CClinicalTrials.gg
RecruitingNCT05040074Updated Sep 10, 2021

SQ-Kyrin TMVr FIM Study

An interventional study of SQ-Kyrin Transcatheter Edge-to-Edge Valve Repair System in Mitral Regurgitation, sponsored by Shanghai Shenqi Medical Technology Co., Ltd. Recruiting at 1 site in China. Open to participants aged 18 Years and older. Per ClinicalTrials.gov, last updated 2021-09-10.

Sponsored by Shanghai Shenqi Medical Technology Co., Ltd · Not applicable, Interventional, and Treatment

From the registry’s dates

  • Primary completion was expected by Oct 2022, 4 years ago, but the record still lists the study as recruiting.
  • Registered 4 months after the study started (first participant enrolled Apr 2021, registered Aug 2021).
  • Started Apr 2021; still recruiting 5 years 6 months later.
Phase
Not applicable
Study type
Interventional
Enrollment
20
Allocation
Not applicable
Ages
18 Years and older
Sex
All
01

Study summary

A feasibility study to evaluate the effectiveness and safety of the SQ-Kyrin Transcatheter Edge-to-Edge Valve Repair System for the treatment of moderate-to-severe mitral regurgitation in patients with high surgical risk.

Read the detailed description

This is a prospective, multicenter, single-arm observation, feasibility clinical study that plans to enroll a total of not less than 10 and not more than 30 patients, adopts the post-op immediate technical success rate as the primary endpoint, and uses the all-cause mortality at 30 days post-op, incidence of serious adverse event at 30 days post-op, device success rate at 30 days post-op, and procedural success rate at 30 days post-op as secondary endpoints to evaluate the effectiveness, safety, and feasibility of the Transcatheter Edge-to-Edge Valve Repair System of Shanghai Shenqi Medical Technology Co., Ltd. in clinical use and preliminarily evaluate the product's performance. A phasic study report (for phasic data summary and analysis) will be issued after completion of the 30-day postoperative follow-up to evaluate the effectiveness, safety, and feasibility of the device and apply for clinical studies before official registration and marketing. In the meantime, patients enrolled will continue to be followed up for 6 months and 1-5 years post-op to evaluate the long-term effect of the mitral valve repair system.

02

Conditions studied

  • Mitral Regurgitation

Keywords

  • Mitral Regurgitation
03

In context

Mitral Valve Insufficiency

459 studies on the registry are indexed under Mitral Valve Insufficiency; 148 are open to participants now.

This study's planned enrollment of 20 is below the median of 61 across 274 interventional studies indexed under Mitral Valve Insufficiency.

Browse Mitral Valve Insufficiency studies →

Lead sponsor

Shanghai Shenqi Medical Technology Co., Ltd is the lead sponsor of 10 studies on the registry; 5 are open to participants now.

Counted across the registry records on this site, refreshed daily.

04

Who can participate

Ages eligible
18 Years and older
Sexes eligible
All
Accepts healthy volunteers
No

Inclusion criteria

  1. Severe mitral valve regurgitation ≥ 3+ (moderate-to-severe mitral regurgitation disease);
  2. Patients with high or prohibitive risk for conventional open thoracic surgery as defined by STS risk scoring result; subjects who are judged as not tolerating mitral valve surgery due to STS procedural mortality risk ≥ 8% for mitral valve replacement or presence of any of the following risk factors:

    1. Porcelain aorta or active ascending aortic atheroma
    2. Prior radiation therapy to mediastinum
    3. History of mediastinitis
    4. Left ventricular ejection fraction (LVEF) \< 40%
    5. Presence of unobstructed coronary artery bypass graft
    6. History of 2 or more cardiothoracic surgeries
    7. Liver cirrhosis
    8. Other surgical risk factors
  3. Degenerated MR patients, or functional MR patients who have received guideline-directed medical therapy (GDMT therapy)
  4. Age ≥ 18 years, male or female;
  5. Patients who are at extremely high risk or not suitable for conventional mitral valve surgery, as assessed by a multidisciplinary heart team (including at least one cardiac surgeon and one cardiologist);
  6. Anatomically suitable for transcatheter mitral valve repair by edge-to-edge technique and can be treated by the SQ-Kyrin device;
  7. Patients who can understand the objectives of the trial, volunteer to participate in the study, sign the informed consent form, and are willing to receive related examinations and clinical follow-up.

Exclusion criteria

Exclusion Criteria:

  1. History of cardiac and mitral valve surgeries;
  2. Infective endocarditis or evidence of active infection;
  3. Mitral valve stenosis;
  4. Severe uncontrolled coronary artery disease;
  5. Pulmonary artery hypertension (systolic pulmonary artery pressure > 70 mmHg);
  6. Severe right cardiac insufficiency;
  7. LVEF \< 30%;
  8. Cardiac function of NYHA Class IV;
  9. Patient is extremely week to tolerate surgery under general anesthesia, or in a shock state indicating circulatory support;
  10. Hypertrophic cardiomyopathy, restrictive cardiomyopathy, or constrictive pericarditis;
  11. Chronic dialysis;
  12. Definite coagulation disorder and severe coagulation system diseases;
  13. Clear contraindications for use of anticoagulants;
  14. Cerebral stroke or transient ischemic attack in the past 30 days;
  15. Any cardiac mass, left ventricular or atrial thrombosis identified by echocardiography;
  16. Other valve diseases that requiring surgery or intervention;
  17. Severe macrovascular disease requiring surgical treatment;
  18. Treatment-naive carotid artery stenosis > 70%;
  19. Imaging evidence of inappropriate cardiac and valve anatomy;
  20. Known hypersensitivity to contrast media, and nickel-titanium memory alloy products;
  21. Severe nervous system disorder compromising the cognitive ability;
  22. Life expectancy \< 12 months;
  23. Severe thorax deformity;
  24. Pregnant and lactating women.
05

Study design

Phase
Not applicable
Primary purpose
Treatment
Allocation
Not applicable
Intervention model
Single group
Masking
None (open label)
Enrollment
20 participants (estimated)

Study arms

  • Experimental
    SQ-Kyrin TMVr Feasibility Study

    Experimental group is allocated to use the transcatheter edge-to-edge valve repair system of Shanghai Shenqi Medical Technology Co., Ltd.

    Device: SQ-Kyrin Transcatheter Edge-to-Edge Valve Repair System

Interventions

  • DeviceSQ-Kyrin Transcatheter Edge-to-Edge Valve Repair System

    Transesophageal echocardiography-guided, implantable mitral valve clip repair system

06

What researchers measure

Primary outcomes

  1. Incidence of acute procedural success

    Must meet all the four items:1)no procedural mortality; 2)success in delivery and retrieval of the device delivery system; 3)successful deployment and accurate positioning of the device; 4)no emergency surgery or reintervention related to the device or surgical approach

    Time frame: Immediate postoperative

Secondary outcomes

  1. All-cause mortality

    Death from any cause

    Time frame: 1 month

  2. Incidence of serious adverse event(SAE)

    If the adverse event meets any of the criteria below, it is regarded as a serious adverse event (SAE): 1) results in death; 2) is life threatening, results in illness or injury; 3) requires inpatient hospitalization or prolongation of existing hospitalization; 4) results in a persistent or significant disability/incapacity; 5) results in a congenital anomaly/birth defect, fetal death, fetal distress; 6) results in medical or surgical intervention to prevent permanent impairment to body structure or a body function; 7) an important medical event that may not result in death, be life-threatening, or require hospitalization but may be considered serious when, based upon appropriate medical judgment, may jeopardize the patient or subject and/or may require intervention to prevent one of the outcomes listed in this definition.

    Time frame: 1 month

  3. Device success rate

    Definition of device success(must meet all the four items) :1) No procedural mortality or stroke;2) Proper deployment and positioning of the device;3) No emergency surgery or reintervention related to the device or surgical approach;4) The implanted mitral valve repair system achieves the following safety and effectiveness indicators: * No evidence of structural or functional abnormality * No device-related technical failure or complication * Significant functional improvement after valve repair, without significant stenosis (post-op EOA ≥ 1.5 cm2 and transvalvular pressure gradient \< 5 mmHg/valve regurgitation ≤ Grade 2+/no device-related hemolysis)

    Time frame: 1 month

  4. Procedural success rate

    Definition of procedural success(must meet the two items):1) Device success;2) Absence of the following severe complications: death; stroke; life-threatening hemorrhage; severe vascular complications; secondary severe organic heart diseases (e.g.: aortic dissection, left atrium/auricle rupture, left ventricular outflow tract obstruction, etc.); Grade II-III and above renal insufficiency; myocardial infarction or coronary ischemia requiring percutaneous coronary intervention (PCI) or coronary artery bypass grafting (CABG); severe hypotension, heart failure, respiratory failure requiring use of high-dose vasoactive medications/mechanical acids; any valve-related dysfunctions, including repair device detachment (single or two valve leaflets)/embolism/device-related autologous mitral valve damage/other conditions requiring second intervention.

    Time frame: 1 month

07

Study locations

1 of 1 sites recruiting
  • General Hospital of Northern Theater Command, PLA
    Shenyang, Liaoning 123005, China
    • Yaling Han, PhD · Contact
    Recruiting
08

References and documents

Study documents

  • Study protocol · Mar 31, 2021

Documents are hosted by the registry — open the source record to download them.

09

Updates

Tracking since Sep 25, 2026
No changes since tracking began. The registry record was last updated on Sep 10, 2021, before this site started recording changes on Sep 25, 2026. Its history is on ClinicalTrials.gov ↗
10

Registry details

Key details

Study ID
NCT05040074
Lead sponsor
Shanghai Shenqi Medical Technology Co., Ltd
Responsible party
Sponsor
First posted
Sep 10, 2021
Start date
Apr 1, 2021
Primary completion
Oct 2022 (estimated)
Completion
Oct 2026 (estimated)
Last update
Sep 10, 2021

Study contacts

Grace Gu
Contact
guchaojun@sqmedical.com
13636491192

Oversight

FDA-regulated drug
No
FDA-regulated device
No
View the source record on ClinicalTrials.gov ↗

Interested in this study?

Eligibility is decided by the study team. Share this record with your doctor or contact the team directly.

Contact study team

Follow this study

Get an email when the registry record changes — status, dates, results — or when someone posts here.

Sign in to follow

Discussion

Questions and observations about this study, from anyone following it. Not medical advice, and not a channel to the study team — their contact details are on the registry record.

Sign in to join the discussion. Reading takes no account; posting does. You choose a display name, and a pseudonym is the default.

Nothing here yet. If you are running this trial, taking part in it, or weighing whether to, this is the place to say so.

Start the discussion