An observational study in Hemodynamic Changes, sponsored by Università Politecnica delle Marche. Recruiting at 1 site in Italy. Open to participants aged 18 Years and older. Per ClinicalTrials.gov, last updated 2026-03-30.
Sponsored by Università Politecnica delle Marche · Observational
Help build ClinicalTrials.gg — short surveys, remote interviews or testing, in your language. Take part →
According to Guyton's model of venous return, the fluids that effectively increase cardiac output are those that, once administered, increase the vascular stressed volume, thereby increasing the mean systemic filling pressure (Pms) without increasing the central venous pressure (CVP). In this way, since the gradient between Pms and CVP increases, venous return-and consequently cardiac output-also increases.
In cases where physiologically ineffective fluids are administered, the situation arises in which, in addition to increasing the stressed volume and thus Pms, CVP also increases. As a result, the gradient between Pms and CVP remains unchanged, and cardiac output does not increase.
The hypothesis is that only a portion of the fluids administered during volume expansion are actually effective in increasing the gradient between Pms and CVP.
Università Politecnica delle Marche is the lead sponsor of 48 studies on the registry; 4 are open to participants now.
Counted across the registry records on this site, refreshed daily.
Critically ill patients
Go through the criteria one by one — yes, no or not sure — and take the list to your doctor or the study team. Kept in this browser only.
Exclusion Criteria:
Underlined terms in the criteria open these too. Explained by clinicaltrials.gg, not part of the registry record. The study team decides who can take part.
A reason a treatment, test or procedure should not be given to a particular person, such as an allergy, another illness or a medicine they take.
Contraindication
A reason a treatment, test or procedure should not be given to a particular person, such as an allergy, another illness or a medicine they take.
Explained by clinicaltrials.gg, not part of the registry record. The study team decides who can take part.
The mean systemic filling pressure (Pms) will be measured using the transient stop-flow arm technique, a method routinely used in clinical practice. This involves placing a non-invasive blood pressure cuff on the same arm where invasive arterial pressure is monitored via the radial artery. The cuff is inflated for one minute to temporarily occlude blood flow. At the end of this period, the invasive arterial pressure displayed on the monitor reflects the Pms. This brief interruption of blood flow does not pose significant risks to tissue perfusion. A fluid challenge with 500 mL of crystalloids will then be performed as per clinical indication. Pms will be measured at baseline, after the infusion of 150 mL, 250 mL, 500 mL, and one hour after the end of fluid administration. Central venous pressure (CVP) and cardiac index (CI) will be continuously monitored throughout the fluid challenge. Patients will be classified as fluid responders if stroke volume (SV) increases by more than
Variation of the Venous Return Gradient (Pms - CVP) in Fluid Responders
To describe the change in the venous return gradient (mean systemic filling pressure minus central venous pressure, Pms - CVP) during volume expansion with 500 mL of crystalloids in fluid responsive patients. The fluid challenge is administered according to the clinician's indication. A total of 500 mL of crystalloids is infused over 25 minutes, corresponding to an infusion rate of 1200 mL/h.
Time frame: Measurements are taken at baseline, and at 7 minutes and 30 seconds, 12 minutes and 30 seconds, and 25 minutes from the start of crystalloid infusion (corresponding to 150 mL, 250 mL, and 500 mL infused, respectively).
Venous Return Gradient Variation in Fluid Responders vs Non-Responders
To compare the change in Pms - CVP between fluid responders and non-responders during volume expansion with 500 mL of crystalloids. The fluid challenge is administered according to the clinician's indication. A total of 500 mL of crystalloids is infused over 25 minutes, corresponding to an infusion rate of 1200 mL/h.
Time frame: Measurements are taken at baseline, and at 7 minutes and 30 seconds, 12 minutes and 30 seconds, and 25 minutes from the start of crystalloid infusion (corresponding to 150 mL, 250 mL, and 500 mL infused, respectively).
Venous Return Gradient Variation in the General Population
To describe the changes in Pms - CVP in the overall study population during volume expansion with 500 mL of crystalloids in fluid responsive patients. The fluid challenge is administered according to the clinician's indication. A total of 500 mL of crystalloids is infused over 25 minutes, corresponding to an infusion rate of 1200 mL/h.
Time frame: Measurements are taken at baseline, and at 7 minutes and 30 seconds, 12 minutes and 30 seconds, and 25 minutes from the start of crystalloid infusion (corresponding to 150 mL, 250 mL, and 500 mL infused, respectively).
Cardiac Index Variation in the General Population
To assess changes in cardiac index in the overall study population during volume expansion with 500 mL of crystalloids. The fluid challenge is administered according to the clinician's indication. A total of 500 mL of crystalloids is infused over 25 minutes, corresponding to an infusion rate of 1200 mL/h.
Time frame: Measurements are taken at baseline, and at 7 minutes and 30 seconds, 12 minutes and 30 seconds, and 25 minutes from the start of crystalloid infusion (corresponding to 150 mL, 250 mL, and 500 mL infused, respectively).
Mean Systemic Filling Pressure (Pms) Variation in the General Population
To evaluate how Pms changes in the overall population during volume expansion with 500 mL of crystalloids. The fluid challenge is administered according to the clinician's indication. A total of 500 mL of crystalloids is infused over 25 minutes, corresponding to an infusion rate of 1200 mL/h.
Time frame: Measurements are taken at baseline, and at 7 minutes and 30 seconds, 12 minutes and 30 seconds, and 25 minutes from the start of crystalloid infusion (corresponding to 150 mL, 250 mL, and 500 mL infused, respectively).
Central Venous Pressure (CVP) Variation in the General Population
To describe how CVP varies in the overall population during volume expansion with 500 mL of crystalloids. The fluid challenge is administered according to the clinician's indication. A total of 500 mL of crystalloids is infused over 25 minutes, corresponding to an infusion rate of 1200 mL/h.
Time frame: Measurements are taken at baseline, and at 7 minutes and 30 seconds, 12 minutes and 30 seconds, and 25 minutes from the start of crystalloid infusion (corresponding to 150 mL, 250 mL, and 500 mL infused, respectively).
Cardiac Index Variation in Fluid Responders vs Non-Responders
To compare cardiac index changes between fluid responders and non-responders during volume expansion with 500 mL of crystalloids. The fluid challenge is administered according to the clinician's indication. A total of 500 mL of crystalloids is infused over 25 minutes, corresponding to an infusion rate of 1200 mL/h.
Time frame: Measurements are taken at baseline, and at 7 minutes and 30 seconds, 12 minutes and 30 seconds, and 25 minutes from the start of crystalloid infusion (corresponding to 150 mL, 250 mL, and 500 mL infused, respectively).
Mean Systemic Filling Pressure (Pms) Variation in Fluid Responders vs Non-Responders
To compare Pms changes between fluid responders and non-responders during volume expansion with 500 mL of crystalloids. The fluid challenge is administered according to the clinician's indication. A total of 500 mL of crystalloids is infused over 25 minutes, corresponding to an infusion rate of 1200 mL/h.
Time frame: Measurements are taken at baseline, and at 7 minutes and 30 seconds, 12 minutes and 30 seconds, and 25 minutes from the start of crystalloid infusion (corresponding to 150 mL, 250 mL, and 500 mL infused, respectively).
Central Venous Pressure (CVP) Variation in Fluid Responders vs Non-Responders
To evaluate CVP changes in fluid responders compared to non-responders during volume expansion with 500 mL of crystalloids. The fluid challenge is administered according to the clinician's indication. A total of 500 mL of crystalloids is infused over 25 minutes, corresponding to an infusion rate of 1200 mL/h.
Time frame: Measurements are taken at baseline, and at 7 minutes and 30 seconds, 12 minutes and 30 seconds, and 25 minutes from the start of crystalloid infusion (corresponding to 150 mL, 250 mL, and 500 mL infused, respectively).
Systemic Vascular Resistance (SVR) Variation in Fluid Responders vs Non-Responders
To describe and compare changes in systemic vascular resistance between fluid responders and non-responders during volume expansion with 500 mL of crystalloids. The fluid challenge is administered according to the clinician's indication. A total of 500 mL of crystalloids is infused over 25 minutes, corresponding to an infusion rate of 1200 mL/h.
Time frame: Measurements are taken at baseline, and at 7 minutes and 30 seconds, 12 minutes and 30 seconds, and 25 minutes from the start of crystalloid infusion (corresponding to 150 mL, 250 mL, and 500 mL infused, respectively).
Plan to share: Undecided
No publications or documents are linked to this record.
Started Mar 2025 (actual). Primary completion is estimated for Jul 2026, 16 months after the start.
How these figures are worked out, and which studies are left out of them.
Eligibility is decided by the study team. Share this record with your doctor or contact the team directly.
No contact was published for this record. The registry link below has the sponsor’s details.
Get an email when the registry record changes — status, dates, results — or when someone posts here.
Sign in to followQuestions and observations about this study, from anyone following it. Not medical advice, and not a channel to the study team — their contact details are on the registry record.
Sign in to join the discussion. Reading takes no account; posting does. You choose a display name, and a pseudonym is the default.
Nothing here yet. If you are running this trial, taking part in it, or weighing whether to, this is the place to say so.
Università Politecnica delle Marche