CClinicalTrials.gg
Active, not recruitingNCT04265222Updated Aug 1, 2024

Cam Decompression Utilizing the Stryker Hip-Check Software Platform

An interventional study of Hipcheck Software and Conventional Fluoroscopy in Femoroacetabular Impingement, sponsored by American Hip Institute. Active, not recruiting at 1 site in United States. Open to participants aged 18 Years to 50 Years. Per ClinicalTrials.gov, last updated 2024-08-01.

Sponsored by American Hip Institute · Not applicable, Interventional, and Treatment

From the registry’s dates

  • Primary completion was expected by Dec 2024, 1 year 10 months ago, but the record still lists the study as active, not recruiting.
Phase
Not applicable
Study type
Interventional
Enrollment
43
Allocation
Randomized
Ages
18 Years to 50 Years
Sex
All
01

Study summary

Accurate femoroplasty has been shown to be critical in achieving success following treatment of femoroacetabular impingement (Matsuda, Schnieder, and Sehgal 2014; Mansor et al. 2018; Larson et al. 2014). Nearly 75% of cases undergoing revision hip arthroscopy do so due to residual femoroacetabular impingement (Ricciardi et al. 2014). Femoroplasty remains one of the most challenging and time-consuming procedures in hip arthroscopy and methods to improve accuracy and optimize time management are essential. The HipCheck system is a navigational tool based on intraoperative fluoroscopy that aims at improving accuracy and efficiency of femoroplasty.

The objective of this study is to two-fold. (1) To prospectively compare surgical and (2) radiographic outcomes of patients undergoing femoroplasty with guidance of Stryker's HipCheck system to patients undergoing femoroplasty with conventional fluoroscopic methods.

Read the detailed description

The purpose of this study is to prospectively compare surgical and radiographic outcomes of patients undergoing femoroplasty with guidance of Stryker's HipCheck system to patients undergoing femoroplasty with conventional fluoroscopic methods.

Endpoints:

Time from initiation to completion of femoroplasty Accuracy of femoroplasty as determined by: alpha angle on Dunn view and AP view, femoral head offset, and area of over resection and under resection Fluoroscopic exposure (microgray and seconds) Post-operative opioid consumption/medication use

Basic design: Randomized Controlled Study

Participants: 40 patients 20 patients will undergo femoroplasty with the conventional technique 20 patients will undergo femoroplasty with the HipCheck system

Accurate femoroplasty has been shown to be critical in achieving success following treatment of femoroacetabular impingement (FAI).1-3 Nearly 75% of cases undergoing revision hip arthroscopy do so due to residual FAI. Matsuda et al. coined the term "critical corner" to describe residual impingement not resected during routine anterolateral femoroplasty. These residual cam lesions have been shown to lead to inferior outcomes and are commonly implicated in revision hip arthroscopies. These studies and others contributed to the development of the "spherical femoroplasty" as an attempt to minimize residual cam lesions while simultaneously, avoiding over-resection. Femoroplasty remains one of the most challenging and time-consuming procedures in hip arthroscopy and methods to improve accuracy and optimize time management are essential.

General Schema of Study Design Overview Patients will be randomly assigned to undergo femoroplasty either with a conventional technique or a navigational method involving the HipCheck system. Preoperatively, the patient will undergo a series of standard radiographs to assess the degree of deformity. At this time, ROM will also be assessed. During surgery time required for femoroplasty as well as total fluoroscopic exposure time, as well as total exposure in microgray will be recorded. At 2 weeks postoperatively patient will undergo a series of standard radiographs to assess accuracy of femoroplasty. Narcotic medication use, pain levels and patient-reported outcome scores (PROs) will be assessed at 2 weeks, 3 months, 6 months, and 12 months postoperatively. A clinical exam will be performed postoperatively at each visit, consisting of hip range of motion (internal/external rotation, flexion, abduction, and adduction) with the patient in the supine position, impingement tests, and gait. Radiographic measurements will be performed using the institutional PACS system as well as ImageJ for surface area calculations. The patients as well as the clinician performing postoperative radiographic calculations will be blinded to method of treatment.

The total duration of the study is 1 year and 6 months:

Legal contract \& IRB review: 8 weeks Patients recruitment/procedure: 8 weeks Follow up period: 1 year Manuscript writing/submission: 8 weeks

Data Sources Research resources: Research data will be collected and recorded by study personnel designated by the Investigator.

Study Procedures

Pre-Operative A series of standard radiographs (Dunn, AP, False profile views) will be taken to understand the severity of the cam-type impingement. A clinical exam including but not limited to the following will be performed: gait (antalgic, Trendelenburg) hip range of motion (internal/external rotation, flexion, abduction, and adduction) with the patient in the supine position; anterior, posterior and lateral impingement tests; painful internal/external snapping test, FABER's test, Modified Resisted Internal rotation test, Ligamentum Teres test.

Pre-operative patient-reported outcome scores (PROs) and Visual Analog Pain Scale (VAS) will be taken during screening. The PROs include: mHHS, modified Harris Hip Score; NAHS, Nonarthritic Hip Score; iHOT-12, International Hip Outcome Tool; SF-12M, Short Form 12 Mental; SF-12P, Short Form 12-Physical; VR-12M, Veterans RAND 12-Item Health Survey Mental; VR-12P, Veterans RAND 12-Item Health Survey Physical; and Patient satisfaction (out of 10).

Intra-Operative During surgery - time required for femoroplasty as well as total fluoroscopic exposure time, as well as total exposure in microgray will be recorded. Procedural start (at initiation of femoroplasty) and finish (at completion of femoroplasty) time will be recorded for comparative analysis of both groups. Fluoroscopic exposure time and total exposure in microgray will be determined based on total number of shots taken and known duration/microgray exposure of each fluoroscopic shot. Fluoroscopic shot duration/Microgray exposure: mean total fluoroscopy time will be limited to 1.10 minutes or less (52 mGy or less per patient), based on recommendations by Budd et al. 2012

Intraoperative Fluoroscopic Image Acquisition Each patient will be placed in a neutral position to allow for the standardization and comparison with the well-centered, preoperative anteroposterior (AP) pelvic radiographs that are typically used for structural analysis and treatment planning.

Once the fluoroscopic image most closely replicates the AP pelvis, the femoral head-neck junction (FHNJ) will be assessed with fluoroscopy, with the leg in 6 different positions and fluoroscopic C-arm in 3 different positions (see table below) that allow for the evaluation of the medial and lateral FHNJ (extension views) and anterior and posterior FHNJ (flexion views). These views will be obtained by rotating the operative distal femur, flexing/extending the operative hip, and/or adducting the operative hip.

For all six positions, the angle of rotation will be verified with a Goniometer (Prestige Medical, Northridge, CA).

Measurements of the alpha angle will be performed by a single reader on each exported fluoroscopic view (corresponding to the six positions) for every control specimen with the use of the HipCheck System. For the control group the surgeon will review the fluoroscopic images prior to the resection procedure, but without making or reviewing any measurements or analysis (The HipCheck analysis platform will have "alpha angle overlay" turned off, to keep measurements from being displayed). For the HipCheck group the surgeon will review the fluoroscopic images including the HipCheck analysis for each view prior to resection.

Hip Arthroscopy (femoroplasty):

Femoroplasty will be performed using a 5.5 mm bur. This will be done in combination with the aid of fluoroscopic visualization and HipCheck technology or isolated fluoroscopic visualization, depending on the patient group assignment.

The HipCheck system will be used intraoperatively to assist with clinical decision making by assessing and providing feedback on alpha angle and confirming complete bony resection and absence of residual deformity for the test group only. To prevent over- or under resection, HipCheck provides a resection line (spline) for the surgeon to visualize and resect the desired amount, with a target alpha angle of 40 degrees.

The control group will not receive intra-operative assistance from the HipCheck software platform. Both arthroscopic and fluoroscopic imaging will be used to identify the cam and aid in resection per the standard hip arthroscopy technique.

"Postoperative" Fluoroscopic Image Acquisition At the conclusion of the hip arthroscopy, postoperative fluoroscopy views will be obtained with the same six leg positions. The angle of rotation will be verified with a Goniometer (Prestige Medical, Northridge, CA). The HipCheck tablet and software may be used to capture and later analyze the alpha angle for each of these leg positions for both the control and test groups.

Post-Operative At 2 weeks postoperatively patients will undergo a series of standard radiographs (Dunn, AP, False profile views) to assess accuracy of femoroplasty. Measurements will be performed using the institutional PACS system as well as ImageJ for surface area calculations. Accuracy of femoroplasty will be determined by: alpha angle on Dunn, AP views and false profile, femoral head offset, and area of over resection and under resection on AP. The patients as well as the clinician performing postoperative radiographic calculations will be blinded to method of treatment. A post-operative PROs and VAS Pain Score will be taken at 2 weeks, 3 months, 6 months, and 12 months post-operatively. Medication use will be documented in post-op recovery, at 2 weeks, 3months, and 12 months post-operatively. A clinical exam including range of motion assessment will be performed at 2-week, 3-, 6-, and 12-month follow-up visits.

Subject Inclusion Criteria

Candidates for this study must meet ALL of the following criteria:

  1. Patients undergoing hip arthroscopy; aged 18-50 years old.
  2. Radiographic evidence of a cam lesion as defined by an alpha angle greater than 60 degrees as measured on the Dunn X-ray.
  3. Failure of non-conservative management

Subject Exclusion Criteria

Candidates will be excluded from the study if ANY of the following apply:

  1. Unwilling to participate
  2. History of prior hip conditions such as slipped capital femoral epiphysis, Legg-Calvé-Perthes disease, idiopathic avascular necrosis, hip joint trauma, and prior hip surgeries
  3. The presence of a concurrent systemic inflammatory arthritis such as rheumatoid arthritis; psoriatic arthritis, ankylosing spondylitis, juvenile idiopathic arthritis, or systemic lupus erythematosus
  4. Marked osteoarthritis (Tönnis grade 2 or higher)
  5. Subject is considered a part of a vulnerable population
  6. Pregnancy in order to avoid: x-rays and the contraindication of lying supine after 20 weeks secondary to pressure on the abdominal aorta

Subject Withdrawal Criteria Subjects may voluntarily withdraw from the study at any time for any reason. The Investigator may elect at any time to withdraw a subject from the study for any reason if such a decision is in the subject's best medical interest. If a patient discontinues the study or is withdrawn by the Investigator prior to surgery, the patient will not be counted as a completed subject and an additional subject may be enrolled to achieve the enrollment goal of 40 completed subjects.

Data Management Use established data registry and collection methodology. All preoperative and demographic data is collected and inputted into registry preoperatively. Intraoperative data and measurements are collected and inputted at time of surgery. Postoperative radiographic measurements to assess alpha angle and combined femoral offset are made within 3 months postoperatively, using a 2nd independent reader to verify inter- and intra-observer reliability.

Intraoperative data and postoperative complications are collected using OBERD system.

Risks Generalized risks to surgical procedures are present, which include but are not limited to bleeding, infection, injury to surrounding structures such as blood vessels, nerves, tendons, and bone. In addition, risks specific to hip arthroscopy include those related to hip traction related issues such as numbness and parasthesias to the perineum or soft tissue compression related complications. Lastly, risk to radiation exposure is present, however, it is limited with the use of HipCheck, as continuous fluoroscopy is not needed.

Benefits Enhanced verification of intraoperative cam resection via minimal fluoroscopic exposure. In addition, increased accuracy of cam resection with the goals of avoiding over or underresection, will thereby potentially improve patient outcomes following hip arthroscopy.

02

Conditions studied

  • Femoroacetabular Impingement

Keywords

  • Orthopedics
  • Cam Decompression
  • Femoroplasty
  • Femoroacetabular Impingement
03

In context

Femoracetabular Impingement

108 studies on the registry are indexed under Femoracetabular Impingement; 35 are open to participants now.

This study's enrollment of 43 is below the median of 75 across 63 interventional studies indexed under Femoracetabular Impingement.

Browse Femoracetabular Impingement studies →

Lead sponsor

American Hip Institute is the lead sponsor of 8 studies on the registry; 4 are open to participants now.

Counted across the registry records on this site, refreshed daily.

04

Who can participate

Ages eligible
18 Years to 50 Years
Sexes eligible
All
Accepts healthy volunteers
No

Inclusion criteria

Candidates for this study must meet ALL of the following criteria:

  • Patients undergoing hip arthroscopy; aged 18-50 years old
  • Radiographic evidence of a cam lesion as defined by an alpha angle greater than 60 degrees as measured on the Dunn X-ray.
  • Failure of non-conservative management

Exclusion criteria

Exclusion Criteria:

Candidates will be excluded from the study if ANY of the following apply:

  • Unwilling to participate
  • History of prior hip conditions such as slipped capital femoral epiphysis, Legg-Calve-Perthes disease, idiopathic avascular necrosis, hip joint trauma, and prior hip surgeries
  • The presence of a concurrent systemic inflammatory arthritis such as rheumatoid arthritis; psoriatic arthritis, ankylosing spondylitis, juvenile idiopathic arthritis, or systemic lupus erythematosus
  • Marked osteoarthritis (Tönnis grade 2 or higher)
  • Subject is considered a part of a vulnerable population
  • Pregnancy in order to avoid: x-rays and the contraindication of lying supine after 20 weeks secondary to pressure on the abdominal aorta
05

Study design

Phase
Not applicable
Primary purpose
Treatment
Allocation
Randomized
Intervention model
Parallel assignment
Masking
Double (Participant, Outcomes assessor)
Enrollment
43 participants (actual)

Study arms

  • Other
    Conventional Fluoroscopy

    Participants undergoing femoroplasty with conventional treatment

    Other: Conventional Fluoroscopy

  • Experimental
    HipCheck

    Participants undergoing femoroplasty with Stryker HipCheck System

    Device: Hipcheck Software

Interventions

  • DeviceHipcheck Software

    Software

    Also known as: Stryker HipCheck system

  • OtherConventional Fluoroscopy

    Conventional Fluoroscopy

06

What researchers measure

Primary outcomes

  1. modified Harris Hip Score

    Patient-reported outcome measure. Scale 0-100, 100 indicating optimal function outcome

    Time frame: 1 year

  2. Nonarthritic Hip Score

    Patient-reported outcome measure. Scale 0-100, 100 indicating optimal function outcome

    Time frame: 1 year

  3. International Hip Outcome Tool-12

    Patient-reported outcome measure. Scale 0-100, 100 indicating optimal function outcome

    Time frame: 1 year

  4. Short Form 12 Mental

    Patient-reported outcome measure. Scale 0-100, 100 indicating optimal mental outcome

    Time frame: 1 year

  5. Short Form 12 Physical

    Patient-reported outcome measure. Scale 0-100, 100 indicating optimal function outcome

    Time frame: 1 year

  6. Veterans RAND 12-Item Health Survey Mental

    Patient-reported outcome measure. Scale 0-100, 100 indicating optimal mental outcome

    Time frame: 1 year

  7. Veterans RAND 12-Item Health Survey Physical

    Patient-reported outcome measure. Scale 0-100, 100 indicating optimal function outcome

    Time frame: 1 year

  8. Patient satisfaction

    Patient-reported outcome measure. Scale 0-10, 10 indicating patient is extremely satisfied with surgery and met expectations.

    Time frame: 1 year

  9. Visual Analog Pain Scale

    Patient-reported outcome measure. Scale 0-10, with 0 indicated no pain post-surgery.

    Time frame: 1 year

Secondary outcomes

  1. Age

    Demographic information

    Time frame: before surgery

  2. Body Mass Index, kg/m^2

    Demographic information

    Time frame: before surgery

07

Study locations

1 site
  • American Hip Institute
    Des Plaines, Illinois 60018, United States
08

References and documents

Publications

  • Larson CM, Giveans MR, Samuelson KM, Stone RM, Bedi A. Arthroscopic Hip Revision Surgery for Residual Femoroacetabular Impingement (FAI): Surgical Outcomes Compared With a Matched Cohort After Primary Arthroscopic FAI Correction. Am J Sports Med. 2014 Aug;42(8):1785-90. doi: 10.1177/0363546514534181. Epub 2014 May 29. PubMed 24875469 ↗
  • Mansor Y, Perets I, Close MR, Mu BH, Domb BG. In Search of the Spherical Femoroplasty: Cam Overresection Leads to Inferior Functional Scores Before and After Revision Hip Arthroscopic Surgery. Am J Sports Med. 2018 Jul;46(9):2061-2071. doi: 10.1177/0363546518779064. Epub 2018 Jun 20. PubMed 29924630 ↗
  • Matsuda DK, Schnieder CP, Sehgal B. The critical corner of cam femoroacetabular impingement: clinical support of an emerging concept. Arthroscopy. 2014 May;30(5):575-80. doi: 10.1016/j.arthro.2014.01.009. Epub 2014 Mar 12. PubMed 24630123 ↗
  • Ross JR, Larson CM, Adeoye O, Kelly BT, Bedi A. Residual deformity is the most common reason for revision hip arthroscopy: a three-dimensional CT study. Clin Orthop Relat Res. 2015 Apr;473(4):1388-95. doi: 10.1007/s11999-014-4069-9. Erratum In: Clin Orthop Relat Res. 2015 Mar;473(3):1167. Adeoyo, Olusanjo [corrected to Adeoye, Olusanjo]. PubMed 25475714 ↗

Individual participant data

Plan to share: No

09

Updates

Tracking since Sep 25, 2026
No changes since tracking began. The registry record was last updated on Aug 1, 2024, before this site started recording changes on Sep 25, 2026. Its history is on ClinicalTrials.gov ↗
10

Registry details

Key details

Study ID
NCT04265222
Lead sponsor
American Hip Institute
Collaborators
Stryker Orthopaedics
Responsible party
Sponsor
First posted
Feb 11, 2020
Start date
Mar 1, 2020
Primary completion
Dec 2024 (estimated)
Completion
Dec 2024 (estimated)
Last update
Aug 1, 2024

Study contacts

Ajay C Lall, MD, MS
principal investigator · American Hip Institute

Oversight

Data monitoring committee
No
FDA-regulated drug
No
FDA-regulated device
Yes
View the source record on ClinicalTrials.gov ↗

Not currently enrolling

This study is active, not recruiting, as verified in Jul 2024. You cannot join it, but the record below documents what was studied.

Follow this study

Get an email when the registry record changes — status, dates, results — or when someone posts here.

Sign in to follow

Discussion

Questions and observations about this study, from anyone following it. Not medical advice, and not a channel to the study team — their contact details are on the registry record.

Sign in to join the discussion. Reading takes no account; posting does. You choose a display name, and a pseudonym is the default.

Nothing here yet. If you are running this trial, taking part in it, or weighing whether to, this is the place to say so.

Start the discussion