An interventional study of Orbis-FundamentalVR MSICS Simulator in Surgical Education, sponsored by Orbis. Completed at 1 site in United Kingdom. Per ClinicalTrials.gov, last updated 2022-08-04.
Sponsored by Orbis · Not applicable, Interventional, and Other
Help build ClinicalTrials.gg — short surveys, remote interviews or testing, in your language. Take part →
Among 39 studies in Cataract with a site in United Kingdom — 8 open to participants now, 8 under way, 1 of them phase 3. Cataract · United Kingdom.
Among the 39 studies in Cataract with a site in United Kingdom, this one is the 24th largest by enrollment of the 29 interventional ones that give a count, is one of 2 that started in 2021, is one of 23 with no phase, and was the 28th registered.
1,635 studies on the registry are indexed under Cataract; 233 are open to participants now.
Browse Cataract studies →8 of the 39 studies in Cataract with a site in United Kingdom are open now. Recruiting first, the newest first:
Carl Zeiss Meditec AG · Sites in United Kingdom, Czechia, Germany and 1 more country
Ages 18+
Alcon Research · Sites in United Kingdom
Ages 18+
Queen's University, Belfast · Sites in United Kingdom
Ages 50+
Vision Care Collective Limited · Sites in United Kingdom
Ages 18+
University of Plymouth · Sites in United Kingdom
Ages 50–75
A study can be open while its sites in United Kingdom have not opened yet or have stopped. Only those recruiting at a site in United Kingdom →
Of the 142 Cataract studies recruiting now, 87 (61%) set no upper age limit and 8 (6%) stop at 75 or younger; 10 take children under 18; 14 take healthy volunteers.
This study: all sexes · healthy volunteers too.
The full table on the hub →This tab as a report to print or save as PDF → With an account.
39 studies; the count open now beside each. This study's row is marked.
First in 2007; this study’s year is marked. 2 started in 2021.
This study's enrollment of 44 is below the median of 79 across 1,096 interventional studies indexed under Cataract.
Median enrollment 100 across the 29 interventional studies, 157 across the 10 observational. Of the 20 that completed or were terminated, 7 (35%) have results posted.
This tab as a report to print or save as PDF → With an account.
12 of 39 have an industry lead sponsor. The 10 most frequent:
Orbis is the lead sponsor of 6 studies on the registry; 3 are open to participants now.
Orbis has 2 studies filed under Cataract — fewer than ten, so there is no comparison to draw.
1 of the studies in Cataract with a site in United Kingdom that are under way reach primary completion within a year, 0 of them phase 3. Phase 3 first, then by date:
| Study | Primary completion |
|---|---|
| NCT07228091Alcon ResearchSurgical Procedure Efficiency Evaluation stuDy | 2027-06 |
Add it to your calendar (.ics) → With an account.
Among the 39 studies in Cataract with a site in United Kingdom, from their registry updates:
This tab as a report to print or save as PDF → With an account.
Currently, surgical training is often conducted using the traditional "apprentice model", where a trainee observes a qualified surgeon and learns from him/her, and then the surgeon supervises the trainee performing surgery on a patient. The investigators believe that this conventional model has substantial limitations and drawbacks, making surgical training less efficient and less safe.
The investigators will test the hypothesis that intense virtual reality (VR) simulation-based ophthalmic surgical training improves initial acquisition of competence in key stages of manual small incision cataract surgery (MSICS). To do this, the investigators are proposing a randomized multi-country study. This mixed-method study will combine qualitative and quantitative data collection.
Orbis International partnered with FundamentalVR to create a manual small incision cataract surgical (MSICS) simulator, using virtual reality software combined with existing gaming technology. The result is a VR simulator available at a fraction of the cost of products currently on the market. This VR simulator will be the subject of this study.
All training within the 'educational intervention' of this study will be performed using simulation. There is no testing or surgical training on patients.
Study Design:
Prospective, investigator-masked education-intervention randomized controlled study of intensive virtual reality (VR) simulation-based surgical education of ophthalmologists in China, Ethiopia, India, Mongolia, Bangladesh, UK and USA.
Construct validity study of assessment scores generated by the VR simulator for novices versus experts.
Qualitative study of face validity of VR simulator, and acceptability questionnaire survey of users.
Purposes of study:
To investigate the efficacy of intensive VR simulation-based surgical education using the Orbis-FVR simulator. To examine whether it improves competence, is acceptable and has validity. To assess the construct validity of the VR simulator's assessment capacity.
Design Summary This research program involves a prospective, investigator-masked education-intervention randomized controlled study of intensive virtual reality (VR) simulation-based surgical education of ophthalmologists in China, Ethiopia, India, Mongolia, Bangladesh, UK and USA. Participants will be randomized, and surgical competency will be assessed at baseline and 1-month between groups. Competency will be assessed at baseline, using artificial eyes. Both groups will perform three full MSICS cases using model eyes at baseline. At one-month post intervention, both groups will again perform three full MSICS surgeries using model eyes for grading by masked evaluators using an existing, validated rubric (main outcome).
The study will also assess the construct validity of assessment scores generated by the VR simulator for novices versus experts. Both novices and experts will perform three full VR cases using the simulator. The first score will be disregarded to allow for familiarization with the hardware, and the mean of the second two cases will be recorded.
There will also be a qualitative study of face validity of the VR simulator, and an acceptability questionnaire-based survey of users. An anonymous survey will be administered to experts and novices, using a Likert scale.
Study Setting This is a multi-center study. The investigators will enroll trainee ophthalmologists (doctors who have graduated from medical school and are currently undergoing ophthalmology specialist training) at 9 ophthalmology training institutions in in China, Ethiopia, India, Mongolia, Bangladesh, the UK and USA.
Collaborating institutions:
London School of Hygiene and Tropical Medicine, UK Chittagong Eye Infirmary and Training Complex, Chittagong, Bangladesh Addis Ababa University, department of Ophthalmology, Menelik II Hospital, Addis Ababa, Ethiopia University of Gondar, Gondar, Ethiopia Dr. Shroff's Charity Eye Hospital (SCEH), New Delhi, India H.V. Desai Eye Hospital, Pune, India The First Central Hospital,, Ulaanbaatar, Mongolia Shenyang He Eye Specialist Hospital, China. Emory Eye Center, Atlanta, GA USA
Study Duration The training will be conducted during 2021, and will last 6 months.
Study Participants Current trainees enrolled between January and December of 2021 in all 9 training institutions will be selected according to the inclusion and exclusion criteria.
Informed Consent Potential participant trainees will be informed of the training opportunity and the study. Heads of Department will be involved in the process. Trainee participants will be informed in detail about the nature of the education-intervention study, that the training offered provides no official qualification and will not be recorded in their annual clinical training evaluation. All surgeons participating will be free to leave the study at any time.
Withdrawal Criteria Trainee participants are free to leave the study at any time. If this is the case for any participant, no effort will be made to recover any costs incurred. Data collected up to the point of withdrawal of consent will have been pseudo-anonymized and securely stored and will still be held and included in data analysis
Baseline Data Resident Trainees
Attending Consultants (experts)
Randomisation Sequence generation The randomization sequences will be computer generated and administered centrally by a statistician based at the London School of Hygiene and Tropical Medicine, who is independent of all other aspects of the trial. The investigators will use block randomization (block size 2 or 4), with a separate sequence for each of the ten recruitment sites, to ensure balance. The statistician will generate the code / sequence (as a block of 2 or 4).
Allocation Concealment The statistician will not have access to information about subsequent allocation, and the individual potential participants. The PI, co-investigators, and participants will have no prior access to the random sequence.
Randomization Implementation Trainees within the same institution, who have met the appropriate inclusion and exclusion (as detailed previously), will be eligible for randomization to the 'intervention' or 'control' arm. Each group of four trainee participants will be agreed by the Head of Training Program or Department.
For example (Blocks will be in groups of 4, 6 or 8 depending on the institution and the number of residents that meet the inclusion criteria):
A block of four potential participants is identified at Chittagong Eye Institute Training Center (CEITC), Bangladesh. Cards with the allocation or a block of four (two intervention and two control) will be printed and placed in sealed opaque envelopes. Physically, in Bangladesh, a block of four identical envelopes (e.g. block number 11) will be selected. Participants will be invited by the Head of Department to pick one of the four envelopes. In this example, CEITC randomization block 11 allocation might be:
IRO1101 Intervention IRO1102 Control IRO1103 Control IRO1104 Intervention
Training Intervention - Orbis-FVR Training Program
Pre-Learning (one month in advance)
Pre-Course Assignment (one week in advance)
The Orbis-FVR Virtual Reality MSICS simulator has 19 steps in total. Currently, 10 steps are animated and 9 are interactive, as follows:
Course Overview Participants must attend and successfully complete all sessions. All simulator tasks are to be completed in sequential order, in line with the course outline. A required score of 85 points for each interactive step must be reached three times in a row to advance to the next step in the course.
For each step within the simulation the following is recorded:
Step Time - The total time spent on a step including ALL attempts. Pass / Fail - The interpreted pass or fail result of the last attempt of the step.
Step score - Each step is scored between 0 and 100 points, based on user performance in completing the surgical objective, taking into account any adverse events.
Adverse events - For each step, if triggered, all of the adverse events are recorded.
Number of attempts - The number of attempts (including resets) of the step.
Course Content Each course will combine autonomous learning and live mentorship.
Autonomous learning will consist of a series of 15-minute video presentations, which include:
Live mentorship will be delivered in two ways:
Content hosting All content will be hosted on the Orbis Cybersight Learning Management System platform. Data will be randomized and anonymized by the Cybersight Program manager, who will not be involved in any other aspect of the research initiative.
Course delivery
Each day:
Local mentor will facilitate introductions in each morning session. This will cover:
Trainees will do self-practice for the remainder of the afternoon session
The MSICS simulator has a built in surgical assessment per step. Each interactive step has a possible score between 0 and 100. A score of 85 indicates "passing." Each trainee will complete each interactive step on the VR simulator a minimum of 5 times with a reliability gate (3) and minimum score of 85. Reliability gate of 3 was chosen based on similar interventions using like VR cataract simulators. Each trainee will complete at least 5 full cases on the VR simulator with a reliability gate (3) and minimum score of 85
Attendance to be recorded as follows:
Oversight and validation of the above will be done by the local mentor, as well as study personnel. The simulator itself will log that participants completed each step, with a detail of their performance, length of time spent, adverse events, score and final mark of pass/fail.
Risks and Limitations
There are no clinical risks within this study, as all the intervention training uses simulation. No patients are involved in any of the training. Patients are involved only as part of fully supervised, standardized, regulated and accredited post-graduate clinical and surgical training within the collaborating training institutions, all of which falls outside the study.
There are a number of broad risks in conducting this study.
There are expected limitations to this study:
VR Training Efficacy
Inclusion Criteria:
Exclusion Criteria:
Construct Validity
Inclusion Criteria
Exclusion Criteria
Will participate in an Intensive virtual reality (R) cataract simulation course that includes a five day instructor led VR course using the Orbis-FundamentalVR cataract surgical simulator, in addition to standard resident training at the training facility.
Device: Orbis-FundamentalVR MSICS Simulator
Will receive standard resident training at the training facility.
Cataract surgery training device, using virtual reality software combined with existing gaming technology for simulated surgery
Mean specific simulated surgical competency assessment score at one month
mean specific simulated surgical competency assessment score at one-month post-training intervention between groups (assessed using Sim-OSSCAR).
Time frame: up to 6 months
Step-specific analysis
Mean differences in Sim-OSSCAR score for the seven interactive steps assessed (incision, tunnel, AC entry, CCC, mobilization, removal and IOL). Total possible score 14.
Time frame: up to 6 months
Self-reported confidence ratings
(10-point Likert scale) in MSICS skills, and ophthalmic surgical skills
Time frame: up to 6 months
Novice and expert Orbis-FundamentalVR Simulator generated assessment scores ***As above for #2***
Construct validity study comparing scores generated by Orbis-FVR simulator between two cohorts of novice and expert MSICS surgeons.
Time frame: up to 6 months
PDFs hosted by the registry, ClinicalTrials.gov.
Plan to share: No
Ran from Jul 2021 to primary completion in Jul 2022, 12 months.
Of 306 non-industry interventional studies with no phase under Cataract, half reached primary completion within 18 months of starting (the median), counting those still running; a quarter within 7 and three quarters within 33. This study's 12 months is below that.
Counting every sponsor, half of 496 studies reached it within 17 months; a quarter within 9 and three quarters within 29.
How these figures are worked out, and which studies are left out of them.
This study is completed, as verified in Aug 2022. You cannot join it, but the record below documents what was studied.
Get an email when the registry record changes — status, dates, results — or when someone posts here.
Sign in to followQuestions and observations about this study, from anyone following it. Not medical advice, and not a channel to the study team — their contact details are on the registry record.
Sign in to join the discussion. Reading takes no account; posting does. You choose a display name, and a pseudonym is the default.
Nothing here yet. If you are running this trial, taking part in it, or weighing whether to, this is the place to say so.