An interventional study of Normothermic machine perfusion and Hypothermic machine perfusion in Kidney Transplantation, sponsored by Zhang Tianyu. Not yet recruiting at 1 site in China. Open to participants aged 18 Years and older. Per ClinicalTrials.gov, last updated 2023-02-24.
Sponsored by Zhang Tianyu · Not applicable, Interventional, and Treatment
Due to the rising incidence of renal failure and the improvement of organ transplantation technology, the shortage of donor organs has become one of the main problems limiting the development of kidney transplantation. Marginal donor is one of the important ways to extend the donor pool. Normothermic mechanical perfusion (NMP) is a new generation of organ preservation technology, which can maintain the blood supply and at the same time evaluate the marginal kidney function during the organ preservation. However, the clinical effect has not been proved. Hypothermic Machine Perfusion (HMP) is the mainstream organ perfusion technology. This study aims to compare the effectiveness of NMP with the HMP.
The main purpose of the study is to improve the utilization rate of marginal donors through normothermic perfusion, and reduce the incidence of infection, severe rejection and even graft failure caused by implantation of marginal donors. This study aims at the following aspects:
A single-center prospective randomized controlled study was used to compare the prognosis of renal transplantation between 50 patients with normothermic pulse perfusion and 50 patients with hypothermic mechanical perfusion who were enrolled in our hospital for allograft kidney transplantation.
Assessment factors:
The expanded standard donors (ECD) were obtained
Exclusion Criteria:
After organ acquisition, the donor kidney was trimmed, and then the donor kidney was connected to the cryoperfusion machine (lifeport, which has been used in routine clinical practice in our hospital) for continuous low temperature mechanical perfusion (\<8 ℃). The perfusion solution was extracted for proteomic study at 10 min after perfusion and at the end of perfusion.
Device: Hypothermic machine perfusion
After conventional UW perfusion is obtained, the marginal donor kidney is immediately perfused without ischemia at normal temperature. The perfusion time is at least 4 hours (so as to repair the marginal donor kidney). The perfusion solution is as above, and the perfusion solution is loaded into the device authorized in Europe (XVIVO - KidneyAssist ®), Connect the transplanted renal artery with the device. Take 5ml perfusion solution in advance before perfusion, 5ml perfusion solution every 30min after perfusion, take perfusion solution at the end of perfusion (blood gas analysis for each perfusion solution, and finally perfusion solution for culture), and measure urine volume every hour. After perfusion, the transplanted kidney was disconnected from the perfusion device, and the donor kidney was perfused again with 2L HTK solution, followed by routine transplantation.
Device: Normothermic machine perfusion
XVIVO (perfusion company, Gothenburg, Sweden), functions to be included in perfusion equipment, cardiopulmonary bypass machine and neonatal cardiopulmonary bypass machine, including polyethylene pipeline, heating equipment (perfusion temperature 37 ℃), venous pool (venous pressure is 0 mmHg, adjust the height of perfusion pool), centrifugal pump (arterial pressure is set at initial 75 mmHg, maintain 65 mmHg). The perfusion solution contains 215ml of dextran/albumin solution and 400ml of hematocrit, 2ml of 10% calcium gluconate, 1300u/L heparin and 400mg of cefazolin sodium. The oxygen/carbon dioxide ratio is (95%/5%, 2L/min) for continuous perfusion, and pO2 is maintained at 650mmHg during perfusion. During perfusion, continue to use verapamil, amino acid, glucose and insulin. Lactic acid Ringer solution (10ml/h) was used to supplement the lost circulation volume due to urine production during perfusion.
LifePort Kidney Transporter is designed to integrate with the clinical environment by using readily available supplies, requiring minimal user intervention, and by being easy to use. LifePort Kidney Transporter is a portable, isolated kidney perfusion and transport system, designed to support a donated kidney and to maintain the organ in a near-normal physiologic state under hypothermic aseptic conditions. An insulated plastic housing encloses the kidney and perfusate within a LifePort Kidney Transporter Disposable Perfusion Circuit. LifePort Kidney Transporter components include an Ice Container, Pump Deck, Control Panel, Outer Display, Bubble Detectors, External Connections Panel, sensors, and four lithium-ion batteries. Two handles make the unit easy to lift and carry
Rate of delayed renal function (DGF)
At least one dialysis is required within one week after kidney transplantation
Time frame: 1 week after surgery
Estimated glomerular filtration rate
Calculated from serum creatinine levels to assess kidney function.
Time frame: 3, 6, 12 months after surgery
Rate of primary non-function (PNF)
Dialysis is required because the transplanted kidney is nonfunctional
Time frame: 1 months after surgery
Graft survival and recipient survival
Incidence of the Graft survival and recipient survival
Time frame: 1 year follow-up
Complications
incidence of complications
Time frame: within 90 days after operation
Patient death
Death date after surgery and the reasons
Time frame: 1 year follow-up
Hospitalization expenses
Total expenses of kidney transplantation
Time frame: 3, 6, 12 months after surgery
Plan to share: Yes — All collected IPD, all IPD that underlie results in a publication
Supporting information: Study protocol, Icf, Csr
This study is not yet recruiting, as verified in Feb 2023. You cannot join it, but the record below documents what was studied.
Get an email when the registry record changes — status, dates, results — or when someone posts here.
Sign in to followQuestions and observations about this study, from anyone following it. Not medical advice, and not a channel to the study team — their contact details are on the registry record.
Sign in to join the discussion. Reading takes no account; posting does. You choose a display name, and a pseudonym is the default.
Nothing here yet. If you are running this trial, taking part in it, or weighing whether to, this is the place to say so.