ClinicalTrials.gg
RecruitingNCT07127471Updated Sep 9, 2026

Computer-Aided Water Exchange Colonoscopy With and Without Linked-Color Imaging for Detection of Clinically Significant Serrated Lesions

An interventional study of Water exchange with AI-assisted detection and Water exchange with AI-assisted detection and LCI in Sessile Colonic Polyp, Serrated Lesion and Sessile Serrated Lesion, sponsored by Evergreen General Hospital, Taiwan. Recruiting at 4 sites in 4 countries. Open to participants aged 40 Years to 80 Years, including healthy volunteers. Per ClinicalTrials.gov, last updated 2026-09-09.

Sponsored by Evergreen General Hospital, Taiwan · Not applicable, Interventional, and Screening

From the registry’s dates

  • Started Nov 2025; still recruiting 11 months later.
Phase
Not applicable
Study type
Interventional
Enrollment
1,090
Allocation
Randomized
Ages
40 Years to 80 Years
Sex
All
01

Study summary

The goal of this clinical trial is to compare the detection rate of clinically significant serrated lesions (CSSL) in participants undergoing water exchange (WE) colonoscopy with artificial intelligence (AI)-based computer-aided detection (CADe) for screening, surveillance, diagnosis for symptoms, or referred owing to a positive fecal immunochemical test (FIT) or guaiac fecal occult blood test (gFOBT) result. There will be two arms in this study: WE with AI-assisted CADe (WEAID) control and WEAID plus linked-color imaging (LCI). The main question it aims to answer is whether the addition of LCI into WEAID colonoscopy increases CSSL detection rate. Both groups use water instead of air to insert the colonoscope into the cecum. The control method uses CADe to help detect colonic lesions. The study method uses a combination of CADe and LCI to detect lesions. Researchers will compare CSSL detection rate to see if the addition of LCI increases the detection of CSSL during CADe-assisted WE colonoscopy.

Read the detailed description

This will be a multicenter, unblinded investigators, prospective randomized controlled trial (RCT). Randomization (1:1 to WEAID alone and WEAID plus LCI) will be based on computer generated random numbers placed inside opaque sealed envelopes. The envelope (in pre-arranged order) will be opened to reveal the code when the colonoscopist is ready to insert the endoscope to begin the examination. This will be a comparison of two different methods with two arms (WEAID, WEAID-LCI) to see which one is better at detecting CSSL.

Patient recruitment will be conducted at 4 hospitals: University of Montreal Medical Center (CHUM), Quebec, Canada; Evergreen General Hospital, Taoyuan, Taiwan; King Chulalongkorn Memorial Hospital, Bangkok, Thailand; and Ospedale Valduce, Como, Italy. The study period is expected to be 2 years (from August 2025 to July 2027).

Patients aged 40-80 y/o at average risk of colorectal cancer who are willing to participate will sign an informed consent before starting the colonoscopy procedure. Separate parallel randomization will be set up at each site, stratified by investigator and indication of colonoscopy (screening, surveillance, diagnostic, or positive FIT or gFOBT result). Mode of sedation will include no sedation, on-demand sedation, conscious sedation or full sedation with propofol. Randomization will be carried out by computer-generated sequences.

The study employs standard high-definition colonoscopy video processors with integrated CADe system (CAD-EYE, EW10-EC02, Fujifilm). The ELUXEO 7000 system (Fujifilm) will be used. The same endoscopist performs the insertion and withdrawal of colonoscopy. The colonoscope will be inserted with WE method, instead of air insufflation. WE involves simultaneous infusion of distilled water to facilitate luminal expansion and suction of unclean water.

Control Method: One arm of the study will include CADe as the control method. The CADe system will be activated during the withdrawal phase of the procedures, and it will provide real-time output in the form of a bounding box whenever the CADe device identifies a suspected polyp.

Study method: The other arm entails the addition of a commercially available image-enhanced LCI technique (Fujifilm) to the CADe system. LCI will be activated during the withdrawal phase to enhance visualization of the lesions.

02

Conditions studied

  • Sessile Colonic Polyp
  • Serrated Lesion
  • Sessile Serrated Lesion
  • Colon Adenomas

Browse trials for

03

In context

Colonic Polyps

377 studies on the registry are indexed under Colonic Polyps; 57 are open to participants now.

This study's planned enrollment of 1,090 is above the median of 274 across 250 interventional studies indexed under Colonic Polyps.

Browse Colonic Polyps studies →

Lead sponsor

Evergreen General Hospital, Taiwan is the lead sponsor of 11 studies on the registry; 2 are open to participants now.

Counted across the registry records on this site, refreshed daily.

04

Who can participate

Ages eligible
40 Years to 80 Years
Sexes eligible
All
Accepts healthy volunteers
Yes

Go through the criteria one by one — yes, no or not sure — and take the list to your doctor or the study team. Kept in this browser only.

Inclusion criteria

  • Male and female patients aged 40-80 years scheduled for average-risk screening colonoscopy, post-polypectomy surveillance, diagnosis for gastrointestinal symptoms (including unexplained iron deficiency anemia and diarrhea of unexplained origin), or referred for colonoscopy owing to a positive fecal immunochemical test (FIT) or guaiac fecal occult blood test (gFOBT) result.

Exclusion criteria

Exclusion Criteria:

  • familial adenomatous polyposis and hereditary non-polyposis CRC syndrome
  • personal history of serrated polyposis syndrome
  • personal history of CRC
  • history of inflammatory bowel disease
  • previous colonic resection
  • overt gastrointestinal bleeding
  • emergency colonoscopy or inpatients
  • planned EMR or ESD of large polyps
  • colon stricture or obstruction
  • to colonoscopy (eg, acute diverticulitis or toxic megacolon)
  • antithrombotic therapy precluding complete polyp resection
  • American Society of Anesthesiology classification of physical status >3
  • pregnant women or women planning pregnancy
  • refusal to provide a written
Terms in these criteria, in plain language(3)

Underlined terms in the criteria open these too. Explained by clinicaltrials.gg, not part of the registry record. The study team decides who can take part.

Clinically significant

Judged by the study doctor to matter for your health or for the study. It is a doctor’s decision, so ask the study team if you are unsure whether something counts.

Contraindication

A reason a treatment, test or procedure should not be given to a particular person, such as an allergy, another illness or a medicine they take.

Informed consent

Before you join, the study team explains what taking part involves — its purpose, what happens, the risks and possible benefits — and answers your questions, so you can decide freely. Consent is usually recorded on a form (the informed consent form, ICF) signed by you or, where the law allows, by someone legally authorised to decide for you.

You can keep asking questions during the study, you are told of new information that matters, and you can choose to leave at any time.

05

Study design

Phase
Not applicable
Primary purpose
Screening
Allocation
Randomized
Intervention model
Parallel assignment
Masking
Double (Participant, Outcomes assessor)
Enrollment
1,090 participants (estimated)

Study arms

  • Active comparator
    Water exchange with AI-assisted detection

    The study employs standard high-definition colonoscopy video processors with integrated CADe system (CAD-EYE, EW10-EC02, Fujifilm) The ELUXEO 7000 system (Fujifilm) will be used in this study. During the insertion phase of water exchange (WE) colonoscopy, the air pump will be turned off, and the colon will be irrigated with warm water, using a flushing pump. WE involves simultaneous infusion of distilled water to facilitate luminal expansion and suction of unclean water. Withdrawal will begin with the patient in the left lateral position. Consistent techniques, ensuring adequate luminal distention and comprehensive fold examination, will be used. The CADe device will be activated during the withdrawal phase of the procedures, and it will provide real-time output in the form of a bounding box whenever the CADe device identifies a suspected polyp. All participating endoscopists possess experience and expertise in CADe systems, ensuring readiness before study initiation.

    Device: Water exchange with AI-assisted detection

  • Experimental
    Water exchange with AI-assisted detection and LCI

    The study employs high-definition colonoscopy video processors with integrated CADe (CAD-EYE, EW10-EC02, Fujifilm) and LCI systems (Fujifilm).The ELUXEO 7000 system will be used . During the insertion phase of water exchange (WE) colonoscopy, the air pump will be turned off, and the colon will be irrigated with warm water, using a flushing pump. WE involves simultaneous infusion of distilled water to facilitate luminal expansion and suction of unclean water. Withdrawal will begin with the patient in the left lateral position. Consistent techniques, ensuring adequate luminal distention and comprehensive fold examination, will be used. The CADe and LCI devices will be activated during the withdrawal phase of the procedures, and it will provide real-time output in the form of a bounding box whenever the CADe device identifies a suspected polyp. All participating endoscopists possess experience and expertise in CADe and LCI systems, ensuring readiness before study initiation.

    Device: Water exchange with AI-assisted detection and LCI

Interventions

  • DeviceWater exchange with AI-assisted detection

    The study employs standard high-definition colonoscopy video processors with integrated CADe system (CAD-EYE, EW10-EC02, Fujifilm) The ELUXEO 7000 system (Fujifilm) will be used in this study. During the insertion phase of water exchange (WE) colonoscopy, the air pump will be turned off, and the colon will be irrigated with warm water, using a flushing pump. WE involves simultaneous infusion of distilled water to facilitate luminal expansion and suction of unclean water. Withdrawal will begin with the patient in the left lateral position. Consistent techniques, ensuring adequate luminal distention and comprehensive fold examination, will be used. The CADe device will be activated during the withdrawal phase of the procedures, and it will provide real-time output in the form of a bounding box whenever the CADe device identifies a suspected polyp. All participating endoscopists possess experience and expertise in CADe systems, ensuring readiness before study initiation.

  • DeviceWater exchange with AI-assisted detection and LCI

    The study employs high-definition colonoscopy video processors with integrated CADe (CAD-EYE, EW10-EC02, Fujifilm) and LCI systems (Fujifilm).The ELUXEO 7000 system will be used . During the insertion phase of water exchange (WE) colonoscopy, the air pump will be turned off, and the colon will be irrigated with warm water, using a flushing pump. WE involves simultaneous infusion of distilled water to facilitate luminal expansion and suction of unclean water. Withdrawal will begin with the patient in the left lateral position. Consistent techniques, ensuring adequate luminal distention and comprehensive fold examination, will be used. The CADe and LCI devices will be activated during the withdrawal phase of the procedures, and it will provide real-time output in the form of a bounding box whenever the CADe device identifies a suspected polyp. All participating endoscopists possess experience and expertise in CADe and LCI systems, ensuring readiness before study initiation.

06

What researchers measure

Primary outcomes

  1. Clinically significant serrated lesion (CSSL) detection rate

    Percentage of patients who have 1 or more histologically confirmed CSSLs, including sessile serrated lesions, traditional serrated adenomas, hyperplastic polyps measuring ≥10 mm anywhere in the colon, or hyperplastic polyps measuring 6-9 mm in the proximal colon (cecum to splenic flexure).

    Time frame: One week (after the colonoscopy procedure, when pathology report is released)

Secondary outcomes

  1. Sessile serrated lesion (SSL) detection rate

    Percentage of patients who have 1 or more histologically confirmed SSL with or without dysplasia.

    Time frame: One week (after the colonoscopy procedure, when pathology report is released)

  2. Proximal serrated lesion detection rate

    Percentage of patients who have 1 or more histologically confirmed proximal serrated lesions, including sessile serrated lesion, translational serrated adenoma, and hyperplastic polyp. The proximal colon includes the cecum, ascending colon, hepatic flexure, transverse colon, and splenic flexure.

    Time frame: One week (after the colonoscopy procedure, when pathology report is released)

  3. High-risk neoplasm detection rate

    Percentage of patients who have 1 or more histologically confirmed advanced adenoma, or ≥5 low-risk adenomas (defined as 1 to 2 tubular adenomas \<10 mm with low-grade dysplasia), or any serrated lesions ≥10 mm or with dysplasia. Advanced adenomas are defined as those adenomas meeting at least one of the following criteria: (1) size ≥10 mm, (2) presence of 25% villous components, and (3) high-grade dysplasia.

    Time frame: One week (after the colonoscopy procedure, when pathology report is released)

  4. Adenoma detection rate

    Percentage of patients who have 1 or more histologically confirmed conventional adenomas.

    Time frame: One week (after the colonoscopy procedure, when pathology report is released)

  5. Adenoma per colonoscopy

    Total number of histologically confirmed adenomas divided by the total number of colonoscopies.

    Time frame: One week (after the colonoscopy procedure, when pathology report is released)

07

Study locations

1 of 4 sites recruiting
  • University of Montreal Medical Center (CHUM)
    Montreal, Quebec H2X 0A9, Canada
    Not yet recruiting
    • Daniel von Renteln, MD · Contactdaniel.von.renteln.med@ssss.gouv.qc.ca · 5148908000
    • Roupen Djinbachian, MD · Sub investigator
    • Simon Bouchard, MD · Sub investigator
    • Jeremy Liu Chen Kiow, MD · Sub investigator
    • Daniel von Renteln, MD · Principal investigator
  • Ospedale Valduce
    Como, 22100, Italy
    Not yet recruiting
  • Evergreen General Hospital
    Taoyuan, 320, Taiwan
    Recruiting
    • Chi-Liang Cheng, MD · Contactchiliang.cheng@gmail.com · 0919768058
    • Yen-Lin Kuo, MD · Sub investigator
    • I-Chia Su, MD · Sub investigator
    • Chi-Liang Cheng, MD · Principal investigator
  • King Chulalongkorn Memorial Hospital
    Bangkok, 10330, Thailand
    Not yet recruiting
    • Rungsun Rerknimitr, MD · ContactERCP@live.com · +66 81 902 6633
    • Piyapoom Pakvisal, MD, Msc · Sub investigator
    • Krittaya Mekritthikrai, MD · Sub investigator
    • Rungsun Rerknimitr, MD · Principal investigator
08

References and documents

Publications

  • Anderson JC, Hisey W, Mackenzie TA, Robinson CM, Srivastava A, Meester RGS, Butterly LF. Clinically significant serrated polyp detection rates and risk for postcolonoscopy colorectal cancer: data from the New Hampshire Colonoscopy Registry. Gastrointest Endosc. 2022 Aug;96(2):310-317. doi: 10.1016/j.gie.2022.03.001. Epub 2022 Mar 8. PubMed 35276209 ↗
  • Anderson JC, Rex DK, Mackenzie TA, Hisey W, Robinson CM, Butterly LF. Higher Serrated Polyp Detection Rates Are Associated With Lower Risk of Postcolonoscopy Colorectal Cancer: Data From the New Hampshire Colonoscopy Registry. Am J Gastroenterol. 2023 Nov 1;118(11):1927-1930. doi: 10.14309/ajg.0000000000002403. Epub 2023 Jul 7. PubMed 37417792 ↗

Individual participant data

Plan to share: No

09

Updates

Tracking since Sep 25, 2026
No changes since tracking began. The registry record was last updated on Sep 9, 2026, before this site started recording changes on Sep 25, 2026. Its history is on ClinicalTrials.gov ↗
10

Registry details

Key details

Study ID
NCT07127471
Lead sponsor
Evergreen General Hospital, Taiwan
Collaborators
Centre hospitalier de l'Université de Montréal (CHUM), King Chulalongkorn Memorial Hospital, Valduce Hospital
Responsible party
Sponsor
First posted
Aug 17, 2025
Start date
Nov 17, 2025
Primary completion
Sep 30, 2027 (estimated)
Completion
Dec 31, 2027 (estimated)
Last update
Sep 9, 2026

Study contacts

Chi-Liang Cheng, MD
Contact
chiliang.cheng@gmail.com
+886 919 768058
Rungsun Rerknimitr, MD
Contact
ERCP@live.com
+66 81 902 6633
Chi-Liang Cheng, MD
study chair · Evergreen General Hospital, Taoyuan
Rungsun Rerknimitr, MD
principal investigator · Center of Excellence for Innovation and Endoscopy in Gastrointestinal Oncology, King Chulalongkorn Memorial Hospital
Daniel von Renteln, MD
principal investigator · Research, Gastroenterology Division, University of Montreal Medical Center (CHUM)
Franco Radaelli, MD
principal investigator · Gastroenterology Unit, Ospedale Valduce

Oversight

Data monitoring committee
No
FDA-regulated drug
No
FDA-regulated device
No
View the source record on ClinicalTrials.gov ↗

Interested in this study?

Eligibility is decided by the study team. Share this record with your doctor or contact the team directly.

Contact study team

Follow this study

Get an email when the registry record changes — status, dates, results — or when someone posts here.

Sign in to follow

Discussion

Questions and observations about this study, from anyone following it. Not medical advice, and not a channel to the study team — their contact details are on the registry record.

Sign in to join the discussion. Reading takes no account; posting does. You choose a display name, and a pseudonym is the default.

Nothing here yet. If you are running this trial, taking part in it, or weighing whether to, this is the place to say so.

Start the discussion