An interventional study of High Flow Nasal Cannula withAutomatic control of FiO2 using OAM and High Flow Nasal Cannula with manual control of FiO2 in Preterm Birth, sponsored by South Tees Hospitals NHS Foundation Trust. Status unknown at 1 site in United Kingdom. Open to participants aged 23 Weeks to 32 Weeks. Per ClinicalTrials.gov, last updated 2021-04-27.
Sponsored by South Tees Hospitals NHS Foundation Trust · Not applicable, Interventional, and Treatment
Oxygen treatment is common in babies born early (preterm) and requiring intensive care. Having too much or too little oxygen can increase the risk of damage to the eyes and lungs, and contribute to death or disability. Preterm infants because of their immaturity experience episodes of low oxygen levels. The low oxygen episodes are primarily due to pauses in their breathing (Apnoea of prematurity) and immaturity of their lung. These episodes persist for weeks to months. The lower the gestation at birth the longer the duration of these events. Studies have shown that these episodes of low oxygen saturations especially if frequent and prolonged is associated with poor developmental outcome, severe eye disease and lung disease.
Traditionally, the oxygen delivery is manually adjusted when infant has low oxygen saturation. However previous studies have shown despite the best efforts the oxygen level can only be maintained less than half of the time and nearly a one-fifth of the time infant spends in low oxygen levels and nearly one-third of the time in high oxygen levels. With advancement in the neonatal care, preterm infants tend to spend more time on non invasive respiratory support. Now it is possible to maintain oxygen level in target range by using automatic control of oxygen delivery on non invasive support. With the proposed study, we would like to study the efficacy of automatic control of oxygen delivery in reducing the time spent in very low and high oxygen levels when infants are on non invasive respiratory support namely High Flow Nasal Cannula support.
Supplemental oxygen remains by far the most commonly used 'drug' in neonatal intensive care units. The goal of oxygen therapy is to maintain normal oxygenation while minimizing hypoxemia and hypoxemia. Preterm infants are particularly vulnerable to oxygen toxicity and oxidative stress leading to retinopathy of prematurity (ROP), bronchopulmonary dysplasia (BPD), and periventricular leukomalacia (PVL). It's also well known that preterm infants experience hypoxic events which are primarily linked to cardiovascular instability and apnea of prematurity. These events vary as the infant matures. Martin R et al showed in their study that these hypoxic events peaked around 2-4 weeks and decreases by 6-8 weeks in preterm infants . Exposure to prolonged and frequent hypoxemic episodes has been associated with increased morbidity and mortality . Prolonged hypoxic events (Saturation less than 80% for more than 1 minute) have been associated with severe ROP and impaired neurodevelopmental outcome in survivors . Very high oxygen levels are equally harmful.
Peripheral oxygen saturation monitoring is standard of care in infants admitted to neonatal unit. Traditionally oxygen saturation (SpO2) targeting is carried out by manual adjustment of fraction of inspired oxygen (FiO2) by the caregiver based on the monitored oxygen saturation. However, in practice this is only partially achieved during routine care[6]. Hagadorn et al conducted a study in 14 centers and showed that preterm infants under 28 weeks' gestation receiving oxygen spent on average only 48% of the time with SpO2 within the prescribed target range, about 36% of the time above and 16% of the time with SpO2 below the target range.
Preterm infants have frequent fluctuations in SpO2 due to their cardio-respiratory instability requiring frequent adjustments of FiO2 . Consequently, these particularly vulnerable infants spend significant time with SpO2 outside intended range and are often exposed to extremes of hypoxemia and hyperoxaemia. The automatic oxygen control system continuously monitors the oxygen saturation and adjusts the oxygen delivery to maintain oxygen saturation within the target range. The safety, feasibility and efficacy of this mode of oxygen control have already been established. Automated control of FiO2 significantly improves compliance of oxygen saturation targeting and significantly reduces exposure to hypoxemia as well as hyperoxaemia. Automatic control of oxygen delivery is available in both invasive and non-invasive mode of ventilation. The HFNC Therapy is a common mode of non-invasive respiratory support in preterm infants. Oxygen Assist Module (OAM) is a system of automatic oxygen control available in the HFNC (Vapotherm Precision Flow).
Previous study looking at the efficacy of automated oxygen control with HFNC support mostly have been a crossover model and the study duration less than 48 hours . As previously mentioned, preterm infants experience hypoxic events for few weeks before cardiopulmonary maturation is established. Hence, it's important to study these events over a longer period of time. The objective of this randomized control trial is to evaluate the efficacy of OAM (Automatic oxygen Control) in reducing the extremes of oxygen saturations in preterm infants (\<80% and >98%) through the entire period of HFNC respiratory support.
2,554 studies on the registry are indexed under Premature Birth; 498 are open to participants now.
This study's planned enrollment of 60 is below the median of 84 across 1,689 interventional studies indexed under Premature Birth.
Browse Premature Birth studies →South Tees Hospitals NHS Foundation Trust is the lead sponsor of 17 studies on the registry; 2 are open to participants now.
Counted across the registry records on this site, refreshed daily.
Exclusion Criteria:
Infants randomized to this arm will be monitored using automatic oxygen control system on the High Flow Nasal Cannula. When infants oxygen saturation are out of the target range the OAM module on HFNC will adjust the oxygen delivery depending on the saturation of the infant to bring the saturation in the target range.
Device: High Flow Nasal Cannula withAutomatic control of FiO2 using OAM
Infants randomized to this arm will be receive oxygen delivery adjustments manually by the nursing and medical team taking care of the infants. When the infants oxygen saturation are out of the target range, the staff will manually adjust the oxygen delivery.
Device: High Flow Nasal Cannula with manual control of FiO2
The target oxygen saturation (SpO2) value will to be determined and set by the clinician according to specific patient needs. The target SpO2 in preterm infants is 90-95% with alarm limits at 89-96%. In automatic control of oxygen, the OAM automatically increases or decreases the FiO2 (oxygen delivery) setting on the Vapotherm Precision Flow based on pulse oximetry readings of the OAM. The target saturation will be set at 93% and the FiO2 will be adjusted by OAM to maintain the target saturation. The automated FiO2 setting can be overridden for a clinician pre-set period of time (30-120 sec) by simply manually adjusting the FiO2 on the Precision Flow. Automated control resumes after the clinicians pre-set period of time (30-120 sec) based on the current SpO2 and FiO2. The OAM utilizes a feedback control algorithm that receives a patient's oxygen saturation value from a build in pulse oximetry device (Masimo SET OEM - normal sensitivity, averaging time window set at 8 seconds).
In manual control of oxygen all FiO2 adjustments will be done by the clinical staff to maintain saturations between 90-95%. The alarm limits will be 89-96%.
Proportion of time spent in extreme saturation (<80% and >98%) in preterm infants receiving HFNC as respiratory support.
The primary outcome of this study is proportion of time spent in extreme saturation (\<80% and \>98%) in preterm infants receiving HFNC as respiratory support.
Time frame: Through study completion on an average of 3 months
Proportion of time spent in target saturation
Proportion of time spent in target saturation
Time frame: Through study completion on an average of 3 months
Proportion of time spent in saturation >95%
Proportion of time spent in saturation \>95%
Time frame: Through the study completion on an average of 3 months
episodes of prolonged hypoxemia (SpO2 < 80% for more than 60 sec)
episodes of prolonged hypoxemia (SpO2 \< 80% for more than 60 sec)
Time frame: Through study completion on an average of 3 months
Plan to share: No
This study is status unknown, as verified in Apr 2021. You cannot join it, but the record below documents what was studied.
Get an email when the registry record changes — status, dates, results — or when someone posts here.
Sign in to followQuestions and observations about this study, from anyone following it. Not medical advice, and not a channel to the study team — their contact details are on the registry record.
Sign in to join the discussion. Reading takes no account; posting does. You choose a display name, and a pseudonym is the default.
Nothing here yet. If you are running this trial, taking part in it, or weighing whether to, this is the place to say so.
South Tees Hospitals NHS Foundation Trust