An observational study in Surgery, sponsored by Brittany Willer. Withdrawn at 1 site in United States. Open to participants aged 2 Years to 9 Years. Per ClinicalTrials.gov, last updated 2026-09-14.
Sponsored by Brittany Willer · Observational
Help build ClinicalTrials.gg — short surveys, remote interviews or testing, in your language. Take part →
This is a prospective, non-randomized, non-blinded comparative study to evaluate the accuracy of pulse oximetry compared to co-oximetry in dark-skinned (Black) compared to lighter-skinned (White) children undergoing anesthesia, using standard FDA performance statistics as measured by mean bias and accuracy root mean squared to evaluate device performance.
This is a prospective, non-randomized, non-blinded comparative study.
There will be no changes to the anesthetic or surgical plan to accommodate this study. Patients undergoing anesthesia will be induced per their anesthetic team. Following endotracheal intubation, the patient will be placed on air (FiO2 21%) at 4 liters per minute fresh gas flow. After a minimum of 3 minutes has elapsed, the anesthesia team will obtain an arterial blood sample of approximately 1 mL. This can be obtained from an arterial line if one is planned for the procedure or already in place by accessing the line per standard procedure. If an arterial line is not placed, the arterial sample will be obtained by percutaneous arterial puncture using ultrasound guidance and a 25-gauge blood gas syringe. The patient's SpO2 will be noted using a pulse oximetry probe placed on the right index finger when the arterial sample is drawn, along with the date/time of sample acquisition. Once the sample is drawn, the patient's anesthetic and surgery will proceed as per his anesthesia team. The arterial sample will be immediately delivered to the Nationwide Children's Hospital laboratory for simultaneous ABG and ABG-CoOx analysis to obtain SaO2S and SaO2C, respectively.
Brittany Willer is the lead sponsor of 5 studies on the registry; 4 are open to participants now.
Counted across the registry records on this site, refreshed daily.
Children undergoing surgery at Nationwide Children's Hospital.
Go through the criteria one by one — yes, no or not sure — and take the list to your doctor or the study team. Kept in this browser only.
Exclusion Criteria:
1 mL blood sample for ABG-CoOx analysis to obtain co-oximetry measured arterial oxygen saturation (SaO2C) and standard ABG derived arterial oxygen saturation (SaO2S).
Also known as: ABG-CoOx
Accuracy of Pulse Oximetry
Accuracy of pulse oximetry readings (SpO2) as compared with arterial oxygen saturations measured by arterial blood gas with co-oximetry (ABG-CoOx).
Time frame: Baseline
Plan to share: No
No publications or documents are linked to this record.
Start is estimated for Jul 2026; primary completion for Dec 2027, 17 months later.
How these figures are worked out, and which studies are left out of them.
This study is withdrawn, as verified in Sep 2026. You cannot join it, but the record below documents what was studied.
Get an email when the registry record changes — status, dates, results — or when someone posts here.
Sign in to followQuestions and observations about this study, from anyone following it. Not medical advice, and not a channel to the study team — their contact details are on the registry record.
Sign in to join the discussion. Reading takes no account; posting does. You choose a display name, and a pseudonym is the default.
Nothing here yet. If you are running this trial, taking part in it, or weighing whether to, this is the place to say so.
Brittany Willer