An observational study in Cardiac Output, LIDCO Rapid, Septic Shock, sponsored by Cairo University. Completed at 1 site in Egypt. Open to participants aged 18 Years and older. Per ClinicalTrials.gov, last updated 2021-08-16.
Sponsored by Cairo University · Observational
Help build ClinicalTrials.gg — short surveys, remote interviews or testing, in your language. Take part →
Among 17 studies in Shock, Septic by Cairo University — 1 open to participants now, 1 under way, none of them phase 3. Shock, Septic · Cairo University.
Among the 17 studies in Shock, Septic by Cairo University, this one is one of 4 that started in 2019, is one of 6 observational ones, and was the 9th registered.
1,084 studies on the registry are indexed under Shock, Septic; 236 are open to participants now.
Browse Shock, Septic studies →1 of the 17 studies in Shock, Septic by Cairo University is open now, in 1 country. Recruiting first, the newest first:
Cairo University · Sites in Egypt
Ages 18–90
By country, each count listing its studies:
Of the 137 Shock, Septic studies recruiting now, 103 (75%) set no upper age limit and 18 (13%) stop at 75 or younger; 11 take children under 18; 14 take healthy volunteers.
This study: 18 Years and older · all sexes · no healthy volunteers.
The full table on the hub →This tab as a report to print or save as PDF → With an account.
17 studies; the count open now beside each. This study's row is marked.
First in 2017; this study’s year is marked. 4 started in 2019.
By drug class, each counting the studies that test any of its medicines:
This study's enrollment of 40 is below the median of 108 across 408 observational studies indexed under Shock, Septic.
Median enrollment 42 across the 11 interventional studies, 50 across the 6 observational. Of the 10 that completed or were terminated, 0 (0%) have results posted.
This tab as a report to print or save as PDF → With an account.
Cairo University is the lead sponsor of 4,973 studies on the registry; 1,478 are open to participants now.
Of its 37 completed or terminated interventional studies of FDA-regulated products, 5 (14%) have results posted.
None of the studies under way reaches primary completion within a year.
Among the 17 studies in Shock, Septic by Cairo University, from their registry updates:
This tab as a report to print or save as PDF → With an account.
Transthoracic echocardiography (TTE) has been used as a reference technique for CO measurement and its accuracy has been adequate for many clinical uses. TTE is painless, safe and non-invasive. Some drawbacks of TTE are being expensive, bulky and needs advanced training.
Currently, due to increased interest in minimally invasive hemodynamic monitoring, multiple new methods have become commercially available to assess CO: the arterial pulse aortic flow, bioreactance, and bioimpedance.
One of these new devices is LiDCOrapid (LiDCO Ltd, Cambridge, UK). It is a new, minimally invasive monitor which estimates beat-by-beat CO and fluid responsiveness from the arterial waveform.
It has been validated after vascular, urological and thoracic surgery and shows good agreement with the PA catheter in swine, in patients with normal left ventricular systolic function and in patients with vasodilatation. However, LiDCO has not yet been validated in patients with septic shock. Therefore, the aim of this study is to validate LiDCOrapid parameters in septic shock patients using TTE derived parameters as the non-invasive reference.
Obtaining a patient's cardiac output (CO) could contribute to optimized, safe hemodynamic control. Accurate CO measurements can serve as a guide for resuscitation therapy, catecholamine use, differential diagnosis, and intervention during a circulatory failure. Although the thermodilution technique via a pulmonary artery catheter (PAC) has an invasive and intermittent, it remains the gold standard for CO measurements.
Previously monitoring of CO required invasive and costly devices limiting their use to intensive care setting. More recently ultrasound is increasingly being used and offers a range of non-invasive tools to estimate CO.
Transthoracic echocardiography (TTE) has been used as a reference technique for CO measurement and its accuracy has been adequate for many clinical uses. TTE is painless, safe and non-invasive. Some drawbacks of TTE are being expensive, bulky and needs advanced training.
Currently, due to increased interest in minimally invasive hemodynamic monitoring, multiple new methods have become commercially available to assess CO: the arterial pulse aortic flow, bioreactance, and bioimpedance.
One of these new devices is LiDCOrapid (LiDCO Ltd, Cambridge, UK). It is a new, minimally invasive monitor which estimates beat-by-beat CO and fluid responsiveness from the arterial waveform.
It has been validated after vascular, urological and thoracic surgery and shows good agreement with the PA catheter in swine, in patients with normal left ventricular systolic function and in patients with vasodilatation. However, LiDCO has not yet been validated in patients with septic shock. Therefore, the aim of this study is to validate LiDCOrapid parameters in septic shock patients using TTE derived parameters as the non-invasive reference.
The study will be performed on any patient with septic shock admitted to the surgical ICU.
Go through the criteria one by one — yes, no or not sure — and take the list to your doctor or the study team. Kept in this browser only.
Exclusion Criteria:
Lidco rapid examination and echo examination were done to septic shock patients then the passive leg raising test was done and fluid responder cases were given mini fluid challenge and fluid challenge
Other: fluid resuscitation with crystalloid
give two-volume of fluids initial 250ml then another 250 ml
primary outcome
To measure cardiac output difference between LiDCOrapid measurement and echocardiographic measurement .
Time frame: on patient admission to the icu for 1 hour
secondary outcome
to measure dose of vasopressors and inotropic agents
Time frame: on patient admission to the icu for 1 hour
secondary outcome
to measure heart rate
Time frame: on patient admission to the icu for 1 hour
secondary outcome
to measure stroke volume
Time frame: on patient admission to the icu for 1 hour
secondary outcome
to detect stroke volume variation
Time frame: on patient admission to the icu for 1 hour
secondary outcome
to record mean arterial blood pressure
Time frame: on patient admission to the icu for 1 hour
Plan to share: Undecided
No publications or documents are linked to this record.
Ran from Dec 2019 to primary completion in Jul 2021, 19 months.
How these figures are worked out, and which studies are left out of them.
This study is completed, as verified in Aug 2021. You cannot join it, but the record below documents what was studied.
Get an email when the registry record changes — status, dates, results — or when someone posts here.
Sign in to followQuestions and observations about this study, from anyone following it. Not medical advice, and not a channel to the study team — their contact details are on the registry record.
Sign in to join the discussion. Reading takes no account; posting does. You choose a display name, and a pseudonym is the default.
Nothing here yet. If you are running this trial, taking part in it, or weighing whether to, this is the place to say so.