ClinicalTrials.gg
CompletedNCT02467179Amigo-AFLUpdated Jun 27, 2019Results posted

Evaluation of the Amigo Robotic System for Ablation of the Cavo-Tricuspid Isthmus

An interventional study of Amigo™ Robotic Catheter Manipulation and Manual Catheter Manipulation in Atrial Fibrillation and Atrial Flutter, sponsored by University of California, San Diego. Completed at 1 site in United States. Open to participants aged 18 Years and older. Per ClinicalTrials.gov, last updated 2019-06-27.

Sponsored by University of California, San Diego · Not applicable, Interventional, and Treatment

How we know

From the registry’s dates

  • Registered 3 months after the study started (first participant enrolled Mar 2015, registered Jun 2015).

Help build ClinicalTrials.gg — short surveys, remote interviews or testing, in your language. Take part →

Phase
Not applicable
Study type
Interventional
Enrollment
50
Allocation
Randomized
Ages
18 Years and older
Sex
All
01

Where this study stands

Counted across the records on this site · 2026-11-26

Among 994 studies in Atrial Fibrillation with a site in United States — 161 open to participants now, 221 under way, 15 of them phase 3. Atrial Fibrillation · United States.

Enrollment
488th of 680
50 · median 128
Started
2015
with 27 others
No phase
406 of 994
68 open now
Registered
390th of 994
by date

Among the 994 studies in Atrial Fibrillation with a site in United States, this one is the 488th largest by enrollment of the 680 interventional ones that give a count, is one of 28 that started in 2015, is one of 406 with no phase, and was the 390th registered.

Atrial Fibrillation

4,021 studies on the registry are indexed under Atrial Fibrillation; 965 are open to participants now.

Browse Atrial Fibrillation studies →

Open to participants now

161 of the 994 studies in Atrial Fibrillation with a site in United States are open now. Recruiting first, the newest first:

156 more — sign in →

All 161 open studies →

A study can be open while its sites in United States have not opened yet or have stopped. Only those recruiting at a site in United States →

Who these studies take

Of the 614 Atrial Fibrillation studies recruiting now, 411 (67%) set no upper age limit and 44 (7%) stop at 75 or younger; 20 take children under 18; 43 take healthy volunteers.

This study: 18 Years and older · all sexes · no healthy volunteers.

The full table on the hub →

This tab as a report to print or save as PDF → With an account.

Was this useful?
Get alerts for this landscapeDownload CSVNarrow it in search →With an account: a weekly mail of what changed among 994 studies in Atrial Fibrillation with a site in United States, or all of them as a file.
02

Study summary

The purpose of this study is to compare standard manual and robotically controlled catheter ablation of the cavo-tricuspid isthmus (CTI) as a treatment for atrial flutter. Ablation of the CTI is standard treatment for patients with a history of atrial flutter, and those undergoing ablation for atrial fibrillation. Both manual and robotic catheter manipulation are used in standard clinical practice at The University of California, San Diego (UCSD) for ablation.

Read the detailed description

Dr. Gregory Feld, M.D. is conducting a research study to find out more about the effects of using the Amigo™ Robotic System for ablation of the cavo-tricuspid isthmus (flutter isthmus) on catheter stability (stabilization of the catheter during the procedure in order to prevent movement and dislodgement) using a combination of contact force (a measurement of the force applied by the catheter tip against the tissue during the ablation procedure), location, and duration measurements during ablation of the atrial flutter circuit. Published studies have indicated that robotic catheter manipulation is safe, may reduce patient and physician x-ray exposure, and ablation procedure time. Measuring contact force has also been shown to improve both short-term and long-term procedure success. However, research on ablation of the CTI specifically, is limited. This is a randomized study comparing robotic catheter manipulation using the Amigo Robotic System to manual catheter manipulation for ablation of the CTI on measures including catheter stability, contact force, procedure time, and fluoroscopy (X-ray) time.

The ablation procedure is standard of care, however, if patients chose to enroll in the study they will be randomized to one of two groups: either manual or robotic catheter manipulation. Throughout the procedure, research personnel will collect information from the procedure including measurements of contact force, catheter stability, procedure duration, and fluoroscopy (X-ray) time. If, in addition to ablation of the cavo-tricuspid isthmus for atrial flutter, a patient is scheduled to undergo ablation of the left atrium for atrial fibrillation or left atrial flutter, this will be performed subsequently in a standard manner, and will not be considered part of the research. Ablation of the CTI generally takes 45-60 minutes regardless of the technique used for manipulation of the catheters.

The patient's participation in the study will only last one day, the length of study procedure. There is no follow up associated with this study. All subjects will received standard of care treatment following their ablation.

03

Conditions studied

  • Atrial Fibrillation
  • Atrial Flutter

Keywords

  • Arrhythmia
  • cavo-tricuspid isthmus
  • atrial fibrillation
  • atrial fibrillation ablation
04

Who can participate

Ages eligible
18 Years and older
Sexes eligible
All
Accepts healthy volunteers
No

Go through the criteria one by one — yes, no or not sure — and take the list to your doctor or the study team. Kept in this browser only.

Inclusion criteria

  • Must be scheduled to undergo radiofrequency catheter ablation of the cavo-tricuspid isthmus for atrial fibrillation (AF) or atrial flutter (AFL) according to appropriate clinical indications.
  • Must be able and willing to provide written
  • Must be at least 18 years old.

Exclusion criteria

Exclusion Criteria:

  • Patient's refusal to participate in the study
  • Lack of indication for CTI ablation (eg: prior CTI ablation with persistent bidirectional isthmus block)
  • Pregnancy
Terms in these criteria, in plain language(1)

Underlined terms in the criteria open these too. Explained by clinicaltrials.gg, not part of the registry record. The study team decides who can take part.

Informed consent

Before you join, the study team explains what taking part involves — its purpose, what happens, the risks and possible benefits — and answers your questions, so you can decide freely. Consent is usually recorded on a form (the informed consent form, ICF) signed by you or, where the law allows, by someone legally authorized to decide for you.

You can keep asking questions during the study, you are told of new information that matters, and you can choose to leave at any time.

05

Study design

Phase
Not applicable
Primary purpose
Treatment
Allocation
Randomized
Intervention model
Parallel assignment
Masking
None (open label)
Enrollment
50 participants (actual)

Study arms

  • Active comparator
    Manual Catheter Manipulation

    25 subjects will be randomized to this arm. Manual catheter ablation of the cavo-tricuspid isthmus will be performed.

    Device: Manual Catheter Manipulation

  • Experimental
    Amigo™ Robotic Catheter Manipulation

    25 subjects will be randomized to this arm. Robotic catheter ablation of the cavo-tricuspid isthmus with the Amigo Catheter System will be performed.

    Device: Amigo™ Robotic Catheter Manipulation

Interventions

  • DeviceAmigo™ Robotic Catheter Manipulation

    Ablation is a standard procedure that patients may undergo for the atrial flutter. In this study, this group will be assigned to robotic catheter manipulation.

    Also known as: cavo-tricuspid isthmus ablation, atrial flutter ablation, arrhythmia, radiofrequency catheter ablation

  • DeviceManual Catheter Manipulation

    Ablation is a standard procedure that patients may undergo for the atrial flutter. In this study, this group will be assigned to manual catheter manipulation.

    Also known as: cavo-tricuspid isthmus ablation, atrial flutter ablation, arrhythmia, radiofrequency catheter ablation

06

What researchers measure

Primary outcomes

  1. Contact Force Through Measurement of Force-time Integral (FTI)

    Determination of the average total contact force (measured in gs) achieved during each ablation lesion using the Carto Mapping System

    Time frame: At time of the ablation procedure, which typically lasts 30-60 minutes

Secondary outcomes

  1. Fluoroscopy Time Measurements

    Determine fluoroscopy time to reach CTI block.

    Time frame: at time of ablation procedure

07

Results

Posted Jun 27, 2019

Participant flow

Participant flow — Overall Study
MilestoneManual Catheter ManipulationAmigo™ Robotic Catheter Manipulation
Started2525
Completed2525
Not completed00

Outcome measures

PrimaryContact Force Through Measurement of Force-time Integral (FTI)

Determination of the average total contact force (measured in gs) achieved during each ablation lesion using the Carto Mapping System

Time frame:
At time of the ablation procedure, which typically lasts 30-60 minutes
Reported as:
Mean · gm/s
Contact Force Through Measurement of Force-time Integral (FTI)
gm/sManual Catheter ManipulationAmigo™ Robotic Catheter Manipulation
Contact Force Through Measurement of Force-time Integral (FTI)471 ± 179571 ± 278
SecondaryFluoroscopy Time Measurements

Determine fluoroscopy time to reach CTI block.

Time frame:
at time of ablation procedure
Reported as:
Mean · minutes
Fluoroscopy Time Measurements
minutesManual Catheter ManipulationAmigo™ Robotic Catheter Manipulation
Fluoroscopy Time Measurements3.8 ± 2.36.8 ± 4.4

Adverse events

Collected over From the time of enrollment to completion of the ablation procedure (which usually lasted 30-60 minutes).. Non-serious events are listed at a 0% frequency threshold.

Adverse event summary by group
GroupDeathsSeriousOther
Manual Catheter Manipulation0/25 (0%)0/25 (0%)0/25 (0%)
Amigo™ Robotic Catheter Manipulation0/25 (0%)0/25 (0%)0/25 (0%)

Baseline characteristics

Age, Categorical
Age, Categorical(Participants)Manual Catheter ManipulationAmigo™ Robotic Catheter ManipulationTotal
<=18 years000
Between 18 and 65 years252550
>=65 years000
Age, Continuous
Age, Continuous(years)Manual Catheter ManipulationAmigo™ Robotic Catheter ManipulationTotal
Mean63 ± 1263 ± 1263 ± 12
Sex: Female, Male
Sex: Female, Male(Participants)Manual Catheter ManipulationAmigo™ Robotic Catheter ManipulationTotal
Female8614
Male171936
Race and Ethnicity Not Collected
Race and Ethnicity Not Collected(Participants)Manual Catheter ManipulationAmigo™ Robotic Catheter ManipulationTotal
Count of participants——0
Region of Enrollment
Region of Enrollment(participants)Manual Catheter ManipulationAmigo™ Robotic Catheter ManipulationTotal
United States252550
08

Study locations

1 site
  • Sulpizio Cardiovascular Center
    La Jolla, California 92037, United States
09

References and documents

Publications

  • Wood MA, Orlov M, Ramaswamy K, Haffajee C, Ellenbogen K; Stereotaxis Heart Study Investigators. Remote magnetic versus manual catheter navigation for ablation of supraventricular tachycardias: a randomized, multicenter trial. Pacing Clin Electrophysiol. 2008 Oct;31(10):1313-21. doi: 10.1111/j.1540-8159.2008.01183.x. PubMed 18811813 ↗
  • Proietti R, Pecoraro V, Di Biase L, Natale A, Santangeli P, Viecca M, Sagone A, Galli A, Moja L, Tagliabue L. Remote magnetic with open-irrigated catheter vs. manual navigation for ablation of atrial fibrillation: a systematic review and meta-analysis. Europace. 2013 Sep;15(9):1241-8. doi: 10.1093/europace/eut058. Epub 2013 Apr 12. PubMed 23585253 ↗
  • Hlivak P, Mlcochova H, Peichl P, Cihak R, Wichterle D, Kautzner J. Robotic navigation in catheter ablation for paroxysmal atrial fibrillation: midterm efficacy and predictors of postablation arrhythmia recurrences. J Cardiovasc Electrophysiol. 2011 May;22(5):534-40. doi: 10.1111/j.1540-8167.2010.01942.x. Epub 2010 Nov 23. PubMed 21091964 ↗
  • Feld G, Wharton M, Plumb V, Daoud E, Friehling T, Epstein L; EPT-1000 XP Cardiac Ablation System Investigators. Radiofrequency catheter ablation of type 1 atrial flutter using large-tip 8- or 10-mm electrode catheters and a high-output radiofrequency energy generator: results of a multicenter safety and efficacy study. J Am Coll Cardiol. 2004 Apr 21;43(8):1466-72. doi: 10.1016/j.jacc.2003.11.036. PubMed 15093885 ↗
  • Sawhney N, Anousheh R, Chen WC, Narayan S, Feld GK. Five-year outcomes after segmental pulmonary vein isolation for paroxysmal atrial fibrillation. Am J Cardiol. 2009 Aug 1;104(3):366-72. doi: 10.1016/j.amjcard.2009.03.044. Epub 2009 Jun 6. PubMed 19616669 ↗
  • Steinberg JS, Palekar R, Sichrovsky T, Arshad A, Preminger M, Musat D, Shaw RE, Mittal S. Very long-term outcome after initially successful catheter ablation of atrial fibrillation. Heart Rhythm. 2014 May;11(5):771-6. doi: 10.1016/j.hrthm.2014.02.003. Epub 2014 Feb 4. PubMed 24508206 ↗
  • Akca F, Janse P, Theuns DA, Szili-Torok T. A prospective study on safety of catheter ablation procedures: contact force guided ablation could reduce the risk of cardiac perforation. Int J Cardiol. 2015 Jan 20;179:441-8. doi: 10.1016/j.ijcard.2014.11.105. Epub 2014 Nov 13. PubMed 25465303 ↗
  • Sigmund E, Puererfellner H, Derndorfer M, Kollias G, Winter S, Aichinger J, Nesser HJ, Martinek M. Optimizing radiofrequency ablation of paroxysmal and persistent atrial fibrillation by direct catheter force measurement-a case-matched comparison in 198 patients. Pacing Clin Electrophysiol. 2015 Feb;38(2):201-8. doi: 10.1111/pace.12549. Epub 2014 Dec 2. PubMed 25469738 ↗
  • Jarman JWE, Panikker S, DAS M, Wynn GJ, Ullah W, Kontogeorgis A, Haldar SK, Patel PJ, Hussain W, Markides V, Gupta D, Schilling RJ, Wong T. Relationship between contact force sensing technology and medium-term outcome of atrial fibrillation ablation: a multicenter study of 600 patients. J Cardiovasc Electrophysiol. 2015 Apr;26(4):378-384. doi: 10.1111/jce.12606. Epub 2015 Feb 11. PubMed 25546580 ↗
  • le Polain de Waroux JB, Weerasooriya R, Anvardeen K, Barbraud C, Marchandise S, De Meester C, Goesaert C, Reis I, Scavee C. Low contact force and force-time integral predict early recovery and dormant conduction revealed by adenosine after pulmonary vein isolation. Europace. 2015 Jun;17(6):877-83. doi: 10.1093/europace/euu329. Epub 2015 Jan 24. PubMed 25618742 ↗
  • Arujuna A, Karim R, Zarinabad N, Gill J, Rhode K, Schaeffter T, Wright M, Rinaldi CA, Cooklin M, Razavi R, O'Neill MD, Gill JS. A randomized prospective mechanistic cardiac magnetic resonance study correlating catheter stability, late gadolinium enhancement and 3 year clinical outcomes in robotically assisted vs. standard catheter ablation. Europace. 2015 Aug;17(8):1241-50. doi: 10.1093/europace/euu364. Epub 2015 Feb 16. PubMed 25687748 ↗
  • Shurrab M, Danon A, Lashevsky I, Kiss A, Newman D, Szili-Torok T, Crystal E. Robotically assisted ablation of atrial fibrillation: a systematic review and meta-analysis. Int J Cardiol. 2013 Nov 5;169(3):157-65. doi: 10.1016/j.ijcard.2013.08.086. Epub 2013 Sep 10. PubMed 24063921 ↗
  • Lopez-Gil M, Salgado R, Merino JL, Datino T, Figueroa J, Arenal A, Mejia E, Salguero R, Fontenla A, Arribas F. Cavo-tricuspid isthmus radiofrequency ablation using a novel remote navigation catheter system in patients with typical atrial flutter. Europace. 2014 Apr;16(4):558-62. doi: 10.1093/europace/eut285. Epub 2013 Sep 20. PubMed 24058180 ↗
  • Datino T, Arenal A, Pelliza M, Hernandez-Hernandez J, Atienza F, Gonzalez-Torrecilla E, Avila P, Bravo L, Fernandez-Aviles F. Comparison of the safety and feasibility of arrhythmia ablation using the Amigo Robotic Remote Catheter System versus manual ablation. Am J Cardiol. 2014 Mar 1;113(5):827-31. doi: 10.1016/j.amjcard.2013.11.030. Epub 2013 Dec 12. PubMed 24440330 ↗
  • Zhang W, Jia N, Su J, Lin J, Peng F, Niu W. The comparison between robotic and manual ablations in the treatment of atrial fibrillation: a systematic review and meta-analysis. PLoS One. 2014 May 6;9(5):e96331. doi: 10.1371/journal.pone.0096331. eCollection 2014. PubMed 24800808 ↗
  • Wutzler A, Wolber T, Parwani AS, Huemer M, Attanasio P, Blaschke F, Haegeli L, Haverkamp W, Duru F, Boldt LH. Robotic ablation of atrial fibrillation with a new remote catheter system. J Interv Card Electrophysiol. 2014 Sep;40(3):215-9. doi: 10.1007/s10840-014-9895-x. Epub 2014 Apr 29. PubMed 24771262 ↗
  • Thomas D, Scholz EP, Schweizer PA, Katus HA, Becker R. Initial experience with robotic navigation for catheter ablation of paroxysmal and persistent atrial fibrillation. J Electrocardiol. 2012 Mar;45(2):95-101. doi: 10.1016/j.jelectrocard.2011.05.005. Epub 2011 Jun 28. PubMed 21714971 ↗
  • Hoffmayer KS, Krainski F, Shah S, Hunter J, Alegre M, Hsu JC, Feld GK. Randomized controlled trial of Amigo(R) robotically controlled versus manually controlled ablation of the cavo-tricuspid isthmus using a contact force ablation catheter. J Interv Card Electrophysiol. 2018 Mar;51(2):125-132. doi: 10.1007/s10840-018-0319-1. Epub 2018 Feb 12. PubMed 29435790 ↗

Study documents

PDFs hosted by the registry, ClinicalTrials.gov.

Individual participant data

Plan to share: No

10

Timeline

Tracking since Sep 25, 2026
ElapsedEstimatedEstimated, not yet reachedSimilar studies: half by the dot; the band is the middle halfHalf of similar studies reached it by the dot; the band is the middle half, from a quarter to three quarters

Ran from Mar 2015 to primary completion in Oct 2017, 31 months.

Results were first posted in Jun 2019, 1 year 7 months after primary completion.

Of 800 non-industry interventional studies with no phase under Atrial Fibrillation, half reached primary completion within 40 months of starting (the median), counting those still running; a quarter within 21 and three quarters within 59. This study's 31 months is below that.

Counting every sponsor, half of 1,055 studies reached it within 33 months; a quarter within 18 and three quarters within 54.

How these figures are worked out, and which studies are left out of them.

Registered
Jun 3, 2015
First posted
Jun 9, 2015
StartActual
Mar 2015
Primary completionActual
Oct 30, 2017
CompletionActual
Mar 30, 2018
Results first posted
Jun 27, 2019
Last update
Jun 27, 2019
What these dates mean
Start.
When the first participant enrolled; while estimated, when the study expects to open to recruitment.
Primary completion.
When the last participant was examined or treated to collect data for the study's main question, its primary outcome. A study that stopped early gives the date its data collection stopped.
Completion.
When the last participant's last visit took place, for every outcome, secondary ones and side effects included: the end of the study. Often later than primary completion, sometimes the same day.
Actual and Est.
Actual means the registry says the date has happened. Est. (estimated) is a date the sponsor plans or expects. It can still move, and the sponsor is expected to change it to actual once it has passed.
No changes since tracking began. The registry record was last updated on Jun 27, 2019, before this site started recording changes on Sep 25, 2026. Its history is on ClinicalTrials.gov ↗
11

Registry details

Key details

Study ID
NCT02467179
Collaborators
Catheter Robotics, Inc.
Responsible party
Gregory Kent Feld (Professor of Medicine, University of California, San Diego) — Principal investigator
First posted
Jun 9, 2015
Start date
Mar 2015
Primary completion
Oct 30, 2017
Completion
Mar 30, 2018
Results posted
Jun 27, 2019
Last update
Jun 27, 2019

Study contacts

Gregory Feld, MD
principal investigator · UC San Diego

Oversight

Data monitoring committee
No
View the source record on ClinicalTrials.gov ↗

Not currently enrolling

This study is completed, as verified in Jun 2019. You cannot join it, but the record below documents what was studied.

Follow this study

Get an email when the registry record changes — status, dates, results — or when someone posts here.

Sign in to follow

Discussion

Questions and observations about this study, from anyone following it. Not medical advice, and not a channel to the study team — their contact details are on the registry record.

Sign in to join the discussion. Reading takes no account; posting does. You choose a display name, and a pseudonym is the default.

Nothing here yet. If you are running this trial, taking part in it, or weighing whether to, this is the place to say so.

Start the discussion