An interventional study of SINOMED CBC and NSE Coronary Dilatation Catheter in Coronary Stenosis, Coronary Artery Stenosis and In-stent Restenosis, sponsored by Sino Medical Sciences Technology Inc.. Completed at 8 sites in China. Open to participants aged 18 Years to 75 Years. Per ClinicalTrials.gov, last updated 2026-03-27.
Sponsored by Sino Medical Sciences Technology Inc. · Not applicable, Interventional, and Treatment
Help build ClinicalTrials.gg — short surveys, remote interviews or testing, in your language. Take part →
Among 38 studies in Coronary Stenosis with a site in China — 8 open to participants now, 10 under way, 1 of them phase 3. Coronary Stenosis · China.
Among the 38 studies in Coronary Stenosis with a site in China, this one is the 21st largest by enrollment of the 26 interventional ones that give a count, is one of 2 that started in 2022, is one of 16 with no phase, and was the 25th registered.
326 studies on the registry are indexed under Coronary Stenosis; 57 are open to participants now.
Browse Coronary Stenosis studies →8 of the 38 studies in Coronary Stenosis with a site in China are open now. Recruiting first, the newest first:
China National Center for Cardiovascular Diseases · Sites in China
Ages 18+
Peking Union Medical College Hospital · Sites in China
Ages 18+
China National Center for Cardiovascular Diseases · Sites in China
Ages 18–70
Duk-Woo Park, MD · Sites in China, United States, Australia and 11 more countries
Ages 20+
Xijing Hospital · Sites in China
Ages 18+
A study can be open while its sites in China have not opened yet or have stopped. Only those recruiting at a site in China →
Of the 40 Coronary Stenosis studies recruiting now, 33 (83%) set no upper age limit and 3 (8%) stop at 75 or younger; 4 take children under 18; 2 take healthy volunteers.
This study: 18 Years to 75 Years · all sexes · no healthy volunteers.
The full table on the hub →This tab as a report to print or save as PDF → With an account.
38 studies; the count open now beside each. This study's row is marked.
First in 2004; this study’s year is marked. 2 started in 2022.
This study's enrollment of 136 is below the median of 190 across 191 interventional studies indexed under Coronary Stenosis.
Median enrollment 270 across the 26 interventional studies, 161 across the 12 observational. Of the 16 that completed or were terminated, 3 (19%) have results posted.
This tab as a report to print or save as PDF → With an account.
19 of 38 have an industry lead sponsor. The 10 most frequent:
Sino Medical Sciences Technology Inc. is the lead sponsor of 13 studies on the registry; 1 is open to participants now.
Sino Medical Sciences Technology Inc. has 1 study filed under Coronary Stenosis — fewer than ten, so there is no comparison to draw.
2 of the studies in Coronary Stenosis with a site in China that are under way reach primary completion within a year, 0 of them phase 3. Phase 3 first, then by date:
| Study | Primary completion |
|---|---|
| NCT06845410Peking Union Medical College HospitalClinical Features, Current Treatment and Clinical Outcomes in Patients With INR-CAD: a Cohort Study | 2026-12 |
| NCT07660419China National Center for Cardiovascular DiseasesEffect of Mobile-Based Home Cardiac Rehabilitation on Coronary Plaque | 2026-12-31 |
Add all 2 to your calendar (.ics) → With an account.
Among the 38 studies in Coronary Stenosis with a site in China, from their registry updates:
This tab as a report to print or save as PDF → With an account.
The objective of this study is to evaluate safety and effectiveness of the SINOMED CBC coronary dilatation catheter during PCI in subjects with stenotic coronary arteries.
The investigation is a prospective, multi-center, randomized control, non-inferiority clinical study. The study will be conducted in up to 8 investigational sites in the China This study will enroll and treat 136 subjects, including in-stent restenosis (ISR). The population for this study is subjects with stenotic coronary artery disease who are suitable candidates for PTCA.
After screening for initial inclusion and exclusion criteria, eligible subjects will be asked to participate in the study by signing a consent form. Following consent, subjects will undergo a baseline visit where eligibility criteria will be assessed. Then, subjects will be randomized to either trial balloon (Sino Medical Sciences Technology Inc. ) or to a NSE Coronary Dilatation Catheter (Goodman Co.,Ltd). Angiograms will be performed before and after intervention.
Subjects will be followed through hospital discharge.
Go through the criteria one by one — yes, no or not sure — and take the list to your doctor or the study team. Kept in this browser only.
Exclusion Criteria:
Underlined terms in the criteria open these too. Explained by clinicaltrials.gg, not part of the registry record. The study team decides who can take part.
Before you join, the study team explains what taking part involves — its purpose, what happens, the risks and possible benefits — and answers your questions, so you can decide freely. Consent is usually recorded on a form (the informed consent form, ICF) signed by you or, where the law allows, by someone legally authorized to decide for you.
You can keep asking questions during the study, you are told of new information that matters, and you can choose to leave at any time.
The New York Heart Association’s four classes of how much heart failure limits physical activity.
Studies set their own limit — many outside heart failure leave out class III–IV, while heart failure studies may ask for a particular class. Check the class this study names.
The share of blood the heart’s main pumping chamber (the left ventricle) pushes out with each beat, measured by an echocardiogram (heart ultrasound) or a MUGA scan. About 50–70% is normal.
A reason a treatment, test or procedure should not be given to a particular person, such as an allergy, another illness or a medicine they take.
Blood cells that help blood clot. Too few raises the risk of bleeding and bruising. A usual adult range is about 150–400 × 10⁹/L (150,000–400,000 per µL); each lab has its own reference range.
Informed consent
Before you join, the study team explains what taking part involves — its purpose, what happens, the risks and possible benefits — and answers your questions, so you can decide freely. Consent is usually recorded on a form (the informed consent form, ICF) signed by you or, where the law allows, by someone legally authorized to decide for you.
You can keep asking questions during the study, you are told of new information that matters, and you can choose to leave at any time.
Explained by clinicaltrials.gg, not part of the registry record. The study team decides who can take part.
NYHA class (heart failure)
The New York Heart Association’s four classes of how much heart failure limits physical activity.
Studies set their own limit — many outside heart failure leave out class III–IV, while heart failure studies may ask for a particular class. Check the class this study names.
Explained by clinicaltrials.gg, not part of the registry record. The study team decides who can take part.
LVEF (left ventricular ejection fraction)
The share of blood the heart’s main pumping chamber (the left ventricle) pushes out with each beat, measured by an echocardiogram (heart ultrasound) or a MUGA scan. About 50–70% is normal.
Explained by clinicaltrials.gg, not part of the registry record. The study team decides who can take part.
Contraindication
A reason a treatment, test or procedure should not be given to a particular person, such as an allergy, another illness or a medicine they take.
Explained by clinicaltrials.gg, not part of the registry record. The study team decides who can take part.
Platelets
Blood cells that help blood clot. Too few raises the risk of bleeding and bruising. A usual adult range is about 150–400 × 10⁹/L (150,000–400,000 per µL); each lab has its own reference range.
Explained by clinicaltrials.gg, not part of the registry record. The study team decides who can take part.
Cutting balloon catheter (Sino Medical Sciences Technology Inc.)
Device: SINOMED CBC
NSE Coronary Dilatation Catheter (Goodman Co.,Ltd)
Device: NSE Coronary Dilatation Catheter
The Coronary Dilatation Balloon Catheter is indicated for the treatment of hemodynamically significant coronary artery stenosis, including in-stent restenosis and complex type C lesions, for the purpose of improving myocardial perfusion.
Also known as: cutting balloon catheter, scoring balloon catheter
The Coronary Dilatation Balloon Catheter is indicated for the treatment of hemodynamically significant coronary artery stenosis, including in-stent restenosis and complex type C lesions, for the purpose of improving myocardial perfusion.
Also known as: Lacrosse NSE
Number of Device Procedural Success(Lesions Level)
Defined as: Successful delivery, inflation, deflation, and withdrawal of the study balloon; and ≤30% final diameter stenosis following completion of the interventional procedure, including adjunctive stenting (For ISR or DCB related stenosis, Final diameter stenosis\<50%)
Time frame: immediate post-intervention(approximately 1.4 hour)
Number of Participants With Procedural Success (Patient Level)
Defined as: ≤30% final diameter stenosis following completion of the interventional procedure, including adjunctive stenting (For ISR or DCB related stenosis, Final diameter stenosis\<50%); and freedom from major adverse cardiac events (MACE) during hospitalization
Time frame: During the hospital stay, up to 1 week
Number of Participants Who Experienced Target Lesion Failure (TLF)
A composite of cardiac death, target vessel myocardial infarction, or clinically-driven target lesion revascularisation (CI-TLR)
Time frame: During the hospital stay, up to 1 week
Number of Participants Who Experienced Patient-oriented Composite Endpoint (POCE)
A composite of all-cause death, any stroke, any myocardial infarction, or any clinically, and physiologically driven revascularization
Time frame: During the hospital stay, up to 1 week
Number of Participants With Any Adverse Events (AE)
Report any AE results from a device deficiency or other device issue as related to the use of the study device. Such as Balloon burst、vascular perforation, dissection, acute occlusion, vasospasm, thrombosis (including stent thrombosis), arrhythmia requiring intervention, and so on.
Time frame: During the hospital stay, up to 1 week
Number of Device Defects
Report any device defect during hospitalization
Time frame: During the hospital stay, up to 1 week
Number of Participants With Serious Adverse Events (SAE)
Report any SAE results from a device deficiency or other device issue as related to the use of the study device. Such as Balloon burst、vascular perforation, dissection, acute occlusion, vasospasm, thrombosis (including stent thrombosis), arrhythmia requiring intervention, and so on.
Time frame: During the hospital stay, up to 1 week
| Milestone | SINOMED CBC | NSE Coronary Dilatation Catheter |
|---|---|---|
| Started | 67 | 69 |
| Completed | 66 | 68 |
| Not completed | 1 | 1 |
Defined as: Successful delivery, inflation, deflation, and withdrawal of the study balloon; and ≤30% final diameter stenosis following completion of the interventional procedure, including adjunctive stenting (For ISR or DCB related stenosis, Final diameter stenosis\<50%)
| lesions | SINOMED CBC | NSE Coronary Dilatation Catheter |
|---|---|---|
| Number of Device Procedural Success(Lesions Level) | 68 | 68 |
Defined as: ≤30% final diameter stenosis following completion of the interventional procedure, including adjunctive stenting (For ISR or DCB related stenosis, Final diameter stenosis\<50%); and freedom from major adverse cardiac events (MACE) during hospitalization
| Participants | SINOMED CBC | NSE Coronary Dilatation Catheter |
|---|---|---|
| Number of Participants With Procedural Success (Patient Level) | 65 | 65 |
A composite of cardiac death, target vessel myocardial infarction, or clinically-driven target lesion revascularisation (CI-TLR)
| Participants | SINOMED CBC | NSE Coronary Dilatation Catheter |
|---|---|---|
| Number of Participants Who Experienced Target Lesion Failure (TLF) | 0 | 0 |
A composite of all-cause death, any stroke, any myocardial infarction, or any clinically, and physiologically driven revascularization
| Participants | SINOMED CBC | NSE Coronary Dilatation Catheter |
|---|---|---|
| Number of Participants Who Experienced Patient-oriented Composite Endpoint (POCE) | 0 | 0 |
Report any AE results from a device deficiency or other device issue as related to the use of the study device. Such as Balloon burst、vascular perforation, dissection, acute occlusion, vasospasm, thrombosis (including stent thrombosis), arrhythmia requiring intervention, and so on.
| Participants | SINOMED CBC | NSE Coronary Dilatation Catheter |
|---|---|---|
| Number of Participants With Any Adverse Events (AE) | 21 | 18 |
Report any device defect during hospitalization
| Participants | SINOMED CBC | NSE Coronary Dilatation Catheter |
|---|---|---|
| Number of Device Defects | 0 | 0 |
Report any SAE results from a device deficiency or other device issue as related to the use of the study device. Such as Balloon burst、vascular perforation, dissection, acute occlusion, vasospasm, thrombosis (including stent thrombosis), arrhythmia requiring intervention, and so on.
| Participants | SINOMED CBC | NSE Coronary Dilatation Catheter |
|---|---|---|
| Number of Participants With Serious Adverse Events (SAE) | 1 | 1 |
Collected over During the hospital, up to 1 week. Non-serious events are listed at a 0% frequency threshold.
| Group | Deaths | Serious | Other |
|---|---|---|---|
| SINOMED CBC | 0/66 (0%) | 1/66 (1.5%) | 21/66 (31.8%) |
| NSE Coronary Dilatation Catheter | 0/68 (0%) | 1/68 (1.5%) | 18/68 (26.5%) |
| Event | SINOMED CBC | NSE Coronary Dilatation Catheter |
|---|---|---|
| Mesenteric arteriosclerosisVascular disorders | 1/66 | 0/68 |
| Cerebral infarctionNervous system disorders | 0/66 | 1/68 |
| Event | SINOMED CBC | NSE Coronary Dilatation Catheter |
|---|---|---|
| Myocardial injuryCardiac disorders | 6/66 | 5/68 |
| HypokalaemiaMetabolism and nutrition disorders | 3/66 | 2/68 |
| InsomniaPsychiatric disorders | 2/66 | 0/68 |
| Upper respiratory tract infectionInfections and infestations | 2/66 | 0/68 |
| AnemiaBlood and lymphatic system disorders | 2/66 | 0/68 |
| VomitingGastrointestinal disorders | 0/66 | 2/68 |
| Gingival hemorrhageGastrointestinal disorders | 0/66 | 2/68 |
| HyperlipemiaMetabolism and nutrition disorders | 1/66 | 1/68 |
| HypertriglyceridemiaMetabolism and nutrition disorders | 1/66 | 1/68 |
| HyperuricemiaMetabolism and nutrition disorders | 1/66 | 0/68 |
The Full Analysis Set (FAS) comprised 66 subjects in the experimental group and 68 subjects in the control group. One subject randomized to the experimental group was excluded from the analysis due to withdrawal of consent prior to receiving the experimental balloon. One subject randomized to the control group was excluded for meeting exclusion criterion 1 and did not receive the control balloon.
| Age, Continuous(years) | SINOMED CBC | NSE Coronary Dilatation Catheter | Total |
|---|---|---|---|
| Mean | 62.44 ± 8.27 | 63.72 ± 8.16 | 63.09 ± 8.21 |
| Sex: Female, Male(Participants) | SINOMED CBC | NSE Coronary Dilatation Catheter | Total |
|---|---|---|---|
| Female | 19 | 22 | 41 |
| Male | 47 | 46 | 93 |
| Race/Ethnicity, Customized(Participants) | SINOMED CBC | NSE Coronary Dilatation Catheter | Total |
|---|---|---|---|
| China | 66 | 68 | 134 |
| Number of target lesions(Participants) | SINOMED CBC | NSE Coronary Dilatation Catheter | Total |
|---|---|---|---|
| 1 Lesion | 63 | 65 | 128 |
| 2 Leisons | 3 | 3 | 6 |
PDFs hosted by the registry, ClinicalTrials.gov.
Ran from Sep 2022 to primary completion in Nov 2022, 2 months.
Results were first posted in Mar 2026, 3 years 4 months after primary completion.
Of 24 industry-sponsored interventional studies with no phase under Coronary Stenosis, half reached primary completion within 22 months of starting (the median), counting those still running; a quarter within 14 and three quarters within 41. This study's 2 months is below that.
Counting every sponsor, half of 71 studies reached it within 26 months; a quarter within 14 and three quarters within 60.
How these figures are worked out, and which studies are left out of them.
This study is completed, as verified in Mar 2026. You cannot join it, but the record below documents what was studied.
Get an email when the registry record changes — status, dates, results — or when someone posts here.
Sign in to followQuestions and observations about this study, from anyone following it. Not medical advice, and not a channel to the study team — their contact details are on the registry record.
Sign in to join the discussion. Reading takes no account; posting does. You choose a display name, and a pseudonym is the default.
Nothing here yet. If you are running this trial, taking part in it, or weighing whether to, this is the place to say so.
Sino Medical Sciences Technology Inc.