mmHg or an increase > 20 mmHg (compared to the capnia at the beginning of the test) after 10 minutes can be achieved during an apnea test conducted under high-flow oxygen therapy in patients with clinically confirmed brain death by standard apnea test (under standard oxygen therapy)
The protocol is based on performing two consecutive apnea tests on a patient in clinical brain death in intensive care unit. The first apnea test will be conducted under standard oxygen therapy and confirms clinical brain death (standard procedure). The second apnea test (for the study) will be conducted under high-flow oxygen therapy. Only patients whose apnea test is initially validated under standard oxygen therapy will have the second apnea test under high-flow oxygen therapy.
After a standardized preoxygenation, the 1st apnea test will be performed under standard oxygen therapy through the endotracheal tube (flow at 8L/min) for 10 minutes. An arterial blood gas sampling will be sampled every 2 minutes during the1st apnea test.
The confirmation of clinical brain death by validating the apnea test under standard oxygen therapy will be done if the following two conditions are met: 1) absence of a spontaneous respiratory movements AND 2) an arterial capnia > 60 mmHg or an increase > 20 mmHg (compared to the capnia at the end of preoxygenation).
Then the patient will be reconnected to the ventilator for 15 minutes. A second standardized preoxygenation will be performed before the 2nd apnea test. The second apnea test will be performed under high-flow oxygen therapy through the endotracheal tube (flow at 50L/min, FiO2 100%) for 10 minutes. An arterial blood gas sampling will be sampled every 2 minutes during the1st apnea test.
Then the patient will be reconnected to the ventilator with the same settings before the start of the study.
75 studies on the registry are indexed under Brain Death; 9 are open to participants now.
This study's enrollment of 15 is below the median of 46 across 38 interventional studies indexed under Brain Death.
Browse Brain Death studies →Centre Hospitalier Régional d'Orléans is the lead sponsor of 132 studies on the registry; 32 are open to participants now.
Counted across the registry records on this site, refreshed daily.
Go through the criteria one by one — yes, no or not sure — and take the list to your doctor or the study team. Kept in this browser only.
Exclusion Criteria:
The protocol is based on performing two consecutive apnea tests on a patient in clinical brain death in intensive care unit. The first apnea test will be conducted under standard oxygen therapy and confirms clinical brain death (standard procedure). The second apnea test (for the study) will be conducted under high-flow oxygen therapy. Only patients whose apnea test is initially validated under standard oxygen therapy will have the second apnea test under high-flow oxygen therapy.
Diagnostic Test: Apnea test under high-flow oxygenation
Apnea test under high-flow oxygenation in patients with a confirmed clinical brain death by a standard apnea test (under standard oxygen therapy)
Percentage of patients exceeding the hypercapnia threshold
Percentage of patients exceeding the hypercapnia threshold after an apnea test conducted under high-flow oxygen therapy among patients who have already been validated for the apnea test under standard oxygen therapy.
Time frame: 48 hours
Time required after ventilator disconnection to exceed 60mmHg of PaCO2 or for which PaCO2 increases by more than 20mmHg compared to the PaCO2 before disconnection.
Determine the maximum PaCO2 value reached by all included subjects at the 10-minute mark of the apnea test with high-flow oxygen therapy
Time frame: 48 hours
Recording of PaO2 and PaCO2 values measured in 2-minute intervals during the standard apnea test and apnea test under high-flow oxygen therapy.
Time frame: 48 hours
Recording of the PaO2/FiO2 ratio before and after each apnea test.
Time frame: 48 hours
Recording of systolic blood pressure, measured every minute during the two apnea tests
Describe the evolution of hemodynamic parameters during the standard apnea test and the apnea test with high-flow oxygen therapy
Time frame: 48 hours
Recording of diastolic blood pressure, measured every minute during the two apnea tests
Describe the evolution of hemodynamic parameters during the standard apnea test and the apnea test with high-flow oxygen therapy
Time frame: 48 hours
Recording of heart rate,measured every minute during the two apnea tests
Describe the evolution of hemodynamic parameters during the standard apnea test and the apnea test with high-flow oxygen therapy
Time frame: 48 hours
Recording of pulse oximetry, measured every minute during the two apnea tests
Describe the evolution of hemodynamic parameters during the standard apnea test and the apnea test with high-flow oxygen therapy
Time frame: 48 hours
This study is completed, as verified in Aug 2024. You cannot join it, but the record below documents what was studied.
Get an email when the registry record changes — status, dates, results — or when someone posts here.
Sign in to followQuestions and observations about this study, from anyone following it. Not medical advice, and not a channel to the study team — their contact details are on the registry record.
Sign in to join the discussion. Reading takes no account; posting does. You choose a display name, and a pseudonym is the default.
Nothing here yet. If you are running this trial, taking part in it, or weighing whether to, this is the place to say so.
Centre Hospitalier Régional d'Orléans →