An interventional study of Radial Radiolucent Ring Retractor and Augmented Reality Glasses in Distal Radius Fracture, sponsored by The University of Hong Kong. Not yet recruiting at 1 site in Hong Kong. Open to participants aged 18 Years to 85 Years. Per ClinicalTrials.gov, last updated 2026-11-17.
Sponsored by The University of Hong Kong · Not applicable, Interventional, and Treatment
Help build ClinicalTrials.gg — short surveys, remote interviews or testing, in your language. Take part →
The surgical management of distal radius fractures via open reduction and internal fixation (ORIF) remains the gold standard for restoring wrist function. However, the procedure is traditionally characterized by repetitive workflow interruptions of the removal of metallic retractors to avoid radiological artifacts and the ergonomic strain of the "head-turn" required to view distant fluoroscopy monitors.
The Radius Radiolucent Ring Retractor (RRRR) is a single-use, 3D-printed nylon surgical device designed for hands-free retraction in arm and wrist surgeries. This device was developed at the University of Hong Kong and invention is held by HKU Versitech Limited.
This study aims to definitively evaluate the gadget-optimized distal radius fixation surgery with the RRRR and head-mounted Augmented Reality glasses display to optimize the surgical workflow. This trial will evaluate whether this system provides a more efficient alternative to conventional monitor-based fluoroscopy in modern orthopedic practice.
330 studies on the registry are indexed under Wrist Fractures; 72 are open to participants now.
This study's planned enrollment of 94 is above the median of 63 across 265 interventional studies indexed under Wrist Fractures.
Browse Wrist Fractures studies →The University of Hong Kong is the lead sponsor of 1,295 studies on the registry; 351 are open to participants now.
Of its 9 completed or terminated interventional studies of FDA-regulated products, 0 (0%) have results posted.
Counted across the registry records on this site, refreshed daily.
Go through the criteria one by one — yes, no or not sure — and take the list to your doctor or the study team. Kept in this browser only.
Exclusion Criteria:
The surgery will be completed with the combination of Radius Radiolucent Ring Retractor (RRRR) and Augmented Reality Glasses. The RRRR is a 3D-printed surgical tool designed for hands-free retraction in arm and wrist surgeries. The Augmented Reality Glasses for surgeons designed specifically for surgeons can display real-time X-ray images directly in the doctor's field of vision, allowing the doctor to focus on the wrist throughout the procedure without having to turn their head to look at the X-ray screen.
Device: Radial Radiolucent Ring Retractor · Device: Augmented Reality Glasses
Traditional method with metal retractors and standard X-ray monitor.
Device: Metal Retractor · Device: Standard X-ray monitor
The Radius Radiolucent Ring Retractor (RRRR) is a single-use, 3D-printed nylon surgical device designed for hands-free retraction in arm and wrist surgeries.
Augmented Reality of C-Arm intraoperative fluoroscopic imaging integration with a head mount-display (HMD).
Manual traditional metal retractor used by surgeons and assistants.
Standard X-ray monitor that displays fluoroscopy images during the operation.
Total Fluoroscopy Time
The total duration, measured in minutes or seconds, that the X-ray beam is actively turned on during a fluoroscopic procedure during the operation.
Time frame: Intra-operative
Functional Assessment measured by QuickDASH Score
The QuickDASH score is a validated, internationally recognized tool to assess functional outcomes of patients of the upper arm, especially in long term recovery assessments. The survey will assess the control group against intervention group in return to daily activities, assessment of overall upper limb function, symptoms, and quality of life.
Time frame: At post-op, 3 weeks, 6 weeks , 3 months and 6 months
Rating of placement of implant using 25 point Surgeon-Reported Outcome Measures
The qualitative assessment of 1 to 5 of the placement of implant rated by the surgeon.
Time frame: Immediately after operation
Rating of ergonomics and visualisation of plate position using 25 point Surgeon-Reported Outcome Measures
The qualitative assessment of 1 to 5 of the ergonomics and visualisation of plate position rated by the surgeon.
Time frame: Immediately after operation
Rating of retraction during fluoroscopy using 25 point Surgeon-Reported Outcome Measures
The qualitative assessment of 1 to 5 of the retraction during fluoroscopy rated by the surgeon.
Time frame: Immediately after operation
Rating of fracture reduction using 25 point Surgeon-Reported Outcome Measures
The qualitative assessment of 1 to 5 of the quality of fracture reduction rated by the surgeon.
Time frame: Immediately after operation
Rating of overall assistants' efforts using 25 point Surgeon-Reported Outcome Measures
The qualitative assessment of 1 to 5 of the quality of overall assistants' efforts rated by the surgeon.
Time frame: Immediately after operation
Number of surgical assistants
The maximum number of surgical assistants required for retraction tasks at any single point during the surgery.
Time frame: Intra-operative
Number of times retractors were removed and replaced
The number of times the whole RRRR or the metal retractor is lifted out of the incision site, then putting it back count as 1.
Time frame: Intra-operative
Number of times the retractor was loosened from the surgical site
The number of times the traditional retractor or RRRR is not adequately retracting the surgical wound and providing a clear view of the fracture site,
Time frame: Intra-operative
Number of readjustments for fracture reduction
The number of times that a fracture reduction is changed during the operation.
Time frame: Intra-operative
Number of attempts for repositioning Kirschner wire
The numbers of times the Kirschner wire is removed from the incision site and then putting it back count as 1.
Time frame: Intra-operative
Maximum number of Kirschner wire used to maintain positioning and/or reduction
The maximum number of Kirschner wires at any time point that are used to maintain implant positioning and/or fracture reduction.
Time frame: Intra-operative
Number of repositioning of plates
The number of times the implant plate is moved and repositioned is recorded as 1.
Time frame: Intra-operative
Number of repositioning of screws
The number of times the screw is removed from the incision site and repositioned is recorded as 1.
Time frame: Intra-operative
Total number of screws used in the operation
The total number of screws that are used in the operation, including those that are implanted or wasted.
Time frame: Intra-operative
Number of head turns to assess x-ray images
The number of times the primary surgeon looks at the fluoroscopy monitor during fracture reduction.
Time frame: Intra-operative
Number of times the eyepiece focus is lost
The number of times the AR HMD eyepiece is out of focus is recorded as 1.
Time frame: Intra-operative
Duration of surgery
Defined from the time difference of the incision start time and the completion time of final suturing.
Time frame: Intra-operative
Incision Length in mm
Defined as the length in millimeters of the incision cut in the surgery.
Time frame: Intra-operative
Radial Inclination in degrees
Measurement of the coronal-plane slope of the distal radius articular surface, measured in pre-operative and post-operative wrist x-ray.
Time frame: At post-op, 3 weeks, 6 weeks , 3 months and 6 months
Radial Height in millimeters
Measurement of the axial distance between perpendicular lines at the radial styloid and ulnar border, quantifying fracture-induced radial shortening, measured in pre-operative and post-operative wrist x-ray.
Time frame: At post-op, 3 weeks, 6 weeks , 3 months and 6 months
Volar / Dorsal Angulation in degrees
Measurement of the tilt of the distal articular surface relative to the shaft, measured in pre-operative and post-operative wrist x-ray.
Time frame: At post-op, 3 weeks, 6 weeks , 3 months and 6 months
Articular Step-off in millimeters
Measurement of the vertical incongruity along the subchondral surface, measured in pre-operative and post-operative wrist x-ray.
Time frame: At post-op, 3 weeks, 6 weeks , 3 months and 6 months
Plan to share: Yes — Anonymized dataset to be included as supplementary data in final publication
Supporting information: Study protocol, Statistical analysis plan, Informed consent form, Clinical study report
Time frame: Within 1 year of study completion
Access criteria: Additional information available upon reasonable request of principal investigator
Start is estimated for Dec 2026; primary completion for Mar 2028, 15 months later.
Of 126 non-industry interventional studies with no phase under Wrist Fractures, half reached primary completion within 25 months of starting (the median), counting those still running; a quarter within 16 and three quarters within 50. This study's planned 15 months is below that.
Counting every sponsor, half of 127 studies reached it within 25 months; a quarter within 16 and three quarters within 50.
How these figures are worked out, and which studies are left out of them.
From the registry record's own update history. This site started tracking changes on Sep 25, 2026; for anything earlier, see the record history on ClinicalTrials.gov ↗
This study is not yet recruiting, as verified in Oct 2026. You cannot join it, but the record below documents what was studied.
Get an email when the registry record changes — status, dates, results — or when someone posts here.
Sign in to followQuestions and observations about this study, from anyone following it. Not medical advice, and not a channel to the study team — their contact details are on the registry record.
Sign in to join the discussion. Reading takes no account; posting does. You choose a display name, and a pseudonym is the default.
Nothing here yet. If you are running this trial, taking part in it, or weighing whether to, this is the place to say so.