CClinicalTrials.gg
CompletedNCT04876625OATMBUpdated May 22, 2023

OA Therapy for Mouth-breathers Who Snore

An interventional study of myTAP oral appliance plus mouth shield and myTAP oral appliance alone for first 4 weeks in Snoring, Mouth Breathing and Obstructive Sleep Apnea, sponsored by Texas A&M University. Completed at 1 site in United States. Open to participants aged 18 Years and older, including healthy volunteers. Per ClinicalTrials.gov, last updated 2023-05-22.

Sponsored by Texas A&M University · Not applicable, Interventional, and Treatment

Phase
Not applicable
Study type
Interventional
Enrollment
89
Allocation
Randomized
Ages
18 Years and older
Sex
All
01

Study summary

Breathing is one of the body's vital functions that occur under normal conditions using the nose. When humans breathe primarily through the mouth instead of the nose, this is referred to as mouth breathing. Snoring and obstructive sleep apnea (OSA) occur frequently in mouth breathers. Mouth breathing impairs oral health, reduces quantity and quality of saliva, and increases dry mouth, risk of developing dental caries, gingival inflammation, bad breath and dry lips. Serious health conditions associated with an obstructed upper airway in those who snore include hypertension, cardiovascular disease and mild cognitive impairment.

Oral appliances (OAs) that bring the lower jaw (mandible) forward have been shown to be highly effective in reducing snoring and interruptions in breathing (respiratory events) that occur in those who snore and/or have OSA. The myTAP™ OA (AMI, Dallas, TX) includes an optional mouth shield (MS) that is anticipated to promote nasal breathing. The purpose of this study is to investigate the effects of oral appliance plus mouth shield therapy on sleep cardio-respiratory dynamics (breathing and heart activity) and their effect on improving OSA and oral health, especially of the periodontal tissues, in confirmed mouth breathers who snore and/or have OSA. As many as 70 adults at least 18 years old will be recruited to participate.

All participants will wear the OA during sleep for 8 weeks (Phase 1). Half of the participants will be randomly assigned to wear the OA only for the first 4 weeks; all will wear both the OA and MS for the last 4 weeks. Participants will wear an easy-to-use home sleep recording system (NOX T3) for 2 nights at the start of the study and again at 4 weeks and 8 weeks. Based on the investigators' experience, some participants will not have achieved maximal benefit from the OA at 8 weeks, and will require addition adjustment. These participants will enter a second phase of the study where they will have 1 or more sleep studies done at 2 week intervals, and will further adjust their OAs (that is, advance the mandible) to eliminate snoring.

Read the detailed description

Background: Respiration is one of the body's vital functions that occurs under normal conditions using the nose. When nasal breathing is supplemented by or supplanted through the mouth, this is referred to as mouth breathing. Primary snoring and obstructive sleep apnea (OSA) are frequent findings in mouth breathers, regardless of age. In children, mouth breathing is often associated with enlarged adenoids and tonsils, changes in body posture, hyperactivity, attention deficit and impaired learning. In all ages, mouth breathing impairs oral health, reduces quantity and quality of saliva, and increases dry mouth, risk of developing dental caries, gingival inflammation, bad breath and dry lips. Symptoms associated with an obstructed upper airway in those who snore include hypertension, cardiovascular disease and mild cognitive impairment. There are currently no data on the effects of oral appliance plus mouth shield therapy on sleep cardio-respiratory dynamics and their effect on improving OSA and oral health, especially periodontal health, in mouth breathers.

Methods: Evaluation of the effects of the FDA cleared MyTAP midline traction type oral appliance (OA; AMI, Dallas, TX) in combination with its FDA-cleared mouth shield (MS) in treating confirmed mouth breathers who snore and/or have OSA.

Power analysis: Sample size (n=40) is based on a-posteriori power of 80% observed in the investigative team's recently completed randomized controlled trial (RCT) comparing two OA designs. As many as 70 participants will be enrolled to account for drop-outs.

Design: Single center, prospective randomized clinical trial using a parallel group design.

Randomization: Using an online randomizer software, half of the subjects will be assigned to Group "OA plus MS 8wk", OA use with MS for 8-weeks and group "OA Alone 4wk" (no MS) for first 4-weeks. The OA Alone 4wk group will add MS use after 4-weeks and continue to use the combination for subsequent 4-weeks.

Clinically standard periodontal exams will be performed at baseline (T0), after 4-weeks (T2) and after 8 weeks (T3). The dentist-fitted OA will be applied chair-side and adjusted to a starting position of 60% of the lower jaw's maximum comfortable protrusion. All participants will wear the OA nightly during sleep for 8-consecutive weeks. Subjects will be instructed to advance the jaw up to 0.5 mm every 2 nights (less frequently if needed to minimize transient discomfort). Subjects will use the EverSleep Wearable Sleep Tracker app (Somno Health Inc., Golden CO) on their smart phones to monitor their own snoring nightly, and self-titrate their OAs until no snore detection is reported by the software.

Based on the investigators' recently completed study (IRB2017-0390) and another study published on this kind of appliance, some participants will not have achieved maximal benefit from the OA, and will require addition adjustment. These participants will enter Phase 2 of the study where they will have 1 or 2 more sleep studies done at 2 week intervals, and will further adjust their OAs (that is, advance their lower jaws) to eliminate snoring.

The investigators will evaluate differences in sleep respiration events, snoring and other measures at all time points except T1. Periodontal exams (gums and supporting tissues) will be performed at T1-T3 and T5. Comparison will be done between and within group (that is, with and without the MS) .

The purpose of collecting sleep data with OA use is to determine its success in promoting stable respiration during sleep and reducing the number of events in which breathing stops (apneas) or diminished (hypopneas) and the amount of oxygen in the blood is low (oxygen desaturation).

The sleep recorder (NOX T3, Nox Medical , Reykjavík, Iceland) is a Food and Drug Administration (FDA) cleared and certified for sale within the European Economic area (CE marked). The midline traction oral appliance (myTAP, AMI Inc., Dallas Texas) is currently marketed as a medical device to treat snoring and obstructive sleep apnea and is FDA cleared and CE marked. The EverSleep device (Somnohealth, Golden Colorado) is a wearable sleep coaching device and is not an FDA 510(k) cleared medical device.

02

Conditions studied

  • Snoring
  • Mouth Breathing
  • Obstructive Sleep Apnea

Keywords

  • oral appliance
  • mouth shield
  • snoring
03

Who can participate

Ages eligible
18 Years and older
Sexes eligible
All
Accepts healthy volunteers
Yes

Inclusion criteria

  1. At least 18 years old (adults \& seniors, male \& female).
  2. Presence of snoring, mouth-breathing or previously diagnosed with obstructive sleep apnea.
  3. If present, stable cardiopulmonary disease (heart failure, chronic obstructive pulmonary disease, ventricular dysrhythmia), morbid obesity or other serious health conditions, must be under a physician's care; participant must obtain written permission from the physician to participate in this study.
  4. If participated in recent OA clinical trial at the Texas A\&M University College of Dentistry (IRB# 2017-0390) must be willing to try the myTAP as alternative to OA that is currently being used. The myTAP is a chairside-fitted OA that may be more comfortable and effective than the previous OAs and includes a mouth-shield.
  5. At least 8 teeth per arch to support OA device.
  6. Mallampati score from I to III; palatine tonsils grade 0,1 or 2.
  7. Willing \& able to provide verbal \& written informed consent in English \& understand how to apply, remove \& utilize the sleep recorder \& the OA device, as well as fill out brief questionnaires \& nightly sleep diary.

Exclusion criteria

Exclusion Criteria:

  1. Unable or unwilling to complete the study demands \& schedule.
  2. Active temporomandibular joint dysfunction (TMD) or jaw muscle pain, morphological airway abnormalities.
  3. Severe restrictions in jaw opening.
  4. Pre-existing difficulty swallowing; throat or neck related health issues; unmanaged endocrine dysfunction.
  5. Severe chronic nasal obstruction that precludes possibility of nasal breathing.
  6. Severe psychiatric \& neurological disorders; intellectually disabled.
  7. Advanced periodontal disease (e.g., loose teeth).
  8. History of uvulopalatopharyngoplasty (UPPP) surgery.
  9. Loose teeth, loose crowns or fillings.
  10. Removable dentures or bridges.
  11. Temporary crowns.
  12. Orthodontic braces.
  13. Other oral conditions which would be adversely affected by wearing dental appliances.
04

Study design

Phase
Not applicable
Primary purpose
Treatment
Allocation
Randomized
Intervention model
Parallel assignment
Masking
Single (Outcomes assessor)
Enrollment
89 participants (actual)

Study arms

  • Experimental
    OA plus MS 8wk

    Oral Appliance plus Mouth Shield for 8-weeks

    Device: myTAP oral appliance plus mouth shield

  • Active comparator
    OA Alone 4wk

    Oral Appliance is used alone for first 4 weeks followed by 4 weeks of Oral Appliance plus Mouth Shield

    Device: myTAP oral appliance alone for first 4 weeks

Interventions

  • DevicemyTAP oral appliance plus mouth shield

    myTAP anti-snoring oral appliance worn with mouth shield for all 8-weeks; the mouth shield is a comfort accessory that fits over the oral appliance itself and extends into the oral vestibule.

    Also known as: anti-snoring device, midline traction oral appliance

  • DevicemyTAP oral appliance alone for first 4 weeks

    myTAP anti-snoring oral appliance worn alone for first 4 weeks followed by wearing it for 4 weeks with the mouth shield

    Also known as: anti-snoring device, midline traction oral appliance

05

What researchers measure

Primary outcomes

  1. Respiratory Event Index (REI) at T2

    Number of apneas and hypopneas per hour of recording using the NOX T3 sleep recording system at T2 (4 weeks). REI is reported instead of Apnea Hypopnea Index (AHI), as it is a more appropriate measure for home sleep testing. Apneas are scored when there is a 90% drop in the flow signal between 10 and 120 seconds. Hypopneas are scored when there is a 30% drop in flow signal between 10 and 120 seconds followed by either a drop in oxygen saturation or an arousal.

    Time frame: 4 weeks

06

Study locations

1 site
  • Texas A&M University College of Dentistry
    Dallas, Texas 75246, United States
07

References and documents

Publications

  • Hoekema A, Doff MH, de Bont LG, van der Hoeven JH, Wijkstra PJ, Pasma HR, Stegenga B. Predictors of obstructive sleep apnea-hypopnea treatment outcome. J Dent Res. 2007 Dec;86(12):1181-6. doi: 10.1177/154405910708601208. PubMed 18037652 ↗

Study documents

  • Informed consent form · Oct 23, 2020

Documents are hosted by the registry — open the source record to download them.

08

Registry details

Key details

Study ID
NCT04876625
Lead sponsor
Texas A&M University
Responsible party
Emet D. Schneiderman, PhD (Professor, Texas A&M University) — Principal investigator
First posted
May 6, 2021
Start date
Jul 26, 2019
Primary completion
Sep 25, 2021
Completion
Sep 25, 2022
Last update
May 22, 2023

Study contacts

Emet Schneiderman, PhD
principal investigator · Texas A&M University College of Dentistry

Oversight

Data monitoring committee
No
FDA-regulated drug
No
FDA-regulated device
Yes
View the source record on ClinicalTrials.gov ↗

Not currently enrolling

This study is completed, as verified in May 2023. You cannot join it, but the record below documents what was studied.

Follow this study

Get an email when the registry record changes — status, dates, results — or when someone posts here.

Sign in to follow

Discussion

Questions and observations about this study, from anyone following it. Not medical advice, and not a channel to the study team — their contact details are on the registry record.

Sign in to join the discussion. Reading takes no account; posting does. You choose a display name, and a pseudonym is the default.

Nothing here yet. If you are running this trial, taking part in it, or weighing whether to, this is the place to say so.

Start the discussion