An interventional study of MAKO THA 4.0 System in Osteoarthritis, Hip and Hip Disease, sponsored by American Hip Institute. Completed at 1 site in United States. Open to participants aged 18 Years and older. Per ClinicalTrials.gov, last updated 2025-01-29.
Sponsored by American Hip Institute · Not applicable, Interventional, and Treatment
Help build ClinicalTrials.gg — short surveys, remote interviews or testing, in your language. Take part →
Among 155 studies in Osteoarthritis, Hip with a site in United States — 21 open to participants now, 32 under way, 1 of them phase 3. Osteoarthritis, Hip · United States.
Among the 155 studies in Osteoarthritis, Hip with a site in United States, this one is the 99th largest by enrollment of the 118 interventional ones that give a count, is one of 13 that started in 2021, is one of 76 with no phase, and was the 115th registered.
642 studies on the registry are indexed under Osteoarthritis, Hip; 120 are open to participants now.
Browse Osteoarthritis, Hip studies →21 of the 155 studies in Osteoarthritis, Hip with a site in United States are open now. Recruiting first, the newest first:
The Cleveland Clinic · Sites in United States
Ages 18–75
Yale University · Sites in United States
Ages 18+
University of Sydney · Sites in United States, Australia
Ages 18+
Zimmer Biomet · Sites in United States
Ages 18+
F. Johannes Plate · Sites in United States
Ages 18+
A study can be open while its sites in United States have not opened yet or have stopped. Only those recruiting at a site in United States →
Of the 86 Osteoarthritis, Hip studies recruiting now, 53 (62%) set no upper age limit and 7 (8%) stop at 75 or younger; 3 take children under 18; 6 take healthy volunteers.
This study: 18 Years and older · all sexes · no healthy volunteers.
The full table on the hub →This tab as a report to print or save as PDF → With an account.
155 studies; the count open now beside each. This study's row is marked.
A study in two phases is counted once above. Listed by phase, each with its combined phases: Phase 1 7 · Phase 2 14 · Phase 3 18 · Phase 4 9
First in 2001; this study’s year is marked. 13 started in 2021.
By drug class, each counting the studies that test any of its medicines:
This study's enrollment of 35 is below the median of 90 across 458 interventional studies indexed under Osteoarthritis, Hip.
Median enrollment 105 across the 118 interventional studies, 120 across the 34 observational. Of the 106 that completed or were terminated, 49 (46%) have results posted.
This tab as a report to print or save as PDF → With an account.
51 of 155 have an industry lead sponsor. The 10 most frequent:
American Hip Institute is the lead sponsor of 8 studies on the registry; 4 are open to participants now.
American Hip Institute has 2 studies filed under Osteoarthritis, Hip — fewer than ten, so there is no comparison to draw.
5 of the studies in Osteoarthritis, Hip with a site in United States that are under way reach primary completion within a year, 1 of them phase 3. Phase 3 first, then by date:
| Study | Primary completion |
|---|---|
| NCT04990128Phase 3The Cleveland ClinicBone Marrow Aspirate Concentrate Versus Triamcinolone Injection For Hip Osteoarthritis | 2027-10 |
| NCT06778486University of California, DavisConversations in Health Literacy Using AI Technology for Osteoarthritis Patients | 2026-12 |
| NCT05675618Hospital for Special Surgery, New YorkReturn to Golf After Orthopaedic Surgery | 2026-12 |
| NCT04039386Michael C WilleyPsychosocial Interventions for Young Adults With Hip Pain | 2027-08-01 |
| NCT07104084F. Johannes PlateInfluence of Antiseptic Washes on Wound Healing Complications After THA | 2027-09-01 |
Add all 5 to your calendar (.ics) → With an account.
Among the 155 studies in Osteoarthritis, Hip with a site in United States, from their registry updates:
Nothing recorded among them since 2026-09-25.
This tab as a report to print or save as PDF → With an account.
The current study is a multi-center study to assess precision and accuracy of the robotic system with new software.
Robotic-arm assisted surgery aims to reduce errors and improve accuracy for implant position in total hip arthroplasty (THA). In THA implant positioning plays a pivotal role in good clinical outcomes and reduces long-term wear, therefore, technology has been developed to help surgeons achieve more accurate implant position consistently. Computer-assisted navigation provides surgeon with knowledge to help guide surgeons intra-operatively with some systems computed tomography (CT)-based, others fluoroscopy based, and others imageless systems. Computer navigation has been shown to accurately place components, but does not provide the ability for patient specific pre-operative planning that CT- based robotics allows. While some may argue that robotic-arm assisted THA is more accurate, others argue that the cost and learning curve associated with robotic-arm assisted THA is not more accurate with no long-term clinical benefits. Robotic arm-assisted THA has been shown to improve accuracy of component placement and reduce outliers. Kayani et al reviewed 100 cases performed by a single surgeon with 50 THAs performed manually and 50 robotic arm-assisted. In this study, Kayani did not find a learning curve associated with achieving accuracy using the robotic arm-assisted technology; however, there was a 12 case learning curve for both himself and his operating staff that increased operative time [9]. Nodzo et al evaluated the use of the robotic arm-assisted THA using post-operative CT scans and found that both the acetabular and femoral component position were significantly accurate when compared to the intra-op position. Kamara et al reviewed a single surgeon case series to assess acetabular accuracy and found that 76% of manual THAs were within the surgeons' target zone compared to 97% of his robotic arm-assisted THAs, concluding that adoption of robotic arm-assisted THA provided significant improvement in acetabular component positioning during THA. Similarly, Redmond et al found that although there was a learning curve associated with robotic arm-assisted THA, operative time decreased with experience and acetabular component outliers decreased suggesting that while there is a learning curve with robotic arm-assisted THA the clinical benefits are better implant positioning and decreased outliers. Illgen et al reported that the improved acetabular accuracy in robotic arm-assisted THA significantly reduced dislocation rates when compared to manual THA. Bukowski et al reported robotic arm-assisted THA clinical outcomes at a minimum of 1 year and found that patients who underwent a robotic arm-assisted THA has higher clinical outcomes compared to a manual group, however, there have been no large multicenter studies that assess clinical outcomes after robotic arm-assisted THA.
In conjunction with numerous other patient-specific and surgical factors, such as age, sex, comorbidities, surgical approach, component selection, and impingement, component positioning is often cited as an important factor in optimizing THA stability. Lewinnek et al. defined the "safe zone" for component position as 40⸰±10⸰ of cup inclination and 15⸰±10⸰ of cup anteversion to minimize dislocation risk. However, recent studies have shown that not only do components continue to dislocate when placed in this zone, but that the majority of THA dislocations are positioned in this safe zone to begin with. Compounding this issue is the growing body of evidence showing that the acetabular component is not static in nature, as was the assumption with Lewinnek's safe zone, but rather dynamically changing with movement of the pelvis and spine during postural and positional changes. Alterations of the dynamic relationship between the hip, spine, and pelvis in patients with hip-spine pathology during movements such as transitioning from standing to sitting affects typical pelvic biomechanical accommodation, resulting in THA component impingement, instability, and dislocation. Therefore, patients with spinopelvic pathology secondary to arthritis, spinal fusion, or spinal deformity are more prone to dislocation and revision following primary THA. The standard modality for assessing hip component position postoperatively is a 2D anteroposterior radiograph, due to low radiation dose and low cost. However, hip replacement components are placed in a 3-dimensional pelvis and femur, and therefore an anteroposterior radiograph alone may not give accurate information on the anteversion of the acetabular or femoral component. Studies have shown that cup anteversion measured with radiographs can have serious deviations with a substantial error range (mean deviation +1.74°, range -16.6° to 29.8°). This is attributed to the fact that radiographs cannot control for pelvic rotation and/or tilt. Recently a limited number of studies have started to use the other imaging modalities for understanding pelvic tilt in patients undergoing hip arthroplasty.
Go through the criteria one by one — yes, no or not sure — and take the list to your doctor or the study team. Kept in this browser only.
Exclusion Criteria:
Underlined terms in the criteria open these too. Explained by clinicaltrials.gg, not part of the registry record. The study team decides who can take part.
Before you join, the study team explains what taking part involves — its purpose, what happens, the risks and possible benefits — and answers your questions, so you can decide freely. Consent is usually recorded on a form (the informed consent form, ICF) signed by you or, where the law allows, by someone legally authorized to decide for you.
You can keep asking questions during the study, you are told of new information that matters, and you can choose to leave at any time.
Weight in kilograms divided by height in metres squared. Example: 70 kg and 1.75 m gives 70 ÷ (1.75 × 1.75) ≈ 22.9.
What counts as overweight or obesity differs between countries (some use lower cut-offs), so go by the range the study states.
Informed consent
Before you join, the study team explains what taking part involves — its purpose, what happens, the risks and possible benefits — and answers your questions, so you can decide freely. Consent is usually recorded on a form (the informed consent form, ICF) signed by you or, where the law allows, by someone legally authorized to decide for you.
You can keep asking questions during the study, you are told of new information that matters, and you can choose to leave at any time.
Explained by clinicaltrials.gg, not part of the registry record. The study team decides who can take part.
BMI (body mass index)
Weight in kilograms divided by height in metres squared. Example: 70 kg and 1.75 m gives 70 ÷ (1.75 × 1.75) ≈ 22.9.
What counts as overweight or obesity differs between countries (some use lower cut-offs), so go by the range the study states.
Explained by clinicaltrials.gg, not part of the registry record. The study team decides who can take part.
Hip system used: femoral stem (Accolade II), acetabular cup (Trident II or MDM if necessary), femoral head (ceramic or metal head compatible with Accolade II), acetabular insert (X3 Trident II or MDM liner when using MDM cup). Mako THA 4.0 software also will be used.
Device: MAKO THA 4.0 System
Measure how the accuracy and precision of robotic arm-assisted total hip arthroplasty (THA) for placement accuracy of implant position in both the anterior and posterior approach.. The intervention will assess the precision of the MAKO system in placing hip components according to plan. It will compare hip angles executed by the Mako system intraoperatively with the 'gold standard' of 3D computer tomography (CT) scans. The postoperative CT scan can show the precision of the MAKO system by accurately determining the location of hip replacements in patients after surgery.
Computed Tomography scan. Placement accuracy of acetabular cup and femoral stem
Using computed tomography to assess placement accuracy, Measured in degrees
Time frame: 6 weeks postoperatively
Pelvic tilt
measured preoperatively and intraoperatively in sitting and standing positions
Time frame: Preoperatively and postoperatively at 6 weeks and 1 year
Virtual range-of-motion
measured preoperatively and intraoperatively in sitting and standing positions using virtual range of motion impingement modeling
Time frame: Preoperatively and postoperatively at 6 weeks and 1 year
Patient satisfaction
Measured in a scale of 0-10 to determine how satisfied a patient is with their procedure. A score of 10 indicates most satisfied, a score of 0 is least satisfied.
Time frame: 1 year postoperative
Harris Hip Score
Questionnaire. A measure of functionality of the operated hip. Measured scale: 0-100. Lower score means worse functional outcome.
Time frame: preoperative and 1 year postoperative
Forgotten Joint Score
Assess likelihood the patient has forgotten that they had a hip replacement. Measured scale: 0-100. Higher score means better feeling of normalcy.
Time frame: 1 year postoperative
Hip Disability and Osteoarthritis Outcome Score
Assess pain and function. Measured scale: 0-100. Higher the score, the greater the outcome and patient experience.
Time frame: 1 year postoperative
Plan to share: No
Ran from Jan 2021 to primary completion in Oct 2024, 45 months.
Of 201 non-industry interventional studies with no phase under Osteoarthritis, Hip, half reached primary completion within 28 months of starting (the median), counting those still running; a quarter within 12 and three quarters within 45. This study's 45 months is above that.
Counting every sponsor, half of 227 studies reached it within 29 months; a quarter within 14 and three quarters within 52.
How these figures are worked out, and which studies are left out of them.
This study is completed, as verified in Jan 2025. You cannot join it, but the record below documents what was studied.
Get an email when the registry record changes — status, dates, results — or when someone posts here.
Sign in to followQuestions and observations about this study, from anyone following it. Not medical advice, and not a channel to the study team — their contact details are on the registry record.
Sign in to join the discussion. Reading takes no account; posting does. You choose a display name, and a pseudonym is the default.
Nothing here yet. If you are running this trial, taking part in it, or weighing whether to, this is the place to say so.
American Hip Institute