Study summary

Looking for strict normoglycemia in type 1 diabetes increases the risk of hypoglycemia, exposing to hypoglycemia unawareness. It has been shown that the early correction of hypoglycemia can help recovering the perception of hypoglycemia. The purpose of this prospective study was to assess the value of sensor-augmented insulin-pump therapy to treat hypoglycemia unawareness.

Read the detailed description

To confirm hypoglycemia unawareness, patients answered a questionnaire based on the items explored by the model of Clarke 19 about hypoglycemia and hypoglycemia awareness. The eligibility of patients was confirmed by a blinded CG M recording using the trademark iPro ™ 2 sensor for 6 days. During this period the patient reported on a logbook the perception of their hypoglycemia, symptoms and how any hypoglycemia was corrected. Hypoglycemic manifestations were divided into adrenergic (shakiness, anxiety, palpitations, sweating, hunger, nausea, headache, coldness and pallor) and neuroglycopenic effects (impaired judgment, moodiness, paresthesia, emotional lability, confusion, ataxia, double vision, amnesia, seizures and lethargy). The confrontation of hypoglycemia detected by the blinded CG M and self-reported hypoglycemia validated the diagnosis of hypoglycemia unawareness.

Patients used the Paradigm® Veo™ pump and glucose sensors (trademark : Enlite®) with an hypoglycemia alarm set at sensor glucose value of 70 mg/dL while the LG S option was set to suspend insulin delivery at a sensor glucose value of 50 mg/dL or less. These thresholds allowed an active correction of hypoglycemia by the patient between 50 and 70 mg/dL. Patients were educated to use the system and to treat and manage hypoglycemia. Pump data were uploaded using the trademark Medtronic CareLink™ Management Software for Diabetes during visits at 10 days (D10), 2 months (M2) and 3 months (M3). Hypoglycemia awareness was assessed by an initial quiz that was repeated at M3 and 6 months (M6). A blinded CGM iPro ™ 2 was also realized at M3 to validate the modifications after sensor-augmented insulin-pump therapy.

02

Conditions studied

  • Type 1 Diabetes

Keywords

  • type 1 diabetes
  • hypoglycemia unawareness
  • Insulin pump
  • Continuous glucose monitoring systems
  • Low glucose suspend
03

In context

Diabetes Mellitus, Type 1

3,614 studies on the registry are indexed under Diabetes Mellitus, Type 1; 586 are open to participants now.

This study's enrollment of 11 is below the median of 121 across 769 observational studies indexed under Diabetes Mellitus, Type 1.

Browse Diabetes Mellitus, Type 1 studies →

Lead sponsor

CHU de Reims is the lead sponsor of 275 studies on the registry; 49 are open to participants now.

Counted across the registry records on this site, refreshed daily.

04

Who can participate

Ages eligible
18 Years and older
Sexes eligible
All
Accepts healthy volunteers
No
Sampling method
Non-probability sample

Study population

Patient with hypoglycemia unawareness

Go through the criteria one by one — yes, no or not sure — and take the list to your doctor or the study team. Kept in this browser only.

Inclusion criteria

  • >18 years
  • type 1 diabetes
  • had been treated with insulin pump for more than three months
  • had hypoglycemia unawareness with a hypoglycemia perception threshold below 60 mg/dL and/or had had at least one severe hypoglycemia event in the previous year

Exclusion criteria

Exclusion Criteria:

  • > 18 years
  • any serious disease that could interfere with the study
  • pregnancy,
  • incompatibility with monitoring,
  • irregular management of diabetes,
  • hearing loss and low vision,
  • preventing them from using the devices
05

Study design

Observational model
Cohort
Time perspective
Prospective
Enrollment
11 participants (actual)
Patient registry
No

Groups and cohorts

  • diabetes group

    Patient with hypoglycemia unawareness

06

What researchers measure

Primary outcomes

  1. Glycemia measured by continuous glucose monitoring (CGM) and pump

    Time frame: Day 0

  2. Glycemia measured by continuous glucose monitoring (CGM) and pump

    Time frame: day 10

  3. Glycemia measured by continuous glucose monitoring (CGM) and pump

    Time frame: Month 2

  4. Glycemia measured by continuous glucose monitoring (CGM) and pump

    Time frame: Month 3

07

Study locations

1 site
  • Damien JOLLY
    Reims, France
08

References and documents

Publications

  • Zalzali M, Houdelet-Guerinot V, Socquard E, Thierry A, Delemer B, Lukas-Croisier C. Continuous glucose monitoring and hypoglycemia unawareness in type 1 diabetes: a pilot study. Minerva Endocrinol. 2017 Sep;42(3):195-202. doi: 10.23736/S0391-1977.16.02326-9. Epub 2015 Jul 10. PubMed 26159765 ↗
09

Updates

Tracking since Sep 25, 2026
No changes since tracking began. The registry record was last updated on Jul 30, 2018, before this site started recording changes on Sep 25, 2026. Its history is on ClinicalTrials.gov ↗
10

Registry details

Key details

Study ID
NCT03605979
Lead sponsor
CHU de Reims
Responsible party
Sponsor
First posted
Jul 30, 2018
Start date
Jul 1, 2012
Primary completion
Feb 1, 2013
Completion
Jun 1, 2013
Last update
Jul 30, 2018

Oversight

FDA-regulated drug
No
FDA-regulated device
No
View the source record on ClinicalTrials.gov ↗

Not currently enrolling

This study is completed, as verified in Jul 2018. You cannot join it, but the record below documents what was studied.

Follow this study

Get an email when the registry record changes — status, dates, results — or when someone posts here.

Sign in to follow

Discussion

Questions and observations about this study, from anyone following it. Not medical advice, and not a channel to the study team — their contact details are on the registry record.

Sign in to join the discussion. Reading takes no account; posting does. You choose a display name, and a pseudonym is the default.

Nothing here yet. If you are running this trial, taking part in it, or weighing whether to, this is the place to say so.

Start the discussion