An interventional study of EOS in Femoroacetabular Impingement and Hip Dysplasia, sponsored by Sheffield Children's NHS Foundation Trust. Not yet recruiting. Open to participants aged 13 Years to 50 Years. Per ClinicalTrials.gov, last updated 2023-06-27.
Sponsored by Sheffield Children's NHS Foundation Trust · Not applicable, Interventional, and Diagnostic
The orientation of the femoral neck in relation to the coronal or transcondylar axis of the distal femur is known as the femoral version. It is categorised as femoral anteversion when the femoral neck axis is anteriorly rotated in relation to transcondylar axis, while femoral head axis is anterior in relation to the femur coronal plane; or femoral retroversion when the femoral head-neck axis points are posterior to the femoral coronal plane.
Some studies suggest that conventional radiography cannot adequately measure femoral version, and should be avoided in favour of more precise methods using computed tomography (CT) scanning. CT imaging is currently the reference method for measuring femoral version. However, its clinical use is limited by issues such as high levels of radiation exposure, which can adversely affect patients, especially children. Magnetic resonance imaging (MRI) is considered an alternative for measuring femoral version; however, it is expensive, time consuming and subject to motion artifacts. The associated costs and risks of MRI increase when anaesthesia is needed for the examination. The EOS imaging system could provide an alternative to the previously mentioned techniques. It uses lower doses of irradiation and the sterEOS software allows the production of 3D images.
This study aims to compare the accuracy of the EOS imaging system with CT for the measurement of hip parameters in individuals aged 13 years and older. In addition, this study aims to correlate EOS and CT parameters with gait analysis and compare the ability of EOS and CT to predict gait abnormalities.
The average range of anteversion at birth is from 30 to 40 degrees. These values reduce with growth, remaining in the10 to 15-degree range for most adults. Nevertheless, these values can be significantly different between populations or contralateral sides. Altered femoral version can affect the normal function and even stability of the hip and knee joints, so that it must be considered in the clinical assessment of cases involving femoral fractures, torsional alignment, slipped capital femoral epiphysis and Legg-Calve-Perthes disease. Femoral version can be evaluated by clinical investigation or radiographic assessment.
Imaging examinations play an important role in the evaluation of femoral version prior to surgical interventions. However, some studies suggest that conventional radiography cannot adequately measure femoral version. CT imaging is currently the reference method for measuring femoral version. However, its clinical use is limited by issues such as high levels of radiation exposure, which can adversely affect patients, especially children. Magnetic resonance imaging (MRI) is considered an alternative for measuring femoral version; however, it is expensive, time consuming and subject to motion artifacts. The associated costs and risks increase when anaesthesia is needed for the examination. The EOS imaging system provides an alternative to the previously mentioned techniques. It uses lower doses of irradiation and the sterEOS software allows the production of 3D images. The EOS system can measure the torsional alignment of the lower limbs with 4 to 30 times less irradiation than a CT scan. Prior studies measuring femoral version using both EOS and CT have found a high correlation between the results of these techniques.
Acetabular morphology and 3D orientation are important factors to be considered prior to orthopaedic surgery. Acetabular orientation is known to vary between genders as women have more anteverted acetabula than men, as well as a larger inclination angle. For hip preservation surgery, the most promising technique for the treatment of dysplasia in adolescents and young adults is peri-acetabular osteotomy (PAO). The benefits of PAO in the treatment of hip joint pathology are discussed in more detail and have been assessed either morphologically using MRI or functionally, by performing post-operative gait analysis.
The EOS imaging system with 3D sterEOS software can produce 3D reconstructions of the acetabulum with 30-fold lower irradiation of patients compared to CT and 10-fold lower irradiation compared to chest radiographs. The innovation behind the EOS system earned its inventor a Nobel prize in physics (particle detection). This modality simultaneously captures biplanar radiographs (anteroposterior and lateral images) through the whole-body slot scanning with patients in standing position with ultralow irradiation. 3D reconstructions of the individual skeleton can be performed from these captured radiographs using sterEOS software. 2D and 3D EOS skeletal images are produced with similar volume and size to 1:1 scale, so that vertebral and spinal angles and lengths of lower limbs and other variable parameters can be measured accurately. The advantage is that sterEOS 3D reconstructions can be useful for evaluating rotational disorders of joints and lower limbs horizontally. The EOS system can acquire 3D information of individuals in standing, sitting and squatting positions.
The EOS system has the advantage of allowing for 3D reconstructions of hip/pelvic parameters with lower irradiation than CT scans. This allows for the identification of underlying deformities while exposing patients to lower radiation dose. It would seem that the EOS system has potential to replace CT as the investigation of choice for assessing hip morphology.
116 studies on the registry are indexed under Femoracetabular Impingement; 37 are open to participants now.
This study's planned enrollment of 20 is below the median of 73 across 70 interventional studies indexed under Femoracetabular Impingement.
Browse Femoracetabular Impingement studies →Sheffield Children's NHS Foundation Trust is the lead sponsor of 53 studies on the registry; 10 are open to participants now.
Counted across the registry records on this site, refreshed daily.
Go through the criteria one by one — yes, no or not sure — and take the list to your doctor or the study team. Kept in this browser only.
Exclusion Criteria:
Participants will undergo CT and EOS imaging pre- and post- operatively. The EOS is being compared to the reference method CT scan.
Device: EOS
This modality simultaneously captures biplanar radiographs (anteroposterior and lateral images) through the whole-body slot scanning with patients in standing position with ultralow irradiation
Diagnostic accuracy of EOS
Diagnostic accuracy of the EOS imaging system compared to CT for measuring native hip/pelvic parameters in individuals aged 13 years and older
Time frame: 18 months
Inter- and intraobserver reliability of EOS
Inter- and intraobserver reliability of the EOS imaging system compared to CT for measuring native hip/pelvic parameters in individuals aged 13 years and older
Time frame: 18 months
Predictive power of EOS
Correlation of pre- and post-operative hip measurements from EOS and CT to predict disturbances in gait and quality of life at 6 and 18 months post-operative
Time frame: 18 months
No study locations are listed for this record.
Plan to share: No
No publications or documents are linked to this record.
This study is not yet recruiting, as verified in Jun 2023. You cannot join it, but the record below documents what was studied.
Get an email when the registry record changes — status, dates, results — or when someone posts here.
Sign in to followQuestions and observations about this study, from anyone following it. Not medical advice, and not a channel to the study team — their contact details are on the registry record.
Sign in to join the discussion. Reading takes no account; posting does. You choose a display name, and a pseudonym is the default.
Nothing here yet. If you are running this trial, taking part in it, or weighing whether to, this is the place to say so.
Sheffield Children's NHS Foundation Trust