ClinicalTrials.gg
CompletedNCT04646096Updated Jan 29, 2025

Multicenter Study for Robotic Arm-assisted THA 4.0 System: Hip Spine Relationship

An interventional study of MAKO THA 4.0 System in Osteoarthritis, Hip and Hip Disease, sponsored by American Hip Institute. Completed at 1 site in United States. Open to participants aged 18 Years and older. Per ClinicalTrials.gov, last updated 2025-01-29.

Sponsored by American Hip Institute · Not applicable, Interventional, and Treatment

How we know

From the registry’s dates

  • Primary completion was Oct 2024, 2 years 1 month ago, and no results have been posted to the registry.

Help build ClinicalTrials.gg — short surveys, remote interviews or testing, in your language. Take part →

Phase
Not applicable
Study type
Interventional
Enrollment
35
Allocation
Not applicable
Ages
18 Years and older
Sex
All
01

Where this study stands

Counted across the records on this site · 2026-11-24

Among 155 studies in Osteoarthritis, Hip with a site in United States — 21 open to participants now, 32 under way, 1 of them phase 3. Osteoarthritis, Hip · United States.

Enrollment
99th of 118
35 · median 105
Started
2021
with 12 others
No phase
76 of 155
12 open now
Registered
115th of 155
by date

Among the 155 studies in Osteoarthritis, Hip with a site in United States, this one is the 99th largest by enrollment of the 118 interventional ones that give a count, is one of 13 that started in 2021, is one of 76 with no phase, and was the 115th registered.

Osteoarthritis, Hip

642 studies on the registry are indexed under Osteoarthritis, Hip; 120 are open to participants now.

Browse Osteoarthritis, Hip studies →

Open to participants now

21 of the 155 studies in Osteoarthritis, Hip with a site in United States are open now. Recruiting first, the newest first:

16 more — sign in →

All 21 open studies →

A study can be open while its sites in United States have not opened yet or have stopped. Only those recruiting at a site in United States →

Who these studies take

Of the 86 Osteoarthritis, Hip studies recruiting now, 53 (62%) set no upper age limit and 7 (8%) stop at 75 or younger; 3 take children under 18; 6 take healthy volunteers.

This study: 18 Years and older · all sexes · no healthy volunteers.

The full table on the hub →

This tab as a report to print or save as PDF → With an account.

Was this useful?
Get alerts for this landscapeDownload CSVNarrow it in search →With an account: a weekly mail of what changed among 155 studies in Osteoarthritis, Hip with a site in United States, or all of them as a file.
02

Study summary

The current study is a multi-center study to assess precision and accuracy of the robotic system with new software.

Read the detailed description

Robotic-arm assisted surgery aims to reduce errors and improve accuracy for implant position in total hip arthroplasty (THA). In THA implant positioning plays a pivotal role in good clinical outcomes and reduces long-term wear, therefore, technology has been developed to help surgeons achieve more accurate implant position consistently. Computer-assisted navigation provides surgeon with knowledge to help guide surgeons intra-operatively with some systems computed tomography (CT)-based, others fluoroscopy based, and others imageless systems. Computer navigation has been shown to accurately place components, but does not provide the ability for patient specific pre-operative planning that CT- based robotics allows. While some may argue that robotic-arm assisted THA is more accurate, others argue that the cost and learning curve associated with robotic-arm assisted THA is not more accurate with no long-term clinical benefits. Robotic arm-assisted THA has been shown to improve accuracy of component placement and reduce outliers. Kayani et al reviewed 100 cases performed by a single surgeon with 50 THAs performed manually and 50 robotic arm-assisted. In this study, Kayani did not find a learning curve associated with achieving accuracy using the robotic arm-assisted technology; however, there was a 12 case learning curve for both himself and his operating staff that increased operative time [9]. Nodzo et al evaluated the use of the robotic arm-assisted THA using post-operative CT scans and found that both the acetabular and femoral component position were significantly accurate when compared to the intra-op position. Kamara et al reviewed a single surgeon case series to assess acetabular accuracy and found that 76% of manual THAs were within the surgeons' target zone compared to 97% of his robotic arm-assisted THAs, concluding that adoption of robotic arm-assisted THA provided significant improvement in acetabular component positioning during THA. Similarly, Redmond et al found that although there was a learning curve associated with robotic arm-assisted THA, operative time decreased with experience and acetabular component outliers decreased suggesting that while there is a learning curve with robotic arm-assisted THA the clinical benefits are better implant positioning and decreased outliers. Illgen et al reported that the improved acetabular accuracy in robotic arm-assisted THA significantly reduced dislocation rates when compared to manual THA. Bukowski et al reported robotic arm-assisted THA clinical outcomes at a minimum of 1 year and found that patients who underwent a robotic arm-assisted THA has higher clinical outcomes compared to a manual group, however, there have been no large multicenter studies that assess clinical outcomes after robotic arm-assisted THA.

In conjunction with numerous other patient-specific and surgical factors, such as age, sex, comorbidities, surgical approach, component selection, and impingement, component positioning is often cited as an important factor in optimizing THA stability. Lewinnek et al. defined the "safe zone" for component position as 40⸰±10⸰ of cup inclination and 15⸰±10⸰ of cup anteversion to minimize dislocation risk. However, recent studies have shown that not only do components continue to dislocate when placed in this zone, but that the majority of THA dislocations are positioned in this safe zone to begin with. Compounding this issue is the growing body of evidence showing that the acetabular component is not static in nature, as was the assumption with Lewinnek's safe zone, but rather dynamically changing with movement of the pelvis and spine during postural and positional changes. Alterations of the dynamic relationship between the hip, spine, and pelvis in patients with hip-spine pathology during movements such as transitioning from standing to sitting affects typical pelvic biomechanical accommodation, resulting in THA component impingement, instability, and dislocation. Therefore, patients with spinopelvic pathology secondary to arthritis, spinal fusion, or spinal deformity are more prone to dislocation and revision following primary THA. The standard modality for assessing hip component position postoperatively is a 2D anteroposterior radiograph, due to low radiation dose and low cost. However, hip replacement components are placed in a 3-dimensional pelvis and femur, and therefore an anteroposterior radiograph alone may not give accurate information on the anteversion of the acetabular or femoral component. Studies have shown that cup anteversion measured with radiographs can have serious deviations with a substantial error range (mean deviation +1.74°, range -16.6° to 29.8°). This is attributed to the fact that radiographs cannot control for pelvic rotation and/or tilt. Recently a limited number of studies have started to use the other imaging modalities for understanding pelvic tilt in patients undergoing hip arthroplasty.

03

Conditions studied

  • Osteoarthritis, Hip
  • Hip Disease

Browse trials for

Keywords

  • Robotic-assisted Total Hip Arthroplasty
  • MAKOplasty
04

Who can participate

Ages eligible
18 Years and older
Sexes eligible
All
Accepts healthy volunteers
No

Go through the criteria one by one — yes, no or not sure — and take the list to your doctor or the study team. Kept in this browser only.

Inclusion criteria

  • Requires primary total hip arthroplasty surgery
  • Willing and able to comply with postoperative follow up requirements
  • at least 18 years of age
  • sign an IRB approved

Exclusion criteria

Exclusion Criteria:

  • >40
  • Skeletally immature
  • patient with active infection or suspected latent infection in or about joint
  • bone stock inadequate for support or fixation of the prosthesis
  • Neuromuscular disorders, muscle atrophy, or vascular deficient in the affected limb
  • Ankylosing spondylitis
Terms in these criteria, in plain language(2)

Underlined terms in the criteria open these too. Explained by clinicaltrials.gg, not part of the registry record. The study team decides who can take part.

Informed consent

Before you join, the study team explains what taking part involves — its purpose, what happens, the risks and possible benefits — and answers your questions, so you can decide freely. Consent is usually recorded on a form (the informed consent form, ICF) signed by you or, where the law allows, by someone legally authorized to decide for you.

You can keep asking questions during the study, you are told of new information that matters, and you can choose to leave at any time.

BMI (body mass index)

Weight in kilograms divided by height in metres squared. Example: 70 kg and 1.75 m gives 70 ÷ (1.75 × 1.75) ≈ 22.9.

What counts as overweight or obesity differs between countries (some use lower cut-offs), so go by the range the study states.

05

Study design

Phase
Not applicable
Primary purpose
Treatment
Allocation
Not applicable
Intervention model
Single group
Masking
None (open label)
Enrollment
35 participants (actual)

Study arms

  • Experimental
    Mako THA 4.0 group

    Hip system used: femoral stem (Accolade II), acetabular cup (Trident II or MDM if necessary), femoral head (ceramic or metal head compatible with Accolade II), acetabular insert (X3 Trident II or MDM liner when using MDM cup). Mako THA 4.0 software also will be used.

    Device: MAKO THA 4.0 System

Interventions

  • DeviceMAKO THA 4.0 System

    Measure how the accuracy and precision of robotic arm-assisted total hip arthroplasty (THA) for placement accuracy of implant position in both the anterior and posterior approach.. The intervention will assess the precision of the MAKO system in placing hip components according to plan. It will compare hip angles executed by the Mako system intraoperatively with the 'gold standard' of 3D computer tomography (CT) scans. The postoperative CT scan can show the precision of the MAKO system by accurately determining the location of hip replacements in patients after surgery.

06

What researchers measure

Primary outcomes

  1. Computed Tomography scan. Placement accuracy of acetabular cup and femoral stem

    Using computed tomography to assess placement accuracy, Measured in degrees

    Time frame: 6 weeks postoperatively

Secondary outcomes

  1. Pelvic tilt

    measured preoperatively and intraoperatively in sitting and standing positions

    Time frame: Preoperatively and postoperatively at 6 weeks and 1 year

  2. Virtual range-of-motion

    measured preoperatively and intraoperatively in sitting and standing positions using virtual range of motion impingement modeling

    Time frame: Preoperatively and postoperatively at 6 weeks and 1 year

  3. Patient satisfaction

    Measured in a scale of 0-10 to determine how satisfied a patient is with their procedure. A score of 10 indicates most satisfied, a score of 0 is least satisfied.

    Time frame: 1 year postoperative

  4. Harris Hip Score

    Questionnaire. A measure of functionality of the operated hip. Measured scale: 0-100. Lower score means worse functional outcome.

    Time frame: preoperative and 1 year postoperative

  5. Forgotten Joint Score

    Assess likelihood the patient has forgotten that they had a hip replacement. Measured scale: 0-100. Higher score means better feeling of normalcy.

    Time frame: 1 year postoperative

  6. Hip Disability and Osteoarthritis Outcome Score

    Assess pain and function. Measured scale: 0-100. Higher the score, the greater the outcome and patient experience.

    Time frame: 1 year postoperative

07

Study locations

1 site
  • American Hip Institute
    Des Plaines, Illinois 60018, United States
08

References and documents

Publications

  • Nodzo SR, Chang CC, Carroll KM, Barlow BT, Banks SA, Padgett DE, Mayman DJ, Jerabek SA. Intraoperative placement of total hip arthroplasty components with robotic-arm assisted technology correlates with postoperative implant position: a CT-based study. Bone Joint J. 2018 Oct;100-B(10):1303-1309. doi: 10.1302/0301-620X.100B10-BJJ-2018-0201.R1. PubMed 30295538 ↗

Individual participant data

Plan to share: No

09

Timeline

Tracking since Sep 25, 2026
ElapsedEstimatedEstimated, not yet reachedSimilar studies: half by the dot; the band is the middle halfHalf of similar studies reached it by the dot; the band is the middle half, from a quarter to three quarters

Ran from Jan 2021 to primary completion in Oct 2024, 45 months.

Of 201 non-industry interventional studies with no phase under Osteoarthritis, Hip, half reached primary completion within 28 months of starting (the median), counting those still running; a quarter within 12 and three quarters within 45. This study's 45 months is above that.

Counting every sponsor, half of 227 studies reached it within 29 months; a quarter within 14 and three quarters within 52.

How these figures are worked out, and which studies are left out of them.

Registered
Nov 18, 2020
First posted
Nov 27, 2020
StartActual
Jan 1, 2021
Primary completionActual
Oct 10, 2024
CompletionActual
Oct 10, 2024
Last update
Jan 29, 2025
What these dates mean
Start.
When the first participant enrolled; while estimated, when the study expects to open to recruitment.
Primary completion.
When the last participant was examined or treated to collect data for the study's main question, its primary outcome. A study that stopped early gives the date its data collection stopped.
Completion.
When the last participant's last visit took place, for every outcome, secondary ones and side effects included: the end of the study. Often later than primary completion, sometimes the same day.
Actual and Est.
Actual means the registry says the date has happened. Est. (estimated) is a date the sponsor plans or expects. It can still move, and the sponsor is expected to change it to actual once it has passed.
No changes since tracking began. The registry record was last updated on Jan 29, 2025, before this site started recording changes on Sep 25, 2026. Its history is on ClinicalTrials.gov ↗
10

Registry details

Key details

Study ID
NCT04646096
Lead sponsor
American Hip Institute
Responsible party
Benjamin Domb, MD (Medical Doctor, American Hip Institute) — Principal investigator
First posted
Nov 27, 2020
Start date
Jan 1, 2021
Primary completion
Oct 10, 2024
Completion
Oct 10, 2024
Last update
Jan 29, 2025

Study contacts

Benjamin G Domb, MD
principal investigator · American Hip Institute

Oversight

Data monitoring committee
No
FDA-regulated drug
No
FDA-regulated device
Yes
View the source record on ClinicalTrials.gov ↗

Not currently enrolling

This study is completed, as verified in Jan 2025. You cannot join it, but the record below documents what was studied.

Follow this study

Get an email when the registry record changes — status, dates, results — or when someone posts here.

Sign in to follow

Discussion

Questions and observations about this study, from anyone following it. Not medical advice, and not a channel to the study team — their contact details are on the registry record.

Sign in to join the discussion. Reading takes no account; posting does. You choose a display name, and a pseudonym is the default.

Nothing here yet. If you are running this trial, taking part in it, or weighing whether to, this is the place to say so.

Start the discussion