An interventional study of high-flow oxygen therapy device for Severe pneumonia patients with artificial airway and AIRVOTM2 device for Severe pneumonia patients with artificial airway in Pneumonia, sponsored by Shenzhen Second People's Hospital. Not yet recruiting at 1 site in China. Open to participants aged 18 Years and older. Per ClinicalTrials.gov, last updated 2022-07-19.
Sponsored by Shenzhen Second People's Hospital · Not applicable, Interventional, and Supportive care
Help build ClinicalTrials.gg — short surveys, remote interviews or testing, in your language. Take part →
Among 142 studies in Pneumonia with a site in China — 44 open to participants now, 48 under way, 2 of them phase 3. Pneumonia · China.
Among the 142 studies in Pneumonia with a site in China, this one is the 47th largest by planned enrollment of the 94 interventional ones that give a count, is one of 10 that started in 2022, is one of 36 with no phase, reaches primary completion later than 2 of the 47 other live ones, and was the 75th registered.
1,569 studies on the registry are indexed under Pneumonia; 266 are open to participants now.
Browse Pneumonia studies →44 of the 142 studies in Pneumonia with a site in China are open now. Recruiting first, the newest first:
Shandong University · Sites in China
Ages 65–110
Beijing Continent Pharmaceutical Co, Ltd. · Sites in China
Ages 18–75
Zhongnan Hospital · Sites in China
Ages 18+
Beijing Tiantan Hospital · Sites in China
Ages 18–80
Chongqing Medical University · Sites in China
Ages 18+
A study can be open while its sites in China have not opened yet or have stopped. Only those recruiting at a site in China →
Of the 158 Pneumonia studies recruiting now, 84 (53%) set no upper age limit and 47 (30%) stop at 75 or younger; 40 take children under 18; 22 take healthy volunteers.
This study: 18 Years and older · all sexes · no healthy volunteers.
The full table on the hub →This tab as a report to print or save as PDF → With an account.
142 studies; the count open now beside each. This study's row is marked.
A study in two phases is counted once above. Listed by phase, each with its combined phases: Phase 1 15 · Phase 2 17 · Phase 3 21 · Phase 4 14
First in 2003; this study’s year is marked. 10 started in 2022.
By drug class, each counting the studies that test any of its medicines:
This study's planned enrollment of 156 is above the median of 128 across 978 interventional studies indexed under Pneumonia.
Median enrollment 154 across the 94 interventional studies, 350 across the 48 observational. Of the 51 that completed or were terminated, 3 (6%) have results posted.
This tab as a report to print or save as PDF → With an account.
25 of 142 have an industry lead sponsor. The 10 most frequent:
Shenzhen Second People's Hospital is the lead sponsor of 51 studies on the registry; 8 are open to participants now.
Shenzhen Second People's Hospital has 1 study filed under Pneumonia — fewer than ten, so there is no comparison to draw.
11 of the studies in Pneumonia with a site in China that are under way reach primary completion within a year, 2 of them phase 3. Phase 3 first, then by date:
| Study | Primary completion |
|---|---|
| NCT07388680Phase 3Beijing Continent Pharmaceutical Co, Ltd.Pirfenidone Capsules in the Treatment of Radiation-induced Lung Injury With or Without Immune Pneumonia | 2026-12-30 |
| NCT06679140Phase 3PfizerA Study to Learn About a Study Medicine Called Ibuzatrelvir in Adult and Adolescent Patients With COVID-19 Who Are Not Hospitalized But Are at Risk For Severe Disease | 2027-10-01 |
| NCT07461714Guangzhou Medical UniversityAI-Driven Accurate Diagnosis of Pathogens in Severe Pneumonia | 2026-12-31 |
| NCT02738645Beijing Chao Yang HospitalA Clinical Cohort Study of Pneumonia in Respiratory Intensive Care Unit | 2026-12-31 |
| NCT07311343Beijing Tiantan HospitalOral Hygiene and Prophylactic Antibiotics to Prevent Intracerebral Hemorrhage Associated Pneumonia | 2026-12-31 |
Add all 11 to your calendar (.ics) → With an account.
Among the 142 studies in Pneumonia with a site in China, from their registry updates:
This tab as a report to print or save as PDF → With an account.
Severe pneumonia has a high morbidity and mortality. Humidified oxygen therapy, mechanical ventilation, and removal of airway secretions are the main non-drug treatments. However, mechanical ventilation leads to a high economic burden, and ventilator-associated pneumonia may increase patient mortality. Therefore, it is necessary to conduct in-depth research on early release from the ventilator and oxygen therapy. Studies have shown that high-flow nasal oxygen therapy (HFNC) improves airway humidification and oxygenation in patients. The respiratory humidification therapy device (AIRVOTM2) is mainly used internationally, but clinical studies on artificial airway patients are limited.
In the previous study, we improved the "New Artificial Airway High Flow Humidification Oxygen Therapy Device" (NTHF) to improve the accuracy of gas flow rate, and unified the baseline with AIRVOTM2. The status quo of the obvious differences in the airway humidification effect of patients. The pre-experiment again found that the gas flow rate consumption was significantly lower than that of AIRVOTM2 after the NTHF exhalation port was optimized, and the gas flow rate was proportional to the inhaled gas humidity. Based on this, we hypothesized that the flow rate of the optimized expiratory port of NTHF is more stable than that of AIRVOTM2, which can improve the airway humidification effect of patients. We intend to adopt a randomized controlled clinical study design, by comparing the application of two oxygen therapy devices in patients with severe pneumonia artificial airway, to explore whether NTHF can promote the clearance of airway secretions in patients with severe pneumonia and improve the therapeutic effect of severe pneumonia. Oxygen therapy nursing mode in patients with severe pneumonia artificial airway.
On the basis of the previous study, through the randomized controlled study design, it is proved that the spiral oxygen therapy exhalation port can reduce the consumption of the gas flow rate of the oxygen therapy device, improve the airway humidification and defense system ability of patients, and promote the infection control of patients with severe pneumonia. Innovate the oxygen therapy mode of NTHF in artificial airway patients with severe pneumonia to achieve the purpose of reducing mechanical ventilation and improving the therapeutic effect.
Before the start of the study, all enrolled patients were required to sign an informed consent form. Patients who met the inclusion criteria were divided into NTHF exhalation port optimization group (experimental group) and AIRVOTM2 exhalation port conventional group (control group) according to the ratio of 1:1, with 78 cases in each group. The method of block randomization with random block size is adopted, and the random number and grouping result generated by the computer are used to make a random grouping card, which is stored in a sealed and opaque envelope with the same surface. And the envelopes are numbered one-time according to the sequence number of the random grouping method. The researcher selects the corresponding envelope according to the order in which the subjects entered the experiment, obtains the grouping number, and gives the subjects different high-flow humidified oxygen therapy strictly according to the card.
Blind method: This study is a single-blind study. The researcher clearly defines the treatment group, but the index evaluation, data collection and data statistics are completed by different trained researchers, and the treatment group is not clear.
Intervention group: use NTHF, adjust the MR850 humidifier to invasive automatic gear, the temperature sensor automatically adjusts and maintains the gas temperature at the entrance of the tracheal tube at 37°C according to the feedback temperature, and monitors and maintains SpO2 between 94% and 100%. , adjust the concentration of the venturi valve and the corresponding oxygen flow according to the monitored pulse oxygen saturation (SpO2), and test the pipeline at the preset gas flow rate levels of 40L/min, 50L/min and 60L/min respectively. Connect the actual gas flow rate value and gas flow rate loss difference before and after the optimized expiratory joint (screw joint), and measure the gas temperature and humidity at the near-patient end of the pipeline at the corresponding gas flow rate.
Control group: use AIRVOTM2 (Fisher \& Paykel, Auckland, New Zealand), select the output gas temperature of 37°C, monitor and maintain SpO2 between 94% and 100%, and adjust the output gas flow rate of the therapeutic apparatus to 40L/min and 50L/min respectively. and 60L/min, measure the actual gas flow rate and the gas flow loss difference before and after each flow rate horizontal pipeline is connected to the conventional exhalation joint (matching special exhalation joint), and at the corresponding gas flow rate, measure the gas near the patient end of the pipeline. temperature and humidity.
Go through the criteria one by one — yes, no or not sure — and take the list to your doctor or the study team. Kept in this browser only.
The age of the patient is ≥18 years old and meets the diagnostic criteria for severe pneumonia.
The patient has artificial airway preparation or has been released from the ventilator.
Needs to receive oxygen therapy for more than 24 hours.
Exclusion Criteria:
Patients with one-lung ventilation
Patients with pregnancy and end-stage tumors ③Airway hemorrhage
Underlined terms in the criteria open these too. Explained by clinicaltrials.gg, not part of the registry record. The study team decides who can take part.
Before you join, the study team explains what taking part involves — its purpose, what happens, the risks and possible benefits — and answers your questions, so you can decide freely. Consent is usually recorded on a form (the informed consent form, ICF) signed by you or, where the law allows, by someone legally authorized to decide for you.
You can keep asking questions during the study, you are told of new information that matters, and you can choose to leave at any time.
Informed consent
Before you join, the study team explains what taking part involves — its purpose, what happens, the risks and possible benefits — and answers your questions, so you can decide freely. Consent is usually recorded on a form (the informed consent form, ICF) signed by you or, where the law allows, by someone legally authorized to decide for you.
You can keep asking questions during the study, you are told of new information that matters, and you can choose to leave at any time.
Explained by clinicaltrials.gg, not part of the registry record. The study team decides who can take part.
Using NTHF, adjust the MR850 humidifier to invasive automatic gear, the temperature sensor automatically adjusts and maintains the gas temperature at the entrance of the tracheal tube at 37°C according to the feedback temperature, and monitors and maintains SpO2 between 94% and 100%. The monitored pulse oxygen saturation (SpO2) is used to adjust the concentration of the venturi valve and the corresponding oxygen flow rate. At the preset gas flow rate levels of 40L/min, 50L/min and 60L/min, the test pipeline is connected to optimize the breath. The actual gas flow rate value and the gas flow rate loss difference before and after the gas joint (screw joint), and at the corresponding gas flow rate, measure the gas temperature and humidity at the near-patient end of the pipeline.
Device: high-flow oxygen therapy device for Severe pneumonia patients with artificial airway
Use AIRVOTM2 (Fisher \& Paykel, Auckland, New Zealand), select the output gas temperature of 37°C, monitor and maintain SpO2 between 94% and 100%, and adjust the output gas flow rate of the therapy device to 40L/min, 50L/min and 60L/min, respectively. min, measure the actual gas flow rate value and the gas flow rate loss difference before and after each flow rate horizontal pipeline is connected to the conventional exhalation joint (matching special exhalation joint), and measure the gas temperature and humidity near the patient end of the pipeline at the corresponding gas flow rate.
Device: AIRVOTM2 device for Severe pneumonia patients with artificial airway
Using NTHF, adjust the MR850 humidifier to invasive automatic gear, the temperature sensor automatically adjusts and maintains the gas temperature at the entrance of the tracheal tube at 37°C according to the feedback temperature, and monitors and maintains SpO2 between 94% and 100%. The monitored pulse oxygen saturation (SpO2) is used to adjust the concentration of the venturi valve and the corresponding oxygen flow rate. At the preset gas flow rate levels of 40L/min, 50L/min and 60L/min, the test pipeline is connected to optimize the breath. The actual gas flow rate value and the gas flow rate loss difference before and after the gas joint (screw joint), and at the corresponding gas flow rate, measure the gas temperature and humidity at the near-patient end of the pipeline.
Use AIRVOTM2 (Fisher \& Paykel, Auckland, New Zealand), select the output gas temperature of 37°C, monitor and maintain SpO2 between 94% and 100%, and adjust the output gas flow rate of the therapy device to 40L/min, 50L/min and 60L/min, respectively. min, measure the actual gas flow rate value and the gas flow rate loss difference before and after each flow rate horizontal pipeline is connected to the conventional exhalation joint (matching special exhalation joint), and measure the gas temperature and humidity near the patient end of the pipeline at the corresponding gas flow rate.
level of flow rate proximal to the patient
The gas flow rate was measured using the MF5612 split display gas mass flowmeter produced by Sixiang Microelectronics in the United States
Time frame: On the day of using the high-flow humidified oxygen therapy device
level of flow rate proximal to the patient
The gas flow rate was measured using the MF5612 split display gas mass flowmeter produced by Sixiang Microelectronics in the United States
Time frame: 48 hours after start of high flow oxygen therapy
level of flow rate proximal to the patient
The gas flow rate was measured using the MF5612 split display gas mass flowmeter produced by Sixiang Microelectronics in the United States
Time frame: 7th days after start of high flow oxygen therapy
level of sputum viscosity
sputum viscosity is assessed with a sputum viscometer
Time frame: 24th, 48th and 7th days after start of high flow oxygen therapy
Level of oxygenation
Oxygenation is assessed by arterial blood gas sample
Time frame: 24th, 48th and 7th days after start of high flow oxygen therapy
Patient satisfaction scoreg greater than or equal to 90
Using Hospital Designated Satisfaction Questionnaire which include comfort, bloating, dry mouth, ability to hear and speak(Total score is 100 points)
Time frame: the 7th day after start of high flow oxygen therapy
Plan to share: No
No publications or documents are linked to this record.
Start is estimated for Aug 2022; primary completion for Aug 2024, 24 months later.
Of 260 non-industry interventional studies with no phase under Pneumonia, half reached primary completion within 22 months of starting (the median), counting those still running; a quarter within 11 and three quarters within 31. This study's planned 24 months is close to that.
Counting every sponsor, half of 267 studies reached it within 22 months; a quarter within 11 and three quarters within 31.
How these figures are worked out, and which studies are left out of them.
This study is not yet recruiting, as verified in Jul 2022. You cannot join it, but the record below documents what was studied.
Get an email when the registry record changes — status, dates, results — or when someone posts here.
Sign in to followQuestions and observations about this study, from anyone following it. Not medical advice, and not a channel to the study team — their contact details are on the registry record.
Sign in to join the discussion. Reading takes no account; posting does. You choose a display name, and a pseudonym is the default.
Nothing here yet. If you are running this trial, taking part in it, or weighing whether to, this is the place to say so.
Shenzhen Second People's Hospital