CClinicalTrials.gg
RecruitingNCT04633356Updated Mar 20, 2026

EUS Guided Portal-systemic Pressure Gradient Measurement

A Phase 1/2 interventional study of EUS-portal pressure gradient measurement (PPGM) in Portal Hypertension and Cirrhosis, sponsored by Chinese University of Hong Kong. Recruiting at 1 site in China. Open to participants aged 18 Years to 75 Years. Per ClinicalTrials.gov, last updated 2026-03-20.

Sponsored by Chinese University of Hong Kong · Phase 1/2, Interventional, and Diagnostic

From the registry’s dates

  • Started Nov 2020; still recruiting 5 years 10 months later.
Phase
Phase 1/2
Study type
Interventional
Enrollment
30
Allocation
Not applicable
Ages
18 Years to 75 Years
Sex
All
01

Study summary

Portal hypertension is characterised by an increased portal pressure gradient (PPG), that is the difference in pressure between the portal vein and the inferior vena cava (IVC). Portal hypertension is a consequence of cirrhosis resulting from chronic hepatitis. Patients with portal hypertension are at risk of developing complications including oesophageal or gastric varices, variceal bleeding, ascites, spontaneous bacterial peritonitis, hepatic encephalopathy and mortality.

Albeit its clinical significance, direct measurement of portal venous pressure to document portal hypertension has traditionally been difficult. The portal vein pressure can be measured by transhepatic or transvenous methods but the procedure carries a risk of intra-peritoneal bleeding. Furthermore, the IVC pressure measurement requires further transjugular catheterisation. Hence, the technique is rarely used. Currently, the gold standard in measurement of portal hypertension is via measurement hepatic venous pressure gradient (HVPG). The HVPG has been shown to correlate with risk of clinical decompensation, development of varices, hepatocellular carcinoma, variceal bleeding, spontaneous bacterial peritonitis and mortality. Nevertheless, the technique has a low acceptance rate amongst patients and it may not be available even in tertiary medical centres.

Recently, the use of EUS-guided approach for measurement of portal pressure gradient (PPGM) has been shown to be feasible. The technical success rate was 100% and no adverse events were reported. Measurements obtained with the EUS approach was shown to correlate excellently with clinical parameters of portal hypertension including presence of varices, portal hypertensive gastropathy and thrombocytopenia. Furthermore, the procedure could be performed at the same time of screening oesophagogastroduodenoscopy (OGD), that is frequently required for variceal screening in this group of patients. Hence, the aim of the current study is to investigate the feasibility of EUS-PPGM and correlate the risk of developing complications with the PPGM in patients that are suffering from chronic hepatitis.

Read the detailed description

Currently, the gold standard in measurement of portal hypertension is via measurement hepatic venous pressure gradient (HVPG). The HVPG has been shown to correlate with risk of clinical decompensation, development of varices, hepatocellular carcinoma, variceal bleeding, spontaneous bacterial peritonitis and mortality. The technique involves ultrasound guided puncture of the internal jugular vein, followed by passage of a balloon catheter from through the right atrium, IVC and right hepatic vein. The free hepatic vein venous pressure is then measured followed by the wedge balloon venous pressure. The HVPG is then calculated by subtracting the free hepatic venous pressure from the wedge balloon venous pressure. When HVPG is >10mmHg, the risk of developing varices is increased. If >12mmHg, then risk of variceal bleeding is increased. Mortality risk is increased when HVPG is >16-20mmHg. Nevertheless, the technique is technically difficult and it may not be available even in tertiary medical centres [8]. Furthermore, it requires the use of ionic contrast and also has a low acceptance rate amongst patients.

The aim of the current study is to investigate the feasibility of EUS-PPGM using the novel device and correlate the risk of developing complications with the PPGM in patients that are suffering from chronic hepatitis.

Recently, the use of EUS-guided approach for measurement of portal pressure gradient (PPGM) has been shown to be feasible. PPGM by the EUS approach was found to have excellent accuracy and strong correlation with pressure values obtained by the criterion standard transjugular wedged and free hepatic venous pressure measurements by interventional radiology in an animal model. Furthermore, in a pilot study involving 29 patients. The technical success rate was 100% and no adverse events were reported. Measurements obtained with the EUS approach was shown to correlate excellently with clinical parameters of portal hypertension including presence of varices, portal hypertensive gastropathy and thrombocytopenia. Furthermore, the procedure could be performed at the same time of screening oesophagogastroduodenoscopy (OGD), that is frequently required for variceal screening in this group of patients. However, whether the technique could reproduce results similar to HVPG in humans is uncertain.

02

Conditions studied

  • Portal Hypertension
  • Cirrhosis

Keywords

  • portal hypertension
  • portal pressure gradient
  • EUS interventions
  • Cirrhosis
03

In context

Hypertension, Portal

332 studies on the registry are indexed under Hypertension, Portal; 106 are open to participants now.

This study's planned enrollment of 30 is below the median of 60 across 206 interventional studies indexed under Hypertension, Portal.

Browse Hypertension, Portal studies →

Lead sponsor

Chinese University of Hong Kong is the lead sponsor of 1,419 studies on the registry; 487 are open to participants now.

Counted across the registry records on this site, refreshed daily.

04

Who can participate

Ages eligible
18 Years to 75 Years
Sexes eligible
All
Accepts healthy volunteers
No

Inclusion criteria

  • Suffering from chronic hepatitis induced cirrhosis
  • Informed consent available

Exclusion criteria

Exclusion Criteria:

  • Medical
  • Child-Pugh Class C
  • Uncorrected platelet count \<50,000
  • INR > 1.5 (natural)
  • Anatomical
  • Previous transjugular intrahepatic or surgical portosystemic shunt
  • Portal vein thrombosis
  • Anatomic alterations of the hepatic vasculature that prevent access to the portal vein or intrahepatic portion of the hepatic veins (identified at screening and/or during the endoscopic procedure).
  • Previous history of spontaneous bacterial peritonitis within the previous three months
  • Portopulmonary hypertension
  • Cardiac decompensation
  • Endoscopically Confirmed Exclusion Criteria
  • Evidence of active GI bleeding (identified at screening and/or during the endoscopic procedure)
  • If the volume of ascites in the path of the needle prevents apposition of the gastrointestinal tract and liver.
  • Presence of gastric or duodenal ulcers, dieulafoy's lesion or cancers.
05

Study design

Phase
Phase 1 / Phase 2
Primary purpose
Diagnostic
Allocation
Not applicable
Intervention model
Single group
Masking
None (open label)
Enrollment
30 participants (estimated)

Study arms

  • Experimental
    EUS-portal pressure gradient measurement (PPGM)

    All patients would receive measurement of PPGM using the study device

    Device: EUS-portal pressure gradient measurement (PPGM)

Interventions

  • DeviceEUS-portal pressure gradient measurement (PPGM)

    EUS-guided PPGM is performed under conscious sedation. An OGD would be performed to evaluate for findings consistent with portal hypertension such as varices and portal hypertensive gastropathy. The linear array echoendoscope is passed from the mouth into the stomach and duodenum, as with a standard exam. Under endoscopic ultrasound guidance, a 25 gauge EUS needle (Echotip, Cook Medical, USA) primed with heparin 100 USP/ml is then placed across the stomach or duodenal wall and through the liver parenchyma into the portal vein. A pressure measurement is then obtained from the compact pressure transducer attached to the handle of the needle. Three separate measurements are made with re-priming of heparin (less than 0.5 ml). The process is repeated for the hepatic vein. The EUS - PPG is calculated by subtracting the average of the three hepatic vein pressure measurements from the average of the 3 direct portal vein pressure measurements.

06

What researchers measure

Primary outcomes

  1. Technical success

    Ability to place a needle in the portal and hepatic vein for calculation of portal pressure gradient

    Time frame: 30 days

Secondary outcomes

  1. Adverse events

    Any untoward event directly arising from the measurement of PPGM

    Time frame: 30 day

07

Study locations

1 of 1 sites recruiting
  • Chinese University of Hong Kong
    Hong Kong, Hong Kong, China
    Recruiting
08

References and documents

Publications

  • Huang JY, Samarasena JB, Tsujino T, Lee J, Hu KQ, McLaren CE, Chen WP, Chang KJ. EUS-guided portal pressure gradient measurement with a simple novel device: a human pilot study. Gastrointest Endosc. 2017 May;85(5):996-1001. doi: 10.1016/j.gie.2016.09.026. Epub 2016 Sep 29. PubMed 27693644 ↗
  • Huang JY, Samarasena JB, Tsujino T, Chang KJ. EUS-guided portal pressure gradient measurement with a novel 25-gauge needle device versus standard transjugular approach: a comparison animal study. Gastrointest Endosc. 2016 Aug;84(2):358-62. doi: 10.1016/j.gie.2016.02.032. Epub 2016 Mar 3. PubMed 26945557 ↗

Individual participant data

Plan to share: No

09

Updates

Tracking since Sep 25, 2026
No changes since tracking began. The registry record was last updated on Mar 20, 2026, before this site started recording changes on Sep 25, 2026. Its history is on ClinicalTrials.gov ↗
10

Registry details

Key details

Study ID
NCT04633356
Lead sponsor
Chinese University of Hong Kong
Responsible party
Anthony Teoh (Associate Professor, Chinese University of Hong Kong) — Principal investigator
First posted
Nov 18, 2020
Start date
Nov 12, 2020
Primary completion
Nov 11, 2026 (estimated)
Completion
Nov 11, 2026 (estimated)
Last update
Mar 20, 2026

Study contacts

Anthony Y Teoh, FRCSEd
Contact
anthonyteoh@surgery.cuhk.edu.hk
35052956

Oversight

Data monitoring committee
No
FDA-regulated drug
No
FDA-regulated device
Yes
View the source record on ClinicalTrials.gov ↗

Interested in this study?

Eligibility is decided by the study team. Share this record with your doctor or contact the team directly.

Contact study team

Follow this study

Get an email when the registry record changes — status, dates, results — or when someone posts here.

Sign in to follow

Discussion

Questions and observations about this study, from anyone following it. Not medical advice, and not a channel to the study team — their contact details are on the registry record.

Sign in to join the discussion. Reading takes no account; posting does. You choose a display name, and a pseudonym is the default.

Nothing here yet. If you are running this trial, taking part in it, or weighing whether to, this is the place to say so.

Start the discussion