An interventional study of WFMA - wireless floating microelectrode array in Ocular Injury, Optic Nerve Diseases and Photoreceptor Degeneration, sponsored by Illinois Institute of Technology. Recruiting at 1 site in United States. Open to participants aged 19 Years to 70 Years. Per ClinicalTrials.gov, last updated 2026-06-03.
Sponsored by Illinois Institute of Technology · Not applicable, Interventional, and Device feasibility
The purpose of this study is to determine the feasibility of producing artificial vision in persons with blindness. Study participants will have wireless electrical stimulators implanted into the cortical vision processing areas of their brains. The ability of the participants to perceive artificial vision in response to electrical stimulation will be assessed.
The objective of this study is to test the safety of the ICVP system and the feasibility of eliciting visual percepts in response to electrical stimulation in persons with blindness. The electrical stimulation is provided by wireless floating microelectrode arrays (WFMAs) that are part of the ICVP system. The WFMAs are implanted in the visual cortex. Five participants will take part in the study and each participant will have multiple WFMA devices implanted in their visual cortex on one side of the brain. After recovery from surgery, participants will begin a series of tests to assess the ability of electrical stimulation to induce visual percepts and how these percepts may provide some measure of artificial vision. Weekly participant testing will occur over a period of one to three years.
26 studies on the registry are indexed under Eye Injuries; 2 are open to participants now.
This study's planned enrollment of 5 is below the median of 42 across 11 interventional studies indexed under Eye Injuries.
Browse Eye Injuries studies →Illinois Institute of Technology is the lead sponsor of 10 studies on the registry; 3 are open to participants now.
Counted across the registry records on this site, refreshed daily.
Go through the criteria one by one — yes, no or not sure — and take the list to your doctor or the study team. Kept in this browser only.
Exclusion Criteria:
The WFMA is an electronic device that is implanted in the cortical vision processing regions of the brain to produce artificial vision.
Device: WFMA - wireless floating microelectrode array
Wirelessly transmitted patterns of electrical stimulation will be delivered to the visual cortex of study participants to generate visual percepts.
Also known as: ICVP System, ICVP, Intracortical Visual Prosthesis
To test the safety of the WFMA-based cortical interface.
Safety is defined as the number of adverse events occurring over the study period due to surgical complications or use of the WFMA device.
Time frame: From two-weeks post-op to end of device use, up to 3 years.
To test the efficacy of the WFMA-based cortical interface
Efficacy is defined as establishing a chronic intracortical interface for which the ability to elicit visual percepts in response to electrical stimulation can be demonstrated with stimulus intensities of 16 nanocoulombs per phase or less.
Time frame: From four-weeks post-op to end of device use, up to 3 years.
Plan to share: Yes — We may electively share de-identified study data with collaborators
Supporting information: Study protocol, Statistical analysis plan, Informed consent form
Time frame: Duration of the study
Access criteria: Data required by study collaborators to perform analysis of safety and efficacy of the ICVP system.
Eligibility is decided by the study team. Share this record with your doctor or contact the team directly.
Contact study teamGet an email when the registry record changes — status, dates, results — or when someone posts here.
Sign in to followQuestions and observations about this study, from anyone following it. Not medical advice, and not a channel to the study team — their contact details are on the registry record.
Sign in to join the discussion. Reading takes no account; posting does. You choose a display name, and a pseudonym is the default.
Nothing here yet. If you are running this trial, taking part in it, or weighing whether to, this is the place to say so.
Illinois Institute of Technology