ClinicalTrials.gg
CompletedNCT05718947ULTIMSUpdated Sep 19, 2024

Ultra-high-field Brain MRI in Multiple Sclerosis

An observational study in Multiple Sclerosis, sponsored by Zuyderland Medisch Centrum. Completed at 1 site in Netherlands. Open to participants aged 18 Years to 65 Years. Per ClinicalTrials.gov, last updated 2024-09-19.

Sponsored by Zuyderland Medisch Centrum · Observational

Study type
Observational
Model
Cohort
Time perspective
Prospective
Enrollment
10
Ages
18 Years to 65 Years
Sex
All
01

Study summary

The MRI scan is one of the most important tools for diagnosing multiple sclerosis (MS) and for monitoring disease progression and medication effects. Increasingly strong MRI magnets (higher field strength) enable us to see abnormalities in the brain in greater detail. On the other hand, it poses challenges because these higher field strength MRIs are more sensitive to disturbances, for example due to motion, including physiological motion such as breathing and swallowing. In current practice, field strengths of up to 3 Tesla are common. The aim of this study is to compare scanning at field strengths of 3 Tesla in 10 MS patients at two different moments (baseline and 6 months) with scanning at field strengths that are higher, namely 7 and 9.4 Tesla, in order to identify the advantages and disadvantages. With the further development of this technique, the investigators may be able to make a better diagnosis in the future and detect subtle changes in the course of the disease more quickly in order to optimize treatments.

Read the detailed description

Multiple sclerosis (MS) is the most common demyelinating disease of the central nervous system. MRI has a prominent role in diagnosing and monitoring disease and treatment and is most suitable tool to study MS pathology in vivo. In recent years there has been research has been much research on the use of 7 tesla MRI in MS. There is a better signal and contrast allowing for higher resolutions. This may contribute to, among other things, higher sensitivity for detecting MS abnormalities, not only in the white matter but also in the gray matter. Furthermore, there is probably also a better specificity. This is due to the improved visualization of MS specific pathological features such as the presence of a central vein in a lesion and paramagnetic rings.

In this pilot study, the investigators study whether going beyond the field strength of 7 Tesla (7T) has additional benefits in characterizing MS lesions and to also map the limitations and challenges of scanning above 7T. More specifically, first, whether scanning above 7T might improve sensitivity to white and gray matter abnormalities in MS. Second, whether MS specific pathology, such as the central veins and the paramagnetic rings, are better visualized at the higher compared to lower field strengths. To this end, the investigators want to scan 10 relapsing-remitting MS patients for clinical field strength (3T) and also ultra-high field strengths (7T and 9.4T) at two time points (baseline and after 6 months).

If it can demonstrate through this pilot study that scanning at field strengths above 7T can benefit detection of lesions or certain pathological features, the use of this research tool can help us in future studies to better understand MS.

02

Conditions studied

  • Multiple Sclerosis

Browse trials for

Keywords

  • Multiple Sclerosis
  • MRI
  • Ultra-high field
03

In context

Multiple Sclerosis

3,524 studies on the registry are indexed under Multiple Sclerosis; 668 are open to participants now.

This study's enrollment of 10 is below the median of 100 across 1,034 observational studies indexed under Multiple Sclerosis.

Browse Multiple Sclerosis studies →

Lead sponsor

Zuyderland Medisch Centrum is the lead sponsor of 64 studies on the registry; 15 are open to participants now.

Counted across the registry records on this site, refreshed daily.

04

Who can participate

Ages eligible
18 Years to 65 Years
Sexes eligible
All
Accepts healthy volunteers
No
Sampling method
Non-probability sample

Study population

The investigators aim to include 10 patients from our outpatient clinic, with a known clinical diagnosis of relapsing remitting MS according to the 2017 McDonald criteria between ages of 18-65 years, who had a new lesion on their clinical brain MRI in the prior 15 months. The intention is to include patients on low-efficacy medication (interferon β, peginterferon, glatiramer acetate, teriflunomide) as well as patients on high-efficacy medication (natalizumab, ocrelizumab, alemtuzumab, fingolimod) to have a varied and representative study population. The investigators estimate it highly realistic that inclusion of these 10 patients can be achieved.

Go through the criteria one by one — yes, no or not sure — and take the list to your doctor or the study team. Kept in this browser only.

Inclusion criteria

  • Relapsing remitting MS patients (according to the 2017 McDonald criteria)
  • Age 18-65 years
  • New brain MRI lesion in the past 15 months.

Exclusion criteria

Exclusion Criteria:

  • Non-compatible implanted material/devices
  • Not being able to lie flat long enough (for the MRI) because of another medical condition
05

Study design

Observational model
Cohort
Time perspective
Prospective
Enrollment
10 participants (actual)
Patient registry
No

Groups and cohorts

  • MS scan cohort

    10 patients with a known clinical diagnosis of relapsing remitting MS according to the 2017 McDonald criteria between ages of 18-65 years, who had a new lesion on their clinical brain MRI in the prior 15 months. The investigators intend to include patients on low-efficacy medication (interferon β, peginterferon, glatiramer acetate, teriflunomide) as well as patients on high-efficacy medication (natalizumab, ocrelizumab, alemtuzumab, fingolimod) to have a varied and representative study population.

    Diagnostic Test: Brain MRI (3T, 7T, 9.4T)

Interventions

  • Diagnostic testBrain MRI (3T, 7T, 9.4T)

    All patients will undergo anatomical brain imaging on a 3T, 7T and 9.4T MRI scanner within the same day at baseline and again 6 months later. An optimized protocol for every separate field strength will be run. Sequences will include at least T1-weighted, T2\*-weighted and a T2 SPACE or FLAIR sequence. No intravenous contrast will be used.

06

What researchers measure

Primary outcomes

  1. Detected white- and grey-matter lesions

    Given that the present study is a pilot, descriptive statistics will be employed to identify important trends between field strengths, evaluating the number of lesions that can be identified in white as well as grey matter, in what proportion of lesions a perivenous localization can be identified

    Time frame: 6 months

Secondary outcomes

  1. Image quality parameters (signal-to-noise and contrast-to-noise ratios)

    Time frame: 6 months

07

Study locations

1 site
  • Zuyderland MC
    Geleen, Limburg 6162BG, Netherlands
08

References and documents

Publications

  • Ceccarelli A, Bakshi R, Neema M. MRI in multiple sclerosis: a review of the current literature. Curr Opin Neurol. 2012 Aug;25(4):402-9. doi: 10.1097/WCO.0b013e328354f63f. PubMed 22691759 ↗
  • Bruschi N, Boffa G, Inglese M. Ultra-high-field 7-T MRI in multiple sclerosis and other demyelinating diseases: from pathology to clinical practice. Eur Radiol Exp. 2020 Oct 22;4(1):59. doi: 10.1186/s41747-020-00186-x. PubMed 33089380 ↗
  • Sati P. Diagnosis of multiple sclerosis through the lens of ultra-high-field MRI. J Magn Reson. 2018 Jun;291:101-109. doi: 10.1016/j.jmr.2018.01.022. Epub 2018 Apr 26. PubMed 29705032 ↗
  • Trattnig S, Bogner W, Gruber S, Szomolanyi P, Juras V, Robinson S, Zbyn S, Haneder S. Clinical applications at ultrahigh field (7 T). Where does it make the difference? NMR Biomed. 2016 Sep;29(9):1316-34. doi: 10.1002/nbm.3272. Epub 2015 Mar 12. PubMed 25762432 ↗
  • van der Kolk AG, Hendrikse J, Zwanenburg JJ, Visser F, Luijten PR. Clinical applications of 7 T MRI in the brain. Eur J Radiol. 2013 May;82(5):708-18. doi: 10.1016/j.ejrad.2011.07.007. Epub 2011 Sep 19. PubMed 21937178 ↗
  • Tallantyre EC, Morgan PS, Dixon JE, Al-Radaideh A, Brookes MJ, Evangelou N, Morris PG. A comparison of 3T and 7T in the detection of small parenchymal veins within MS lesions. Invest Radiol. 2009 Sep;44(9):491-4. doi: 10.1097/RLI.0b013e3181b4c144. PubMed 19652606 ↗
  • Absinta M, Sati P, Schindler M, Leibovitch EC, Ohayon J, Wu T, Meani A, Filippi M, Jacobson S, Cortese IC, Reich DS. Persistent 7-tesla phase rim predicts poor outcome in new multiple sclerosis patient lesions. J Clin Invest. 2016 Jul 1;126(7):2597-609. doi: 10.1172/JCI86198. Epub 2016 Jun 6. PubMed 27270171 ↗
09

Updates

Tracking since Sep 25, 2026
No changes since tracking began. The registry record was last updated on Sep 19, 2024, before this site started recording changes on Sep 25, 2026. Its history is on ClinicalTrials.gov ↗
10

Registry details

Key details

Study ID
NCT05718947
Lead sponsor
Zuyderland Medisch Centrum
Collaborators
Scannexus
Responsible party
Sponsor
First posted
Feb 8, 2023
Start date
Sep 12, 2023
Primary completion
Jun 17, 2024
Completion
Jun 17, 2024
Last update
Sep 19, 2024

Oversight

Data monitoring committee
No
FDA-regulated drug
No
FDA-regulated device
No
View the source record on ClinicalTrials.gov ↗

Not currently enrolling

This study is completed, as verified in Sep 2024. You cannot join it, but the record below documents what was studied.

Follow this study

Get an email when the registry record changes — status, dates, results — or when someone posts here.

Sign in to follow

Discussion

Questions and observations about this study, from anyone following it. Not medical advice, and not a channel to the study team — their contact details are on the registry record.

Sign in to join the discussion. Reading takes no account; posting does. You choose a display name, and a pseudonym is the default.

Nothing here yet. If you are running this trial, taking part in it, or weighing whether to, this is the place to say so.

Start the discussion