Prospective, Randomized, Parallel-group Comparison of Two Refractive EDOF Intraocular Lenses: Johnson & Johnson Tecnis PureSee Versus 1stQ Comfort Z-EDOF

An interventional study of Tecnis PureSee IOL implantation and 1stQ Comfort Z-EDOF IOL implantation in Cataract, sponsored by Vienna Hospital Association. Not yet recruiting at 1 site in Austria. Open to participants aged 40 Years and older. Per ClinicalTrials.gov, last updated 2026-07-07.

Sponsored by Vienna Hospital Association · Not applicable, Interventional, and Treatment

Phase
Not applicable
Study type
Interventional
Enrollment
110
Allocation
Randomized
Ages
40 Years and older
Sex
All
01

Study summary

This study compares two types of artificial lens (intraocular lens, or IOL) used during cataract surgery. Both are extended depth-of-focus (EDOF) lenses, designed to give clear vision across a range of distances - far and intermediate - so that people depend less on glasses after surgery. The two lenses, the Tecnis PureSee and the 1stQ Comfort Z-EDOF, use different optical designs, and it is not yet known whether one provides a wider range of clear vision than the other.

Adults having cataract surgery in both eyes may take part. Each participant is randomly assigned to receive one of the two lens types, and the same lens type is implanted in both eyes. Neither the participant nor the staff measuring vision knows which lens was used until the main 6-month assessment is complete.

After surgery, participants attend check-ups at 1, 3, and 6 months. The study measures how wide a range of distances each person can see clearly, along with vision at different distances, quality of vision, side effects such as glare or halos, and overall satisfaction. The results will help doctors and patients choose between these lens types.

Read the detailed description

Background and rationale: Extended depth-of-focus (EDOF) intraocular lenses (IOLs) extend the range of functional vision beyond that of conventional monofocal IOLs by modifying the eye's wavefront to create an elongated focal range, while aiming to limit the photic phenomena (halos, glare, starbursts) often associated with multifocal IOLs. Different EDOF platforms use fundamentally different optical strategies, yet direct comparative evidence between EDOF designs from prospective randomized trials is limited; most published studies compare an EDOF IOL with monofocal or multifocal lenses rather than with another EDOF design. This trial provides a head-to-head comparison of two purely refractive EDOF platforms that employ different optical principles: the Tecnis PureSee (Johnson \& Johnson Vision), a refractive EDOF design with a continuous power profile and negative spherical aberration, and the 1stQ Comfort Z-EDOF (1stQ GmbH), a refractive aspheric EDOF design with a modified spherical aberration profile.

Design: This is a single-center, prospective, randomized, parallel-group comparative study conducted at the Department of Ophthalmology, Klinik Hietzing, Vienna, Austria. Patients undergoing bilateral cataract surgery are randomized 1:1 to receive one of the two EDOF IOL platforms, implanted bilaterally (the same platform in both eyes). Randomization uses permuted blocks and is stratified by toric versus non-toric IOL variant; patients with preoperative corneal astigmatism greater than 0.75 D receive the toric version of the assigned platform. Target refraction is emmetropia in the dominant eye and approximately -0.50 D in the non-dominant eye. Participants and outcome assessors are masked to lens allocation until the 6-month primary endpoint assessment is complete; the operating surgeon cannot be masked.

The study compares monocular (eye-level) and binocular (patient-level) outcomes between the two platforms. The primary endpoint is the monocular distance-corrected defocus range at the 0.2 logMAR threshold, measured 6 months after surgery from a standardized defocus curve (4-meter ETDRS chart, defocus +1.0 D to -3.5 D in 0.5 D steps). Secondary assessments include visual acuity at multiple distances, the complete defocus curve, manifest refraction and astigmatic vector components, higher-order wavefront aberrations, rotational stability of the toric variants, patient-reported visual function and quality of vision (including halos, glare, and starbursts), spectacle independence, satisfaction, and surgical safety.

Assessments are performed preoperatively and at 1, 3, and 6 months postoperatively. The primary analysis compares the mean monocular defocus range between groups using one eye per patient (the first-operated eye), with sensitivity analyses using both eyes and appropriate adjustment for within-patient correlation. The study is regulated as a post-market clinical follow-up (PMCF) investigation under Article 74(1) of Regulation (EU) 2017/745; both lenses are CE-marked and used within their approved intended purpose.

02

Conditions studied

  • Cataract

Browse trials for

Keywords

  • EDOF intraocular lens
03

In context

Cataract

1,629 studies on the registry are indexed under Cataract; 235 are open to participants now.

This study's planned enrollment of 110 is above the median of 79 across 1,092 interventional studies indexed under Cataract.

Browse Cataract studies →

Lead sponsor

Vienna Hospital Association is the lead sponsor of 11 studies on the registry; 7 are open to participants now.

Counted across the registry records on this site, refreshed daily.

04

Who can participate

Ages eligible
40 Years and older
Sexes eligible
All
Accepts healthy volunteers
No

Go through the criteria one by one — yes, no or not sure — and take the list to your doctor or the study team. Kept in this browser only.

Inclusion criteria

  • Age ≥40 years, able to understand the study and give written
  • bilateral age-related cataract suitable for phacoemulsification with posterior chamber IOL implantation
  • Expected postoperative best-corrected visual acuity ≤0.2 logMAR in both eyes
  • Regular corneal astigmatism ≤4.5 D in both eyes (IOLMaster 700)
  • Axial length 21.5-26.5 mm in both eyes
  • Clear cornea without clinically significant opacities, scars, or stromal dystrophies
  • Normal pupil function; no significant anisocoria (≥1 mm) and no afferent pupillary defect
  • Acceptance of the target refraction strategy: emmetropia in the dominant eye and -0.50 D in the non-dominant eye
  • Willing and able to attend all follow-up visits (Month 1, 3, and 6)
  • Written informed consent obtained before any study-related procedure

Exclusion criteria

Exclusion Criteria:

  • Prior corneal refractive surgery, corneal transplantation, glaucoma filtering surgery, or vitreoretinal surgery in either eye (uncomplicated intravitreal injections allowed)
  • Irregular astigmatism, keratoconus, forme fruste keratoconus, corneal ectasia, significant corneal opacities or scars, or endothelial dystrophy
  • Keratometric astigmatism >4.5 D in either eye
  • Axial length \<21.5 mm or >26.5 mm in either eye
  • Calculated IOL power outside the available range of either study lens
  • Macular pathology expected to limit visual acuity (e.g., age-related macular degeneration, diabetic maculopathy, epiretinal membrane, macular hole)
  • Advanced glaucoma with central visual field involvement, or IOP not controlled on ≤2 topical medications
  • Optic neuropathy expected to limit visual potential
  • Pre-existing amblyopia in either eye
  • Significant anisocoria, afferent pupillary defect, non-dilating pupil, or iris abnormalities affecting IOL function or measurement
  • Endothelial cell density \<1500 cells/mm²
  • Uncontrolled diabetes mellitus ( >9%) or disease with active ocular involvement
  • Systemic medications affecting pupil size that cannot be discontinued (e.g., tamsulosin)
  • Pregnancy or breastfeeding
  • Intraoperative complication precluding safe in-the-bag IOL implantation (affected eyes withdrawn)
  • Cognitive impairment, language barrier, or other factors preventing reliable participation
  • Current enrollment in another interventional clinical study affecting visual outcomes
Terms in these criteria, in plain language(4)

Underlined terms in the criteria open these too. Explained by clinicaltrials.gg, not part of the registry record. The study team decides who can take part.

Informed consent

Before you join, the study team explains what taking part involves — its purpose, what happens, the risks and possible benefits — and answers your questions, so you can decide freely. Consent is usually recorded on a form (the informed consent form, ICF) signed by you or, where the law allows, by someone legally authorised to decide for you.

You can keep asking questions during the study, you are told of new information that matters, and you can choose to leave at any time.

Clinically significant

Judged by the study doctor to matter for your health or for the study. It is a doctor’s decision, so ask the study team if you are unsure whether something counts.

HbA1c

A blood test of average blood sugar over the past two to three months, given as a percentage or in mmol/mol. 6.5% (48 mmol/mol) or more is the usual threshold for diabetes, normally confirmed by a second test.

Autoimmune disease

A condition in which the immune system attacks the body’s own tissues, such as rheumatoid arthritis, lupus, psoriasis, type 1 diabetes or inflammatory bowel disease.

Immunotherapy studies often leave out active autoimmune disease, and some name exceptions, such as thyroid disease on replacement hormone. Check the exceptions this study lists.

05

Study design

Phase
Not applicable
Primary purpose
Treatment
Allocation
Randomized
Intervention model
Parallel assignment
Masking
Double (Participant, Outcomes assessor)
Enrollment
110 participants (estimated)

Study arms

  • Experimental
    Tecnis PureSee

    Bilateral implantation of the Tecnis PureSee refractive extended depth-of-focus IOL (Johnson \& Johnson Vision; non-toric model ZEN00V or toric DET series). The same lens platform is implanted in both eyes. Target refraction: emmetropia in the dominant eye and approximately -0.50 D in the non-dominant eye.

    Device: Tecnis PureSee IOL implantation

  • Active comparator
    1stQ Comfort Z-EDOF

    Bilateral implantation of the 1stQ Comfort Z-EDOF refractive extended depth-of-focus IOL (1stQ GmbH; non-toric models B1XBY0/S1XBY0 or toric B1ZBY0). The same lens platform is implanted in both eyes. Target refraction: emmetropia in the dominant eye and approximately -0.50 D in the non-dominant eye.

    Device: 1stQ Comfort Z-EDOF IOL implantation

Interventions

  • DeviceTecnis PureSee IOL implantation

    Phacoemulsification with bilateral implantation of the Tecnis PureSee refractive EDOF IOL in the capsular bag. Toric variant used for preoperative corneal astigmatism greater than 0.75 D.

  • Device1stQ Comfort Z-EDOF IOL implantation

    Phacoemulsification with bilateral implantation of the 1stQ Comfort Z-EDOF refractive EDOF IOL in the capsular bag. Toric variant used for preoperative corneal astigmatism greater than 0.75 D.

06

What researchers measure

Primary outcomes

  1. Monocular distance-corrected defocus range (DCDR) at 0.2 logMAR

    Maximum contiguous defocus span (in diopters) over which monocular distance-corrected visual acuity remains ≤0.2 logMAR, derived from a standardized defocus curve (4 m ETDRS chart; +1.0 D to -3.5 D in 0.5 D steps).

    Time frame: 6 months after surgery

Secondary outcomes

  1. Monocular visual acuity at multiple distances

    logMAR acuity: UDVA and CDVA (4 m); UIVA at 66 cm and 80 cm and DCIVA (intermediate); UNVA at 40 cm and DCNVA (near).

    Time frame: 6 months after surgery

07

Study locations

1 site
08

References and documents

Individual participant data

Plan to share: No

No publications or documents are linked to this record.

09

Timeline

Tracking since Sep 25, 2026
ElapsedEstimatedEstimated, not yet reachedSimilar studies: half by the dot; the band is the middle halfHalf of similar studies reached it by the dot; the band is the middle half, from a quarter to three quarters

Start is estimated for Aug 2026; primary completion for Apr 2029, 32 months later.

Of 300 non-industry interventional studies with no phase under Cataract, half reached primary completion within 18 months of starting (the median), counting those still running; a quarter within 7 and three quarters within 30. This study's planned 32 months is above that.

Counting every sponsor, half of 490 studies reached it within 17 months; a quarter within 9 and three quarters within 28.

How these figures are worked out, and which studies are left out of them.

Registered
Jun 30, 2026
First posted
Jul 7, 2026
StartEst.
Aug 1, 2026
Primary completionEst.
Apr 1, 2029
CompletionEst.
Apr 1, 2029
Last update
Jul 7, 2026
What these dates mean
Start.
When the first participant enrolled; while estimated, when the study expects to open to recruitment.
Primary completion.
When the last participant was examined or treated to collect data for the study's main question, its primary outcome. A study that stopped early gives the date its data collection stopped.
Completion.
When the last participant's last visit took place, for every outcome, secondary ones and side effects included: the end of the study. Often later than primary completion, sometimes the same day.
Actual and Est.
Actual means the registry says the date has happened. Est. (estimated) is a date the sponsor plans or expects. It can still move, and the sponsor is expected to change it to actual once it has passed.
No changes since tracking began. The registry record was last updated on Jul 7, 2026, before this site started recording changes on Sep 25, 2026. Its history is on ClinicalTrials.gov ↗
10

Registry details

Key details

Study ID
NCT07688681
Lead sponsor
Vienna Hospital Association
Responsible party
Prim. Univ.-Prof. Dr. Pia Veronika Vécsei-Marlovits, MSc, MB (Prim.a Univ.-Prof.in Dr.in Pia Veronika Vécsei-Marlovits, MSc, MBA, Vienna Hospital Association) — Principal investigator
First posted
Jul 7, 2026
Start date
Aug 1, 2026 (estimated)
Primary completion
Apr 1, 2029 (estimated)
Completion
Apr 1, 2029 (estimated)
Last update
Jul 7, 2026

Study contacts

Michal Klimek, MD
Contact
klimek.michael@gmx.at
+43 650 460 7496

Oversight

Data monitoring committee
No
FDA-regulated drug
No
FDA-regulated device
No
View the source record on ClinicalTrials.gov ↗

Not currently enrolling

This study is not yet recruiting, as verified in Jun 2026. You cannot join it, but the record below documents what was studied.

Follow this study

Get an email when the registry record changes — status, dates, results — or when someone posts here.

Sign in to follow

Discussion

Questions and observations about this study, from anyone following it. Not medical advice, and not a channel to the study team — their contact details are on the registry record.

Sign in to join the discussion. Reading takes no account; posting does. You choose a display name, and a pseudonym is the default.

Nothing here yet. If you are running this trial, taking part in it, or weighing whether to, this is the place to say so.

Start the discussion