POCUS AI in Critically Ill Patients

An observational study in Critical Illness, sponsored by Hospital Garcia de Orta. Completed at 1 site in Portugal. Open to participants aged 18 Years and older. Per ClinicalTrials.gov, last updated 2022-09-16.

Sponsored by Hospital Garcia de Orta · Observational

Study type
Observational
Model
Cohort
Time perspective
Prospective
Enrollment
99
Ages
18 Years and older
Sex
All
01

Study summary

This is a prospective study that aims to assess the differences in point-of-care ultrasound assessment (POCUS) with portable and ultra-portable devices, using conventional vs artificial intelligence (AI) methodologies, performed by experienced vs inexperienced physicians, in critically ill patients.

Read the detailed description
  1. Type of Study Prospective study.
  2. Sample Individuals, aged 18 years or over, admitted to the intensive care department, according to the clinical assessment of the medical team, benefit from an ultrasound assessment.

Convenient sample size up to 100 patients

Exclusion criteria:

Patients with atrial fibrillation or other dysrhythmias; Inappropriate acoustic window for ultrasound assessment

c. Devices used The study in question aims to perform an ultrasound using two ultrasound scanners belonging to the Intensive Care Department:

  • VenueTM The VenueTM is a portable ultrasound device from GE Healthcare, with touch screen technology, which allows the performance of transthoracic echocardiography and chest ultrasound with M-mode, two-dimensional (2D) and Doppler (color, pulsed, continuous and tissue). Additionally, it uses methodologies that allow the automatic measurement of parameters such as left ventricular ejection fraction, inferior vena cava diameter and its variability, integral time-velocity of flow in the left ventricular outflow tract.
  • Butterfly iQ+ The Butterly iQ+ is an ultra-portable ultrasound device, belonging to devices commonly called pocket devices, measuring 163 x 56 x 35 mm. It has a rechargeable battery that allows an autonomy of 2 hours of continuous use. By connecting to a smartphone and after installing the brand application, it allows the performance of transthoracic and pulmonary echocardiography with M-mode, two-dimensional (2D) and color Doppler. It also allows automatic determination of left ventricular ejection fraction. Acquiring images for later review is also possible with this device. d. Variables Demographic, clinical, hemodynamic and respiratory monitoring, laboratory variables - including troponin T, NT-proBNP, creatinine, urea, sodium, potassium, lactate, when available -, severity and mortality scores (SOFA, SAPS- II, APACHE-II) and ultrasound variables. - Echographic variables - transthoracic echocardiography: Acoustic window: nominal qualitative variable, expressed as "good", "reasonable" or "technically difficult". Patient positioning: nominal qualitative variable, expressed in "left lateral decubitus", "right lateral decubitus" or "supine position".

In the 4-chamber apical window (A4C), the following variables should be evaluated (by a physician experienced in echocardiography), with the

Butterfly iQ+ device and then with the VenueTM:

  • Left Ventricular Ejection Fraction (LVEF) manual: discrete quantitative variable, expressed in %; refers to the manual measurement of LVEF, obtained through the LV volumes in end-diastole and in end-systole. In the A4C window, the following variables should be evaluated (by a physician experienced in echocardiography and an inexperienced physician), with the Butterfly iQ+ device and then with the VenueTM:
  • LVEF auto: discrete quantitative variable, expressed in %; refers to the determination of LVEF through automatic methodology. In the 5-chamber apical window (A5C), the following variables should be evaluated (with the VenueTM device and by a physician experienced in echocardiography):
  • Left ventricular outflow tract velocity time integral (LVOT VTI) manual:

discrete quantitative variable, expressed in cm; refers to manual measurement of the LVOT VTI. In the A5C window, the following variables should be evaluated (by a physician experienced in echocardiography and an inexperienced physician), with the VenueTM device:

  • LVOT VTI auto: discrete quantitative variable, expressed in cm; refers to the determination of the LVOT VTI through automatic methodology, whose calculation will result from the average of 3 consecutive cycles. In the subcostal window, the following variables should be evaluated (by a physician experienced in echocardiography), with the Butterfly iQ+ device and then with the VenueTM: • Maximum diameter of the manual inferior vena cava (IVC): continuous quantitative variable, expressed in mm, to one decimal place; refers to manual measurement of VCI. • Minimum diameter of manual IVC: continuous quantitative variable, expressed in mm, to one decimal place; refers to manual measurement of VCI. Manual IVC diameter variation: discrete quantitative variable, expressed in %. In the subcostal window, they must be evaluated (by a physician experienced in echocardiography and inexperienced physician), with the

VenueTM device, the following variables:

  • Maximum diameter of the inferior vena cava (IVC) auto: continuous quantitative variable, expressed in mm, to one decimal place; refers to the determination of the diameter of the VCI through automatic methodology.
  • Minimum diameter of auto VCI: continuous quantitative variable, expressed in mm, to one decimal place; refers to the determination of the diameter of the VCI through automatic methodology.
  • Auto IVC diameter variation: discrete quantitative variable, expressed in %. e. Methodology - study stages The ultrasound evaluation of each patient included in the study will be performed by two different doctors. It is intended to evaluate the variables previously discriminated by an experienced doctor in ultrasound and by a non-experienced doctor. Each parameter must be checked in triplicate and registered.

Regarding the echocardiographic assessment, experienced physicians should determine the echographic variables in a conventional way (manual) and also through an automatic methodology, first using the Butterfly iQ+ device and later the VenueTM device. Non-experienced physicians will only perform the determination of variables using the automatic methodology (therefore only the variables for which this option is available). The collection of parameters related to the echocardiographic evaluation will be performed in a previously established order in order to avoid bias in subsequent comparisons. Blood pressure, heart rate, respiratory rate and peripheral oxygen saturation should be recorded during the ultrasound assessment. Regarding laboratory variables, the results available in the analysis of the patient on the day of the ultrasound evaluation will be considered (an additional study will not be requested if any of the measurements has not been previously requested by the attending physician). Any need for vasopressor, inotropic or invasive mechanical ventilation should also be recorded. e) Collection and recording of data Demographic and clinical variables will be collected using the patients' clinical records. The variables referring to the ultrasound assessment will be recorded at the time of their acquisition in the CRF.

02

Conditions studied

  • Critical Illness

Browse trials for

03

In context

Critical Illness

1,780 studies on the registry are indexed under Critical Illness; 442 are open to participants now.

This study's enrollment of 99 is below the median of 140 across 814 observational studies indexed under Critical Illness.

Browse Critical Illness studies →

Lead sponsor

Hospital Garcia de Orta is the lead sponsor of 3 studies on the registry; 1 is open to participants now.

Counted across the registry records on this site, refreshed daily.

04

Who can participate

Ages eligible
18 Years and older
Sexes eligible
All
Accepts healthy volunteers
No
Sampling method
Non-probability sample

Study population

Patients admitted to the intensive care department which, according to the clinical assessment of the medical team, would benefit from an ultrasound assessment.

Go through the criteria one by one — yes, no or not sure — and take the list to your doctor or the study team. Kept in this browser only.

Inclusion criteria

  • Patients aged 18 years or over, admitted to the intensive care department which, according to the clinical assessment of the medical team, would benefit from an ultrasound assessment.

Exclusion criteria

Exclusion Criteria:

  • Patients with atrial fibrillation or other dysrhythmias;
  • Inappropriate acoustic window for ultrasound assessment.
05

Study design

Observational model
Cohort
Time perspective
Prospective
Enrollment
99 participants (actual)
Target follow-up
1 Day
Patient registry
Yes
06

What researchers measure

Primary outcomes

  1. Assess artificial intelligence ultrasound software to assess various echocardiographic variables useful for the management of critically ill patients

    Assess the accuracy of automatic measurements to determine ultrasound parameters using portable versus ultra-portable ultrasound scanners. - Assess the accuracy of POCUS performed by inexperienced professionals using portable versus ultraportable ultrasounds.

    Time frame: up to 48 weeks

07

Study locations

1 site
  • Hospital Garcia de Orta
    Lisboa, Almada 2801-267, Portugal
08

References and documents

Individual participant data

Plan to share: No

No publications or documents are linked to this record.

09

Updates

Tracking since Sep 25, 2026
No changes since tracking began. The registry record was last updated on Sep 16, 2022, before this site started recording changes on Sep 25, 2026. Its history is on ClinicalTrials.gov ↗
10

Registry details

Key details

Study ID
NCT05336448
Lead sponsor
Hospital Garcia de Orta
Responsible party
Filipe André Gonzalez (Senior consultant of Internal Medicine and Intensive Medicine, PhD student, Hospital Garcia de Orta) — Principal investigator
First posted
Apr 20, 2022
Start date
Jul 27, 2021
Primary completion
May 29, 2022
Completion
Jun 11, 2022
Last update
Sep 16, 2022

Oversight

Data monitoring committee
No
FDA-regulated drug
No
FDA-regulated device
No
View the source record on ClinicalTrials.gov ↗

Not currently enrolling

This study is completed, as verified in Sep 2022. You cannot join it, but the record below documents what was studied.

Follow this study

Get an email when the registry record changes — status, dates, results — or when someone posts here.

Sign in to follow

Discussion

Questions and observations about this study, from anyone following it. Not medical advice, and not a channel to the study team — their contact details are on the registry record.

Sign in to join the discussion. Reading takes no account; posting does. You choose a display name, and a pseudonym is the default.

Nothing here yet. If you are running this trial, taking part in it, or weighing whether to, this is the place to say so.

Start the discussion