An interventional study of Treatment with IPL device in Hair Removal, sponsored by Philips Healthcare. Completed at 3 sites in United States. Open to female participants aged 18 Years to 65 Years, including healthy volunteers. Per ClinicalTrials.gov, last updated 2022-10-19.
Sponsored by Philips Healthcare · Not applicable, Interventional, and Treatment
Prospective, multi-center, single-arm, single blinded (Philips hair counter) study in healthy women of skin types I up to and including V.
Safety and efficacy of hair removal with the Emerald IPL-device will be investigated for treatment in face of subjects with ST I - IV and for treatment in face, axilla, bikini area, and legs of subjects with ST V.
In-clinic, the study subjects will undergo twelve IPL-treatments bilaterally at the qualified areas (face and / or axilla, bikini line, and legs) with the Emerald IPL device applied by a device operator.
Hair re-growth in each area will be evaluated separately and across all skin types.
After the 4 bi-weekly treatments, one follow-up visit will be organized two weeks after the 4th treatment. After the completion of the full treatment cycle (12 treatments), subjects will be followed for 1 and 3 months (short-term follow-up) and for 6, 9 and 12 months (long-term follow up).
Hair grows in cyclic phases: anagen, catagen and telogen. These phases impact on how the process of light-based hair removal works. The hair grows during the anagen phase, which has the longest duration in the hair growth cycle. Hair growth ends with the transition from anagen into the catagen phase, a short transition phase to prepare for the resting phase, the telogen, which ends with shedding of the hair and the start of the hair growth cycle. During telogen phase, the hair follicle remains inactive. Each hair follicle is independent and goes through the growth cycle at different times. As presented in table 5 [11], the duration of the growth cycle of the upper lip, axilla and bikini line are different from that of the legs. In general, the telogen and anagen phase's durations of the cycle are longest for the legs (i.e., 24 and 16 weeks, respectively) and the shortest for upper lip (i.e. 6 weeks for both phases). Therefore, hair response to the IPL treatment will be evaluated by body area.
The efficacy of permanent hair reduction will be measured following the definition of permanent hair reduction according to the FDA as follows: "Permanent hair reduction is defined as the long-term, stable reduction in the number of hairs re-growing after a treatment regime, which may include several sessions. The number of hairs re-growing must be stable over time greater than the duration of the complete growth cycle of hair follicles, which varies from four to twelve months according to body location. Permanent hair reduction does not necessarily imply the elimination of all hairs in the treatment area."
In an attempt to promote permanent hair reduction, the aim is to expose all hairs at least once to an IPL flash and therefore treatment will cover the full duration of a hair growth cycle). The longest relevant full hair growth cycle is on the legs (40 weeks, excluding approximately 2 weeks for the catagen phase). Therefore, a treatment duration of 10 months (approximately 38weeks) has been selected: a full IPL treatment cycle consists of 4 initial treatments, once every 2 weeks, followed by 8 maintenance (monthly) treatments, once every 4 weeks. The hair growth cycle on face (upper lip) is the shortest (12 weeks, 6 weeks in anagen, 6 weeks in telogen phases). The initial treatments in 2 weeks interval are expected to be most beneficial for face treatment.
For this study, there are two cohorts for enrollment:
The visits are as follows:
Screening Visit: The volunteers are screened to identify subjects who meet all of the inclusion and none of the exclusion criteria. Device settings are selected based on skin tone and comfort evaluation..
Visits 1-4 (TX1-TX4): Four treatments and the collection of safety and efficacy data are scheduled to occur every 2 weeks/ 14 days; Visits 5 (Initial Treatment 2wk Follow-up): Safety and efficacy data are collected 2 weeks/ 14 days after 4th treatment to demonstrate hair removal performance 8 weeks after baseline.
Have natural body hair color that is dark blonde, brown or black in the designated treatment areas
3.1. Subjects of ST I-IV - Face group:
3.1.1 Have Fitzpatrick Skin Type I, II, III, or IV
3.1.2 Measure melanin value ≤ 375 in the qualifying treatment areas bilateral on upper lip (face)
3.1.3. Have a minimum of 10 hairs in the 1x2cm2 qualifying treatment areas bilateral on upper lip (face), by visual inspection
3.2. Subjects of ST V - All body area group:
3.2.1. Have Fitzpatrick Skin Type V
3.2.2. Measure melanin value ≤ 553 in the qualifying treatment areas bilateral on upper lip (face), axilla, bikini line, and leg
3.2.3. Have a minimum of 10 hairs in the 1x2cm2 qualifying treatment areas bilateral on upper lip (face), by visual inspection
3.2.4.Have a minimum of 24 hairs in each of the 2x4cm2 qualifying treatment areas bilateral on axilla, bikini line, and leg, by visual inspection
Exclusion Criteria:
Have natural body hair color that is white, light blond, or red in the designated treatment areas
1.1. Subjects of ST I to IV - Face group:
1.1.1. Have Fitzpatrick Skin Type V or VI
1.1.2. Measure melanin value higher than 375 in the qualifying treatment areas bilateral on upper lip
1.1.3. Have fewer than 2 qualifying treatment areas on bilateral on upper lip (face)
1.2. Subjects of ST V - All body area group:
1.2.1. Have Fitzpatrick Skin Type I, II, III, IV, or VI
1.2.2. Measure melanin value higher than 553 in any of the qualifying treatment areas bilateral on the body
1.2.3. Have fewer than 8 qualifying treatment areas bilateral: 2 in face, 2 in axilla, 2 on bikini line, and 2 on legs
The Emerald IPL device is applied by the Investigator or designee to the right and left side of the body. Treatment areas are 2x4 cm2 for the leg and bikini line areas. The entire axilla and face (upper lip) area will be treated due to the small area involved.
Device: Treatment with IPL device
Treatment with IPL device
Proportion of subjects with at least 30% hair reduction relative to baseline at 8 and 10 weeks after baseline and at 1 and 3 months after last treatment
Efficacy of the device will be measured by evaluating the proportion of subjects with \>= 30% hair reduction on the face, axilae, bikini area and legs following the intensive treatment phase at 8 and 10 weeks as well as during short term follow up of 1 month and 3 months after the last treatment.
Time frame: approximately 13 months
Safety will be measured by proportion of treatment-emerged, anticipated adverse events, non-anticipated adverse events, serious adverse events and other related reasons for discontinuation.
The primary safety endpoints include the treatment-emerged, anticipated adverse events, non-anticipated adverse events, serious adverse events and reasons for discontinuation during the treatment of the face, axilae, bikini area and legs with the device as well as during the follow-up period.
Time frame: Approximately 22 months
Assessment of the subjective satisfaction with the treatment results of the Emerald IPL device for removal of unwanted hair on face, axillae, bikini area, and legs: 5-point Likert satisfaction scale
Percent of top-two category answers of 5-point Likert satisfaction scale in assessment of subjective satisfaction with the treatment results in all body areas.
Time frame: Approximately 22 months
Assessment of the acceptance of the Emerald IPL devices for removal of unwanted hair in each body area: Percent of top-two category answers in assessment of acceptance
Percent of top-two category answers in assessment of acceptance of hair reduction, skin smoothness, and comfort after treatment with Philips investigational IPL devices in all body areas.
Time frame: Approximately 22 months
Proportion of subjects with at least 30% hair reduction relative to baseline at 6, 9 and 12 months post-final treatment per body area.
Efficacy of the device will be measured by evaluating the proportion of subjects with \>= 30% hair reduction on the face, axilae, bikini area and legs during the long term follow up of 1 month and 3 months after the last treatment.
Time frame: Approximately 22 months
Exploratory Endpoint
Percent of subjects with the same device setting as Setting Indication by STS device and device setting as result of Test Flash or as result of skin type self-assessment.
Time frame: Approximately 18 months
Plan to share: No
This study is completed, as verified in Oct 2022. You cannot join it, but the record below documents what was studied.
Get an email when the registry record changes — status, dates, results — or when someone posts here.
Sign in to followQuestions and observations about this study, from anyone following it. Not medical advice, and not a channel to the study team — their contact details are on the registry record.
Sign in to join the discussion. Reading takes no account; posting does. You choose a display name, and a pseudonym is the default.
Nothing here yet. If you are running this trial, taking part in it, or weighing whether to, this is the place to say so.
Philips Healthcare