An observational study in Septic Shock, sponsored by Assistance Publique - Hôpitaux de Paris. Not yet recruiting. Open to participants aged 18 Years and older. Per ClinicalTrials.gov, last updated 2026-07-17.
Sponsored by Assistance Publique - Hôpitaux de Paris · Observational
Help build ClinicalTrials.gg — short surveys, remote interviews or testing, in your language. Take part →
Among 30 studies in Shock, Septic by Assistance Publique - Hôpitaux de Paris — 15 open to participants now, 16 under way, 3 of them phase 3. Shock, Septic · Assistance Publique - Hôpitaux de Paris.
Among the 30 studies in Shock, Septic by Assistance Publique - Hôpitaux de Paris, this one is the 11th largest by planned enrollment of the 13 observational ones that give a count, is one of 6 that started in 2026, is one of 13 observational ones, reaches primary completion later than 12 of the 15 other live ones, and was the 29th registered.
1,084 studies on the registry are indexed under Shock, Septic; 236 are open to participants now.
Browse Shock, Septic studies →15 of the 30 studies in Shock, Septic by Assistance Publique - Hôpitaux de Paris are open now, in 1 country. Recruiting first, the newest first:
Assistance Publique - Hôpitaux de Paris · Sites in France
Ages 18+
Assistance Publique - Hôpitaux de Paris · Sites in France
Ages 6+
Assistance Publique - Hôpitaux de Paris · Sites in France
Ages 18+
Assistance Publique - Hôpitaux de Paris · Sites in France
Ages 18+
Assistance Publique - Hôpitaux de Paris · Sites in France
Ages 18+
By country, each count listing its studies:
Of the 137 Shock, Septic studies recruiting now, 103 (75%) set no upper age limit and 18 (13%) stop at 75 or younger; 11 take children under 18; 14 take healthy volunteers.
This study: 18 Years and older · all sexes · no healthy volunteers.
The full table on the hub →This tab as a report to print or save as PDF → With an account.
30 studies; the count open now beside each. This study's row is marked.
First in 2007; this study’s year is marked. 6 started in 2026.
By drug class, each counting the studies that test any of its medicines:
This study's planned enrollment of 30 is below the median of 108 across 408 observational studies indexed under Shock, Septic.
Median enrollment 210 across the 17 interventional studies, 110 across the 13 observational. Of the 11 that completed or were terminated, 0 (0%) have results posted.
This tab as a report to print or save as PDF → With an account.
Assistance Publique - Hôpitaux de Paris is the lead sponsor of 3,600 studies on the registry; 1,039 are open to participants now.
1 of the studies in Shock, Septic by Assistance Publique - Hôpitaux de Paris that are under way reach primary completion within a year, 1 of them phase 3. Phase 3 first, then by date:
| Study | Primary completion |
|---|---|
| NCT06851078Phase 3Assistance Publique - Hôpitaux de ParisEvaluation of Early Administration of Levetiracetam in the Prevention and Treatment Encephalopathy in Septic Shock: Randomized, Double-blind, Placebo-controlled Trial | 2027-06-15 |
Add it to your calendar (.ics) → With an account.
Among the 30 studies in Shock, Septic by Assistance Publique - Hôpitaux de Paris, from their registry updates:
This tab as a report to print or save as PDF → With an account.
The pulmonary artery catheter (Swan-Ganz) is a standard tool in intensive care for measuring and monitoring the pulmonary artery occlusion pressure (PAOP). The Swan-Ganz IQ™ model also allows automatic measurement to reduce the risk of error (Smart Wedge). However, the concordance between this automatic method and the manual method remains poorly studied in real clinical conditions and may vary depending on certain clinical situations. This study therefore aims to compare the PAOP automatically measured (Smart Wedge) with the manual PAOP measurement at bedside based on data collected in clinical practice.
The pulmonary artery catheter (or Swan-Ganz catheter) is a standard tool for measuring and monitoring PAOP in intensive care. It measures PAOP manually, which is considered the gold standard method. The Swan-Ganz IQ™ model also offers automatic measurement of PAOP during inflation of the balloon in the pulmonary artery (Smart Wedge). The ability to automatically measure PAOP would decrease the risk of error. However, the concordance between manual PAOP (reference method) and automatic PAOP (Smart Wedge) remains poorly evaluated by independent data in real clinical conditions. Furthermore, this agreement may vary depending on the clinical situation. In this context, this study aims to compare the manual PAOP measurement and the automatic PAOP measurement (Smart Wedge) based on data collected in the clinical setting.
Patients hospitalized in medical ICU (of Bicêtre and Angers) with pulmonary arterial catheter (PAC) place as part of routine clinical care.
Go through the criteria one by one — yes, no or not sure — and take the list to your doctor or the study team. Kept in this browser only.
Exclusion Criteria:
Swan-Ganz IQ™ is a device that provides continuous measurement of cardiac index by analyzing the right ventricular pressure wave. The "Smart Wedge" module provides an automated estimate of PAPO as well as a signal quality indicator ("wedge index"), designed to assess the reliability of the measurement and alert the operator in the event of an unusable signal. This algorithm underwent regulatory validation based on retrospective data compared to an expert interpretation of selected tracings, leading to its approval for clinical use.
Assess the agreement between PAOP values measured by the "Smart Wedge" algorithm and PAOP values analyzed by an expert in patients in shock who are being monitored via a pulmonary artery catheter (Swan Ganz IQ)
The concordance between manual PAOP and automatic PAOP (assessed by the SmartWedge algorithm during the inflation of the ballon in the arterial pulmonary).
Time frame: 1 day
Identify situations where there is a risk of discrepancy in the "Smart Wedge" value
Identify situations where there is a risk of discrepancy in the "Smart Wedge" value: mechanical ventilation vs. spontaneous ventilation, high auto-PEEP, mitral regurgitation, arrhythmia.
Time frame: 1 day
Assess the variability between PAOP values measured by the Smart Wedge algorithm and those measured by an expert.
Describe the variation and the relationship between the PAOP values measured by the "Smart Wedge" algorithm and those determined by expert interpretation.
Time frame: 1 day
Assess the agreement between the PAPO value provided by the "Smart Wedge" algorithm and the PAPO value used in clinical practice, and compare it to the agreement observed between the algorithm and the expert interpretation performed retrospectively.
Evaluate the agreement between the PAPO value provided by the "Smart Wedge" algorithm and the PAPO value used in clinical practice at the patient's bedside (as recorded in the medical record by the attending clinician), and compare this agreement to that observed between the algorithm and the expert reading performed retrospectively.
Time frame: 1 day
No study locations are listed for this record.
Plan to share: No
No publications or documents are linked to this record.
Start is estimated for Jul 2026; primary completion for Jul 2028, 24 months later.
Of 189 non-industry observational studies under Shock, Septic, half reached primary completion within 25 months of starting (the median), counting those still running; a quarter within 13 and three quarters within 47. This study's planned 24 months is close to that.
Counting every sponsor, half of 202 studies reached it within 25 months; a quarter within 12 and three quarters within 47.
How these figures are worked out, and which studies are left out of them.
This study is not yet recruiting, as verified in Jun 2026. You cannot join it, but the record below documents what was studied.
Get an email when the registry record changes — status, dates, results — or when someone posts here.
Sign in to followQuestions and observations about this study, from anyone following it. Not medical advice, and not a channel to the study team — their contact details are on the registry record.
Sign in to join the discussion. Reading takes no account; posting does. You choose a display name, and a pseudonym is the default.
Nothing here yet. If you are running this trial, taking part in it, or weighing whether to, this is the place to say so.
Assistance Publique - Hôpitaux de Paris →