An observational study in Heart Failure and Pacemaker, sponsored by University of Leeds. Enrolling by invitation at 1 site in United Kingdom. Open to participants aged 18 Years and older. Per ClinicalTrials.gov, last updated 2026-01-28.
Sponsored by University of Leeds · Observational
Help build ClinicalTrials.gg — short surveys, remote interviews or testing, in your language. Take part →
Among 15 studies in Heart Failure by University of Leeds — 4 open to participants now, 5 under way, none of them phase 3. Heart Failure · University of Leeds.
Among the 15 studies in Heart Failure by University of Leeds, this one is one of 2 that started in 2025, is one of 5 observational ones, and was the 13th registered.
6,340 studies on the registry are indexed under Heart Failure; 1,397 are open to participants now.
Browse Heart Failure studies →4 of the 15 studies in Heart Failure by University of Leeds are open now, in 1 country. Recruiting first, the newest first:
University of Leeds · Sites in United Kingdom
Ages 18+ · Healthy volunteers
University of Leeds · Sites in United Kingdom
Ages 18+ · Healthy volunteers
University of Leeds · Sites in United Kingdom
Ages 40+
By country, each count listing its studies:
Of the 968 Heart Failure studies recruiting now, 691 (71%) set no upper age limit and 90 (9%) stop at 75 or younger; 64 take children under 18; 97 take healthy volunteers.
This study: 18 Years and older · all sexes · no healthy volunteers.
The full table on the hub →This tab as a report to print or save as PDF → With an account.
15 studies; the count open now beside each. This study's row is marked.
First in 2008; this study’s year is marked. 2 started in 2025.
By drug class, each counting the studies that test any of its medicines:
This study's planned enrollment of 150 is below the median of 200 across 1,987 observational studies indexed under Heart Failure.
Median enrollment 87 across the 10 interventional studies, 475 across the 5 observational. Of the 6 that completed or were terminated, 0 (0%) have results posted.
This tab as a report to print or save as PDF → With an account.
University of Leeds is the lead sponsor of 206 studies on the registry; 25 are open to participants now.
1 of the studies in Heart Failure by University of Leeds that are under way reach primary completion within a year, 0 of them phase 3. Phase 3 first, then by date:
| Study | Primary completion |
|---|---|
| NCT07367841University of LeedsFIND HF Risk-guided Screening for Heart Failure - Pilot Study | 2027-07 |
Add it to your calendar (.ics) → With an account.
Among the 15 studies in Heart Failure by University of Leeds, from their registry updates:
Nothing recorded among them since 2026-09-25.
This tab as a report to print or save as PDF → With an account.
Pacemakers are an effective treatment for slow heart rates which improve symptoms and save lives. However, for some people pacemakers can cause heart failure (HF) because of the unnatural way in which they stimulate heart beats. In several studies conducted in West Yorkshire we showed that \~1/3 of patients with pacemakers have undiagnosed HF. We also showed that where HF is discovered, treating it with safe and inexpensive medications reduces the chances of being admitted to hospital or dying. However, detecting HF requires an echocardiogram (a heart ultrasound scan) which takes \~45 minutes, requires a skilled technician, and costs £120; or, to put it another way \~£540,000 to assess the \~4,500 patients cared for at our hospital. A new approach is needed. We think that using new technologies can improve our ability to screen for HF in people with pacemakers. We will test two approaches. First, we will assess whether a hand-held echocardiogram can measure heart function using artificial intelligence (AI) as accurately as a standard echocardiogram done by a skilled technician. Second, we will assess whether a finger-prick blood test can detect the presence of abnormal function as accurately as a standard echocardiogram.
Pacemakers are an effective treatment for slow heart rates which improve symptoms and save lives. However, for some people pacemakers can cause heart failure (HF) because of the unnatural way in which they stimulate heart beats. In several studies conducted in West Yorkshire we showed that \~1/3 of patients with pacemakers have undiagnosed HF. We also showed that where HF is discovered, treating it with safe and inexpensive medications reduces the chances of being admitted to hospital or dying. However, detecting HF requires an echocardiogram (a heart ultrasound scan) which takes \~45 minutes, requires a skilled technician, and costs £120; or, to put it another way \~£540,000 to assess the \~4,500 patients in Leeds. A new approach is needed. We think that using new technologies might improve our ability to screen for HF in people with pacemakers. Hand-held devices which are capable of cardiac imaging, and measurement of heart failure using Artificial Intelligence (AI) are now commercially available. However, these devices have not been specifically developed to detect heart dysfunction in people with pacemakers. Pacemakers result in a specific form of heart muscle weakness which is different to that caused by other conditions which result in HF, therefore it is essential to prove its accuracy before use in routine clinical practice. Another possible way to detect heart muscle weakness is by first screening patients with a blood test. N-terminal B- type natriuretic peptide (NT-proBNP) is a peptide released by the heart in response to strain or stress, and usually elevated in people with heart failure. Devices are now commercially available which can provide a measurement of NT-proBNP from a finger prick blood test, and crucially within a few minutes so that the result might be known during a patients routine appointment. Whilst this blood test cannot provide a diagnosis, it might help identify individuals who are at higher risk and should go on to have a standard echocardiogram.
To make participation as simple as possible, and to avoid unnecessary visits to the hospital, patients will be approached prior to their routine pacemaker clinic appointment. Patients who have pacemakers attend the hospital every 6-12 months in person to undergo a check of their pacemaker's battery life and function. All potential participants will be identified by a member the patient's direct care team according to the study inclusion criteria. We will recruit patients with pacemakers and right ventricular pacing burden (the percentage of heat beats which are due to the pacemaker) ≥20% - this is important as we know that the risk of heart muscle weakness is correlated with the percentage of paced beats, with ≥20% being an accepted cut-off supported by our own data. We will exclude patients unable or unwilling to participate. We will also exclude patients with cardiac devices which mitigate against the risk of heart muscle weakness, or those likely to have been implanted for the management of known heart failure (conduction system pacemakers, cardiac resynchronisation therapy pacemakers/defibrillators, implantable cardioverter defibrillators, leadless pacemakers, single chamber atrial pacemakers).
Potential participants will be sent an Invitation Letter and the Patient Information Sheet, offering them the opportunity to attend an appointment in the Leeds Cardiovascular Clinical Research Facility instead of their usual pacemaker clinic appointment. This will then be followed up by a telephone call from the direct care team, and only those who are potentially interested and confirm their agreement to have their information passed to the research team will be approached to arrange an appointment. On the day of the appointment, a member of the research team will approach the patient, explain the study and offer the opportunity to ask questions. Participants will have already had at least one week to read the Participants Information Sheet and consider whether they wish to take part. If willing to participate, they will then provide written consent to undertake the study procedures. All patients, regardless of whether they consent to participate, or not, will have a pacemaker safety check by an accredited cardiac physiologist. If patients agree to participate their appointment would last around one hour, for comparison a routine pacemaker appointment lasts around 20 minutes. Following the appointment their next appointment with their usual care team will be scheduled.
Generic study procedures: Participants will undergo a routine device interrogation by an accredited cardiac physiologist as per usual clinical care to confirm device functionality and right ventricular pacing burden ≥20%. For participants who consent to participate the research team will collect demographic and clinical information from their electronic healthcare record. Participants will then undergo point-of-care blood testing for NTpro-BNP, a hand-held echocardiogram and a standard cart-based echocardiogram. Point-of-care NTpro-BNP blood testing: LumiraDx (LumiraDx Ltd, Cayman Islands) is a quantitative point-of-care, fingerpick blood test capable of measuring various biomarkers using a micro-sample of blood obtained from a finger prick. NT-proBNP is a routine blood test used to diagnose and monitor heart failure. The LumiraDx can measure NTpro-BNP with only 20uL of blood, is highly portable, with a turn-around time of only 12 minutes - feasible within the time constraints of a standard pacemaker follow-up appointment. For the patient, this entails having a small quantify of blood taken from a finger prick. The process results in very minimal discomfort and is almost identical to blood sugar testing patients with diabetes are requiring to do several times per day. Afterwards a small amount of cotton wool is placed on the finger tip and pressure applied. Their technology has been validated in a study of 659 samples compared to gold-standard commercially available laboratory equipment (Roche Cobas Elecsys proBNP II assay) and found to have comparable accuracy (slope 0.86, intercept -4.12, r 0.97).
Hand-held cardiac ultrasound: participants will undergo a focussed hand-held echocardiogram with AI derived LVEF using the Kosmos platform (EchoNous Inc., Redmond, USA) a point-of-care, hand-held ultrasound device capable of cardiac imaging, which uses US2.AI (Ultrasound Anyone Anywhere, Singapore) integrated AI driven software capable of automated measurement of LVEF. The Kosmos platform assists the operator to obtain optimal images, prompts the image to be acquired when the image has been optimised, and provides an immediate measurement of LVEF. Existing data suggest the Kosmos platform is able to reliably detect abnormal LVEF in patients referred with suspected HF, however there are no data describing its use in a population with pacing-induced left ventricular dysfunction. Hand-held echocardiography will be done by a specialist nurse or cardiac physiologist who does not hold accreditation in echocardiography. They will have previously received focussed training in obtaining the images required, which will be deliberately limited (≤1 day) so as to ensure our findings are generalisable to teams without experience of echocardiography.
Standard cart-based cardiac ultrasound: participants will undergo a transthoracic echocardiogram by a senior cardiac physiologist accredited by the British Society of Echocardiography (or equivalent international body) using a GE Healthcare Vivid E95 Ultra Edition Cardiac Ultrasound. For the participant this involves lying semi-reclined on a couch, with ultrasound images obtained from four locations on the chest wall. The scan takes around 25 minutes to obtain the images (with an additional 20 minutes to take measurements and prepare the report) and poses no risk to the patient. A minimum dataset will be obtained with LVEF measured by the biplane method where possible, as well as assess for any (at least) moderate valvular disease or other finding which could result in a change to patient management.
This is a cross-sectional study, participants will be assessed at a single point in time. Provided there are no abnormal findings, participants will then be booked to attend their next scheduled pacemaker follow-up appointment as planned.
Any serious adverse event (SAE) occurring in a research participant, where, in the opinion of the Chief Investigator the event was related to the administration of any of the research procedures will be reported to the Sponsor (governance- ethics@leeds.ac.uk) within one working day of the research team's awareness. SAE will be recorded during the participant's visit, and documented in the electronic healthcare record. Untoward events which occur after the study visit has been completed or are not directly related to the study visit will not be reported. It is anticipated that during this study we will identify important heart muscle weakness, or other abnormal findings on cardiac ultrasound. These findings, and any untoward event which occur as a consequence of new diagnoses/findings (such as hospitalisation) will not be reported to the Sponsor of Research Ethics Committee as these are regarded as being part of the patient's usual clinical care.
Patients with previously implanted pacemakers for bradycardia.
Go through the criteria one by one — yes, no or not sure — and take the list to your doctor or the study team. Kept in this browser only.
Exclusion Criteria:
Underlined terms in the criteria open these too. Explained by clinicaltrials.gg, not part of the registry record. The study team decides who can take part.
Before you join, the study team explains what taking part involves — its purpose, what happens, the risks and possible benefits — and answers your questions, so you can decide freely. Consent is usually recorded on a form (the informed consent form, ICF) signed by you or, where the law allows, by someone legally authorized to decide for you.
You can keep asking questions during the study, you are told of new information that matters, and you can choose to leave at any time.
The share of blood the heart’s main pumping chamber (the left ventricle) pushes out with each beat, measured by an echocardiogram (heart ultrasound) or a MUGA scan. About 50–70% is normal.
Informed consent
Before you join, the study team explains what taking part involves — its purpose, what happens, the risks and possible benefits — and answers your questions, so you can decide freely. Consent is usually recorded on a form (the informed consent form, ICF) signed by you or, where the law allows, by someone legally authorized to decide for you.
You can keep asking questions during the study, you are told of new information that matters, and you can choose to leave at any time.
Explained by clinicaltrials.gg, not part of the registry record. The study team decides who can take part.
LVEF (left ventricular ejection fraction)
The share of blood the heart’s main pumping chamber (the left ventricle) pushes out with each beat, measured by an echocardiogram (heart ultrasound) or a MUGA scan. About 50–70% is normal.
Explained by clinicaltrials.gg, not part of the registry record. The study team decides who can take part.
The accuracy of artificial intelligence derived left ventricular ejection fraction (LVEF) compared to expert sonographer measured LVEF
Determined by the individual equivalence coefficient of artificial intelligence (AI) derived left ventricular ejection fraction (LVEF) versus to sonographer measured LVEF. The accuracy of AI LVEF will be compared to sonographer measured LVEF for non-inferiority. The pre-determined non-inferiority margin is 0.25 for the upper bound of the 95% confidence interval for this comparison.
Time frame: Day 1
Accuracy of artificial intelligence derived left ventricular ejection fraction of <50%
The accuracy of artificial intelligence derived left ventricular ejection fraction (LVEF) of \<50% compared to standard cart-based echocardiography measurement of LVEF \<50% by biplane method, determined by sensitivity, specificity, positive and negative predictive values.
Time frame: Day 1
Prediction of left ventricular ejection fraction <50%
The incremental improvement of a model to predict left ventricular ejection fraction (LVEF) \<50% in a population with pacemakers of the addition of artificial intelligence derived LVEF, point of care N-terminal B-type natriuretic peptide, or both.
Time frame: Day 1
The utility of artificial intelligence echocardiography
The proportion of participants in whom it was not possible to determine artificial intelligence derived left ventricular ejection fraction (LVEF), LVEF measured by a sonographer using the biplane method, and subjective measurement of LVEF.
Time frame: Day 1
Plan to share: No
Started Oct 2025 (actual). Primary completion is estimated for Sep 2026, 11 months after the start.
How these figures are worked out, and which studies are left out of them.
Eligibility is decided by the study team. Share this record with your doctor or contact the team directly.
No contact was published for this record. The registry link below has the sponsor’s details.
Get an email when the registry record changes — status, dates, results — or when someone posts here.
Sign in to followQuestions and observations about this study, from anyone following it. Not medical advice, and not a channel to the study team — their contact details are on the registry record.
Sign in to join the discussion. Reading takes no account; posting does. You choose a display name, and a pseudonym is the default.
Nothing here yet. If you are running this trial, taking part in it, or weighing whether to, this is the place to say so.