An observational study in Coronary Artery Disease, Optical Coherence Tomography and Stent, sponsored by Yonsei University. Active, not recruiting at 1 site in South Korea. Open to participants aged 19 Years and older. Per ClinicalTrials.gov, last updated 2026-04-24.
Sponsored by Yonsei University · Observational
Help build ClinicalTrials.gg — short surveys, remote interviews or testing, in your language. Take part →
Among 64 studies in Coronary Artery Disease by Yonsei University — 13 open to participants now, 18 under way, none of them phase 3. Coronary Artery Disease · Yonsei University.
Among the 64 studies in Coronary Artery Disease by Yonsei University, this one is the 24th largest by planned enrollment of the 26 observational ones that give a count, is one of 5 that started in 2022, is one of 26 observational ones, reaches primary completion later than 5 of the 17 other live ones, and was the 49th registered.
4,866 studies on the registry are indexed under Coronary Artery Disease; 894 are open to participants now.
Browse Coronary Artery Disease studies →13 of the 64 studies in Coronary Artery Disease by Yonsei University are open now, in 1 country. Recruiting first, the newest first:
Yonsei University · Sites in Korea, Republic of
Ages 18+
Yonsei University · Sites in Korea, Republic of
Ages 19–80
Yonsei University · Sites in Korea, Republic of
Ages 19+
Yonsei University · Sites in Korea, Republic of
Ages 19+
Yonsei University · Sites in Korea, Republic of
Ages 19+
By country, each count listing its studies:
Of the 593 Coronary Artery Disease studies recruiting now, 404 (68%) set no upper age limit and 68 (11%) stop at 75 or younger; 37 take children under 18; 50 take healthy volunteers.
This study: 19 Years and older · all sexes · no healthy volunteers.
The full table on the hub →This tab as a report to print or save as PDF → With an account.
64 studies; the count open now beside each. This study's row is marked.
First in 2003; this study’s year is marked. 5 started in 2022.
By drug class, each counting the studies that test any of its medicines:
This study's planned enrollment of 30 is below the median of 326 across 1,691 observational studies indexed under Coronary Artery Disease.
Median enrollment 540 across the 38 interventional studies, 300 across the 26 observational. Of the 28 that completed or were terminated, 0 (0%) have results posted.
This tab as a report to print or save as PDF → With an account.
Yonsei University is the lead sponsor of 1,421 studies on the registry; 241 are open to participants now.
4 of the studies in Coronary Artery Disease by Yonsei University that are under way reach primary completion within a year, 0 of them phase 3. Phase 3 first, then by date:
| Study | Primary completion |
|---|---|
| NCT05340361Yonsei UniversityEfficacy and Safety of Zotarolimus-eluting Stent Overexpansion With OCT | 2026-12-31 |
| NCT05936606Yonsei UniversityTailored Anti-platelet Therapy After DES Implantation in High-risk Patients | 2027-05 |
| NCT07235657Yonsei UniversityAI-Assisted Interpretation of Cardiac CT in the Emergency Department | 2027-06 |
| NCT05488665Yonsei UniversityThe COMPLETE Treatment of Bifurcation With Two-stent Techniques: Randomized Comparison of Crush Versus Culotte Technique | 2027-09-27 |
Add all 4 to your calendar (.ics) → With an account.
Among the 64 studies in Coronary Artery Disease by Yonsei University, from their registry updates:
This tab as a report to print or save as PDF → With an account.
Investigators aimed to evaluate efficacy and safety of expansion capacity of zotarolimus-eluting Stent assessed by optical coherence tomography (OCT) in vivo study.
Single stent implantation (also called "provisional stenting") is currently the preferred technique for percutaneous coronary interventions on the majority of unprotected left main (LM) or non-LM bifurcations. During provisional stenting, proximal optimization technique (POT), proved to correct both the proximal main vessel (MV) malapposition and/or optimize the side branch (SB) ostium strut opening for proper wire re-crossing into the distal cell, might be crucial step and may warrant improved long-term clinical outcomes in the setting of major proximal and distal reference vessel size mismatch (like often in LM bifurcation or diffuse tapered long lesion).
Recently, second-generation drug-eluting stent (DES) implantation is recommended over BMS for PCI in patients with ischemic heart disease (IHD) due to superior efficacy and safety. However, percutaneous coronary intervention (PCI) with DES for lesion with the discrepancy of proximal and distal reference vessel size, such as LM or non-LM bifurcation lesion, diffuse tapered long lesion, and ectatic or aneurysmal coronary artery, is challenging due to stent optimization because expert consensus recommend that stent diameter is selected by distal reference diameter, which need stent overexpansion for POT.
OCT is a utility that can accurately measure reference vessel diameter and lesion length pre-PCI, which is useful for stent optimization by a suitable stent selection and pre- and post-interventional strategies. OCT also demonstrated higher sensitivity to detect stent malapposition, edge dissection, and tissue prolapsed than IVUS post-PCI. Thus, OCT-guided PCI can be helpful to optimize DES implantation in patients with dilated coronary arteries despite the potential limitation of depth penetration and attenuation images by thrombus.
Zotarolimus-eluting stent (Onyx family stent, Medtronic, Santa Rosa, CA, USA) was developed in response to the demand for stents with improved radiographic visibility. It has a novel thin strut composite wire stent platform that is covered with the same zotarolimus-eluting durable polymer coating as its predecessors. The metallic stent platform consists of a composite wire made from a dense platinum-iridium core, which makes the struts radiopaque, and an outer layer of cobalt-chromium alloy. The dense core also allows for reduced strut thickness, which might be associated with a decreased risk of stent thrombosis.
Onyx family stent has been labeled for maximum stent inner diameter by easy crowns platform (2.00-2.5 mm, 6.5 Crowns; 2.75-3.0 mm, 8.5 crowns; 3.5-4.0 mm, 9.5 crowns; 4.5-5.0 mm; 10.5 crowns). However, safety and efficacy of DES overexpansion is still concerned as safety of efficacy of there are limited data regarding Onyx family stent overexpansion in vivo.
This study aims to evaluate the safety and efficacy of Onyx family stent overexpansion for lesion with the discrepancy between proximal and distal reference vessel which need stent overexpansion for POT, assessed by OCT, providing high-resolution (10 µm) imaging which enables the detection of strut fracture, malapposition.
Patients with IHD had a discrepancy between proximal and distal reference vessels requiring stent implantation and considering stent overexpansion will be recruited.
Go through the criteria one by one — yes, no or not sure — and take the list to your doctor or the study team. Kept in this browser only.
Exclusion Criteria:
Underlined terms in the criteria open these too. Explained by clinicaltrials.gg, not part of the registry record. The study team decides who can take part.
An allergy, or another reaction of the immune system, to a substance. “Hypersensitivity to the study drug” means a known allergic reaction to it — not every side effect a medicine can have.
A reason a treatment, test or procedure should not be given to a particular person, such as an allergy, another illness or a medicine they take.
Able to become pregnant: from the first period until menopause, unless permanently unable to through surgery (removal of the womb, or of both ovaries or both fallopian tubes).
Criteria for people of childbearing potential usually ask for a negative pregnancy test and for contraception during the study and for a time after it.
The study doctor’s estimate of how long someone is likely to live. Criteria use it so that people can stay in the study long enough for it to answer its question.
Hypersensitivity
An allergy, or another reaction of the immune system, to a substance. “Hypersensitivity to the study drug” means a known allergic reaction to it — not every side effect a medicine can have.
Explained by clinicaltrials.gg, not part of the registry record. The study team decides who can take part.
Contraindication
A reason a treatment, test or procedure should not be given to a particular person, such as an allergy, another illness or a medicine they take.
Explained by clinicaltrials.gg, not part of the registry record. The study team decides who can take part.
Childbearing potential
Able to become pregnant: from the first period until menopause, unless permanently unable to through surgery (removal of the womb, or of both ovaries or both fallopian tubes).
Criteria for people of childbearing potential usually ask for a negative pregnancy test and for contraception during the study and for a time after it.
Explained by clinicaltrials.gg, not part of the registry record. The study team decides who can take part.
Life expectancy
The study doctor’s estimate of how long someone is likely to live. Criteria use it so that people can stay in the study long enough for it to answer its question.
Explained by clinicaltrials.gg, not part of the registry record. The study team decides who can take part.
OCT examination is performed using a frequency-domain OCT system (C7 DragonflyTM OPTISTM Imaging Catheter, Abbott Vascular, Santa Clara, CA, USA) with a 5.4 or 7.5 cm total pullback length according to a non-occlusive technique. The procedure is performed via radial or femoral access with a ≥6 Fr guiding catheter. The OCT catheter is advanced over the 0.014-inch PCI wire and the implanted stent was crossed after administration of intracoronary nitrates of 200 µg. For blood clearing, contrast media was injected through the guiding catheter with an automated power injector. The standard infusion rate was 4 mL/s for 4 seconds with 250 PSI. Follow-up OCT image acquisition was achieved with the same method. After post-PCI OCT, we evaluate the factor regarding post-PCI optimization target by European Expert Consensus.
Device: Optical coherence tomography-guided percutaneous coronary intervention · Device: Optical coherence tomography-guided Onyx family stent expansion
OCT examination is performed using a frequency-domain OCT system (C7 Dragonfly OPTIS Imaging Catheter, Abbott Vascular, Santa Clara, CA, USA) with a 5.4 or 7.5 cm total pullback length according to a non-occlusive technique. The procedure is performed via radial or femoral access with a ≥6 Fr guiding catheter. The OCT catheter is advanced over the 0.014-inch PCI wire and the implanted stent was crossed after administration of intracoronary nitrates of 200 µg. For blood clearing, contrast media was injected through the guiding catheter with an automated power injector. The standard infusion rate was 4 mL/s for 4 seconds with 250 PSI. Follow-up OCT image acquisition was achieved with the same method. After post-PCI OCT, we evaluate the factor regarding post-PCI optimization target by European Expert Consensus.
Also known as: Zotarolimus-eluting stent (Onyx family stent, Medtronic, Santa Rosa, CA, USA)
1. Expansion of 2.25, 3.0, and 4.0 mm Onyx family stent@ nominal pressure 2. OCT pullback 3. Expansion with over 0.5mm sized non-compliant balloon of each stent 4. OCT pullback 5. Expansion with over 1.0mm sized non-compliant balloon of each stent 6. OCT pullback 7. Expansion with over 1.25\~1.5mm sized non-compliant balloon of each stent 8. OCT pullback 9. Evaluation of polymer status with overexpansion assessed by an electric microscope
Maximal stent overexpansion (%)
defines as the ratio of the maximal stent diameter to each diameter of stent
Time frame: Through procedure completion, up to 24 hours
Stent strut fracture
defines as none or fewer visible stent strut on the cross-sectional view by performing OCT within stented segments (In in vivo and in vitro groups)
Time frame: Through procedure completion, up to 24 hours
Absolute average stent diameter (mm) in the maximal stent expansion site
Absolute average stent diameter (mm) in the maximal stent expansion site ((In in vivo and in vitro groups)
Time frame: Through procedure completion, up to 24 hours
Grade of polymer damage assessed by electron microscope
Grade of polymer damage assessed by electron microscope (In in vitro group)
Time frame: Through procedure completion, up to 1-month
Plan to share: No — I'll share the IPD if other researchers have good reason.
No publications or documents are linked to this record.
Started Mar 2022 (actual). Primary completion is estimated for Dec 2026, 57 months after the start.
Of 638 non-industry observational studies under Coronary Artery Disease, half reached primary completion within 48 months of starting (the median), counting those still running; a quarter within 23 and three quarters within 122. This study's planned 57 months is above that.
Counting every sponsor, half of 763 studies reached it within 41 months; a quarter within 21 and three quarters within 87.
How these figures are worked out, and which studies are left out of them.
This study is active, not recruiting, as verified in Apr 2026. You cannot join it, but the record below documents what was studied.
Get an email when the registry record changes — status, dates, results — or when someone posts here.
Sign in to followQuestions and observations about this study, from anyone following it. Not medical advice, and not a channel to the study team — their contact details are on the registry record.
Sign in to join the discussion. Reading takes no account; posting does. You choose a display name, and a pseudonym is the default.
Nothing here yet. If you are running this trial, taking part in it, or weighing whether to, this is the place to say so.