ClinicalTrials.gg
Not yet recruitingNCT07164066Updated Sep 9, 2025

Digital vs Conventional Prosthetic Rehab & Occlusal Analysis in Edentulous Patients

An interventional study of Digital Occlusal Analysis Device in Edentulous Complete Denture Wearers and Dental Occlusion, sponsored by Mohammed Bin Rashid University of Medicine and Health Sciences. Not yet recruiting. Open to participants aged 18 Years and older. Per ClinicalTrials.gov, last updated 2025-09-09.

Sponsored by Mohammed Bin Rashid University of Medicine and Health Sciences · Not applicable, Interventional, and Treatment

Phase
Not applicable
Study type
Interventional
Enrollment
15
Allocation
Randomized
Ages
18 Years and older
Sex
All
01

Study summary

15 Patients requiring complete dentures will be recruited from Dubai Health. Each patient will receive two sets of dentures with a washout period between sets. Patients will remain blinded to the fabrication method used for each set.

  • Group 1: Participants will first receive conventionally fabricated dentures for both the upper and lower jaws. This set will be made using traditional techniques, including impressions, a custom tray, jaw relation recording, try-in, and final fitting. After the washout period, they will receive a second set created with the 3D-printed technique.
  • Group 2: Participants in this group will initially receive 3D-printed complete dentures through a digital workflow, which involves intraoral scanning, STL file export, digital design, design review with the patient, 3D printing, and final fitting. Following the washout period, they will then receive a conventionally fabricated set.
Read the detailed description

To ensure randomization and reduce order effects, participants will be randomly assigned to Group 1 or Group 2 using a stratified randomization approach in Microsoft Excel. A computer-generated random number will determine group allocation, ensuring that both groups have a balanced distribution based on age, gender, and oral health status. The randomization process will assign participants to either receive conventional dentures first (Group 1) or digital dentures first (Group 2), with a washout period between treatments. By randomizing the sequence of denture delivery, this method will control for potential biases in patient-reported outcomes (OHIP-14, DSQ) and clinical assessments, ensuring that the order of treatment does not influence the study results.

The following outcomes will be analysed:

  • Quality of life (Qol) through Oral Health Impact Profile (OHIP-14)
  • Patient reported outcomes (PROMS)
  • Occlusal analysis - through conventional and digital analysis devices
  • Costs
  • Number of appointments
  • Time AccuracyOutcome Measures The primary outcome of this study is the assessment of occlusal analysis using conventional and digital techniques.

The secondary outcomes include:

  • Oral health-related quality of life (OHRQoL), measured using the validated Oral Health Impact Profile (OHIP-14).
  • Patient-reported outcomes (PROMs), assessed through the Denture Satisfaction Questionnaire (DSQ), evaluating comfort, aesthetics, speech, and functional satisfaction.
  • Number of appointments, recorded as the total number of visits required for fabrication and delivery of both conventional and digital dentures.
  • Time efficiency, measured by recording the clinical duration required for key stages such as impressions and final insertions.
  • Denture accuracy, assessed through 3D scanning and superimposition analysis using Geomagic Control X software, quantifying deviations between the designed and fabricated dentures. Clinical evaluation of fit, retention, and stability will also be conducted using a standardized grading scale.
  • Cost-effectiveness, evaluated using a model adapted from McKenna et al. (2014), where the total cost per patient is divided by the OHIP-14 improvement score to yield a cost per one-point improvement in quality of life. This is benchmarked against the minimally important difference (MID), defined as a 5-point improvement:

Cost-effectiveness ratio = Total cost per patient / OHIP-14 improvement score Benchmark = Cost per point × 5 This model provides a practical and meaningful way to interpret cost relative to patient-perceived improvement, supporting decisions on the integration of digital denture workflows.

The factors will be analyzed through a combination of validated patient-reported outcome measures, digital and conventional assessment techniques, and cost-effectiveness evaluations. Quality of life (QOL) will be assessed using the Oral Health Impact Profile (OHIP-14), a validated measure of oral health-related quality of life, while patient-reported outcomes (PROMS) will be evaluated using the Denture Satisfaction Questionnaire (DSQ) to assess patient satisfaction with comfort, aesthetics, speech, and function of conventional and digital dentures. Occlusal analysis will be conducted using both conventional and digital methods. Articulating paper will be used to assess occlusal contact number and occlusal contact area through visual inspection, while T-Scan and Modjaw will provide quantitative measurements of occlusal force distribution and balance between conventional and digitally fabricated dentures.

Cost, time efficiency, and accuracy will be compared between fabrication techniques. The total number of clinical visits and time spent on clinical and laboratory procedures will be recorded to determine workflow efficiency. A comparative cost analysis will evaluate direct expenses (materials, fabrication) and indirect costs (adjustments, remakes). Denture accuracy will be assessed through 3D scanning and superimposition analysis using Geomagic Control X software, quantifying deviations between the designed and fabricated dentures. Additionally, the fit, retention, and stability of the dentures will be evaluated using a standardized clinical grading scale. Additionally, Accuracy is defined as "the degree to which the result of a measurement, calculation, or specification conforms to the correct value or a standard" . In this study, accuracy pertains to how closely the fabricated complete dentures whether produced via digital or conventional methods match their intended designs and clinical specifications.

To evaluate this:

  • Digital Dentures: The fabricated digital dentures will be scanned, and their STL files will be superimposed onto the original CAD designs using Geomagic Control X software. This process will generate a color-coded deviation map, quantifying discrepancies between the designed and fabricated dentures.
  • Conventional Dentures: Similarly, conventional dentures will be digitized to obtain their STL files. These will be superimposed onto the corresponding digital designs using the same software and methodology. This allows for a direct, quantitative comparison of the accuracy between conventional and digital fabrication methods.
  • Occlusal Accuracy: Occlusal accuracy will be assessed by evaluating the contact points and force distribution. For conventional dentures, articulating paper will be used to mark occlusal contacts, which will then be scanned to create digital models. These models will be superimposed onto the original designs using Geomagic Control X to analyze the location and distribution of occlusal contacts. For digital dentures, occlusal contacts will be assessed through the digital workflow, and similar superimposition techniques will be applied. This approach enables a comprehensive comparison of occlusal accuracy between the two fabrication methods.

By employing these standardized digital superimposition techniques, the study ensures a consistent and objective assessment of denture accuracy across both fabrication workflows, encompassing both the overall fit and occlusal parameters.

02

Conditions studied

  • Edentulous Complete Denture Wearers
  • Dental Occlusion

Keywords

  • Edentulism
  • Digital Occlusal Analysis
  • Digital Dentures
  • Quality of life
  • Occlusion
03

In context

Lead sponsor

Mohammed Bin Rashid University of Medicine and Health Sciences is the lead sponsor of 20 studies on the registry; 11 are open to participants now.

Counted across the registry records on this site, refreshed daily.

04

Who can participate

Ages eligible
18 Years and older
Sexes eligible
All
Accepts healthy volunteers
No

Go through the criteria one by one — yes, no or not sure — and take the list to your doctor or the study team. Kept in this browser only.

Inclusion criteria

  • Adults above the age of eighteen years seeking replacement of missing teeth
  • Edentulous patients 6 months after extraction of any teeth
  • Males and Females

Exclusion criteria

Exclusion Criteria:

  • Temporomandibular Joint Disorders(TMD)
  • Limited mouth opening
  • History of Head and neck oncology
  • Conditions- such as Psychiatric conditions and Neurological conditions-, such as Parkinson's disease and Alzheimer's
05

Study design

Phase
Not applicable
Primary purpose
Treatment
Allocation
Randomized
Intervention model
Crossover assignment
Masking
Single (Participant)
Enrollment
15 participants (estimated)

Study arms

  • Other
    Conventional Dentures

    Participants will first receive conventionally fabricated dentures for both the upper and lower jaws. This set will be made using traditional techniques, including impressions, a custom tray, jaw relation recording, try-in, and final fitting. After the washout period, they will receive a second set created with the 3D-printed technique.

    Device: Digital Occlusal Analysis Device

  • Other
    Digital Dentures

    Complete dentures fabricated with digital workflow, including intraoral scanning, CAD/CAM design, and 3D printing, followed by clinical fitting.

    Device: Digital Occlusal Analysis Device

Interventions

  • DeviceDigital Occlusal Analysis Device

    Computerized occlusal analysis performed using T-Scan and ModJaw devices to record occlusal contacts, timing, and force distribution during prosthesis fitting and function.

06

What researchers measure

Primary outcomes

  1. Occlusal Force Distribution and Contact Accuracy

    Quantitative assessment of occlusal contact number, area, timing, and force distribution in digital versus conventional complete dentures, measured using T-Scan and ModJaw systems, and validated against articulating paper marks.

    Time frame: 12 months

Secondary outcomes

  1. Oral Health-Related Quality of Life (OHRQoL)

    Change in Oral Health Impact Profile (OHIP-14) total scores between digital and conventional dentures, reflecting impact on comfort, function, and psychosocial well-being.

    Time frame: 12 months

Other outcomes

  1. Clinical Time Efficiency

    Mean chairside time (in minutes) required for each clinical step, including impressions, jaw relation recording, try-in, and final insertion.

    Time frame: 12 months

07

Study locations

No study locations are listed for this record.

08

References and documents

Publications

  • McKenna G, Tsakos G, Burke F, Brocklehurst P. Managing an Ageing Population: Challenging Oral Epidemiology. Prim Dent J. 2020 Sep;9(3):14-17. doi: 10.1177/2050168420943063. PubMed 32940594 ↗
  • Muller F. Interventions for edentate elders--what is the evidence? Gerodontology. 2014 Feb;31 Suppl 1:44-51. doi: 10.1111/ger.12083. PubMed 24446979 ↗
  • Qadeer S, Kerstein R, Kim RJ, Huh JB, Shin SW. Relationship between articulation paper mark size and percentage of force measured with computerized occlusal analysis. J Adv Prosthodont. 2012 Feb;4(1):7-12. doi: 10.4047/jap.2012.4.1.7. Epub 2012 Feb 29. PubMed 22439094 ↗
  • Gerritsen AE, Allen PF, Witter DJ, Bronkhorst EM, Creugers NH. Tooth loss and oral health-related quality of life: a systematic review and meta-analysis. Health Qual Life Outcomes. 2010 Nov 5;8:126. doi: 10.1186/1477-7525-8-126. PubMed 21050499 ↗

Individual participant data

Plan to share: No — confidentiality

09

Timeline

Tracking since Sep 25, 2026
ElapsedEstimatedEstimated, not yet reached

Start is estimated for Sep 2025; primary completion for Dec 2027, 27 months later.

How these figures are worked out, and which studies are left out of them.

Registered
Jul 28, 2025
First posted
Sep 9, 2025
StartEst.
Sep 15, 2025
Primary completionEst.
Dec 31, 2027
CompletionEst.
Dec 31, 2027
Last update
Sep 9, 2025
What these dates mean
Start.
When the first participant enrolled; while estimated, when the study expects to open to recruitment.
Primary completion.
When the last participant was examined or treated to collect data for the study's main question, its primary outcome. A study that stopped early gives the date its data collection stopped.
Completion.
When the last participant's last visit took place, for every outcome, secondary ones and side effects included: the end of the study. Often later than primary completion, sometimes the same day.
Actual and Est.
Actual means the registry says the date has happened. Est. (estimated) is a date the sponsor plans or expects. It can still move, and the sponsor is expected to change it to actual once it has passed.
No changes since tracking began. The registry record was last updated on Sep 9, 2025, before this site started recording changes on Sep 25, 2026. Its history is on ClinicalTrials.gov ↗
10

Registry details

Key details

Study ID
NCT07164066
Lead sponsor
Mohammed Bin Rashid University of Medicine and Health Sciences
Responsible party
May Al Janahi (Prosthodontist, Mohammed Bin Rashid University of Medicine and Health Sciences) — Principal investigator
First posted
Sep 9, 2025
Start date
Sep 15, 2025 (estimated)
Primary completion
Dec 31, 2027 (estimated)
Completion
Dec 31, 2027 (estimated)
Last update
Sep 9, 2025

Study contacts

May Al Janahi, Dclident
Contact
may.aljanahi@dubaihealth.ae
+971507190034
Haitham Elbishari, PhD
Contact
helbishari@gmail.com
+9714383 ext. 8911
Haitham Elbishari, PhD
principal investigator · MBRU

Oversight

Data monitoring committee
No
FDA-regulated drug
No
FDA-regulated device
No
View the source record on ClinicalTrials.gov ↗

Not currently enrolling

This study is not yet recruiting, as verified in Sep 2025. You cannot join it, but the record below documents what was studied.

Follow this study

Get an email when the registry record changes — status, dates, results — or when someone posts here.

Sign in to follow

Discussion

Questions and observations about this study, from anyone following it. Not medical advice, and not a channel to the study team — their contact details are on the registry record.

Sign in to join the discussion. Reading takes no account; posting does. You choose a display name, and a pseudonym is the default.

Nothing here yet. If you are running this trial, taking part in it, or weighing whether to, this is the place to say so.

Start the discussion