An observational study in Cataract, sponsored by Clínica de Oftalmología de Cali S.A. Completed at 1 site in Colombia. Open to participants aged 40 Years and older, including healthy volunteers. Per ClinicalTrials.gov, last updated 2026-11-16.
Sponsored by Clínica de Oftalmología de Cali S.A · Observational
Help build ClinicalTrials.gg — short surveys, remote interviews or testing, in your language. Take part →
This single-center, observational, analytical, ambispective study aims to develop and internally validate a clinical decision support system for cataract surgery planning using swept-source optical coherence tomography (SS-OCT) integrated into the ARGOS optical biometer.
The study will evaluate the ability of preoperative crystalline lens tomographic patterns (Types I-III) to predict surgical complexity and the surgical approach required during cataract extraction. Additionally, it will assess whether SS-OCT-derived information provides incremental predictive value beyond conventional clinical assessment using the Lens Opacities Classification System III (LOCS III).
Clinical, biometric, and surgical data will be analyzed to determine the predictive performance, reproducibility, and technical feasibility of the proposed classification system. The ultimate goal is to establish an objective, noninvasive, and reproducible tool to support personalized surgical planning and preoperative risk stratification in cataract surgery.
Background and Rationale
Cataract remains a leading cause of visual impairment and preventable blindness worldwide. Although advances in surgical techniques and technology have improved cataract surgery outcomes, predicting surgical complexity and selecting the most appropriate surgical approach remain important clinical challenges. Currently, preoperative assessment relies primarily on clinical examination and subjective grading systems, such as the Lens Opacities Classification System III (LOCS III), which may exhibit interobserver variability.
Swept-source optical coherence tomography (SS-OCT), integrated into optical biometers such as ARGOS (Alcon Laboratories, Inc.), provides noninvasive, high-resolution images of the crystalline lens and biometric measurements. These images may reveal morphological characteristics associated with lens opacity, nuclear density, and surgical complexity.
This study proposes the development and internal validation of a clinical decision support system based on the identification of specific crystalline lens tomographic patterns to improve preoperative risk stratification and support cataract surgery planning.
Study Design and Population
This is a single-center, observational, analytical, ambispective study conducted at Clínica de Oftalmología de Cali, Colombia. The study will include patients older than 40 years undergoing crystalline lens extraction who have undergone preoperative optical biometry using the ARGOS device, including SS-OCT imaging of the crystalline lens.
The ambispective design will incorporate retrospectively identified surgical cases and prospectively included patients. Surgical management will follow routine clinical practice, without experimental treatment assignment or modification of the surgical technique by the investigators.
Patients undergoing combined cataract surgery with glaucoma, corneal, or retinal procedures, those with a history of significant ocular trauma affecting anterior segment anatomy, and patients with ocular conditions preventing reliable tomographic image acquisition will be excluded.
A reference group of patients with clear crystalline lenses who underwent ARGOS biometry for indications other than cataract will be used exclusively to characterize the Type I tomographic pattern. These individuals will not be included in the statistical analysis.
Preoperative Assessment and Tomographic Classification
Preoperative evaluation will include demographic characteristics, visual acuity, LOCS III cataract grading, relevant ocular comorbidities, and biometric parameters obtained using ARGOS.
Crystalline lens SS-OCT images will be classified according to three predefined tomographic patterns (Types I, II, and III), based on lens reflectivity, intralenticular signal distribution, and the morphological characteristics of the anterior and posterior lens peaks.
Images will be independently assessed by trained observers blinded to the surgical technique and intraoperative outcomes. Disagreements will be resolved through consensus or third-observer adjudication. Interobserver and intraobserver reproducibility will be evaluated.
Study Outcomes
The primary outcome will be the need for a complex surgical approach during cataract extraction, defined using prespecified objective criteria derived from surgical records and, when available, surgical recordings.
Secondary outcomes will include the specific surgical technique performed, conversion from the initially planned approach, phacoemulsification energy parameters, intraoperative complications, and technical feasibility of SS-OCT image acquisition and interpretation.
Statistical Analysis and Internal Validation
The predictive performance of the proposed tomographic classification will be assessed using sensitivity, specificity, positive and negative predictive values, likelihood ratios, and overall classification accuracy, with 95% confidence intervals.
Multivariable logistic regression will be used to evaluate the association between SS-OCT patterns and surgical complexity. A conventional clinical prediction model based on LOCS III and prespecified clinical variables will be compared with an expanded model incorporating the SS-OCT tomographic classification.
Model discrimination will be evaluated using the area under the receiver operating characteristic curve (AUC-ROC), while calibration will be assessed by comparing predicted and observed outcomes. Internal validation will be performed using bootstrap resampling.
Expected Clinical Relevance
The study seeks to determine whether SS-OCT-derived crystalline lens patterns can provide clinically useful information beyond conventional cataract grading. If validated, this classification could support more objective preoperative assessment, improve identification of surgically complex cases, and facilitate individualized cataract surgery planning using information already available from routine optical biometry.
The proposed system is intended to complement, rather than replace, clinical judgment. Further external validation will be required before its implementation in routine clinical practice.
1,632 studies on the registry are indexed under Cataract; 235 are open to participants now.
This study's enrollment of 499 is above the median of 90 across 476 observational studies indexed under Cataract.
Browse Cataract studies →Clínica de Oftalmología de Cali S.A is the lead sponsor of 2 studies on the registry; none are open to participants now.
Counted across the registry records on this site, refreshed daily.
For the establishment of the reference group with clear crystalline lenses, patients who underwent optical biometry using the ARGOS device for indications other than cataract, such as myopia monitoring, will be included to characterize the Type I pattern. These patients were not included in the statistical analysis of the study.
The study population will consist of patients older than 40 years with an indication for crystalline lens extraction and preoperative biometry performed using ARGOS, including acquisition of SS-OCT images of the crystalline lens. Patients in whom both the preoperative tomographic pattern and the surgical outcome can be adequately determined will be eligible.
Go through the criteria one by one — yes, no or not sure — and take the list to your doctor or the study team. Kept in this browser only.
Exclusion Criteria:
Patients older than 40 years undergoing cataract surgery with preoperative swept-source optical coherence tomography (SS-OCT) imaging obtained using the ARGOS biometer. Lenticular tomographic patterns will be classified and evaluated for their ability to predict surgical complexity and the surgical approach required.
Diagnostic Test: Swept-Source Optical Coherence Tomography (SS-OCT) Using ARGOS Biometer
Preoperative assessment of crystalline lens tomographic patterns using swept-source optical coherence tomography (SS-OCT) integrated into the ARGOS optical biometer. Images will be classified according to predefined lenticular patterns (Types I-III) to evaluate their predictive value for surgical complexity and surgical approach during cataract extraction.
Also known as: ARGOS Biometer, ARGOS Swept-Source OCT, SS-OCT Optical Biometry
Predictive Performance of SS-OCT Lenticular Patterns for Surgical Complexity in Cataract Surgery
Assessment of the ability of preoperative crystalline lens tomographic patterns (Types I-III), obtained using swept-source optical coherence tomography (SS-OCT) with the ARGOS biometer, to predict the need for a complex surgical approach during cataract extraction. Surgical complexity will be classified as conventional or complex according to predefined objective criteria derived from operative records. Predictive performance will be evaluated using sensitivity, specificity, positive and negative predictive values, likelihood ratios, and overall classification accuracy, with 95% confidence intervals.
Time frame: 6 months
Incremental Predictive Value of SS-OCT Compared With LOCS III
Evaluation of the additional predictive value of SS-OCT lenticular patterns beyond conventional clinical assessment using LOCS III. Predictive models will be compared in terms of discrimination, measured by the area under the receiver operating characteristic curve (AUC-ROC), and calibration.
Time frame: 6 months
Distribution of Surgical Techniques Across SS-OCT Lenticular Pattern Categories
To determine the percentage of eyes undergoing each surgical technique within the preoperative lenticular pattern categories (I, II, and III), as classified using swept-source optical coherence tomography (SS-OCT) images obtained with the ARGOS optical biometer. Surgical techniques will be identified from operative records and categorized as phacoemulsification (divide and conquer, stop and chop, vertical chop, or horizontal chop), extracapsular cataract extraction, or manual small-incision cataract surgery (MSICS). The frequency distribution of surgical techniques will be compared across SS-OCT lenticular pattern categories using appropriate categorical statistical methods.
Time frame: 6 months
Cumulative Dissipated Energy During Phacoemulsification Across SS-OCT Lenticular Pattern Categories
To quantify cumulative dissipated energy (CDE) during cataract surgery performed using phacoemulsification and describe its distribution across preoperative SS-OCT lenticular pattern categories (I, II, and III). CDE will be obtained from the phacoemulsification system records and expressed in the units reported by the device. Differences in CDE across lenticular pattern categories will be evaluated using statistical methods appropriate to the observed distribution of the data.
Time frame: 6 months
Interobserver and Intraobserver Reproducibility of SS-OCT Lenticular Pattern Classification
Assessment of interobserver and intraobserver agreement in the classification of SS-OCT lenticular patterns (Types I-III), using percentage agreement and Cohen's kappa coefficient with 95% confidence intervals.
Time frame: 6 months
Incidence of Intraoperative Complications
Assessment of the occurrence of intraoperative complications during cataract surgery and their association with preoperative SS-OCT lenticular patterns. Complication frequencies will be reported according to tomographic pattern classification.
Time frame: 6 months
PDFs hosted by the registry, ClinicalTrials.gov.
Plan to share: Yes
Supporting information: Study protocol, Statistical analysis plan, Clinical study report
Time frame: In 6 months
Access criteria: Restricted access by request
Data sharing details ↗ · www.visionsana.com
Ran from May 2026 to primary completion in Oct 2026, 5 months.
Of 168 non-industry observational studies under Cataract, half reached primary completion within 19 months of starting (the median), counting those still running; a quarter within 9 and three quarters within 30. This study's 5 months is below that.
Counting every sponsor, half of 235 studies reached it within 16 months; a quarter within 9 and three quarters within 30.
How these figures are worked out, and which studies are left out of them.
From the registry record's own update history. This site started tracking changes on Sep 25, 2026; for anything earlier, see the record history on ClinicalTrials.gov ↗
This study is completed, as verified in Nov 2026. You cannot join it, but the record below documents what was studied.
Get an email when the registry record changes — status, dates, results — or when someone posts here.
Sign in to followQuestions and observations about this study, from anyone following it. Not medical advice, and not a channel to the study team — their contact details are on the registry record.
Sign in to join the discussion. Reading takes no account; posting does. You choose a display name, and a pseudonym is the default.
Nothing here yet. If you are running this trial, taking part in it, or weighing whether to, this is the place to say so.
Clínica de Oftalmología de Cali S.A