CClinicalTrials.gg
Not yet recruitingNCT07682805Updated Jul 6, 2026

STSC-HybridAPC Trial

An interventional study of Snare Tip Soft Coagulation (STSC) and Hybrid APC (ERBE) in Colon Adenomas and Colon Adenomatous Polyp, sponsored by Western Sydney Local Health District. Not yet recruiting at 1 site in Australia. Open to participants aged 18 Years and older. Per ClinicalTrials.gov, last updated 2026-07-06.

Sponsored by Western Sydney Local Health District · Not applicable, Interventional, and Treatment

Phase
Not applicable
Study type
Interventional
Enrollment
140
Allocation
Randomized
Ages
18 Years and older
Sex
All
01

Study summary

Margin thermal ablation after piecemeal EMR significantly reduces recurrence of large colorectal polyps. As recurrence rates are now low, the key implementation question relates to efficiency and reproducibility of different ablation techniques. This randomized controlled trial compares snare tip soft coagulation (STSC) with Hybrid APC (ERBE), with procedural time as the primary endpoint.

Read the detailed description

Piecemeal endoscopic mucosal resection (EMR) of large (≥20 mm) non-pedunculated colorectal lesions was historically associated with local recurrence rates in the range of 15-20% at first surveillance when no systematic margin therapy was applied¹. The introduction of structured post-EMR margin thermal ablation has substantially altered this landscape. In a landmark randomized controlled trial, systematic thermal ablation of the resection margin reduced recurrence from 21% to 5%². Subsequent prospective and multicenter studies performed in high-volume expert centers using standardized circumferential snare-tip soft coagulation (STSC) protocols have demonstrated further reductions, with reported recurrence rates approaching 1-2%³. Most recently, Gauci et al. demonstrated that complete margin thermal ablation eliminates lesion size as a risk factor for recurrence following piecemeal EMR of large non-pedunculated colorectal polyps, reinforcing the durability and consistency of this approach in contemporary practice⁴. These findings are supported by meta-analytic data confirming that thermal margin ablation significantly reduces recurrence compared with no ablation without increasing clinically meaningful adverse events⁵. Accordingly, current international guidelines strongly recommend routine thermal ablation of the post-EMR mucosal defect margin following piecemeal resection of large colorectal lesions⁶.

Given that recurrence rates are now low when complete circumferential ablation is systematically performed, additional trials powered for recurrence would require prohibitively large sample sizes to detect incremental differences. The remaining clinically relevant gap therefore relates not to efficacy, but to procedural efficiency, reproducibility, and implementation, particularly in early-career or non-advanced interventional endoscopists.

Snare-tip soft coagulation requires precise contact-based application of thermal energy at each point sequentially along the entire resection margin, demanding consistent tip positioning and repeated fine manipulations. This technical precision may be particularly challenging for endoscopists with limited experience, increasing the risk of incomplete ablation or prolonged procedural time.

Hybrid APC (ERBE) delivers thermal energy via a non-contact argon plasma beam with a broader coagulation footprint per activation, potentially enabling faster and more reproducible circumferential coverage with fewer individual applications. The wider energy spread of Hybrid APC may therefore reduce operator-dependent variability and facilitate more consistent margin treatment, particularly in the hands of early-career endoscopists. Whether this translates into a meaningful reduction in net ablation time and improved completion rates compared with STSC has not been prospectively evaluated.

02

Conditions studied

  • Colon Adenomas
  • Colon Adenomatous Polyp
03

Who can participate

Ages eligible
18 Years and older
Sexes eligible
All
Accepts healthy volunteers
No

Inclusion criteria

  • Age ≥18 years
  • Undergoing piecemeal EMR of a non-pedunculated colorectal lesion ≥20 mm in size
  • Macroscopically complete resection achieved prior to margin ablation (no visible residual adenomatous tissue at the resection base)
  • Ability to provide written informed consent

Exclusion criteria

Exclusion Criteria:

  • Lesions requiring en bloc resection by ESD
  • Lesions with suspected deep submucosal invasion based on endoscopic assessment (e.g., depressed morphology, non-lifting sign, NICE type 3 pattern, or equivalent advanced imaging criteria)
  • Inflammatory bowel disease with active colitis at the lesion site
  • Overt invasive carcinoma requiring surgical management
  • Pregnancy
  • Inability to provide informed consent
04

Study design

Phase
Not applicable
Primary purpose
Treatment
Allocation
Randomized
Intervention model
Parallel assignment
Masking
None (open label)
Enrollment
140 participants (estimated)

Study arms

  • Active comparator
    Snare Tip Soft Coagulation (STSC)

    Circumferential thermal ablation of the resection margin will be performed using the distal tip of a standard polypectomy snare in soft coagulation mode. The tip will be applied sequentially to the entire visible mucosal defect margin to achieve complete circumferential treatment.

    Procedure: Snare Tip Soft Coagulation (STSC)

  • Active comparator
    Hybrid APC (ERBE)

    Circumferential thermal ablation of the resection margin will be performed using Hybrid APC (ERBE) in standard APC mode. The argon plasma beam will be applied sequentially to the entire visible mucosal defect margin to achieve complete circumferential treatment. Electrosurgical settings will be standardized according to unit protocol (effect and wattage predefined for Hybrid APC use).

    Procedure: Hybrid APC (ERBE)

Interventions

  • ProcedureSnare Tip Soft Coagulation (STSC)

    Circumferential thermal ablation of the resection margin will be performed using the distal tip of a standard polypectomy snare in soft coagulation mode. The tip will be applied sequentially to the entire visible mucosal defect margin to achieve complete circumferential treatment.

  • ProcedureHybrid APC (ERBE)

    Circumferential thermal ablation of the resection margin will be performed using Hybrid APC (ERBE) in standard APC mode. The argon plasma beam will be applied sequentially to the entire visible mucosal defect margin to achieve complete circumferential treatment. Electrosurgical settings will be standardized according to unit protocol (effect and wattage predefined for Hybrid APC use).

05

What researchers measure

Primary outcomes

  1. Net margin ablation time

    Net margin ablation time (seconds), defined as the elapsed time from the first application of thermal energy to the resection margin (first activation in soft coagulation mode) until the operator declares completion of circumferential margin ablation. Time will be recorded using a standardized stopwatch method by a trained assistant/nurse (or captured from time-stamped video, if available). Interruptions unrelated to margin ablation (e.g., equipment troubleshooting) will be documented and excluded from net time where feasible, with sensitivity analyses planned.

    Time frame: during the procedure

Secondary outcomes

  1. Time (total)

    Total procedure time (minutes): from first endoscopic view of the lesion to scope withdrawal.

    Time frame: during procedure

  2. Technical success of margin ablation

    Technical success of margin ablation: completion of circumferential thermal treatment of the entire visible mucosal defect margin as judged by the supervising endoscopist and recorded as yes/no.

    Time frame: during procedure

  3. Instrument exchanges (count)

    Instrument exchanges (count): number of device exchanges required after completion of EMR to achieve margin ablation.

    Time frame: during procedure

  4. Need for additional haemostatic therapy (yes/no)

    Need for additional haemostatic therapy (yes/no): including clips, APC outside assigned intervention, injectable agents, or other modalities used for bleeding control.

    Time frame: during procedure

  5. Operator-rated ease of use (VAS 0-10)

    Operator-rated ease of use (VAS 0-10): recorded immediately post-procedure (0 = very difficult, 10 = very easy)

    Time frame: during procedure

  6. Operator confidence (VAS 0-10)

    Operator confidence (VAS 0-10): confidence that ablation was complete (0 = not confident, 10 = fully confident).

    Time frame: during procedure

  7. Immediate adverse events

    Immediate adverse events: intraprocedural and early post-procedural events as per standard definitions (bleeding requiring endoscopic therapy, perforation, post-polypectomy syndrome, unplanned admission). Severity will be graded using an accepted endoscopy AE severity framework (e.g., ASGE lexicon).

    Time frame: during procedure

  8. Cost impact (exploratory)

    Cost impact (exploratory): incremental procedural cost derived from device utilization (snare tip vs Hybrid APC), number of exchanges, and additional haemostatic devices used.

    Time frame: during procedure

  9. Rate of incomplete STSC margin ablation by trainee operators (yes/no, Arm A only)

    Rate of incomplete STSC margin ablation by trainee operators (yes/no, Arm A only): proportion of Arm A cases in which the supervising endoscopist judged circumferential margin ablation to be incomplete at the conclusion of the trainee's attempt, necessitating supplementary ablation by the supervisor.

    Time frame: during procedure

06

Study locations

1 site
07

References and documents

Publications

  • Ferlitsch M, Hassan C, Bisschops R, Bhandari P, Dinis-Ribeiro M, Risio M, Paspatis GA, Moss A, Libanio D, Lorenzo-Zuniga V, Voiosu AM, Rutter MD, Pellise M, Moons LMG, Probst A, Awadie H, Amato A, Takeuchi Y, Repici A, Rahmi G, Koecklin HU, Albeniz E, Rockenbauer LM, Waldmann E, Messmann H, Triantafyllou K, Jover R, Gralnek IM, Dekker E, Bourke MJ. Colorectal polypectomy and endoscopic mucosal resection: European Society of Gastrointestinal Endoscopy (ESGE) Guideline - Update 2024. Endoscopy. 2024 Jul;56(7):516-545. doi: 10.1055/a-2304-3219. Epub 2024 Apr 26. PubMed 38670139 ↗
  • Gauci JL, Mandarino FV, Kerrison C, Whitfield AM, O'Sullivan T, Gupta S, Lam B, Perananthan V, Cronin O, Lee EY, Williams SJ, Burgess N, Bourke MJ. Margin thermal ablation eliminates size as a risk factor for recurrence after piecemeal endoscopic mucosal resection of large non-pedunculated colorectal polyps. Gut. 2025 Apr 7;74(5):752-760. doi: 10.1136/gutjnl-2024-333563. PubMed 40044497 ↗
  • Belderbos TD, Leenders M, Moons LM, Siersema PD. Local recurrence after endoscopic mucosal resection of nonpedunculated colorectal lesions: systematic review and meta-analysis. Endoscopy. 2014 May;46(5):388-402. doi: 10.1055/s-0034-1364970. Epub 2014 Mar 26. PubMed 24671869 ↗

Individual participant data

Plan to share: No

08

Registry details

Key details

Study ID
NCT07682805
Lead sponsor
Western Sydney Local Health District
Responsible party
Professor Michael Bourke (Professor Michael Bourke, Western Sydney Local Health District) — Principal investigator
First posted
Jul 6, 2026
Start date
Jan 1, 2027 (estimated)
Primary completion
Aug 1, 2027 (estimated)
Completion
Aug 15, 2027 (estimated)
Last update
Jul 6, 2026

Study contacts

Kathleen Goodrick, BN
Contact
kathleen.goodrick@health.nsw.gov.au
+612 88905555
Mayan Eitan, MD
Contact
mayan.eitan@health.nsw.gov.au
+612 88905555
Michael J Bourke, MBBS
principal investigator · WSLHD

Oversight

Data monitoring committee
No
FDA-regulated drug
No
FDA-regulated device
No
View the source record on ClinicalTrials.gov ↗

Not currently enrolling

This study is not yet recruiting, as verified in Jun 2026. You cannot join it, but the record below documents what was studied.

Follow this study

Get an email when the registry record changes — status, dates, results — or when someone posts here.

Sign in to follow

Discussion

Questions and observations about this study, from anyone following it. Not medical advice, and not a channel to the study team — their contact details are on the registry record.

Sign in to join the discussion. Reading takes no account; posting does. You choose a display name, and a pseudonym is the default.

Nothing here yet. If you are running this trial, taking part in it, or weighing whether to, this is the place to say so.

Start the discussion