Occlusal Relationship Assesment of Monolithic Zirconia FDPs

An interventional study of Monolithic FDPs: before adjustment and Monolithic FDPs: after adjustment in Tooth-loss, sponsored by Duygu Karasan. Completed at 1 site in Turkey. Open to participants aged 20 Years to 75 Years, including healthy volunteers. Per ClinicalTrials.gov, last updated 2021-04-22.

Sponsored by Duygu Karasan · Not applicable, Interventional, and Treatment

From the registry’s dates

  • Registered 2 years 10 months after the study started (first participant enrolled May 2018, registered Apr 2021).
Phase
Not applicable
Study type
Interventional
Enrollment
14
Allocation
Non-randomized
Ages
20 Years to 75 Years
Sex
All
01

Study summary

To analyze in vivo occlusal accuracy and occlusal adjustment requirement, a cross-over clinical trial was designed. Two 3-unit tooth-supported posterior FDPs were planned to be made for each patient's single missing tooth gap, one with complete analog workflow (control group) and the other complete digital workflow (test group). The analog workflow aims for a porcelain fused to metal (PFM) FDP whereas the digital workflow aims for 3-unit monolithic Zr FDP. PFor half of the restorations, digital impression was planned to be taken first and to be followed by analog impression. As for the occlusal adjustment, in half of the study sites monolithic Zr FDPs were planned to be tried-in first, followed by metal-ceramic FDP and vice versa.

One investigator (DK) was assigned to prepare the restoration sites and deliver the FDPs. All monolithic Zr and all metal-ceramic FDPs were designed and fabricated by the same experienced dental technician. One investigator (HL), that was not involved in the treatment intervention was assigned to make the 3D analysis of the volumetric occlusal adjustment amount.

Read the detailed description

All teeth preparations will be carried out ensuring the minimum material thickness for monolithic FDPs (0.8-1 mm margin thickness, 1 mm occlusal thickness) by one experienced investigator (DK). To prevent any possible carry-over effect, the impression acquisition order will be randomized.

The control group FDPs (metal-ceramic) will be fabricated with a complete analog workflow. Accordingly, a polyether dual-phase impression (Impregum Penta Soft Quick and Soft Quick, 3M) will be taken from the restoration arch and a Polyvinylsiloxane (PVS) impression material will be used for the impression of the antagonist arch. Face bow transfer (Whip Mix Face bow0 will be done. Following the stone master model (Type IV dental rock, Fuji) obtention, the maxillary models will be mounted to a semi-adjustable articulator based on the face bow record and mandibular models will be then mounted with the aid of laterotrusive and MI records. The MI and laterotrusive records will be taken with a PVS bite registration material. The Cr-Ni frameworks will be fabricated with lost-wax technique (Brand?), manually layered with feldspathic veneering porcelain (Vita), and glazed by one experienced dental technician.

The test group FDPs (high translucent monolithic Zr) (Aidite Multilayer 3D) will be fabricated by a complete/model-free digital workflow. The digital quadrant impressions of the preparation, antagonist as well as bite registration will be obtained by the use of an IOS (Trios 3, 3Shape). The files will be sent to a CAD software (Dental System, 3Shape) directly via the communication tool (3 Shape Communicate, 3Shape). Following CAD, the high translucent monolithic Zr 3-unit FDPs will be computer-aided manufactured (CORITEC 350i Loader, imes-icore GmbH). FDPs will be high-gloss polished, glazed, and sent to the dental clinic for the try-in session. Monolithic Zr design and manufacturing process will be completed by one dental technician that is highly experienced in CAD/CAM.

Clinical occlusal adjustment:

A standardized occlusal adjustment strategy will be adopted and executed by one investigator for both control and test group FDPs. In half of the restoration sites, monolithic Zr restorations will be the ones to have been tried first whereas in the other half metal-ceramic FDPs were the first. Initially, distal and mesial approximal contact areas, then the internal fit will be checked and adjusted to eliminate any interferences in order to ensure the optimal fitting of the restorations. For the occlusal adjustment amount calculation, the FDPs will be fixed on the prepared teeth provisionally and scanned by an IOS (Trios 3, 3Shape) to record the pre-adjustment FDP volume. The occlusal contacts and adjustment needs were assessed while still the restorations are fixed. The occlusal adjustment strategy will be as follows: Under normal occlusal forces, 40-micron articulation paper (Arti-Check micro-thin, Bausch, Cologne, Germany) will be used and followed by 12-micron articulation foil (Shimstock-foil, Bausch, Cologne, Germany) under strong occlusal force. The FDPs' occlusal contact design will be ensured to hold the articulation foil under strong occlusal force. Thereafter, once ensuring the FDPs to remain fixed, intraoral digital quadrant impressions (Trios 3, 3 Shape) will be taken by the same investigator in order to record the post-adjustment volume of the FDPs. After chairside finishing and polishing of the adjustment areas, Monolithiz Zr FDPs will be adhesively luted by a composite cement as the definitive restoration.

2.4. Quantitative analysis Both .stl files (pre-and-post adjustment) will be exported in order to process in an inspection software (Gom Inspect 2019, GOM GmbH, Braunschweig, Germany). The pre-and post-adjustment .stl files will be superimposed with the surface of restorations excluding occlusal adjusted area. After that, they will be sectioned from the same planes, mesial, distal, and 3mm apical to occlusal plane. The total volume of the sections that will be analyzed will be measured and the quantitative volume difference of the sectioned parts then was Calculated three-dimensionally (3Matic, Materialise NV, Leuven, Belgium). The total volumetric difference in mm3 between pre-and post-adjustment .stl files will be calculated for each 3-unit FDP

02

Conditions studied

  • Tooth-loss

Browse trials for

Keywords

  • Occlusal Relationship
  • Complete Digital Work-flow
  • Fixed Partial Denture
  • Fixed Dental Prosthesis
03

In context

Tooth Loss

224 studies on the registry are indexed under Tooth Loss; 50 are open to participants now.

This study's enrollment of 14 is below the median of 30 across 166 interventional studies indexed under Tooth Loss.

Browse Tooth Loss studies →

Lead sponsor

This is the only study on the registry with Duygu Karasan as lead sponsor.

Counted across the registry records on this site, refreshed daily.

04

Who can participate

Ages eligible
20 Years to 75 Years
Sexes eligible
All
Accepts healthy volunteers
Yes

Inclusion criteria

  1. The individuals with the mandibular or maxillary single missing occlusal unit (2nd premolar, 1st molar) adjacent to a premolar and/or molar tooth
  2. Participants over 20 years old with no contradiction of dental treatment.
  3. Good oral hygiene habits, healthy periodontal status, no sign of bruxism (e.g. attrition score >2 according to Wigdorowicz-Makowerowa, and/or muscle pain), and no self-reported grinding and/or clenching.

Inclusion criteria for the abutment teeth included:

  1. No visible periapical lesion
  2. Presence of minimum 1:1 crown/root ratio
  3. Class I mobility (Nyman \& Lindhe 2003)
  4. No probing depth more than 4mm
  5. Presence of natural opposing teeth with no restorative treatment.
  6. Presence of a stable maximum intercuspation (MI) relationship

Exclusion criteria

Exclusion Criteria:

  • Patients and teeth that are not fulfilling the inclusion criteria
05

Study design

Phase
Not applicable
Primary purpose
Treatment
Allocation
Non-randomized
Intervention model
Parallel assignment
Masking
Double (Participant, Outcomes assessor)
Enrollment
14 participants (actual)

Study arms

  • Experimental
    Complete Digital Fixed Dental Prosthesis

    Following the Digital Impression using 3 Shape Trios Intraoral scanner, digital design, and manufacturing of the Monolithic Zirconia FDPs. Monolithic FDPs: before adjustment Using Intraoral Scanner, occlusal relationship assessment of the Monolithic FDPs before the occlusal adjustment. Monolithic FDPs: after adjustment Using Intraoral Scanner, occlusal relationship assessment of the Monolithic FDPs after the occlusal adjustment.

    Other: Monolithic FDPs: before adjustment · Other: Monolithic FDPs: after adjustment · Other: Metal fused porcelain FDPs: before adjustment · Other: Metal fused porcelain FDPs: after adjustment

  • Active comparator
    Analog Fixed Dental Prosthesis

    Following the Conventional Impression, transfer to the articulator with Face bow. Manufacturing of the FDPs with lost wax technique and veneering. Metal fused porcelain FDPs: before adjustment Using Intraoral Scanner, occlusal relationship assessment of the metal fused to porcelain FDPs before the occlusal adjustment. Metal fused porcelain FDPs: after adjustment Using Intraoral Scanner, occlusal relationship assessment of the metal fused to porcelain FDPs after the occlusal adjustment.

    Other: Monolithic FDPs: before adjustment · Other: Monolithic FDPs: after adjustment · Other: Metal fused porcelain FDPs: before adjustment · Other: Metal fused porcelain FDPs: after adjustment

Interventions

  • OtherMonolithic FDPs: before adjustment

    Before the occlusal adjustment, Occlusal relationship recording of the 3-unit monolithic FDPs which was fabricated following the complete digital work-flow.

  • OtherMonolithic FDPs: after adjustment

    After the occlusal adjustment, Occlusal relationship recording of the 3-unit monolithic FDPs which was fabricated following the complete digital work-flow.

  • OtherMetal fused porcelain FDPs: before adjustment

    Before the occlusal adjustment, Occlusal relationship recording of the 3-unit metal fused porcelain FDPs which was fabricated following the complete conventional manufacturing procedure.

  • OtherMetal fused porcelain FDPs: after adjustment

    After the occlusal adjustment, digital occlusal relationship recording was done of the 3-unit metal fused porcelain FDPs which was fabricated following the complete conventional manufacturing procedure.

06

What researchers measure

Primary outcomes

  1. The evaluation of effectiveness of workflows by assesing the occlusal registration accuracy of 3-unit FDPs that were fabricated with two different work-flows

    The occlusal registration accuracy and effectiveness of both analog and digital workflows by means of comparing quantitatively the occlusal adjustment requirement of 3-unit tooth supported metal-ceramic and Zr FDPs produced by analog work-flow use of semi-adjustable articulators with face-bow transfer and complete digital workflow, respectively

    Time frame: At the baseline, the same day of delivery

Secondary outcomes

  1. Operator and Patient reported outcomes

    The patient and operator reported outcomes will be evaulated by means of visual analog scales (VAS). The patients and operator will be asked to rate from 0 to 10 their experience of impression and overall treatment procedure. (0: inconvenient, 10 very convenient)

    Time frame: Impression visit and baseline visit (restoration delivery)

07

Study locations

1 site
  • Hacettepe University Faculty of Dentistry
    Ankara, 06230, Turkey
08

Updates

Tracking since Sep 25, 2026
No changes since tracking began. The registry record was last updated on Apr 22, 2021, before this site started recording changes on Sep 25, 2026. Its history is on ClinicalTrials.gov ↗
09

Registry details

Key details

Study ID
NCT04855084
Lead sponsor
Duygu Karasan
Collaborators
Hacettepe University
Responsible party
Duygu Karasan (Research Asistant, DDS, PhD, Hacettepe University) — Sponsor-investigator
First posted
Apr 22, 2021
Start date
May 24, 2018
Primary completion
Aug 7, 2018
Completion
Aug 27, 2018
Last update
Apr 22, 2021

Study contacts

Duygu Karasan, PhD
principal investigator · Hacettepe University Faculty of Dentistry

Oversight

FDA-regulated drug
No
FDA-regulated device
No
View the source record on ClinicalTrials.gov ↗

Not currently enrolling

This study is completed, as verified in Apr 2021. You cannot join it, but the record below documents what was studied.

Follow this study

Get an email when the registry record changes — status, dates, results — or when someone posts here.

Sign in to follow

Discussion

Questions and observations about this study, from anyone following it. Not medical advice, and not a channel to the study team — their contact details are on the registry record.

Sign in to join the discussion. Reading takes no account; posting does. You choose a display name, and a pseudonym is the default.

Nothing here yet. If you are running this trial, taking part in it, or weighing whether to, this is the place to say so.

Start the discussion