CClinicalTrials.gg
Not yet recruitingNCT05881876Updated May 31, 2023

Determining the Reliability and Validity of a New Method for Measuring Upper Extremity Joint Range of Motion in Burn Patients Using a Tracking System

An observational study in Contracture Joint, sponsored by Hangang Sacred Heart Hospital. Not yet recruiting. Open to participants aged 18 Years to 75 Years. Per ClinicalTrials.gov, last updated 2023-05-31.

Sponsored by Hangang Sacred Heart Hospital · Observational

Study type
Observational
Model
Other
Time perspective
Prospective
Enrollment
50
Ages
18 Years to 75 Years
Sex
All
01

Study summary

In burn patients, joint contracture is a common complication caused by hypertrophic scars, necessitating accurate evaluation and diagnosis of the degree of disability and functional deterioration. A standard goniometer based on the American Medical Association (AMA) guidelines for measuring joint range of motion (ROM) is the gold standard for evaluating musculoskeletal diseases. However, the handheld goniometer is highly dependent on the skill and experience of the measurer. Recently, a marker-based system for accurate ROM measurement has been demonstrated in clinical evaluation. This study investigated the reliability and validity of the marker-based system for evaluation of joint ROM in burn patients.

Inclusion criteria were as follows: male or female patients between 18 and 75 years of age, partial or full-thickness burns that healed spontaneously or required skin grafting, and limited joint ROM in the upper extremities caused by burns. Exclusion criteria were limited joint ROM due to severe osteoarthritis or rheumatoid arthritis, congenital defects, structural disease, amputation, central or peripheral nervous system injuries, difficulty in voluntary decision-making due to cognitive impairment, or a history of orthopaedic surgery due to fracture.

The experimentals tried to compare the validity and reliability of a marker-based system and AMA methods for the burn patient with joint contracture of upper extremities.

Read the detailed description

In burn patients, joint contracture is a common complication caused by hypertrophic scars, necessitating accurate evaluation and diagnosis of the degree of disability and functional deterioration. A standard goniometer based on the American Medical Association (AMA) guidelines for measuring joint range of motion (ROM) is the gold standard for evaluating musculoskeletal diseases. However, the handheld goniometer is highly dependent on the skill and experience of the measurer. Recently, a marker-based system for accurate ROM measurement has been demonstrated in clinical evaluation. This study investigated the reliability and validity of the marker-based system for evaluation of joint ROM in burn patients.

After three familiarisation trials for ROM measurement, the evaluation procedure was initiated on the participant's dominant side. A standard goniometer was used to measure ROM and increments were marked. The measurement position was the same as that used in the standard Korean range of motion protocol (KRSP). One examiner measured aROM for flexion, extension, abduction, adduction, external rotation, and internal rotation at a neutral position using a stainless-steel goniometer (JAMAR Co., Pakistan). The aROM was measured under the instruction that the subjects should move their arms as far as possible.

For ROM evaluation in upper extremities, 22 reflective markers were attached to the patient's body before measurement and markers were tracked using eight infrared cameras. Prior to the test, a static calibration test was performed in a neutral position. A skeleton model was obtained directly from the Motive2.1 (the unified software platform of OptiTrack®) for the data gathered by the OptiTrack® system (NaturalPoint, Inc., Corvallis, OR, USA). The ROM of the shoulder, elbow, and wrist was measured sequentially using a dynamic view. The marker trajectories allowed estimation of the joint centres and definition. The joint centres were calculated from optical motion capture data, according to the definitions of Visual3D (C-Motion, Inc., Germantown, MD, USA), a widely used software tool for 3D biomechanical research.

After evaluating the ROM of the upper extremity joint using a goniometer and optical motion capture system (session 1), re-measurement was performed 2 days later (session 2). Markers were positioned by the same observer in both sessions for all the participants.

All statistical analyses were performed using SPSS version 23 (IBM Corp., Armonk, NY, USA). The mean ROM and standard deviation were calculated. An independent t-test was used to compare inter-method differences. For intra-rater reliability, two tests were compared for each measurement. Relative reliability was assessed using the intraclass correlation coefficient (ICC) and ICC interpretation was based on the Fleiss guidelines. Statistical significance was set as P \< 0.05.

02

Conditions studied

  • Contracture Joint

Browse trials for

03

Who can participate

Ages eligible
18 Years to 75 Years
Sexes eligible
All
Accepts healthy volunteers
No
Sampling method
Probability sample

Study population

who had developed joint contractures in the shoulder, elbow or wrist due to hypertrophic scars after thermal injury were enrolled in this study

Inclusion criteria

  • male or female patients
  • ages between 18 and 75 years of age
  • partial or full-thickness burns that healed spontaneously or required skin grafting
  • limited joint ROM in the upper extremities caused by burns.

Exclusion criteria

Exclusion Criteria:

  • limited joint ROM due to severe osteoarthritis or rheumatoid arthritis
  • congenital defects, structural disease, amputation
  • central or peripheral nervous system injuries
  • difficulty in voluntary decision-making due to cognitive impairment
  • a history of orthopaedic surgery due to fracture.
04

Study design

Observational model
Other
Time perspective
Prospective
Enrollment
50 participants (estimated)
Target follow-up
2 Days
Patient registry
Yes

Groups and cohorts

  • burn groups

    Inclusion criteria were as follows: male or female patients between 18 and 75 years of age, partial or full-thickness burns that healed spontaneously or required skin grafting, and limited joint ROM in the upper extremities caused by burns.

05

What researchers measure

Primary outcomes

  1. range of motion of joint

    For ROM evaluation in upper extremities, 22 reflective markers were attached to the patient's body before measurement and markers were tracked using eight infrared cameras. Prior to the test, a static calibration test was performed in a neutral position. A skeleton model was obtained directly from the Motive2.1 (the unified software platform of OptiTrack®) for the data gathered by the OptiTrack® system (NaturalPoint, Inc., Corvallis, OR, USA).The ROM of the shoulder, elbow, and wrist was measured sequentially using a dynamic view. The marker trajectories allowed estimation of the joint centres and definition (Figure 1). The joint centres were calculated from optical motion capture data, according to the definitions of Visual3D (C-Motion, Inc., Germantown, MD, USA), a widely used software tool for 3D biomechanical research .

    Time frame: 2 days

Secondary outcomes

  1. AMA evaluation

    A standard goniometer was used to measure ROM and increments were marked. The measurement position was the same as that used in the standard Korean range of motion protocol (KRSP). One examiner measured aROM for flexion, extension, abduction, adduction, external rotation, and internal rotation at a neutral position using a stainless-steel goniometer (JAMAR Co., Pakistan). The aROM was measured under the instruction that the subjects should move their arms as far as possible.

    Time frame: 2 days

06

Study locations

No study locations are listed for this record.

07

References and documents

Publications

  • Schouten HJ, Nieuwenhuis MK, van Baar ME, van der Schans CP, Niemeijer AS, van Zuijlen PPM. The degree of joint range of motion limitations after burn injuries during recovery. Burns. 2022 Mar;48(2):309-318. doi: 10.1016/j.burns.2021.01.003. Epub 2021 Jan 22. PubMed 34955294 ↗
  • Ahn SY, Ko H, Yoon JO, Cho SU, Park JH, Cho KH. Determining the Reliability of a New Method for Measuring Joint Range of Motion Through a Randomized Controlled Trial. Ann Rehabil Med. 2019 Dec;43(6):707-719. doi: 10.5535/arm.2019.43.6.707. Epub 2019 Dec 31. PubMed 31918533 ↗

Individual participant data

Plan to share: No

08

Registry details

Key details

Study ID
NCT05881876
Lead sponsor
Hangang Sacred Heart Hospital
Responsible party
So Young Joo (Hangang Sacred Heart Hospital, Hangang Sacred Heart Hospital) — Principal investigator
First posted
May 31, 2023
Start date
Jun 15, 2023 (estimated)
Primary completion
Dec 25, 2023 (estimated)
Completion
Dec 31, 2023 (estimated)
Last update
May 31, 2023

Study contacts

Seongeun Baek/Hangang Sacred Heart Hospital IRB
Contact
tjddms1108@hallym.or.kr
82-2-2639-5900

Oversight

Data monitoring committee
Yes
FDA-regulated drug
No
FDA-regulated device
No
View the source record on ClinicalTrials.gov ↗

Not currently enrolling

This study is not yet recruiting, as verified in May 2023. You cannot join it, but the record below documents what was studied.

Follow this study

Get an email when the registry record changes — status, dates, results — or when someone posts here.

Sign in to follow

Discussion

Questions and observations about this study, from anyone following it. Not medical advice, and not a channel to the study team — their contact details are on the registry record.

Sign in to join the discussion. Reading takes no account; posting does. You choose a display name, and a pseudonym is the default.

Nothing here yet. If you are running this trial, taking part in it, or weighing whether to, this is the place to say so.

Start the discussion