CClinicalTrials.gg
CompletedNCT03823690Updated Aug 31, 2023

EPASS Versus Uncovered Duodenal Stent for Unresectable Malignant Gastric Outlet Obstruction.

An interventional study of EUS-guided gastrojejunstomy and The pyloro-duodenal stent in Gastric Outlet Obstruction, sponsored by Chinese University of Hong Kong. Completed at 1 site in Hong Kong. Open to participants aged 18 Years and older. Per ClinicalTrials.gov, last updated 2023-08-31.

Sponsored by Chinese University of Hong Kong · Not applicable, Interventional, and Treatment

Phase
Not applicable
Study type
Interventional
Enrollment
97
Allocation
Randomized
Ages
18 Years and older
Sex
All
01

Study summary

Surgical gastrojejunostomy is the conventional treatment for palliating patients suffering from of inoperable malignant gastric outlet obstruction (GOO). Although, the procedure is associated with a high success and low re-intervention rates, there is a risk of morbidities (10% - 16%) and mortalities (7%). The placement of a pyloro-duodenal self-expandable metallic stent (SEMS) is an alternative to surgery for the palliating these patients. As compared to surgery, the procedure is associated with shorter hospital stay, reduced morbidities and cost. However, the clinical efficacy of SEMS is limited by several problems. In uncovered SEMS, the long-term patency is reduced by tumor ingrowth leading to subsequent re-stenosis. In covered SEMS, stent migration occurs at a frequency of 14-25% and it is a major obstacle to stent patency. As a result, randomized trials comparing uncovered stents and partially or fully covered stents in patients with malignant GOO have reported comparable stent patency between the two types of stents.

Recently, the creation of a gastrojejunostomy under EUS (EUS-GJ) guidance using lumen-apposing stents has been described. The procedure was associated with a technical success rate of around 90% and clinical success of 85% to 100%. The procedure holds the potential to create a gastrojejunostomy without surgery. Furthermore, there is a low risk of tumor ingrowth and stent migration, thus improving the stent patency and reducing the need of re-intervention. We have previously published a novel method of creating EUS-GJ with the use of a double balloon occluder (EPASS). The device provides a stable condition for performance of EUS-GJ and improves the safety of the procedure. However, there is limited data on how EPASS compares to endoscopic stenting. The aim of the current study is thus to compare EPASS and DS under a randomized setting.

Read the detailed description

In recent years, SEMSs have provided an attractive alternative to surgery for palliation of malignant gastric outlet obstruction. Several studies have assessed the clinical and technical success rates of pyloro-duodenal SEMS for malignant gastroduodenal obstruction. Technical success rates of 90% to 100% and clinical success of 80% to 95% was achieved.The procedure was associated with quicker recovery and reduced morbidities as compared to surgical gastrojeunostomies. However, the long-term patency of uncovered SEMS is limited by the risk of tumor ingrowth that would lead to subsequent re-stenosis of the stents requiring re-intervention. Thus to palliate malignant gastric outlet obstruction, surgical gastrojejunostomy is preferred in patients that are at good risk for surgery with prolonged life expectancy whilst insertion of pyloro-duodenal SEMS is preferred in patients that are associated with high-risk for surgery and short life expectancy.

In lieu of the above reasons, it would be the ideal situation if a gastrojejunostomy could be created endoscopically without surgery. The procedure could potentially avoid the risk of morbidities and mortalities associated with surgery whilst enjoying the superior patency associated with a gastrojejunostomy. However, a number of hurdles need to be overcome for safe creation of an anastomosis endoscopically. Firstly, the collapsed bowel (duodenum or jejunum) needs to be easily identified from the stomach. Secondly, a reliable method of creating an anastomosis needs to be available. Lastly, a device for maintaining the anastomosis between two non-adherent organs is required.

The use of EUS as a platform to create a gastrojejunostomy endoscopically may theoretically tackle all of the above hurdles. The device could be used in the stomach to visualize the adjacent duodenum or jejunum for anastomosis. A 19-gauge needle could be used to puncture the adjacent bowel for passage of a guide-wire to connect the two non-adherent organs. Thereafter, a SEMS could be placed between the two organs for creation and maintenance of the anastomosis.

Initial results of EUS-guided gastrojejunostomies from two studies have become available. Khashab et al reported EUS-GJ in 10 patients. Technical success was achieved in 9 patients (90%). Clinical success with resumption of solid oral intake was achieved in all 9 patients (100%), who underwent successful EUS-GE. 8 patients were able to tolerate almost a normal diet and/or full diet, and 1 patient tolerated a soft diet. There were no procedure-related adverse events. Mean procedure time was 96 minutes (range 45-152 minutes), and mean length of hospital stay was 2.2 days. In another multicenter study, 26 patients received EUS-GJ. Technical success was achieved in 24 patients (92 %). Clinical success was achieved in 22 patients (85 %). Of the 4 patients in whom clinical success was not achieved, 2 had persistent nausea and vomiting despite a patent EUS-GJ and required enteral feeding for nutrition, 1 died before the initiation of an oral diet, and 1 underwent surgery for suspected perforation. Adverse events, including peritonitis, bleeding, and surgery, occurred in 3 patients (11.5 %). In both of these studies, the AXIOS stent was used for creation of the anastomosis (Boston Scientific, Natick, MA, USA).

However, a common technical problem exists in both of these series. The target duodenum or jejunum needed for creation of a GJ is collapsed and it is difficult to identify the target organ by EUS from the stomach. Furthermore, the insertion of the stent for creation of the anastomosis may be difficult with a collapsed bowel and this may result in catastrophic outcomes. Our group has overcome this problem with a novel device - the double balloon occluder. The device comprises of two balloons that could occlude a segment of bowel. Saline could then be injected in to the occluded segment resulting in distension of the bowel and making it possible to be targeted by EUS from the stomach.

Our group has published the results of using the double balloon occluder in conjunction with the AXIOS stent for creation of a GJ in 20 patients (Endoscopic ultrasonography-guided double-balloon-occluded gastrojejunostomy bypass - EPASS). The technical success rate was 90% (18/20). The median intubation time from the double-balloon tube intubation to stent placement was 25.5 min (range 10-39 min). Post-treatment gastric outlet obstruction scoring system (GOOSS) score improved in all 18 cases in which EPASS was successfully performed. The mean post-GOOSS score was significantly higher than the pre-GOOSS score (0.6±0.75 vs 2.94±0.23, p\<0.001). None of the patients with successful placement of the stent suffered from adverse events or recurrent obstruction.

The outcomes of EUS-GJ were recently compared with that of conventional procedures for management of malignant GOO. In a retrospective study, EUS-GJ was compared with DS. 30 patients received EUS-GJ and 60 patients DS. The technical success rates were similar between the two groups (96.7% vs. 86.7%, P=0.07). Clinical success was also similar between the two groups (70.0% vs. 86.7%, P=0.08). The re-intervention rate was significantly higher in the ES group (43.3% vs. 3.4%, P\<0.001), whilst adverse events were comparable (13.3% vs 18.3%, P = 0.549). On multivariate analysis, DS was independently associated with need for re-intervention (OR 25.7, p=0.004). In another study, EUS-GJ (25 patients) was compared with laparoscopic gastrojejunostomy (29 patients) 20. Technical success was comparable (88% vs 100%, P = 0.11). Clinical success was similar (84% vs 90%, P = 0.11). Average post-procedure length of stay was 9.4 days in the EUS-GJ group and 8.9 days in the Lap-GJ group (P = 0.75). Adverse events were significantly more the lap-GJ group (41% vs 12%, P = 0.03).

Thus, based on the above results, EUS-GJ may be associated with improved outcomes as compared with conventional procedures for management of malignant GOO. Hence, the aim of the current study is to compare the efficacies of EPASS versus uncovered pyloro-duodenal stents (DS) in unresectable malignant gastric outlet obstruction in a randomized setting.

02

Conditions studied

  • Gastric Outlet Obstruction
03

In context

Gastric Outlet Obstruction

43 studies on the registry are indexed under Gastric Outlet Obstruction; 10 are open to participants now.

This study's enrollment of 97 is above the median of 65 across 30 interventional studies indexed under Gastric Outlet Obstruction.

Browse Gastric Outlet Obstruction studies →

Lead sponsor

Chinese University of Hong Kong is the lead sponsor of 1,419 studies on the registry; 487 are open to participants now.

Counted across the registry records on this site, refreshed daily.

04

Who can participate

Ages eligible
18 Years and older
Sexes eligible
All
Accepts healthy volunteers
No

Inclusion criteria

  • Consecutive patients ≥ 18 years old
  • Confirmed unresectable distal gastric or duodenal or pancreatico-biliary malignancies
  • Suffering from gastric outlet obstruction with a gastric outlet obstruction score of ≤ 1
  • Performance status ECOG ≤3

Exclusion criteria

Exclusion Criteria:

  • Prior metallic stent placement
  • Severe comorbidities precluding the endoscopic procedure (such as cardiopulmonary disease, sepsis, or a bleeding disorder)
  • Life expectancy of less than 1 month
  • History of gastric surgery
  • Linitus plastic
  • Multiple-level bowel obstruction confirmed on radiographic studies such as small bowel series or abdominal computed tomography
  • Coagulation disorders
  • Pregnancy
  • Unable to give informed consent
05

Study design

Phase
Not applicable
Primary purpose
Treatment
Allocation
Randomized
Intervention model
Parallel assignment
Masking
Single (Participant)
Enrollment
97 participants (actual)

Study arms

  • Active comparator
    EUS-guided gastrojejunostomy

    The procedures would be performed under conscious sedation or monitored anesthesia by a therapeutic gastroscope. The endoscope would be used to reach the site of obstruction. The stricture would be cannulated with a 0.025" or 0.035" guide-wire. The double balloon occluder would then be inserted on guidewire beyond the duodenal-jejunal flexure and the two balloons of the occluder would be inflated. A segment of duodenum/jejunum would then be occluded and saline would be injected. A linear echoendoscope would then be inserted into the stomach to guide insertion of the gastrojejunostomy stent.

    Device: EUS-guided gastrojejunstomy

  • Active comparator
    Pyloro-duodenal stent

    The uncovered DS used in this study is Wallflex (Boston, Natick, MA, USA), made of nitinol wire, with a diameter of 22mm and length of 6, 9, 12cm. This stent is a braided stent with high axial force, good flexibility and conformability.

    Device: The pyloro-duodenal stent

Interventions

  • DeviceEUS-guided gastrojejunstomy

    As listed in the arms description

    Also known as: EPASS

  • DeviceThe pyloro-duodenal stent

    As listed in the arms description

    Also known as: DS

06

What researchers measure

Primary outcomes

  1. Re-intervention rate

    The percentage of patients requiring additional endoscopic intervention due to stent dysfunction.

    Time frame: 6 months

Secondary outcomes

  1. Technical success rate

    The successful placement of a stent across the site of obstruction, as confirmed by endoscopy or fluoroscopy.

    Time frame: 1 day

  2. Clinical success rate

    Clinical success if measured by the improvement of at least 1 point in the gastric outlet obstruction score within 3 days after stent insertion.

    Time frame: 3 days

  3. Stent dysfunction rate

    Stent dysfunction is defined as the restenosis of the stent due to tumor ingrowth or overgrowth, stent migration, or fracture.

    Time frame: 6 months

  4. Duration of stent patency

    Calculated from the time of stent placement to the time of stent dysfunction.

    Time frame: 6 months

  5. Adverse events rate

    Graded according to the lexicon of endoscopic adverse events

    Time frame: 6 months

  6. Mortality

    Death from any cause

    Time frame: 6 months

  7. Gastric outlet obstruction scores (GOOS)

    Scoring system for food intake. Range of score is 0 -3 with 3 being the highest and indicating tolerating full diet

    Time frame: 6 months

  8. Quality of life assessment scores

    EORTC QLQ-C30. This questionnaire is designed to measure cancer patients' physical, psychological and social functions. The questionnaire is composed of 5 multiitem scales (physical, role, social, emotional and cognitive functioning) and 9 single items (pain, fatigue, financial impact, appetite loss, nausea/vomiting, diarrhea, constipation, sleep disturbance and quality of life). All of the scales and single-item measures range in score from 0 to 100. A high scale score represents a higher response level.

    Time frame: 6 months

  9. Quality of life assessment scores

    EORTC STO-22 modules. This the gastric cancer module to the QLQ-C30 questionnaire. The questionnaire is composed of 5 multiitem scales (dysphagia, pain, reflux, eating, anxiety) and 4 single items. All of the scales and single-item measures range in score from 0 to 100. A high scale score represents a higher response level.

    Time frame: 6 months

07

Study locations

1 site
  • Department of Surgery, Prince of Wales Hospital
    Hong Kong, Hong Kong
08

Updates

Tracking since Sep 25, 2026
No changes since tracking began. The registry record was last updated on Aug 31, 2023, before this site started recording changes on Sep 25, 2026. Its history is on ClinicalTrials.gov ↗
09

Registry details

Key details

Study ID
NCT03823690
Lead sponsor
Chinese University of Hong Kong
Responsible party
Anthony Teoh (Honorary Associate Professor, Chinese University of Hong Kong) — Principal investigator
First posted
Jan 30, 2019
Start date
Feb 1, 2020
Primary completion
May 30, 2022
Completion
May 30, 2022
Last update
Aug 31, 2023

Oversight

Data monitoring committee
Yes
FDA-regulated drug
No
FDA-regulated device
No
View the source record on ClinicalTrials.gov ↗

Not currently enrolling

This study is completed, as verified in Aug 2023. You cannot join it, but the record below documents what was studied.

Follow this study

Get an email when the registry record changes — status, dates, results — or when someone posts here.

Sign in to follow

Discussion

Questions and observations about this study, from anyone following it. Not medical advice, and not a channel to the study team — their contact details are on the registry record.

Sign in to join the discussion. Reading takes no account; posting does. You choose a display name, and a pseudonym is the default.

Nothing here yet. If you are running this trial, taking part in it, or weighing whether to, this is the place to say so.

Start the discussion