An observational study in Aortic Valve Stenosis, sponsored by Shanghai MicroPort CardioFlow Medtech Co., Ltd.. Recruiting at 2 sites in China. Open to participants aged 70 Years and older. Per ClinicalTrials.gov, last updated 2020-06-04.
Sponsored by Shanghai MicroPort CardioFlow Medtech Co., Ltd. (part of MicroPort Scientific Corporation) · Observational
Help build ClinicalTrials.gg — short surveys, remote interviews or testing, in your language. Take part →
Among 69 studies in Aortic Valve Stenosis with a site in China — 43 open to participants now, 51 under way, 3 of them phase 3. Aortic Valve Stenosis · China.
Among the 69 studies in Aortic Valve Stenosis with a site in China, this one is the 17th largest by planned enrollment of the 22 observational ones that give a count, is one of 6 that started in 2020, is one of 22 observational ones, reaches primary completion later than 4 of the 50 other live ones, and was the 14th registered.
1,028 studies on the registry are indexed under Aortic Valve Stenosis; 295 are open to participants now.
Browse Aortic Valve Stenosis studies →43 of the 69 studies in Aortic Valve Stenosis with a site in China are open now. Recruiting first, the newest first:
West China Hospital · Sites in China
Ages 35–80
Yan'an Affiliated Hospital of Kunming Medical University · Sites in China
Ages 18+
Beijing Balance Medical Technology Co., Ltd · Sites in China
Ages 60–100
Anhui Provincial Cancer Hospital · Sites in China
Ages 18–80 · Healthy volunteers
RenJi Hospital · Sites in China
Ages 18+
A study can be open while its sites in China have not opened yet or have stopped. Only those recruiting at a site in China →
Of the 209 Aortic Valve Stenosis studies recruiting now, 163 (78%) set no upper age limit and 9 (4%) stop at 75 or younger; 24 take children under 18; 14 take healthy volunteers.
This study: 70 Years and older · all sexes · no healthy volunteers.
The full table on the hub →This tab as a report to print or save as PDF → With an account.
69 studies; the count open now beside each. This study's row is marked.
First in 2012; this study’s year is marked. 6 started in 2020.
By drug class, each counting the studies that test any of its medicines:
This study's planned enrollment of 100 is below the median of 200 across 437 observational studies indexed under Aortic Valve Stenosis.
Median enrollment 120 across the 47 interventional studies, 490 across the 22 observational. Of the 7 that completed or were terminated, 2 (29%) have results posted.
This tab as a report to print or save as PDF → With an account.
27 of 69 have an industry lead sponsor. The 10 most frequent:
This study is registered under Shanghai MicroPort CardioFlow Medtech Co., Ltd., one of the names counted as MicroPort Scientific Corporation. Under that name alone:
Shanghai MicroPort CardioFlow Medtech Co., Ltd. is the lead sponsor of 9 studies on the registry; 6 are open to participants now.
MicroPort Scientific Corporation has 9 studies filed under Aortic Valve Stenosis — fewer than ten, so there is no comparison to draw.
5 of the studies in Aortic Valve Stenosis with a site in China that are under way reach primary completion within a year, 0 of them phase 3. Phase 3 first, then by date:
| Study | Primary completion |
|---|---|
| NCT07335900RenJi HospitalA Clinical Study Using FAPI-PET Imaging to Assess the Postoperative Effects of TAVI in Patients With Aortic Stenosis | 2026-12-30 |
| NCT07390513Chinese Academy of Medical Sciences, Fuwai HospitalElectrophysiological Outcomes After Transcatheter Aortic Valve Replacement | 2026-12-31 |
| NCT06891079Xijing HospitalVideodensitometric Angiographic Assessment of AR in the Cath-lab for Intraprocedural Guidance of TAVI in CHINA | 2026-12-31 |
| NCT07035847Chinese Academy of Medical Sciences, Fuwai HospitalTransaxillary TAVR With Solely Echocardiography Guidance | 2026-12-31 |
| NCT07414342Beijing Balance Medical Technology Co., LtdSafety and Efficacy of the RENATUS® Transcatheter Aortic Valve System for the Treatment of Severe Aortic Stenosis | 2027-09 |
Add all 5 to your calendar (.ics) → With an account.
Among the 69 studies in Aortic Valve Stenosis with a site in China, from their registry updates:
This tab as a report to print or save as PDF → With an account.
The study objective is to evaluate safety and effectiveness/performance of the Microport™ CardioFlow VitaFlow™ Transcatheter Aortic Valve System for the treatment of severe aortic stenosis in the real world settings.
This is a prospective, single-arm, multi-center, observational, post-market registry study. The purpose is to evaluate the safety, performance, and effectiveness of the VitaFlow™ Transcatheter Aortic Valve System in the real world settings.Patients will be seen at pre and post procedure, discharge, 30 days, 1 year and annually up to 5 years.
The study population includes symptomatic patients (≥70 years old ) with calcified, severe, degenerative, native aortic valve stenosis who are not suitable for the surgical aortic valve replacement as assessed by the heart team
Go through the criteria one by one — yes, no or not sure — and take the list to your doctor or the study team. Kept in this browser only.
Exclusion Criteria:
Underlined terms in the criteria open these too. Explained by clinicaltrials.gg, not part of the registry record. The study team decides who can take part.
Before you join, the study team explains what taking part involves — its purpose, what happens, the risks and possible benefits — and answers your questions, so you can decide freely. Consent is usually recorded on a form (the informed consent form, ICF) signed by you or, where the law allows, by someone legally authorized to decide for you.
You can keep asking questions during the study, you are told of new information that matters, and you can choose to leave at any time.
An allergy, or another reaction of the immune system, to a substance. “Hypersensitivity to the study drug” means a known allergic reaction to it — not every side effect a medicine can have.
A reason a treatment, test or procedure should not be given to a particular person, such as an allergy, another illness or a medicine they take.
The study doctor’s estimate of how long someone is likely to live. Criteria use it so that people can stay in the study long enough for it to answer its question.
Informed consent
Before you join, the study team explains what taking part involves — its purpose, what happens, the risks and possible benefits — and answers your questions, so you can decide freely. Consent is usually recorded on a form (the informed consent form, ICF) signed by you or, where the law allows, by someone legally authorized to decide for you.
You can keep asking questions during the study, you are told of new information that matters, and you can choose to leave at any time.
Explained by clinicaltrials.gg, not part of the registry record. The study team decides who can take part.
Hypersensitivity
An allergy, or another reaction of the immune system, to a substance. “Hypersensitivity to the study drug” means a known allergic reaction to it — not every side effect a medicine can have.
Explained by clinicaltrials.gg, not part of the registry record. The study team decides who can take part.
Contraindication
A reason a treatment, test or procedure should not be given to a particular person, such as an allergy, another illness or a medicine they take.
Explained by clinicaltrials.gg, not part of the registry record. The study team decides who can take part.
Life expectancy
The study doctor’s estimate of how long someone is likely to live. Criteria use it so that people can stay in the study long enough for it to answer its question.
Explained by clinicaltrials.gg, not part of the registry record. The study team decides who can take part.
Subjects in the treatment group will be implanted with the VitaFlow™ Transcatheter Aortic Valve System
Device: VitaFlow™ Transcatheter Aortic Valve System
VitaFlow™ Transcatheter Aortic Valve System contains a valve stent-VitaFlow™ Aortic Valve, a delivery system-VitaFlow™ Delivery System,loading tools, a balloon dilatation catheter, and an introducer set
Rate of all-cause mortality at 12 months post implantation
Rate of all-cause mortality including cardiovascular and non-cardiovascular death
Time frame: 12 months post implantation
Valve function-mean transvalvular gradient
Mean transvalvular gradient measured by transthoracic echocardiography (TTE)(in mmHg)
Time frame: at discharge, 30 days, 1 year and annually up to 5 years post implantation
Valve function-effective orifice area
Effective orifice area measured by transthoracic echocardiography (TTE)(in cm\^2)
Time frame: at discharge, 30 days, 1 year and annually up to 5 years post implantation
Valve function-degree of prosthetic valve regurgitation
Degree of prosthetic valve regurgitation, including paravalvular leak and intravalvular regurgitation measured by transthoracic echocardiography (TTE)
Time frame: at discharge, 30 days, 1 year and annually up to 5 years post implantation
Rate of safety events according to VARC2
Rate of safety events according to VARC2 including all-cause mortality, myocardial infarction, stroke, bleeding, acute kidney injury, vascular complications, new permanent pacemaker implantation
Time frame: at immediate, 30 days, 1 year and annually up to 5 years post implantation
Rate of other TAVI-related complications
Rate of other TAVI-related complications including conversion to open surgery, unplanned use of cardiopulmonary bypass, coronary obstruction, ventricular septal perforation, mitral valve apparatus damage or dysfunction, cardiac tamponade, endocarditis, valve thrombosis, valve mal-positioning, TAV-in-TAV, valve related dysfunction requiring repeat procedure (TAVI,SAVR,BAV)
Time frame: at immediate, 30 days, 1 year and annually up to 5 years post implantation
Rate of device success
Rate of device success, assessed by the access, delivery, deployment and implantation of the device and the prosthetic valve function
Time frame: at immediate post implantation
Rate of balloon pre-dilatation success
Rate of balloon pre-dilatation success, assessed by the access, delivery, pre-dilatation and retrieval of the balloon catheter
Time frame: at immediate post implantation
Rate of balloon post-dilatation success
Rate of balloon pre-dilatation success, assessed by the access, delivery, post-dilatation and retrieval of the balloon catheter
Time frame: at immediate post implantation
Rate of procedure success
Rate of procedure success, assessed by the device success and peri-procedural complications
Time frame: at immediate post implantation
Started Apr 2020 (actual). Primary completion is estimated for Dec 2021, 19 months after the start.
Of 37 industry-sponsored observational studies under Aortic Valve Stenosis, half reached primary completion within 34 months of starting (the median), counting those still running; a quarter within 21 and three quarters within 47. This study's planned 19 months is below that.
Counting every sponsor, half of 243 studies reached it within 44 months; a quarter within 23 and three quarters within 86.
How these figures are worked out, and which studies are left out of them.
Eligibility is decided by the study team. Share this record with your doctor or contact the team directly.
Contact study teamGet an email when the registry record changes — status, dates, results — or when someone posts here.
Sign in to followQuestions and observations about this study, from anyone following it. Not medical advice, and not a channel to the study team — their contact details are on the registry record.
Sign in to join the discussion. Reading takes no account; posting does. You choose a display name, and a pseudonym is the default.
Nothing here yet. If you are running this trial, taking part in it, or weighing whether to, this is the place to say so.
Shanghai MicroPort CardioFlow Medtech Co., Ltd. →