An interventional study of X-PSI Knee System in Knee Osteoarthritis and Post-traumatic Osteoarthritis, sponsored by Zimmer, GmbH. Terminated at 4 sites in 3 countries. Open to participants aged 18 Years and older. Per ClinicalTrials.gov, last updated 2021-10-06.
Sponsored by Zimmer, GmbH · Not applicable, Interventional, and Treatment
Help build ClinicalTrials.gg — short surveys, remote interviews or testing, in your language. Take part →
Among 24 studies in Osteoarthritis, Knee by Zimmer Biomet — 1 open to participants now, 5 under way, none of them phase 3. Osteoarthritis, Knee · Zimmer Biomet.
Among the 24 studies in Osteoarthritis, Knee by Zimmer Biomet, this one is the 16th largest by enrollment of the 17 interventional ones that give a count, is one of 2 that started in 2018, is one of 16 with no phase, and was the 15th registered.
3,297 studies on the registry are indexed under Osteoarthritis, Knee; 624 are open to participants now.
Browse Osteoarthritis, Knee studies →1 of the 24 studies in Osteoarthritis, Knee by Zimmer Biomet is open now, in 1 country. Recruiting first, the newest first:
Zimmer Biomet · Sites in United States
Ages 18+
By country, each count listing its studies:
Of the 385 Osteoarthritis, Knee studies recruiting now, 178 (46%) set no upper age limit and 114 (30%) stop at 75 or younger; 19 take children under 18; 39 take healthy volunteers.
This study: 18 Years and older · all sexes · no healthy volunteers.
The full table on the hub →This tab as a report to print or save as PDF → With an account.
24 studies; the count open now beside each. This study's row is marked.
First in 2009; this study’s year is marked. 2 started in 2018.
This study's enrollment of 8 is below the median of 68 across 2,719 interventional studies indexed under Osteoarthritis, Knee.
Median enrollment 93 across the 17 interventional studies, 380 across the 7 observational. Of the 17 that completed or were terminated, 12 (71%) have results posted.
This tab as a report to print or save as PDF → With an account.
This study is registered under Zimmer, GmbH, one of the names counted as Zimmer Biomet. Under that name alone:
Zimmer, GmbH is the lead sponsor of 5 studies on the registry; 1 is open to participants now.
None of the studies under way reaches primary completion within a year.
Among the 24 studies in Osteoarthritis, Knee by Zimmer Biomet, from their registry updates:
Nothing recorded among them since 2026-09-25.
This tab as a report to print or save as PDF → With an account.
The goal of this study is to establish the accuracy of the new X-PSI Knee System guides by analyzing early postoperative (4-6 weeks) imaging data with regards to the mechanical alignment and compare them with preoperative planning imaging data. Mechanical alignment in the hip-knee-ankle (HKA) frontal plane with X-PSI Knee System will be measured and compared with results reported in the literature using a conventional (non-guided) approach.
Hypothesis: The use of the new X-PSI Knee System achieves the same accuracy with respect to mechanical alignment as with conventional instrumentation.
Patient-specific instruments (PSI) provide surgeons with an anatomically personalized surgery tool. The newly developed and CE-marked X-PSI Knee System is based on long leg x-rays that are used to generate a pre-operative 3D model of the knee. The total knee replacement surgery will be planned according to this 3D model.
The aim of this multi-center, prospective, non-controlled post-market study is to scientifically document the accuracy, cost-effectiveness and subsequent clinical performance of the X-PSI Knee System. The X-PSI pin guides are designed to facilitate a more simplified, efficient and customized TKA procedure compared to conventional, non-guided instrumentation.
To evaluate the accuracy of the X-PSI Knee System, early postoperative (4-6 weeks) imaging data will be analysed with regards to the mechanical alignment (hip-knee-ankle angle) of the leg and matched to preoperative planning imaging data. The X-PSI Knee System cohort will then be compared with current literature (70% of cases within ±3 degrees) where patients were conventionally operated with non-guided surgery. No control group will be studied.
The cost-effectiveness of the X-PSI Knee System will be evaluated with an efficiency matrix to record OR set-up time, surgery time and post-processing time.
Clinical outcome data of the patients will be evaluated 4-6 weeks and 1 year post-surgery with the help of patient questionnaires (VAS pain scale, EQ-5D and Oxford Knee Score), a physical exam and the assessment of radiographs.
The study population will be compromised of males and females requiring total knee arthroplasty and satisfy the inclusion/exclusion criteria. The study will last one (1) year from the time of surgery. The collected data aim to improve the treatment and quality of life of patients suffering from degenerative joint diseases. In addition, shorter surgery times possibly result in reduced risk of infection, decreased time of anaesthesia and better cost-effectiveness.
Go through the criteria one by one — yes, no or not sure — and take the list to your doctor or the study team. Kept in this browser only.
Exclusion Criteria:
Underlined terms in the criteria open these too. Explained by clinicaltrials.gg, not part of the registry record. The study team decides who can take part.
Before you join, the study team explains what taking part involves — its purpose, what happens, the risks and possible benefits — and answers your questions, so you can decide freely. Consent is usually recorded on a form (the informed consent form, ICF) signed by you or, where the law allows, by someone legally authorized to decide for you.
You can keep asking questions during the study, you are told of new information that matters, and you can choose to leave at any time.
Informed consent
Before you join, the study team explains what taking part involves — its purpose, what happens, the risks and possible benefits — and answers your questions, so you can decide freely. Consent is usually recorded on a form (the informed consent form, ICF) signed by you or, where the law allows, by someone legally authorized to decide for you.
You can keep asking questions during the study, you are told of new information that matters, and you can choose to leave at any time.
Explained by clinicaltrials.gg, not part of the registry record. The study team decides who can take part.
Patients undergoing total knee arthroplasty
Device: X-PSI Knee System
Patients are operated with X-PSI Knee System guides
Mechanical Leg Alignment
Achievement of mechanical leg alignment in HKA frontal plane (± 3 degrees) with X-PSI Knee System is as accurate as with standard instrumentation at 4-6 weeks post operation. The X-PSI Knee System cohort will be compared with current literature (70% of cases within ± 3 degrees). No control group will be studied.
Time frame: 4-6 weeks post-surgery
Cost-effectiveness of the X-PSI Knee System Using an Efficiency Matrix
The cost-effectiveness of the X-PSI Knee System will be measured using an efficiency matrix where OR set-up time, surgery time and tray sterilization times will be collected and compared to conventional TKA procedures.
Time frame: During surgery, immediate pre- and post-surgery processing time
Patient Clinical Outcome Measure: Visual Analog Score Pain
Obtain clincal outcome data on patients treated using the X-PSI Knee System in primary TKA procedures. The pain level will be measured using a 10 cm long scale indicating no pain (0) and worst imaginable pain (10).
Time frame: Baseline, 4-6 weeks and 1 year post-surgery
Patient Clinical Outcome Measure: Oxford Knee Score
The Oxford Knee Score (OKS) is a 12-item patient-reported patient reported outcome specifically designed and developed to assess function and pain after total knee replacement (TKR) surgery (arthroplasty). The OKS provides a single summed score which reflects the severity of problems that the respondent has with their knee. Each question (item) is scored from 0 to 4 with 0 being the worst outcome and 4 being the best outcome. The scores are then summed to produce an overall score running from 0 (worst possible) to 48 (best outcome).
Time frame: Baseline, 4-6 weeks and 1 year post-surgery
Patient Clinical Outcome Measure: EQ-5D Visual Analogue Scale (VAS)
Obtain clincal outcome data on patients treated using the X-PSI Knee System in primary TKA procedures. The EQ-5D VAS is a score to measure general quality of life. The general health state will be assessed on a patient self-reported Visual Analog Scale (VAS) where the endpoints are labelled 0 (worst imaginable health state) to 100 (best imaginable health state). The VAS is used as a quantitative measure of health outcome that reflects the patient's own judgement.
Time frame: Baseline, 4-6 weeks and 1 year post-surgery
Patient Clinical Outcome Measure: EQ-5D-3L Descriptive System
The EQ-5D-3L descriptive system comprises the following five dimensions: mobility, self-care, usual activities, pain/discomfort and anxiety/depression. Each dimension has 3 levels: no problems, some problems, and extreme problems.
Time frame: Baseline, 4-6 weeks and 1 year post-surgery
| Milestone | Total Knee Arthroplasty |
|---|---|
| Started | 8 |
| Completed | 2 |
| Not completed | 6 |
| Withdrew: Protocol violation | 5 |
| Withdrew: The study was stopped before the patient reached the final 1 year follow-up | 1 |
Achievement of mechanical leg alignment in HKA frontal plane (± 3 degrees) with X-PSI Knee System is as accurate as with standard instrumentation at 4-6 weeks post operation. The X-PSI Knee System cohort will be compared with current literature (70% of cases within ± 3 degrees). No control group will be studied.
No measurements were reported for this outcome.
The cost-effectiveness of the X-PSI Knee System will be measured using an efficiency matrix where OR set-up time, surgery time and tray sterilization times will be collected and compared to conventional TKA procedures.
No measurements were reported for this outcome.
Obtain clincal outcome data on patients treated using the X-PSI Knee System in primary TKA procedures. The pain level will be measured using a 10 cm long scale indicating no pain (0) and worst imaginable pain (10).
| units on a scale | Total Knee Arthroplasty |
|---|---|
| Baseline | 8.2 ± 0.9 |
| 4-6 weeks post-surgery | 3.7 ± 2.4 |
| 1 year post-surgery | 1.1 ± 0.4 |
The Oxford Knee Score (OKS) is a 12-item patient-reported patient reported outcome specifically designed and developed to assess function and pain after total knee replacement (TKR) surgery (arthroplasty). The OKS provides a single summed score which reflects the severity of problems that the respondent has with their knee. Each question (item) is scored from 0 to 4 with 0 being the worst outcome and 4 being the best outcome. The scores are then summed to produce an overall score running from 0 (worst possible) to 48 (best outcome).
| score on a scale | Total Knee Arthroplasty |
|---|---|
| Baseline | 18.3 ± 6.6 |
| 4-6 weeks post-surgery | 30.3 ± 5.3 |
| 1 year post-surgery | 45.0 ± 2.0 |
Obtain clincal outcome data on patients treated using the X-PSI Knee System in primary TKA procedures. The EQ-5D VAS is a score to measure general quality of life. The general health state will be assessed on a patient self-reported Visual Analog Scale (VAS) where the endpoints are labelled 0 (worst imaginable health state) to 100 (best imaginable health state). The VAS is used as a quantitative measure of health outcome that reflects the patient's own judgement.
| score on a scale | Total Knee Arthroplasty |
|---|---|
| Baseline | 73.3 ± 24.9 |
| 4-6 weeks post-surgery | 63.3 ± 12.5 |
| 1 year post-surgery | 91.5 ± 3.5 |
The EQ-5D-3L descriptive system comprises the following five dimensions: mobility, self-care, usual activities, pain/discomfort and anxiety/depression. Each dimension has 3 levels: no problems, some problems, and extreme problems.
| participants | Total Knee Arthroplasty |
|---|---|
| Baseline - patients reprting any problem (i.e some problems/ extreme problems) : Mobility | 2 |
| Baseline - patients reprting any problem (i.e some problems/ extreme problems) : Self-Care | 1 |
| Baseline - patients reprting any problem (i.e some problems/ extreme problems) : Usual Activities | 2 |
| Baseline - patients reprting any problem (i.e some problems/ extreme problems) : Pain/Discomfort | 3 |
| Baseline - patients reprting any problem (i.e some problems/ extreme problems) : Anxiety | 1 |
| 4- weeks post-surgery patients reprting any problem (i.e some problems/ extreme problems) : Mobility | 2 |
| 4- wks post-OP patients reprting any problem (i.e some problems/ extreme problems) : Self-Care | 0 |
| 4- wks post-OP patients reprting any problem (i.e some problems/ extreme problems): Usual Activities | 2 |
| 4- wks post-OP patients reprting any problem (i.e some problems/ extreme problems) : Pain/Discomfort | 3 |
| 4- wks post-OP patients reprting any problem (i.e some problems/ extreme problems) : Anxiety | 2 |
| 1 year post-OP patients reprting any problem (i.e some problems/ extreme problems) : Mobility | 0 |
| 1 year post-surgery patients reprting any problem (i.e some problems/ extreme problems) : Self-Care | 0 |
| 1 year post-OP patients reprting any problem (i.e some problems/ extreme problems): Usual Activities | 0 |
| 1 year post-OP patients reprting any problem (i.e some problems/ extreme problems) : Pain/Discomfort | 1 |
| 1 year post-OP patients reprting any problem (i.e some problems/ extreme problems) : Anxiety | 0 |
Collected over 1 year starting from day of surgery. Non-serious events are listed at a 0% frequency threshold.
| Group | Deaths | Serious | Other |
|---|---|---|---|
| Total Knee Arthroplasty | 0/3 (0%) | 0/3 (0%) | 0/3 (0%) |
Baseline data collected and reported for those participants that underwent surgery with X-PSI Knee System
| Age, Categorical(Participants) | Total Knee Arthroplasty |
|---|---|
| <=18 years | 0 |
| Between 18 and 65 years | 2 |
| >=65 years | 1 |
| Sex: Female, Male(Participants) | Total Knee Arthroplasty |
|---|---|
| Female | 0 |
| Male | 3 |
| Race and Ethnicity Not Collected(Participants) | Total Knee Arthroplasty |
|---|
| Region of Enrollment(Participants) | Total Knee Arthroplasty |
|---|---|
| Germany | 3 |
PDFs hosted by the registry, ClinicalTrials.gov.
Plan to share: No
Ran from Oct 2018 to primary completion in Dec 2019, 14 months.
Results were first posted in Oct 2021, 1 year 9 months after primary completion.
How these figures are worked out, and which studies are left out of them.
This study is terminated, as verified in Sep 2021. You cannot join it, but the record below documents what was studied.
Get an email when the registry record changes — status, dates, results — or when someone posts here.
Sign in to followQuestions and observations about this study, from anyone following it. Not medical advice, and not a channel to the study team — their contact details are on the registry record.
Sign in to join the discussion. Reading takes no account; posting does. You choose a display name, and a pseudonym is the default.
Nothing here yet. If you are running this trial, taking part in it, or weighing whether to, this is the place to say so.