An interventional study of Custom CPAP mask in Obstructive Sleep Apnea, sponsored by Beth Israel Deaconess Medical Center. Active, not recruiting at 1 site in United States. Open to participants aged 18 Years and older. Per ClinicalTrials.gov, last updated 2020-04-17.
Sponsored by Beth Israel Deaconess Medical Center · Not applicable, Interventional, and Treatment
This is a prospective pilot to investigate the effect of 3D printer customized CPAP masks on the comfort of patients with obstructive sleep apnea.
Purpose:
The purpose of this protocol is to perform a prospective pilot clinical study to customize patient CPAP masks to reduce air leak in patients with obstructive sleep apnea (OSA). Using 3-D printer-based technology modeling of patient facial features, patient FDA-approved CPAP masks will be modified by strategically applying silicone pads on the CPAP mask to mold to the specific facial features to optimize the CPAP mask-patient interface, improve CPAP mask fit and comfort, reduce air leak, limit air pressure loss and improve compliance with CPAP treatment strategy (as measured over a 30 day trial period).
Protocol:
Potential subjects for this study will be identified at the outpatient Sleep Disorders Clinic at BIDMC. Patients will have documented OSA, prescribed CPAP as standard-of-care, and demonstrate consistent problems with CPAP mask-patient interface with documented high air loss, and poor adherence/ compliance. All potential subjects will have used and will continue to use an FDA-approved CPAP mask selected by the patient.
Potential subjects (along with their FDA-approved CPAP mask) will then be referred to the BIDMC Specialties Clinic and screened, including review of the medical history of OSA, review of documented reports of excessive air leak and suboptimal adherence to CPAP, brief physical exam (esp. focusing on the head-and-neck exam) including assessment of the CPAP mask-patient interface, review of the purpose and goals of the pilot clinical study, a dynamic video of the study subject face will be performed, video downloaded to a computer which will then be used to generate a 3-dimensional plastic model of the study subject face using state-of-the-art 3D printer technology (see details below). The patient's FDA-approved CPAP mask will then be applied to his plastic model of the study subject face, and the CPAP mask modified with the application of silicon pads along the mask pillow cushion to optimize the CPAP mask-face model interface, primarily by adjustments to improve CPAP mask contact with the face model and limit the air leak during CPAP ventilation.
Once the patient's FDA-approved CPAP mask has been modified, the patient will then return to the BIDMC Specialties Clinic for a final fitting of the modified CPAP mask, with additional adjustments (as necessary) made to optimize the CPAP mask-patient interface. The study subject will then return home with his/her custom-modified CPAP mask to use as prescribed. Standard home monitoring and recording of use of the modified CPAP mask will be performed per usual case over a 30-day period. Data obtained during this 30-day period will focus on the duration of use of the modified CPAP mask, measurement of air leak and pressure loss, report of patient comfort and experience with the modified CPAP mask, and compare to data over a 30 day period using the CPAP mask prior to modification.
1,422 studies on the registry are indexed under Apnea; 159 are open to participants now.
This study's planned enrollment of 20 is below the median of 50 across 965 interventional studies indexed under Apnea.
Browse Apnea studies →Beth Israel Deaconess Medical Center is the lead sponsor of 560 studies on the registry; 80 are open to participants now.
Of its 75 completed or terminated interventional studies of FDA-regulated products, 61 (81%) have results posted.
Counted across the registry records on this site, refreshed daily.
Exclusion Criteria:
Single arm cohort study of modified mask
Device: Custom CPAP mask
Modified CPAP mask based on 3D image capture
Air leak time
Percent of air leak time over use of mask
Time frame: 30 day
CPAP mask leak volume
Volume of leak recorded on CPAP machine
Time frame: 30 day
Epworth Sleepiness Scale
Sleepiness score - Likelihood of falling asleep in various daytime activities. Total Score Range 0-24.
Time frame: 30 day
Apnea Hypopnea Index
Apnea Hypopnea Index (events/hour)
Time frame: 30 day
CPAP Inspiratory pressure
Inspiratory pressure setting on CPAP machine (cm H2O)
Time frame: 30 day
This study is active, not recruiting, as verified in Apr 2020. You cannot join it, but the record below documents what was studied.
Get an email when the registry record changes — status, dates, results — or when someone posts here.
Sign in to followQuestions and observations about this study, from anyone following it. Not medical advice, and not a channel to the study team — their contact details are on the registry record.
Sign in to join the discussion. Reading takes no account; posting does. You choose a display name, and a pseudonym is the default.
Nothing here yet. If you are running this trial, taking part in it, or weighing whether to, this is the place to say so.
Beth Israel Deaconess Medical Center