An interventional study of Percutaneous Coronary Intervention in Coronary Artery Disease, Coronary Artery Stenosis and Coronary Disease, sponsored by Elixir Medical Corporation. Active, not recruiting at 36 sites in 4 countries. Open to participants aged 20 Years and older. Per ClinicalTrials.gov, last updated 2025-03-24.
Sponsored by Elixir Medical Corporation · Not applicable, Interventional, and Treatment
Help build ClinicalTrials.gg — short surveys, remote interviews or testing, in your language. Take part →
Among 16 studies in Coronary Artery Disease by Elixir Medical Corporation — 1 open to participants now, 4 under way, none of them phase 3. Coronary Artery Disease · Elixir Medical Corporation.
Among the 16 studies in Coronary Artery Disease by Elixir Medical Corporation, this one is the 2nd largest by enrollment of the 15 interventional ones that give a count, is one of 4 that started in 2020, is one of 13 with no phase, and was the 9th registered.
4,866 studies on the registry are indexed under Coronary Artery Disease; 892 are open to participants now.
Browse Coronary Artery Disease studies →1 of the 16 studies in Coronary Artery Disease by Elixir Medical Corporation is open now, in 9 countries. Recruiting first, the newest first:
Elixir Medical Corporation · Sites in Austria, Curacao, Indonesia and 6 more countries
Ages 18+
By country, each count listing its studies:
Of the 591 Coronary Artery Disease studies recruiting now, 404 (68%) set no upper age limit and 68 (12%) stop at 75 or younger; 37 take children under 18; 49 take healthy volunteers.
This study: 20 Years and older · all sexes · no healthy volunteers.
The full table on the hub →This tab as a report to print or save as PDF → With an account.
16 studies; the count open now beside each. This study's row is marked.
First in 2008; this study’s year is marked. 4 started in 2020.
This study's enrollment of 445 is above the median of 123 across 3,011 interventional studies indexed under Coronary Artery Disease.
Median enrollment 57 across the 15 interventional studies, 5,000 across the 1 observational. Of the 12 that completed or were terminated, 3 (25%) have results posted.
This tab as a report to print or save as PDF → With an account.
Elixir Medical Corporation is the lead sponsor of 18 studies on the registry; 1 is open to participants now.
None of the studies under way reaches primary completion within a year.
Among the 16 studies in Coronary Artery Disease by Elixir Medical Corporation, from their registry updates:
Nothing recorded among them since 2026-09-25.
This tab as a report to print or save as PDF → With an account.
The objective of this study is to verify the safety and efficacy of the investigational device (ELX1805J) for the treatment of ischemic heart disease due to de novo, native coronary artery lesions
The Bioadaptor RCT Study is a prospective, 1:1 randomized study of parallel designed, that will enroll up to 444 patients requiring treatment of up to two de novo coronary lesions of ≤ 34 mm in length in vessels of ≥ 2.25 mm and ≤ 4.0 mm in diameter.
One or two designated target lesions, located in separate epicardial vessels (RCA, LCX or LAD), and meeting the inclusion/exclusion criteria may be treated with the ELX1805J (DynamX Bioadaptor) or Resolute Onyx stent
The primary safety endpoint is Target Lesion Failure (TLF) at 12 months. TLF is a composite endpoint defined as cardiac death, target vessel MI, and clinically-indicated target lesion revascularization
Additional secondary safety and effectiveness endpoints will be evaluated at 30 days, 6 and 12 months and 2-5 years.
Using visual assessment, the target lesion must measure ≥ 2.25 mm and ≤ 4.0 mm in diameter and ≤ 34 mm in length able to be covered by a single ELX1805J or Resolute Onyx stent including 2 mm of healthy vessel on either side of the planned treatment area.
The patient will be eligible for device implantation only after satisfactory lesion pre-dilatation defined as: ≥ TIMI 2 flow, and no dissection greater than Grade B (NHLBI) able to be covered with a single device
Go through the criteria one by one — yes, no or not sure — and take the list to your doctor or the study team. Kept in this browser only.
General Inclusion Criteria
Patients who meet all of the following criteria are eligible:
Percutaneous intervention of lesions in a non-target vessel if:
Percutaneous intervention of lesions located in the target vessel if:
Exclusion Criteria:
Patients with a target lesion involving a bifurcation of which the side branch will be jailed by the struts and:
Underlined terms in the criteria open these too. Explained by clinicaltrials.gg, not part of the registry record. The study team decides who can take part.
A recording of the heart’s electrical activity, taken with stickers on the chest, arms and legs. It takes a few minutes and does not hurt.
Blood cells that help blood clot. Too few raises the risk of bleeding and bruising. A usual adult range is about 150–400 × 10⁹/L (150,000–400,000 per µL); each lab has its own reference range.
Before you join, the study team explains what taking part involves — its purpose, what happens, the risks and possible benefits — and answers your questions, so you can decide freely. Consent is usually recorded on a form (the informed consent form, ICF) signed by you or, where the law allows, by someone legally authorized to decide for you.
You can keep asking questions during the study, you are told of new information that matters, and you can choose to leave at any time.
Able to become pregnant: from the first period until menopause, unless permanently unable to through surgery (removal of the womb, or of both ovaries or both fallopian tubes).
Criteria for people of childbearing potential usually ask for a negative pregnancy test and for contraception during the study and for a time after it.
The top of the normal range for a blood test, as set by the laboratory that runs it. Each lab prints its own range next to your result.
“≤ 2.5 × ULN” means the result can be up to two and a half times that top value.
An allergy, or another reaction of the immune system, to a substance. “Hypersensitivity to the study drug” means a known allergic reaction to it — not every side effect a medicine can have.
A reason a treatment, test or procedure should not be given to a particular person, such as an allergy, another illness or a medicine they take.
The share of blood the heart’s main pumping chamber (the left ventricle) pushes out with each beat, measured by an echocardiogram (heart ultrasound) or a MUGA scan. About 50–70% is normal.
Malignancy means cancer. Criteria about another or earlier malignancy ask whether you have had a different cancer, usually within a set number of years.
Some are commonly allowed, such as treated skin cancers other than melanoma and early cancers removed completely — check the exceptions this study lists.
A weakened immune system. It can come from an illness, such as HIV or some blood cancers, or from medicines that turn the immune system down, for example after an organ transplant or for an autoimmune disease; steroids at higher doses count.
Read whether the line is about a condition or about medicines, and which medicines and doses it means.
Anti-inflammatory medicines such as prednisone, prednisolone and dexamethasone — not the anabolic steroids used for muscle.
Studies differ in what they allow: check which steroid medicines, routes (tablets, injections, creams, inhalers, eye drops) and doses this study accepts.
A condition in which the immune system attacks the body’s own tissues, such as rheumatoid arthritis, lupus, psoriasis, type 1 diabetes or inflammatory bowel disease.
Immunotherapy studies often leave out active autoimmune disease, and some name exceptions, such as thyroid disease on replacement hormone. Check the exceptions this study lists.
The human immunodeficiency virus, which weakens the immune system.
Many studies now accept people whose HIV is controlled on treatment, judged by the viral load and the CD4 count. Check the limits this study sets.
A score of how well the liver works in people with liver disease such as cirrhosis: class A is mild, B moderate and C severe.
A “mini-stroke”: temporary stroke-like symptoms caused by reduced blood flow to part of the brain, spinal cord or eye, without signs of a new stroke on a scan.
Stroke symptoms need emergency care at once, even if they go away.
The New York Heart Association’s four classes of how much heart failure limits physical activity.
Studies set their own limit — many outside heart failure leave out class III–IV, while heart failure studies may ask for a particular class. Check the class this study names.
The study doctor’s estimate of how long someone is likely to live. Criteria use it so that people can stay in the study long enough for it to answer its question.
ECG (electrocardiogram)
A recording of the heart’s electrical activity, taken with stickers on the chest, arms and legs. It takes a few minutes and does not hurt.
Explained by clinicaltrials.gg, not part of the registry record. The study team decides who can take part.
Platelets
Blood cells that help blood clot. Too few raises the risk of bleeding and bruising. A usual adult range is about 150–400 × 10⁹/L (150,000–400,000 per µL); each lab has its own reference range.
Explained by clinicaltrials.gg, not part of the registry record. The study team decides who can take part.
Informed consent
Before you join, the study team explains what taking part involves — its purpose, what happens, the risks and possible benefits — and answers your questions, so you can decide freely. Consent is usually recorded on a form (the informed consent form, ICF) signed by you or, where the law allows, by someone legally authorized to decide for you.
You can keep asking questions during the study, you are told of new information that matters, and you can choose to leave at any time.
Explained by clinicaltrials.gg, not part of the registry record. The study team decides who can take part.
Childbearing potential
Able to become pregnant: from the first period until menopause, unless permanently unable to through surgery (removal of the womb, or of both ovaries or both fallopian tubes).
Criteria for people of childbearing potential usually ask for a negative pregnancy test and for contraception during the study and for a time after it.
Explained by clinicaltrials.gg, not part of the registry record. The study team decides who can take part.
ULN (upper limit of normal)
The top of the normal range for a blood test, as set by the laboratory that runs it. Each lab prints its own range next to your result.
“≤ 2.5 × ULN” means the result can be up to two and a half times that top value.
Explained by clinicaltrials.gg, not part of the registry record. The study team decides who can take part.
Hypersensitivity
An allergy, or another reaction of the immune system, to a substance. “Hypersensitivity to the study drug” means a known allergic reaction to it — not every side effect a medicine can have.
Explained by clinicaltrials.gg, not part of the registry record. The study team decides who can take part.
Contraindication
A reason a treatment, test or procedure should not be given to a particular person, such as an allergy, another illness or a medicine they take.
Explained by clinicaltrials.gg, not part of the registry record. The study team decides who can take part.
LVEF (left ventricular ejection fraction)
The share of blood the heart’s main pumping chamber (the left ventricle) pushes out with each beat, measured by an echocardiogram (heart ultrasound) or a MUGA scan. About 50–70% is normal.
Explained by clinicaltrials.gg, not part of the registry record. The study team decides who can take part.
Cancer (malignancy)
Malignancy means cancer. Criteria about another or earlier malignancy ask whether you have had a different cancer, usually within a set number of years.
Some are commonly allowed, such as treated skin cancers other than melanoma and early cancers removed completely — check the exceptions this study lists.
Explained by clinicaltrials.gg, not part of the registry record. The study team decides who can take part.
Immunosuppression
A weakened immune system. It can come from an illness, such as HIV or some blood cancers, or from medicines that turn the immune system down, for example after an organ transplant or for an autoimmune disease; steroids at higher doses count.
Read whether the line is about a condition or about medicines, and which medicines and doses it means.
Explained by clinicaltrials.gg, not part of the registry record. The study team decides who can take part.
Corticosteroids (steroids)
Anti-inflammatory medicines such as prednisone, prednisolone and dexamethasone — not the anabolic steroids used for muscle.
Studies differ in what they allow: check which steroid medicines, routes (tablets, injections, creams, inhalers, eye drops) and doses this study accepts.
Explained by clinicaltrials.gg, not part of the registry record. The study team decides who can take part.
Autoimmune disease
A condition in which the immune system attacks the body’s own tissues, such as rheumatoid arthritis, lupus, psoriasis, type 1 diabetes or inflammatory bowel disease.
Immunotherapy studies often leave out active autoimmune disease, and some name exceptions, such as thyroid disease on replacement hormone. Check the exceptions this study lists.
Explained by clinicaltrials.gg, not part of the registry record. The study team decides who can take part.
HIV
The human immunodeficiency virus, which weakens the immune system.
Many studies now accept people whose HIV is controlled on treatment, judged by the viral load and the CD4 count. Check the limits this study sets.
Explained by clinicaltrials.gg, not part of the registry record. The study team decides who can take part.
Child-Pugh class
A score of how well the liver works in people with liver disease such as cirrhosis: class A is mild, B moderate and C severe.
Explained by clinicaltrials.gg, not part of the registry record. The study team decides who can take part.
TIA (transient ischaemic attack)
A “mini-stroke”: temporary stroke-like symptoms caused by reduced blood flow to part of the brain, spinal cord or eye, without signs of a new stroke on a scan.
Stroke symptoms need emergency care at once, even if they go away.
Explained by clinicaltrials.gg, not part of the registry record. The study team decides who can take part.
NYHA class (heart failure)
The New York Heart Association’s four classes of how much heart failure limits physical activity.
Studies set their own limit — many outside heart failure leave out class III–IV, while heart failure studies may ask for a particular class. Check the class this study names.
Explained by clinicaltrials.gg, not part of the registry record. The study team decides who can take part.
Life expectancy
The study doctor’s estimate of how long someone is likely to live. Criteria use it so that people can stay in the study long enough for it to answer its question.
Explained by clinicaltrials.gg, not part of the registry record. The study team decides who can take part.
The Elixir Bioadaptor (ELX1805J) 2.25 - 4.0 mm diameter and 14,15,18, 23, 28, 32 and 38 mm in length
Device: Percutaneous Coronary Intervention
The Medtronic Resolute Onyx Stent 2.25 - 4.0 mm diameter and 15, 18, 22, 30, 34 and 38 mm in length
Device: Percutaneous Coronary Intervention
Percutaneous coronary intervention of de novo native coronary artery lesions
Percentage of Participants With Target Lesion Failure (TLF)
The primary endpoint of the BIOADAPTOR RCT is Target Lesion Failure (TLF), which is a composite endpoint defined as cardiac death, target-vessel MI, and Clinically-Indicated TLR
Time frame: 12 Months
Percentage of Participants With Target Lesion Failure (TLF)
TLF is a composite endpoint defined as cardiovascular death, target-vessel MI, and Clinically-Indicated TLR
Time frame: Through 12 months post-procedure
Percentage of Participants With Patient Oriented Clinical Endpoint
Overall cardiovascular outcomes from the patient's perspective. This endpoint is a composite endpoint that includes all-cause mortality (cardiac and non-cardiac), stroke, MI (target vessel and non-target vessel) and revascularization (target vessel and non-target vessel)
Time frame: Through 12 months
Percentage of Participants With Composite of All-cause Mortality
A composite of all-cause mortality, MI (target vessel or non-target vessel) and revascularization (target vessel or non-target vessel)
Time frame: Through 12 months post-procedure
Percentage of Participants With Composite of Cardiovascular Death, TVMI and ID-TVR Revascularization
Composite of cardiac death, target vessel myocardial infarction (TV-MI), or ischemia-driven target vessel revascularization (ID-TVR)
Time frame: Through 12 months
Percentage of Participants With Cardiovascular Death, Stroke, MI and Revascularization
Composite of cardiovascular death, stroke, MI (target vessel and non-target vessel) and revascularization (target vessel and non-target vessel)
Time frame: Through 12 months
Percentage of Participants With Cardiovascular Death, MI and Revascularization
Composite of cardiovascular death, MI (target vessel or non-target vessel) and revascularization (target vessel or non-target vessel)
Time frame: Through 12 months
Percentage of Participants With Clinically Indicated Target Lesion Revascularization (CI-TLR)
Number of Patients with Clinically Indicated Target Lesion Revascularization (CI-TLR)
Time frame: Through 12 months post-procedure
Percentage of Participants With Target Lesion Revascularization (TLR)
Target lesion revascularization
Time frame: Through 12 months post-procedure
Percentage of Participants With Target Vessel Revascularization (TVR)
Re-PCI or CABG of the target vessel due to in-segment restenosis or other complications
Time frame: Through 12 months post-procedure
Percentage of Participants With Clinically Indicated TVR (CI-TVR)
Re-PCI or CABG in the target vessel due to restenosis or other complications
Time frame: Through 12 months post-procedure
Percentage of Participants With Revascularization (Target Vessel or Non-target Vessel)
Revascularization of the target vessel or non-target vessel due to in-segment restenosis or other complications
Time frame: Through 12 months post procedure
Percentage of Participants With Q-wave MI
CK post procedure is twice the upper limit of the reference value or higher, with new pathological Q-wave on 2 or more contiguous ECG leads and if CK-MB is measured, CK-MB is positive, if no CKMB then troponin is positive.
Time frame: Through 12 months post-procedure
Percentage of Participants With Non Q-wave MI
CK post procedure is twice the upper limit of the reference value or higher, without new pathological Q-waves. If CK-MB is measured, CK-MB is positive, if no CKMB then troponin is positive.
Time frame: Through 12 months post-procedure
Percentage of Participants With MI (Target Vessel or Non-target Vessel)
MI is defined as per the Academic Research Consortium (ARC-2) criteria
Time frame: Through 12 months post procedure
Percentage of Participants With Target Vessel MI
MI is defined as per the Academic Research Consortium (ARC-2) criteria
Time frame: Through 12 months post procedure
Percentage of Participants With All-cause Mortality
As defined per the Academic Research Consortium (ARC-2) criteria
Time frame: Through 12 months post-procedure
Percentage of Participants With Cardiovascular Death
As defined as per the Academic Research Consortium (ARC-2) criteria
Time frame: Through 12 months post procedure
Percentage of Participants With Composite of Cardiovascular Death or Target Vessel MI
Target Vessel Related Death or MI
Time frame: Through 12 months post procedure
Percentage of Participants With Composite of All-cause Death or MI
Target vessel or non-target vessel related death or MI
Time frame: Through 12 months post-procedure
Percentage of Participants With Composite of All-cause Death, MI (Target Vessel or Non-target Vessel), or TVR
Any Death, any MI and any Target Vessel Revascularization
Time frame: Through 12 months post-procedure
Percentage of Participants With Composite of Probable or Definite Stent Thrombosis
Defined as per the Academic Research Consortium (ARC-2) criteria
Time frame: Through 12 months post-procedure
Percentage of Participants With Probable Stent Thrombosis
Defined as per the Academic Research Consortium (ARC-2) criteria
Time frame: Through 12 months post-procedure
Percentage of Participants With Definite Stent Thrombosis
Defined as per the Academic Research Consortium (ARC-2) criteria
Time frame: Through 12 months
Study recruitment and enrollment took place at 34 global centers including 14 in Japan and 20 in Europe between December 2020 to February 2022. A total of 445 patients with de novo coronary artery lesions were enrolled and randomly assigned to either the DynamX arm or the Resolute Onyx arm.
| Milestone | Elixir Bioadaptor (ELX1805J) | Medtronic Resolute Onyx Stent |
|---|---|---|
| Started | 223 | 222 |
| Completed | 221 | 215 |
| Not completed | 2 | 7 |
The primary endpoint of the BIOADAPTOR RCT is Target Lesion Failure (TLF), which is a composite endpoint defined as cardiac death, target-vessel MI, and Clinically-Indicated TLR
| percentage of participants | Elixir Bioadaptor (ELX1805J) | Medtronic Resolute Onyx Stent |
|---|---|---|
| Percentage of Participants With Target Lesion Failure (TLF) | 1.81 (.50 to 4.57) | 2.79 (1.03 to 5.97) |
TLF is a composite endpoint defined as cardiovascular death, target-vessel MI, and Clinically-Indicated TLR
| percentage of participants | Elixir Bioadaptor (ELX1805J) | Medtronic Resolute Onyx Stent |
|---|---|---|
| Percentage of Participants With Target Lesion Failure (TLF) | 1.8 (0.5 to 4.6) | 2.8 (1.0 to 6.0) |
Overall cardiovascular outcomes from the patient's perspective. This endpoint is a composite endpoint that includes all-cause mortality (cardiac and non-cardiac), stroke, MI (target vessel and non-target vessel) and revascularization (target vessel and non-target vessel)
| percentage of participants | Elixir Bioadaptor (ELX1805J) | Medtronic Resolute Onyx Stent |
|---|---|---|
| Percentage of Participants With Patient Oriented Clinical Endpoint | 6.8 (3.8 to 10.9) | 7.9 (4.7 to 12.3) |
A composite of all-cause mortality, MI (target vessel or non-target vessel) and revascularization (target vessel or non-target vessel)
| percentage of participants | Elixir Bioadaptor (ELX1805J) | Medtronic Resolute Onyx Stent |
|---|---|---|
| Percentage of Participants With Composite of All-cause Mortality | 6.8 (3.8 to 10.9) | 7.9 (4.7 to 12.3) |
Composite of cardiac death, target vessel myocardial infarction (TV-MI), or ischemia-driven target vessel revascularization (ID-TVR)
| percentage of participants | Elixir Bioadaptor (ELX1805J) | Medtronic Resolute Onyx Stent |
|---|---|---|
| Percentage of Participants With Composite of Cardiovascular Death, TVMI and ID-TVR Revascularization | 1.8 (0.5 to 4.6) | 3.7 (1.6 to 7.2) |
Composite of cardiovascular death, stroke, MI (target vessel and non-target vessel) and revascularization (target vessel and non-target vessel)
| percentage of participants | Elixir Bioadaptor (ELX1805J) | Medtronic Resolute Onyx Stent |
|---|---|---|
| Percentage of Participants With Cardiovascular Death, Stroke, MI and Revascularization | 6.3 (3.5 to 10.4) | 7.4 (4.3 to 11.8) |
Composite of cardiovascular death, MI (target vessel or non-target vessel) and revascularization (target vessel or non-target vessel)
| percentage of participants | Elixir Bioadaptor (ELX1805J) | Medtronic Resolute Onyx Stent |
|---|---|---|
| Percentage of Participants With Cardiovascular Death, MI and Revascularization | 6.3 (3.5 to 10.4) | 7.4 (4.3 to 11.8) |
Number of Patients with Clinically Indicated Target Lesion Revascularization (CI-TLR)
| percentage of participants | Elixir Bioadaptor (ELX1805J) | Medtronic Resolute Onyx Stent |
|---|---|---|
| Percentage of Participants With Clinically Indicated Target Lesion Revascularization (CI-TLR) | 0.9 (0.1 to 3.2) | 0.5 (0.0 to 2.6) |
Target lesion revascularization
| percentage of participants | Elixir Bioadaptor (ELX1805J) | Medtronic Resolute Onyx Stent |
|---|---|---|
| Percentage of Participants With Target Lesion Revascularization (TLR) | 1.4 (0.3 to 3.9) | 0.9 (0.1 to 3.4) |
Re-PCI or CABG of the target vessel due to in-segment restenosis or other complications
| percentage of participants | Elixir Bioadaptor (ELX1805J) | Medtronic Resolute Onyx Stent |
|---|---|---|
| Percentage of Participants With Target Vessel Revascularization (TVR) | 1.4 (0.3 to 3.9) | 1.9 (0.5 to 4.7) |
Re-PCI or CABG in the target vessel due to restenosis or other complications
| percentage of participants | Elixir Bioadaptor (ELX1805J) | Medtronic Resolute Onyx Stent |
|---|---|---|
| Percentage of Participants With Clinically Indicated TVR (CI-TVR) | 0.9 (0.1 to 3.2) | 1.4 (0.3 to 4.1) |
Revascularization of the target vessel or non-target vessel due to in-segment restenosis or other complications
| percentage of participants | Elixir Bioadaptor (ELX1805J) | Medtronic Resolute Onyx Stent |
|---|---|---|
| Percentage of Participants With Revascularization (Target Vessel or Non-target Vessel) | 5.4 (2.8 to 9.3) | 5.2 (2.6 to 9.1) |
CK post procedure is twice the upper limit of the reference value or higher, with new pathological Q-wave on 2 or more contiguous ECG leads and if CK-MB is measured, CK-MB is positive, if no CKMB then troponin is positive.
| percentage of participants | Elixir Bioadaptor (ELX1805J) | Medtronic Resolute Onyx Stent |
|---|---|---|
| Percentage of Participants With Q-wave MI | 0.0 (0.0 to 1.7) | 0.9 (0.1 to 3.4) |
CK post procedure is twice the upper limit of the reference value or higher, without new pathological Q-waves. If CK-MB is measured, CK-MB is positive, if no CKMB then troponin is positive.
| percentage of participants | Elixir Bioadaptor (ELX1805J) | Medtronic Resolute Onyx Stent |
|---|---|---|
| Percentage of Participants With Non Q-wave MI | 0.9 (0.1 to 3.2) | 0.9 (0.1 to 3.4) |
MI is defined as per the Academic Research Consortium (ARC-2) criteria
| percentage of participants | Elixir Bioadaptor (ELX1805J) | Medtronic Resolute Onyx Stent |
|---|---|---|
| Percentage of Participants With MI (Target Vessel or Non-target Vessel) | 1.4 (0.3 to 3.9) | 1.9 (0.5 to 4.7) |
MI is defined as per the Academic Research Consortium (ARC-2) criteria
| percentage of participants | Elixir Bioadaptor (ELX1805J) | Medtronic Resolute Onyx Stent |
|---|---|---|
| Percentage of Participants With Target Vessel MI | 1.4 (0.3 to 3.9) | 1.9 (0.5 to 4.7) |
As defined per the Academic Research Consortium (ARC-2) criteria
| percentage of participants | Elixir Bioadaptor (ELX1805J) | Medtronic Resolute Onyx Stent |
|---|---|---|
| Percentage of Participants With All-cause Mortality | 0.5 (0.0 to 2.5) | 1.4 (0.3 to 4.0) |
As defined as per the Academic Research Consortium (ARC-2) criteria
| percentage of participants | Elixir Bioadaptor (ELX1805J) | Medtronic Resolute Onyx Stent |
|---|---|---|
| Percentage of Participants With Cardiovascular Death | 0.0 (0.0 to 1.7) | 0.9 (0.1 to 3.3) |
Target Vessel Related Death or MI
| percentage of participants | Elixir Bioadaptor (ELX1805J) | Medtronic Resolute Onyx Stent |
|---|---|---|
| Percentage of Participants With Composite of Cardiovascular Death or Target Vessel MI | 1.4 (0.3 to 3.9) | 2.8 (1.0 to 6.0) |
Target vessel or non-target vessel related death or MI
| percentage of participants | Elixir Bioadaptor (ELX1805J) | Medtronic Resolute Onyx Stent |
|---|---|---|
| Percentage of Participants With Composite of All-cause Death or MI | 1.8 (0.5 to 4.5) | 3.2 (1.3 to 6.6) |
Any Death, any MI and any Target Vessel Revascularization
| percentage of participants | Elixir Bioadaptor (ELX1805J) | Medtronic Resolute Onyx Stent |
|---|---|---|
| Percentage of Participants With Composite of All-cause Death, MI (Target Vessel or Non-target Vessel), or TVR | 2.7 (1.0 to 5.8) | 4.6 (2.2 to 8.3) |
Defined as per the Academic Research Consortium (ARC-2) criteria
| percentage of participants | Elixir Bioadaptor (ELX1805J) | Medtronic Resolute Onyx Stent |
|---|---|---|
| Percentage of Participants With Composite of Probable or Definite Stent Thrombosis | 0.5 (0.0 to 2.5) | 0.5 (0.0 to 2.6) |
Defined as per the Academic Research Consortium (ARC-2) criteria
| percentage of participants | Elixir Bioadaptor (ELX1805J) | Medtronic Resolute Onyx Stent |
|---|---|---|
| Percentage of Participants With Probable Stent Thrombosis | 0 (0.0 to 1.7) | 0.5 (0.0 to 2.6) |
Defined as per the Academic Research Consortium (ARC-2) criteria
| percentage of participants | Elixir Bioadaptor (ELX1805J) | Medtronic Resolute Onyx Stent |
|---|---|---|
| Percentage of Participants With Definite Stent Thrombosis | 0.5 (0.0 to 2.5) | 0 (0.0 to 1.7) |
Collected over Through 12-month post procedure. Non-serious events are listed at a 0% frequency threshold.
| Group | Deaths | Serious | Other |
|---|---|---|---|
| Elixir Bioadaptor (ELX1805J) | 1/222 (0.5%) | 60/223 (26.9%) | 128/223 (57.4%) |
| Medtronic Resolute Onyx Stent | 3/216 (1.4%) | 44/222 (19.8%) | 124/222 (55.9%) |
| Event | Elixir Bioadaptor (ELX1805J) | Medtronic Resolute Onyx Stent |
|---|---|---|
| OtherGeneral disorders | 41/223 | 25/222 |
| Revascularization Re-PCICardiac disorders | 12/223 | 10/222 |
| BleedingInjury, poisoning and procedural complications | 3/223 | 3/222 |
| MICardiac disorders | 1/223 | 2/222 |
| Death - CardiovascularCardiac disorders | 1/223 | 1/222 |
| Death - Non-CardiovascularGeneral disorders | 0/223 | 1/222 |
| Revascularization - CABGCardiac disorders | 1/223 | 1/222 |
| Death - UnknownGeneral disorders | 0/223 | 1/222 |
| Stent Thrombosis - DefiniteCardiac disorders | 1/223 | 0/222 |
| Stent Thrombosis - ProbableGeneral disorders | 0/223 | 0/222 |
| Event | Elixir Bioadaptor (ELX1805J) | Medtronic Resolute Onyx Stent |
|---|---|---|
| Chest painGeneral disorders | 8/223 | 13/222 |
| COVID-19Infections and infestations | 8/223 | 13/222 |
| Coronary artery dissectionInjury, poisoning and procedural complications | 5/223 | 10/222 |
| Myocardial necrosis marker increasedInvestigations | 9/223 | 4/222 |
| Atrial fibrillationCardiac disorders | 7/223 | 3/222 |
| Diabetes mellitusMetabolism and nutrition disorders | 1/223 | 6/222 |
| EpistaxisRespiratory, thoracic and mediastinal disorders | 3/223 | 6/222 |
| DyspnoeaRespiratory, thoracic and mediastinal disorders | 6/223 | 5/222 |
| Angina pectorisCardiac disorders | 5/223 | 5/222 |
| ContusionInjury, poisoning and procedural complications | 5/223 | 5/222 |
| Age, Continuous(years) | Elixir Bioadaptor (ELX1805J) | Medtronic Resolute Onyx Stent | Total |
|---|---|---|---|
| Mean | 67.1 ± 10.3 | 66.2 ± 10.1 | 66.6 ± 10.2 |
| Sex: Female, Male(Participants) | Elixir Bioadaptor (ELX1805J) | Medtronic Resolute Onyx Stent | Total |
|---|---|---|---|
| Female | 49 | 49 | 98 |
| Male | 174 | 173 | 347 |
| Race (NIH/OMB)(Participants) | Elixir Bioadaptor (ELX1805J) | Medtronic Resolute Onyx Stent | Total |
|---|---|---|---|
| American Indian or Alaska Native | 0 | 0 | 0 |
| Asian | 110 | 113 | 223 |
| Native Hawaiian or Other Pacific Islander | 2 | 1 | 3 |
| Black or African American | 0 | 0 | 0 |
| White | 94 | 89 | 183 |
| More than one race | 0 | 0 | 0 |
| Unknown or Not Reported | 17 | 19 | 36 |
PDFs hosted by the registry, ClinicalTrials.gov.
Ran from Dec 2020 to primary completion in Feb 2023, 26 months.
Results were first posted in Oct 2024, 1 year 7 months after primary completion.
Of 177 industry-sponsored interventional studies with no phase under Coronary Artery Disease, half reached primary completion within 24 months of starting (the median), counting those still running; a quarter within 14 and three quarters within 40. This study's 26 months is close to that.
Counting every sponsor, half of 933 studies reached it within 30 months; a quarter within 15 and three quarters within 50.
How these figures are worked out, and which studies are left out of them.
This study is active, not recruiting, as verified in Mar 2025. You cannot join it, but the record below documents what was studied.
Get an email when the registry record changes — status, dates, results — or when someone posts here.
Sign in to followQuestions and observations about this study, from anyone following it. Not medical advice, and not a channel to the study team — their contact details are on the registry record.
Sign in to join the discussion. Reading takes no account; posting does. You choose a display name, and a pseudonym is the default.
Nothing here yet. If you are running this trial, taking part in it, or weighing whether to, this is the place to say so.
Elixir Medical Corporation