An observational study in Arrhythmia, Hemorrhage and Septic Shock, sponsored by Tampere University Hospital. Completed at 1 site in Finland. Open to participants aged 50 Years to 120 Years. Per ClinicalTrials.gov, last updated 2019-04-09.
Sponsored by Tampere University Hospital · Observational
Help build ClinicalTrials.gg — short surveys, remote interviews or testing, in your language. Take part →
Among 17 studies in Arrhythmias, Cardiac with a site in Finland — 2 open to participants now, 2 under way, none of them phase 3. Arrhythmias, Cardiac · Finland.
Among the 17 studies in Arrhythmias, Cardiac with a site in Finland, this one is the only one that started in 2018, is one of 9 observational ones, and was the 11th registered.
1,053 studies on the registry are indexed under Arrhythmias, Cardiac; 237 are open to participants now.
Browse Arrhythmias, Cardiac studies →2 of the 17 studies in Arrhythmias, Cardiac with a site in Finland are open now. Recruiting first, the newest first:
Tampere University Hospital · Sites in Finland
Ages 18+
Medtronic · Sites in Finland, United States, Australia and 32 more countries
A study can be open while its sites in Finland have not opened yet or have stopped. Only those recruiting at a site in Finland →
Of the 168 Arrhythmias, Cardiac studies recruiting now, 120 (71%) set no upper age limit and 13 (8%) stop at 75 or younger; 31 take children under 18; 26 take healthy volunteers.
This study: 50 Years to 120 Years · all sexes.
The full table on the hub →This tab as a report to print or save as PDF → With an account.
17 studies; the count open now beside each. This study's row is marked.
First in 1983; this study’s year is marked. 1 started in 2018.
By drug class, each counting the studies that test any of its medicines:
This study's enrollment of 36 is below the median of 200 across 467 observational studies indexed under Arrhythmias, Cardiac.
Median enrollment 245 across the 8 interventional studies, 107 across the 9 observational. Of the 14 that completed or were terminated, 1 (7%) have results posted.
This tab as a report to print or save as PDF → With an account.
6 of 17 have an industry lead sponsor. The 10 most frequent:
Tampere University Hospital is the lead sponsor of 212 studies on the registry; 56 are open to participants now.
Tampere University Hospital has 4 studies filed under Arrhythmias, Cardiac — fewer than ten, so there is no comparison to draw.
None of the studies under way reaches primary completion within a year.
Among the 17 studies in Arrhythmias, Cardiac with a site in Finland, from their registry updates:
Nothing recorded among them since 2026-09-25.
This tab as a report to print or save as PDF → With an account.
Novel technology enables it to monitor noninvasively the vital signs of a patient. Such a monitoring is immediately required to improve patient safety and to reduce hospital readmissions. In this study, novel bed- and wearable sensors are studied for this purpose.
Unobtrusive bed monitoring devices have gained popularity in the area of voluntary sleep quality monitoring for wellness purposes. Most of these devices rely on the measurement of ballistocardiographic forces caused by the acceleration of blood when the heart pumps it to aorta, forces caused by respiration movements and other movements of the person being monitored. A thin film-type force sensor placed under the bed mattress, between the matrices or under the bed sheet is often used for measuring these forces. While proven to provide adequate reliability and accuracy for wellness monitoring of healthy people, unobtrusive bed monitoring solutions have not yet been widely deployed in hospital patient monitoring even though there would be much use for such technology e.g. in regular hospital wards where currently the amount of patient monitoring is very limited.
If proven operational in this application, bed monitoring technology would provide tremendous benefits in both clinical and home monitoring scenarios. Wrist worn pulse plethysmography (PPG) devices have increased their popularity as heart rate monitors, referred as optical heart rate monitors (OHR) for sports and wellness in recent years and their ability to measure average heart rate during movement and beat-to-beat heart rate while at rest accurately with healthy people has been shown.
The objective of the study is to collect ECG and movement data measured with a wearable ECG monitor and simultaneously record data with unobtrusive bed sensor and wrist worn PPG device. Data recorded with the bed and wrist sensors and vital parameters calculated from that or provided by the monitoring devices directly will be compared with the reference.
The purpose of the study is to gain knowledge about the feasibility of unobtrusive bed and wrist monitoring devices for patient monitoring. The collected data will directly provide information on the accuracy of the current algorithms of the monitors. Besides this evaluation, the collected data will be used in developing new algorithms for detection of cardiac problems.
The study includes collection of data from vascular patients referred to surgical operation in Tampere University Hospital. Data collection takes place at vascular surgical ward where one dedicated research bed is equipped with bed monitoring devices. Another group of subjects is formed by healthy volunteers.
Caucasian
Go through the criteria one by one — yes, no or not sure — and take the list to your doctor or the study team. Kept in this browser only.
Exclusion Criteria:
Patient subjects are recruited from patients referred for vascular surgical procedure in Tampere University Hospital. Bed-, wrist- and ECG-sensor monitoring
Diagnostic Test: Bed-, wrist- and ECG-sensor monitoring
Healthy volunteer subjects will be recruited mainly from the students of Tampere University of Technology. Bed-, wrist- and ECG-sensor monitoring
Diagnostic Test: Bed-, wrist- and ECG-sensor monitoring
Bed-, wrist- and ECG-sensor monitoring
Accuracy and precision of heart rate (1/s) measurement by a bed sensor
Comparison of bed sensor derived heart rate with ECG reference to determine accuracy and precision of heart rate measurement by a bed sensor
Time frame: 24 hours
Accuracy and precision of heart rate variability (ms) measurement by a bed sensor
Comparison of bed sensor derived heart rate variability with ECG reference
Time frame: 24 hours
Accuracy and precision of respiratory rate (1/min) measurement by a bed sensor
Comparison of bed sensor derived respiratory rate measurement with accelerometer derived reference
Time frame: 24 hours
Accuracy and precision of body movement detection
Comparison of bed sensor derived body movement with accelerometer derived reference
Time frame: 24 hours
Duration of light sleep
Measurement of light sleep duration by bed-worn sensor
Time frame: 24 hours
Duration of rapid eye movement (REM) sleep
Measurement of REM sleep duration by bed-worn sensor
Time frame: 24 hours
Duration of deep sleep
Measurement of deep sleep duration by bed-worn sensor
Time frame: 24 hours
Plan to share: No
No publications or documents are linked to this record.
Ran from Apr 2018 to primary completion in Dec 2018, 8 months.
Of 190 non-industry observational studies under Arrhythmias, Cardiac, half reached primary completion within 45 months of starting (the median), counting those still running; a quarter within 22 and three quarters within 140. This study's 8 months is below that.
Counting every sponsor, half of 259 studies reached it within 38 months; a quarter within 16 and three quarters within 97.
How these figures are worked out, and which studies are left out of them.
This study is completed, as verified in Apr 2019. You cannot join it, but the record below documents what was studied.
Get an email when the registry record changes — status, dates, results — or when someone posts here.
Sign in to followQuestions and observations about this study, from anyone following it. Not medical advice, and not a channel to the study team — their contact details are on the registry record.
Sign in to join the discussion. Reading takes no account; posting does. You choose a display name, and a pseudonym is the default.
Nothing here yet. If you are running this trial, taking part in it, or weighing whether to, this is the place to say so.