ClinicalTrials.gg
CompletedNCT01572922Updated Jun 11, 2019Results posted

Massive Iron Deposit Assessment

An interventional study of R2*-UTE and R2*-GRE in Iron Overload and Excessive Body Iron Burden, sponsored by St. Jude Children's Research Hospital. Completed at 1 site in United States. Per ClinicalTrials.gov, last updated 2019-06-11.

Sponsored by St. Jude Children's Research Hospital · Not applicable, Interventional, and Diagnostic

How we know

Help build ClinicalTrials.gg — short surveys, remote interviews or testing, in your language. Take part →

Phase
Not applicable
Study type
Interventional
Enrollment
142
Allocation
Not applicable
Sex
All
01

Where this study stands

Counted across the records on this site · 2026-11-23

Among 62 studies in Iron Overload with a site in United States — 1 open to participants now, 5 under way, none of them phase 3. Iron Overload · United States.

Enrollment
13th of 39
142 · median 51
Started
2012
with 4 others
No phase
7 of 62
none open now
Registered
38th of 62
by date
Lead sponsor
3 of 62
St. Jude Children's Research Hospital

Among the 62 studies in Iron Overload with a site in United States, this one is the 13th largest by enrollment of the 39 interventional ones that give a count, is one of 5 that started in 2012, is one of 7 with no phase, and was the 38th registered.

Iron Overload

156 studies on the registry are indexed under Iron Overload; 6 are open to participants now.

Browse Iron Overload studies →

Open to participants now

1 of the 62 studies in Iron Overload with a site in United States is open now. Recruiting first, the newest first:

A study can be open while its sites in United States have not opened yet or have stopped. Only those recruiting at a site in United States →

Who these studies take

Of the 4 Iron Overload studies recruiting now, 3 set no upper age limit and 1 stops at 75 or younger; 1 takes children under 18; none take healthy volunteers.

This study: all sexes · no healthy volunteers.

The full table on the hub →

This tab as a report to print or save as PDF → With an account.

Was this useful?
Get alerts for this landscapeDownload CSVNarrow it in search →With an account: a weekly mail of what changed among 62 studies in Iron Overload with a site in United States, or all of them as a file.
02

Study summary

Iron overload is a severe complication of multiple blood transfusions. As the body has no physiologic mechanism for clearing iron, repeated transfusions cause iron accumulation in organs and lead to iron toxicity. Accurate assessment of iron overload is paramount to quantify excessive iron accumulation and to monitor response to iron chelation therapy. Magnetic resonance imaging (MRI) methods have been used to noninvasively measure hepatic iron concentration (HIC). Although MRI-based measurements of transverse relaxation rates (R2 and R2*) accurately predict biopsy-proven HICs below 15 mg Fe/g, previous studies have shown that their precision is limited for HICs above 15 mg Fe/g and inaccurate above 25 mg Fe/g. Current R2* gradient-echo (GRE) MR techniques fail occasionally for very high iron overloads (HIC \~ 15-25 mg Fe/g) and always for massive iron overloads (HIC > 25 mg Fe/g) because R2* is so high that the MR signal decays before it can be measured accurately.

Overall accrual: 200 patients

Purpose: To determine if a new MRI (UTE) can measure the amount of iron in the liver of people with large amounts of iron and compare the results with the same patient's liver bx. Estimated patient accrual is 150. It is estimated that 41 of these patients will have clinical indication for liver biopsy.

Read the detailed description

The MIDAS study is a prospective and non-therapeutic study that will test a new MRI technique for the assessment of iron overload in the liver: the newly developed ultra short echo time (UTE), R2*-UTE. The R2*-UTE technique, developed by St. Jude investigators from the Department of Radiological Sciences, will be first tested in healthy volunteers for feasibility and implementation of the technique. The technique will then be tested in research participants, who will have both the R2*-GRE and the R2*-UTE techniques performed, in addition to a liver biopsy for liver iron quantitation if clinically indicated. Quantitation of liver tissue iron will be done at Mayo Clinic Laboratory in Rochester, Minnesota.

Primary Objective:

  • To test the association of hepatic iron content (HIC) measured with the newly developed 1.5T R2*-UTE technique and HIC quantified by liver biopsy in subjects with iron overload.

Secondary Objectives:

  • To explore the relationship between 1.5T R2*-UTE and 1.5T R2*-GRE measurements in subjects with iron overload.
  • To explore the relationship between 1.5T R2*-UTE measurements with iron studies (serum iron and transferrin saturation) in subjects with iron.
03

Conditions studied

  • Iron Overload
  • Excessive Body Iron Burden

Keywords

  • Sickle cell disease
  • Thalassemia
  • Hemochromatosis
  • Cancer
04

Who can participate

Ages eligible
Child (0–17), Adult (18–64), Older adult (65+)
Sexes eligible
All
Accepts healthy volunteers
No

Go through the criteria one by one — yes, no or not sure — and take the list to your doctor or the study team. Kept in this browser only.

Inclusion criteria

  • History of 12 or more lifetime erythrocyte transfusions, AND
  • Need for liver iron content assessment (by MRI or liver )

Exclusion criteria

Exclusion Criteria

  • Presence of certain MR-unsafe foreign material in the body, or other conditions that make the research participant ineligible for an MRI scan per St. Jude policies.
  • Any condition or chronic illness that in the opinion of the PIs makes participation on study ill-advised.
Terms in these criteria, in plain language(1)

Underlined terms in the criteria open these too. Explained by clinicaltrials.gg, not part of the registry record. The study team decides who can take part.

Biopsy and archival tissue

A biopsy takes a small piece of tissue to examine. “Archival tissue” is a sample already taken, for example at diagnosis, and kept by the hospital.

Whether a stored sample will do depends on when it was taken, how much there is and what the study needs. Ask whether the study accepts your stored sample or needs a new biopsy.

05

Study design

Phase
Not applicable
Primary purpose
Diagnostic
Allocation
Not applicable
Intervention model
Single group
Masking
None (open label)
Enrollment
142 participants (actual)

Study arms

  • Other
    Iron-overloaded

    Patients with iron overload or excessive body iron burden, a serious condition resulting from increased dietary gastro¬intestinal absorption, multiple erythrocyte transfusions, or both. Interventions: R2\*-UTE, R2\*-GRE, and if clinically indicated, liver biopsy.

    Device: R2*-UTE · Device: R2*-GRE · Procedure: Liver biopsy

Interventions

  • DeviceR2*-UTE

    Ultra short echo time (UTE) magnetic resonance imaging (MRI). Study participants will undergo an MRI examination of the liver on a 1.5T MRI and a 3T MRI scanner each. Because liver biopsy metal needle fragments could interfere with the MRI measurements, the MRI exams will always precede liver biopsy. Multi-echo GRE sequences will be used to acquire images with increasing TEs. Images of the liver will be obtained in transversal slice orientation through the center of the liver at the level of the origin of the main portal vein. At equivalent slice locations R2\*-UTE scans will be performed.

  • DeviceR2*-GRE

    Gradient-echo (GRE) magnetic resonance imaging (MRI). Study participants will undergo an MRI examination of the liver on a 1.5T MRI and a 3T MRI scanner each. Because liver biopsy metal needle fragments could interfere with the MRI measurements, the MRI exams will always precede liver biopsy. Multi-echo GRE sequences will be used to acquire images with increasing TEs. Images of the liver will be obtained in transversal slice orientation through the center of the liver at the level of the origin of the main portal vein. At equivalent slice locations R2\*-UTE scans will be performed.

  • ProcedureLiver biopsy

    Indications for liver biopsy include, but are not limited, to the need to quantify liver tissue iron and the need to obtain histopathological information of the liver tissue. Liver biopsies will only be performed if clinically indicated and will be done only once per patient. The technique to be used is coaxial percutaneous (transcapsular) technique; however, a coaxial transjugular technique may be performed in subjects with increased bleeding diathesis, since it is associated with less hemorrhagic risk. Healthy volunteers will not undergo liver biopsy.

06

What researchers measure

Primary outcomes

  1. Hepatic Iron Content in the Liver Using Liver Biopsy

    Hepatic iron content in the liver using liver biopsy

    Time frame: up to 30 days after MRI

  2. MRI-derived R2* Values Using 1.5T UTE Technique

    Hepatic iron content of the liver using MRI-derived 1.5T R2\*-UTE measurement, with results in Hz. R2\* is a measure obtained with MRI, i.e., MRI R2\*. It is measured in hertz (Hz). In lay terms, the MRI machine picks up a signal back from the tissue during the process of scanning the tissues. With every "picture taken", this signal is strong in the beginning and then wanes off. R2\* reflects how fast the signal wanes off. If there is too much iron in the tissue, the signal disappears faster, making the T2\* value low. T2\* is the reciprocal of R2\* (R2\*= 1/T2\*). So, if the signal drops fast, the T2\* is low and the R2\* is high. In this study, we are measuring the R2\* value. The higher the R2\*, the more iron in the liver tissue. We can compare the R2\* value with that of a liver biopsy to then use the R2\* value to tell us how much iron is in the liver without having to biopsy the liver.

    Time frame: Up to 30 days after MRI

Secondary outcomes

  1. MRI-derived R2* Using 1.5T GRE Technique

    MRI-derived R2\* Using 1.5T GRE Technique in Hz. R2\* is a measure obtained with MRI, i.e., MRI R2\*. It is measured in hertz (Hz). In lay terms, the MRI machine picks up a signal back from the tissue during the process of scanning the tissues. With every "picture taken", this signal is strong in the beginning and then wanes off. R2\* reflects how fast the signal wanes off. If there is too much iron in the tissue, the signal disappears faster, making the T2\* value low. T2\* is the reciprocal of R2\* (R2\*= 1/T2\*). So, if the signal drops fast, the T2\* is low and the R2\* is high. In this study, we are measuring the R2\* value. The higher the R2\*, the more iron in the liver tissue. We can compare the R2\* value with that of a liver biopsy to then use the R2\* value to tell us how much iron is in the liver without having to biopsy the liver.

    Time frame: Up to 30 days after MRI

  2. MRI Derived R2* Using 1.5T UTE Technique

    MRI-derived R2\* value using 1.5T R2\*-UTE in Hz. R2\* is a measure obtained with MRI, i.e., MRI R2\*. It is measured in hertz (Hz). In lay terms, the MRI machine picks up a signal back from the tissue during the process of scanning the tissues. With every "picture taken", this signal is strong in the beginning and then wanes off. R2\* reflects how fast the signal wanes off. If there is too much iron in the tissue, the signal disappears faster, making the T2\* value low. T2\* is the reciprocal of R2\* (R2\*= 1/T2\*). So, if the signal drops fast, the T2\* is low and the R2\* is high. In this study, we are measuring the R2\* value. The higher the R2\*, the more iron in the liver tissue. We can compare the R2\* value with that of a liver biopsy to then use the R2\* value to tell us how much iron is in the liver without having to biopsy the liver.

    Time frame: up to 30 days after MRI

  3. R2* Using 1.5T UTE Technique for Patients With Serum Iron and Transferrin Saturation Measurements

    MRI-derived R2\* value using 1.5T R2\*-UTE in Hz for patients who have had serum iron and transferrin saturation measurements. R2\* is a measure obtained with MRI, i.e., MRI R2\*. It is measured in hertz (Hz). In lay terms, the MRI machine picks up a signal back from the tissue during the process of scanning the tissues. With every "picture taken", this signal is strong in the beginning and then wanes off. R2\* reflects how fast the signal wanes off. If there is too much iron in the tissue, the signal disappears faster, making the T2\* value low. T2\* is the reciprocal of R2\* (R2\*= 1/T2\*). So, if the signal drops fast, the T2\* is low and the R2\* is high. In this study, we are measuring the R2\* value. The higher the R2\*, the more iron in the liver tissue. We can compare the R2\* value with that of a liver biopsy to then use the R2\* value to tell us how much iron is in the liver without having to biopsy the liver.

    Time frame: Up to 30 days after MRI

  4. Serum Iron Measurements Compared With 1.5T R2* UTE

    Serum iron measurements from eligible patients had 1.5T R2\*-UTE and serum iron and transferrin saturation measurements.

    Time frame: Up to 30 days after MRI

  5. Transferrin Saturation Measurements

    Iron Transferrin Saturation in % measurements Transferrin Saturation measurements from eligible patients had 1.5T R2\*-UTE and serum iron and transferrin saturation measurements.

    Time frame: Up to 30 days after MRI

07

Results

Posted May 21, 2019

Participant flow

Patients within the St. Jude Network (St. Jude Children's Research Hospital, St. Jude Domestic Affiliates, and the adult Hematology and Oncology program at the University of Tennessee Health Sciences Center) who have history of 12 or more lifetime erythrocyte transfusions, and need for liver iron content assessment.

Participant flow — Overall Study
MilestoneArm 1
Started142
Completed139
Not completed3
Withdrew: Adverse event1
Withdrew: Protocol violation1
Withdrew: Death1

Outcome measures

PrimaryHepatic Iron Content in the Liver Using Liver Biopsy

Hepatic iron content in the liver using liver biopsy

Time frame:
up to 30 days after MRI
Reported as:
Median · mcg
Hepatic Iron Content in the Liver Using Liver Biopsy
mcgIron-overloaded Patients
Hepatic Iron Content in the Liver Using Liver Biopsy19.8 (0.1 to 45.0)
PrimaryMRI-derived R2* Values Using 1.5T UTE Technique

Hepatic iron content of the liver using MRI-derived 1.5T R2\*-UTE measurement, with results in Hz. R2\* is a measure obtained with MRI, i.e., MRI R2\*. It is measured in hertz (Hz). In lay terms, the MRI machine picks up a signal back from the tissue during the process of scanning the tissues. With every "picture taken", this signal is strong in the beginning and then wanes off. R2\* reflects how fast the signal wanes off. If there is too much iron in the tissue, the signal disappears faster, making the T2\* value low. T2\* is the reciprocal of R2\* (R2\*= 1/T2\*). So, if the signal drops fast, the T2\* is low and the R2\* is high. In this study, we are measuring the R2\* value. The higher the R2\*, the more iron in the liver tissue. We can compare the R2\* value with that of a liver biopsy to then use the R2\* value to tell us how much iron is in the liver without having to biopsy the liver.

Time frame:
Up to 30 days after MRI
Reported as:
Median · Hz
MRI-derived R2* Values Using 1.5T UTE Technique
HzIron-overloaded Patients
MRI-derived R2* Values Using 1.5T UTE Technique864.4 (45.4 to 2245.5)
SecondaryMRI-derived R2* Using 1.5T GRE Technique

MRI-derived R2\* Using 1.5T GRE Technique in Hz. R2\* is a measure obtained with MRI, i.e., MRI R2\*. It is measured in hertz (Hz). In lay terms, the MRI machine picks up a signal back from the tissue during the process of scanning the tissues. With every "picture taken", this signal is strong in the beginning and then wanes off. R2\* reflects how fast the signal wanes off. If there is too much iron in the tissue, the signal disappears faster, making the T2\* value low. T2\* is the reciprocal of R2\* (R2\*= 1/T2\*). So, if the signal drops fast, the T2\* is low and the R2\* is high. In this study, we are measuring the R2\* value. The higher the R2\*, the more iron in the liver tissue. We can compare the R2\* value with that of a liver biopsy to then use the R2\* value to tell us how much iron is in the liver without having to biopsy the liver.

Time frame:
Up to 30 days after MRI
Reported as:
Median · Hz
MRI-derived R2* Using 1.5T GRE Technique
HzIron-overloaded Patients
MRI-derived R2* Using 1.5T GRE Technique333.8 (33.6 to 2726.3)
SecondaryMRI Derived R2* Using 1.5T UTE Technique

MRI-derived R2\* value using 1.5T R2\*-UTE in Hz. R2\* is a measure obtained with MRI, i.e., MRI R2\*. It is measured in hertz (Hz). In lay terms, the MRI machine picks up a signal back from the tissue during the process of scanning the tissues. With every "picture taken", this signal is strong in the beginning and then wanes off. R2\* reflects how fast the signal wanes off. If there is too much iron in the tissue, the signal disappears faster, making the T2\* value low. T2\* is the reciprocal of R2\* (R2\*= 1/T2\*). So, if the signal drops fast, the T2\* is low and the R2\* is high. In this study, we are measuring the R2\* value. The higher the R2\*, the more iron in the liver tissue. We can compare the R2\* value with that of a liver biopsy to then use the R2\* value to tell us how much iron is in the liver without having to biopsy the liver.

Time frame:
up to 30 days after MRI
Reported as:
Median · HZ
MRI Derived R2* Using 1.5T UTE Technique
HZIron-overloaded Patients
MRI Derived R2* Using 1.5T UTE Technique319.2 (45.2 to 2245.5)
SecondaryR2* Using 1.5T UTE Technique for Patients With Serum Iron and Transferrin Saturation Measurements

MRI-derived R2\* value using 1.5T R2\*-UTE in Hz for patients who have had serum iron and transferrin saturation measurements. R2\* is a measure obtained with MRI, i.e., MRI R2\*. It is measured in hertz (Hz). In lay terms, the MRI machine picks up a signal back from the tissue during the process of scanning the tissues. With every "picture taken", this signal is strong in the beginning and then wanes off. R2\* reflects how fast the signal wanes off. If there is too much iron in the tissue, the signal disappears faster, making the T2\* value low. T2\* is the reciprocal of R2\* (R2\*= 1/T2\*). So, if the signal drops fast, the T2\* is low and the R2\* is high. In this study, we are measuring the R2\* value. The higher the R2\*, the more iron in the liver tissue. We can compare the R2\* value with that of a liver biopsy to then use the R2\* value to tell us how much iron is in the liver without having to biopsy the liver.

Time frame:
Up to 30 days after MRI
Reported as:
Median · Hz
R2* Using 1.5T UTE Technique for Patients With Serum Iron and Transferrin Saturation Measurements
HzIron-overloaded Patients
R2* Using 1.5T UTE Technique for Patients With Serum Iron and Transferrin Saturation Measurements340.8 (45.2 to 2245.5)
SecondarySerum Iron Measurements Compared With 1.5T R2* UTE

Serum iron measurements from eligible patients had 1.5T R2\*-UTE and serum iron and transferrin saturation measurements.

Time frame:
Up to 30 days after MRI
Reported as:
Median · ug/dL
Serum Iron Measurements Compared With 1.5T R2* UTE
ug/dLSerum Iron Measurements
Serum Iron Measurements Compared With 1.5T R2* UTE156.5 (35 to 311)
SecondaryTransferrin Saturation Measurements

Iron Transferrin Saturation in % measurements Transferrin Saturation measurements from eligible patients had 1.5T R2\*-UTE and serum iron and transferrin saturation measurements.

Time frame:
Up to 30 days after MRI
Reported as:
Median · percentage
Transferrin Saturation Measurements
percentageIron-overloaded Patients
Transferrin Saturation Measurements71 (12 to 157)

Adverse events

Collected over Time frame for adverse event reporting is 10 days following the last study procedure for eligible patients.. Non-serious events are listed at a 0% frequency threshold.

Adverse event summary by group
GroupDeathsSeriousOther
Iron-overloaded Patients1/142 (0.7%)1/142 (0.7%)2/142 (1.4%)
Most frequent serious events
Most frequent serious events
EventIron-overloaded Patients
Infections and infestationsGastrointestinal disorders1/142
Most frequent other events
Most frequent other events
EventIron-overloaded Patients
AnxietyPsychiatric disorders1/142
abdominal painGastrointestinal disorders1/142

Baseline characteristics

Age, Categorical
Age, Categorical(Participants)Arm 1
<=18 years85
Between 18 and 65 years57
>=65 years0
Age, Continuous
Age, Continuous(years)Arm 1
Median15.9 (1.5 to 53.6)
Sex: Female, Male
Sex: Female, Male(Participants)Arm 1
Female79
Male63
Ethnicity (NIH/OMB)
Ethnicity (NIH/OMB)(Participants)Arm 1
Hispanic or Latino8
Not Hispanic or Latino131
Unknown or Not Reported3
Race/Ethnicity, Customized
Race/Ethnicity, Customized(Participants)Arm 1
Asian10
Black or African American85
White40
More than one race1
Unknown or Not Reported6
Region of Enrollment
Region of Enrollment(Participants)Arm 1
United States142
08

Study locations

1 site
  • St. Jude Children's Research Hospital
    Memphis, Tennessee 38105, United States
09

References and documents

Study documents

PDFs hosted by the registry, ClinicalTrials.gov.

10

Timeline

Tracking since Sep 25, 2026
ElapsedEstimatedEstimated, not yet reached

Ran from Jun 2012 to primary completion in Feb 2018, 68 months.

Results were first posted in May 2019, 1 year 2 months after primary completion.

How these figures are worked out, and which studies are left out of them.

Registered
Apr 3, 2012
First posted
Apr 6, 2012
StartActual
Jun 11, 2012
Primary completionActual
Feb 28, 2018
CompletionActual
Feb 28, 2018
Results first posted
May 21, 2019
Last update
Jun 11, 2019
What these dates mean
Start.
When the first participant enrolled; while estimated, when the study expects to open to recruitment.
Primary completion.
When the last participant was examined or treated to collect data for the study's main question, its primary outcome. A study that stopped early gives the date its data collection stopped.
Completion.
When the last participant's last visit took place, for every outcome, secondary ones and side effects included: the end of the study. Often later than primary completion, sometimes the same day.
Actual and Est.
Actual means the registry says the date has happened. Est. (estimated) is a date the sponsor plans or expects. It can still move, and the sponsor is expected to change it to actual once it has passed.
No changes since tracking began. The registry record was last updated on Jun 11, 2019, before this site started recording changes on Sep 25, 2026. Its history is on ClinicalTrials.gov ↗
11

Registry details

Key details

Study ID
NCT01572922
Responsible party
Sponsor
First posted
Apr 6, 2012
Start date
Jun 11, 2012
Primary completion
Feb 28, 2018
Completion
Feb 28, 2018
Results posted
May 21, 2019
Last update
Jun 11, 2019

Study contacts

Jane Hankins, MD, MS
principal investigator · St. Jude Children's Research Hospital

Oversight

Data monitoring committee
No
FDA-regulated drug
No
FDA-regulated device
Yes
View the source record on ClinicalTrials.gov ↗

Not currently enrolling

This study is completed, as verified in Apr 2019. You cannot join it, but the record below documents what was studied.

Follow this study

Get an email when the registry record changes — status, dates, results — or when someone posts here.

Sign in to follow

Discussion

Questions and observations about this study, from anyone following it. Not medical advice, and not a channel to the study team — their contact details are on the registry record.

Sign in to join the discussion. Reading takes no account; posting does. You choose a display name, and a pseudonym is the default.

Nothing here yet. If you are running this trial, taking part in it, or weighing whether to, this is the place to say so.

Start the discussion