An interventional study of Venus-Vitae Transcatheter Heart Valve System in Aortic Valve Stenosis, sponsored by Venus MedTech (HangZhou) Inc.. Not yet recruiting. Open to participants aged 18 Years and older. Per ClinicalTrials.gov, last updated 2023-08-18.
Sponsored by Venus MedTech (HangZhou) Inc. · Not applicable, Interventional, and Treatment
Help build ClinicalTrials.gg — short surveys, remote interviews or testing, in your language. Take part →
The purpose is to evaluate the safety, effectiveness and performance of Venus-Vitae Transcatheter Heart Valve System in patients with severe aortic stenosis.
This trial is a prospective, multi-center, non-randomized interventional study to evaluate the safety, effectiveness and performance of the Venus-Vitae Transcatheter Heart Valve System in patients with severe aortic stenosis. Clinical visits will be scheduled at screening, pre-discharge, 30 days, 6 months, 12 months and annually thereafter to 5 years.
1,028 studies on the registry are indexed under Aortic Valve Stenosis; 295 are open to participants now.
This study's planned enrollment of 150 is above the median of 126 across 555 interventional studies indexed under Aortic Valve Stenosis.
Browse Aortic Valve Stenosis studies →Venus MedTech (HangZhou) Inc. is the lead sponsor of 7 studies on the registry; 4 are open to participants now.
Counted across the registry records on this site, refreshed daily.
Go through the criteria one by one — yes, no or not sure — and take the list to your doctor or the study team. Kept in this browser only.
Exclusion Criteria:
A subject meeting any of the following criteria shall be excluded:
Co-morbidities
Underlined terms in the criteria open these too. Explained by clinicaltrials.gg, not part of the registry record. The study team decides who can take part.
Before you join, the study team explains what taking part involves — its purpose, what happens, the risks and possible benefits — and answers your questions, so you can decide freely. Consent is usually recorded on a form (the informed consent form, ICF) signed by you or, where the law allows, by someone legally authorized to decide for you.
You can keep asking questions during the study, you are told of new information that matters, and you can choose to leave at any time.
A “mini-stroke”: temporary stroke-like symptoms caused by reduced blood flow to part of the brain, spinal cord or eye, without signs of a new stroke on a scan.
Stroke symptoms need emergency care at once, even if they go away.
GFR (glomerular filtration rate) is how much blood the kidneys filter each minute. It is usually estimated from a blood test — eGFR, by formulas such as CKD-EPI or MDRD — and some studies ask for it to be measured directly instead. Usually given in mL/min/1.73 m².
Check the method, the units and the minimum the study states. A value of 90 or above is in the normal-or-high range, but kidney damage can show in other tests too.
The protein in red blood cells that carries oxygen. A low level is anemia, which can cause tiredness and breathlessness. Measured in g/dL or g/L (9 g/dL is 90 g/L).
Judged by the study doctor to matter for your health or for the study. It is a doctor’s decision, so ask the study team if you are unsure whether something counts.
The share of blood the heart’s main pumping chamber (the left ventricle) pushes out with each beat, measured by an echocardiogram (heart ultrasound) or a MUGA scan. About 50–70% is normal.
An allergy, or another reaction of the immune system, to a substance. “Hypersensitivity to the study drug” means a known allergic reaction to it — not every side effect a medicine can have.
A reason a treatment, test or procedure should not be given to a particular person, such as an allergy, another illness or a medicine they take.
The study doctor’s estimate of how long someone is likely to live. Criteria use it so that people can stay in the study long enough for it to answer its question.
Informed consent
Before you join, the study team explains what taking part involves — its purpose, what happens, the risks and possible benefits — and answers your questions, so you can decide freely. Consent is usually recorded on a form (the informed consent form, ICF) signed by you or, where the law allows, by someone legally authorized to decide for you.
You can keep asking questions during the study, you are told of new information that matters, and you can choose to leave at any time.
Explained by clinicaltrials.gg, not part of the registry record. The study team decides who can take part.
TIA (transient ischaemic attack)
A “mini-stroke”: temporary stroke-like symptoms caused by reduced blood flow to part of the brain, spinal cord or eye, without signs of a new stroke on a scan.
Stroke symptoms need emergency care at once, even if they go away.
Explained by clinicaltrials.gg, not part of the registry record. The study team decides who can take part.
GFR and eGFR (kidney filtering)
GFR (glomerular filtration rate) is how much blood the kidneys filter each minute. It is usually estimated from a blood test — eGFR, by formulas such as CKD-EPI or MDRD — and some studies ask for it to be measured directly instead. Usually given in mL/min/1.73 m².
Check the method, the units and the minimum the study states. A value of 90 or above is in the normal-or-high range, but kidney damage can show in other tests too.
Explained by clinicaltrials.gg, not part of the registry record. The study team decides who can take part.
Hemoglobin (Hb)
The protein in red blood cells that carries oxygen. A low level is anemia, which can cause tiredness and breathlessness. Measured in g/dL or g/L (9 g/dL is 90 g/L).
Explained by clinicaltrials.gg, not part of the registry record. The study team decides who can take part.
Clinically significant
Judged by the study doctor to matter for your health or for the study. It is a doctor’s decision, so ask the study team if you are unsure whether something counts.
Explained by clinicaltrials.gg, not part of the registry record. The study team decides who can take part.
LVEF (left ventricular ejection fraction)
The share of blood the heart’s main pumping chamber (the left ventricle) pushes out with each beat, measured by an echocardiogram (heart ultrasound) or a MUGA scan. About 50–70% is normal.
Explained by clinicaltrials.gg, not part of the registry record. The study team decides who can take part.
Hypersensitivity
An allergy, or another reaction of the immune system, to a substance. “Hypersensitivity to the study drug” means a known allergic reaction to it — not every side effect a medicine can have.
Explained by clinicaltrials.gg, not part of the registry record. The study team decides who can take part.
Contraindication
A reason a treatment, test or procedure should not be given to a particular person, such as an allergy, another illness or a medicine they take.
Explained by clinicaltrials.gg, not part of the registry record. The study team decides who can take part.
Life expectancy
The study doctor’s estimate of how long someone is likely to live. Criteria use it so that people can stay in the study long enough for it to answer its question.
Explained by clinicaltrials.gg, not part of the registry record. The study team decides who can take part.
implant valve by TAVR
Device: Venus-Vitae Transcatheter Heart Valve System
The Venus-Vitae THV is comprised of balloon-expandable and radiopaque cobalt-chromium alloy frame, porcine pericardium tri-leaflet, porcine pericardium inner skirt, polyurethane outer skirt, PTFE assembly sutures, and three radiopaque gold markers (Figure 1). The valve utilizes Venus Endura technology and stored in a non-aqueous condition.
The rate of deaths at the one-year follow-up visit post procedure
All-cause mortality (The rate of deaths at the one-year follow-up visit post procedure)
Time frame: 1 Years
Acceptable Hemodynamic Performance at 30 days
Acceptable Bio-prosthesis Hemodynamic Performance at 30 days, defined as: * Mean gradient \< 20mmHg * Less than moderate aortic regurgitation (perivalvular and transvalvular)
Time frame: 30 Days
Occurrence of the following adverse events echocardiogram during follow-up
Occurrence of the following adverse events echocardiogram during follow-up (The rate of follow events during the follow-up) * All-cause mortality * All stroke * Life-threatening bleeding * Acute MI * Heart failure hospitalizations * New permanent pacemaker implantation * Major vascular complication * Acute kidney injury * Aortic valve re-intervention (surgical or transcatheter) * Valve thrombosis * Structural valve deterioration
Time frame: 5 Years
Technical success is defined as the following
Technical success (at exit from procedure room) (VARC-3\[1\]) (The rate of Technical success at the Procedure) * Freedom from mortality * Successful access, delivery of the device, and retrieval of the delivery system * Correct positioning of a single prosthetic heart valve into the proper anatomical location * Freedom from surgery or intervention related to the device or a major vascular or access-related, or cardiac structural complication
Time frame: During the Procedure
The rate of device success is defined as the following
Device success (in-hospital) (VARC-3\[1\]) (The rate of device success during the in-hospital) * Freedom from mortality * Freedom from surgery or intervention related to the device or a major vascular or access-related or cardiac structural complication * Intended performance of the valve (mean gradient \< 20 mmHg, peak velocity \<3 m/s, and less than moderate aortic regurgitation)
Time frame: Up to 1 week
The rate of acceptable valve function at pre-discharge by echocardiogram defined as the following:
Acceptable valve function at pre-discharge by echocardiogram (The rate of follow events during the follow-up) * Freedom from moderate or greater patient-prosthesis mismatch (PPM) * MPG \<20mmHg * Freedom from moderate or greater regurgitation (transvalvular and paravalvular) * Freedom from reoperation or intervention
Time frame: Up to 1 week
The rate of freedom from severe coronary overlap assessed by post-implant angiogram
Freedom from severe coronary overlap assessed by post-implant angiogram
Time frame: immediately after the procedure
The rate of freedom from mild or greater commissure misalignment assessed by post-implant angiogram and/or 30-day CT
Freedom from mild or greater commissure misalignment assessed by post-implant angiogram and/or 30-day CT (post-implant 30-day CT scan is not mandatory for each subjects)
Time frame: 30-Days
The rate of freedom from mild or greater PVL by echocardiogram during follow-up
Freedom from mild or greater PVL by echocardiogram during follow-up
Time frame: 5 Years
New York Heart Association (NYHA) classification during follow-up
New York Heart Association (NYHA) classification during follow-up
Time frame: 5 Years
No study locations are listed for this record.
Plan to share: No
No publications or documents are linked to this record.
Start is estimated for Oct 2023; primary completion for Dec 2024, 14 months later.
Of 111 industry-sponsored interventional studies with no phase under Aortic Valve Stenosis, half reached primary completion within 29 months of starting (the median), counting those still running; a quarter within 16 and three quarters within 54. This study's planned 14 months is below that.
Counting every sponsor, half of 288 studies reached it within 33 months; a quarter within 18 and three quarters within 71.
How these figures are worked out, and which studies are left out of them.
This study is not yet recruiting, as verified in Aug 2023. You cannot join it, but the record below documents what was studied.
Get an email when the registry record changes — status, dates, results — or when someone posts here.
Sign in to followQuestions and observations about this study, from anyone following it. Not medical advice, and not a channel to the study team — their contact details are on the registry record.
Sign in to join the discussion. Reading takes no account; posting does. You choose a display name, and a pseudonym is the default.
Nothing here yet. If you are running this trial, taking part in it, or weighing whether to, this is the place to say so.