Low Energy Dissection Vs. Electrocautery in Lumpectomy Shaved Surgical Margins

An observational study in Breast Cancer Female, sponsored by Invuity, Inc.. Status unknown. Open to female participants aged 18 Years and older. Per ClinicalTrials.gov, last updated 2018-10-24.

Sponsored by Invuity, Inc. · Observational

The sponsor has not verified this record recently (last verified Oct 2018), so the status shown — last known as Not yet recruiting — may be out of date.
Study type
Observational
Model
Case-only
Time perspective
Prospective
Enrollment
20
Ages
18 Years and older
Sex
Female
01

Study summary

The purpose of this study is to compare the qualitative severity and depth of dissection devices' associated thermal artifact in breast lumpectomy shaved margins between the use of electrocautery and low thermal energy dissection, PhotonBlade.

The investigators hypothesize that the use of PhotonBlade would result in a significantly lower qualitative severity and a shorter depth of thermal artifact in breast lumpectomies shaved margins, when compared to electrocautery devices.

Read the detailed description

When performing lumpectomy, surgeons have used electrocautery devices as dissecting tools. However, those devices use high thermal energy that might impact the margin cellular architecture and as such the quality of margin assessment by the pathologist. Moreover, recently, modern low thermal energy dissection devices have been introduced to the market. However, the impact of those devices on reducing the thermal injury/artifact on surgical margin has not been well investigated. 4,5 While Ruidaz et al. 2011 data suggest that using the traditional electrosurgical device in place of the low thermal-injury device results in 48% of the close margin samples being negatively converted to false-positive, and in 11% converting from close to false-negative, there is still a need for more studies to further characterize the utility of those devices. 6 PhotonBlade (Invuity, San Francisco, CA, USA) has been approved by United States Food and Drug Administration (FDA). PhotonBlade is a dynamic precision illuminator with enhanced energy delivery dissection device. The dynamic precision illumination is a thermally cool illumination technology that allows a uniformal illumination without glare or shadow. 7 The enhanced energy delivery technology allows low thermal spread, surgeon controlled edge temperature, and wet field use.7 As such, PhontonBlade allows better blade control for achieving adequate visualization, hemostasis, with a minimum collateral damage to the surgical margin tissue. The use of PhotonBlade demonstrated the least penetrating thermal tissue damage/spread when compared to other modern dissection devices (Valleylab Pencil, Valleylab EDGE Coated Pencil, PlasmaBlade 3.0S and PlasmaBlade 4.0).8

02

Conditions studied

  • Breast Cancer Female

Browse trials for

03

In context

Breast Neoplasms

12,544 studies on the registry are indexed under Breast Neoplasms; 2,892 are open to participants now.

This study's planned enrollment of 20 is below the median of 184 across 2,642 observational studies indexed under Breast Neoplasms.

Browse Breast Neoplasms studies →

Lead sponsor

Invuity, Inc. is the lead sponsor of 2 studies on the registry; none are open to participants now.

Counted across the registry records on this site, refreshed daily.

04

Who can participate

Ages eligible
18 Years and older
Sexes eligible
Female
Accepts healthy volunteers
No
Sampling method
Probability sample

Study population

Women who have a diagnosis of breast cancer and undergo a lumpectomy

Inclusion criteria

  • have aged 18 years old or older.
  • have DCIS or Invasive breast cancer that is eligible for breast-conserving surgery.
  • have not had previous chest radiotherapy.
  • understand the study purpose, requirements, and risks.
  • able and willing to give informed consent.

Exclusion criteria

Exclusion Criteria:

  • None
05

Study design

Observational model
Case-only
Time perspective
Prospective
Enrollment
20 participants (estimated)
Patient registry
No
Biospecimen retention
Samples with dna

Groups and cohorts

  • Breast cancer patients - lumpectomy

    Women who are 18 years or older, have Ductal carcinoma in situ (DCIS) or invasive breast-conserving surgery, have not had previous chest radiotherapy. 20 patients who meet above study population criteria will be enrolled in this study.Shaved margins for each lumpectomy site will be excised with either Bovie (3 sides) or PhotonBlade (3 sides) for each patient. The effect of PhotonBlade vs Bovie on pathology assessment of lumpectomy shaved surgical margins will be compared.

    Device: PhotonBlade vs Bovie for lumpectomy shaved surgical margins

Interventions

  • DevicePhotonBlade vs Bovie for lumpectomy shaved surgical margins

    For each enrolled patient, six shaved margins will be obtained (superior, inferior, medial, lateral, anterior, and posterior). For each patient, electrocautery will be used to obtain 3 of the shaved margins, and PhotonBlade to obtain the other 3 shaved margins. Once the lumpectomy site shaved margins have been obtained, the shaved surgical margins will be evaluated by a pathologist whom is blinded in regards to the dissection device that was used for each margin. The pathologist will be evaluating each shaved margin and reporting the outcomes (qualitative severity and depth of thermal artifact)

06

What researchers measure

Primary outcomes

  1. Severity of thermal artifact

    The severity of the thermal artifact will be assessed by identifying the presence or absence of each the three qualitative severity zones, described previously,6 as below: * Zone I: extensive charring tissue * Zone II: fused cellular architecture * Zone III: distressed cellular architecture

    Time frame: Through study completion, an average of 6 months

  2. Depth of thermal artifact

    The depth of the thermal artifact will be assessed by reporting the length in micrometer (μm) from the start of Zone 1 to the end of Zone III.

    Time frame: Through study completion, an average of 6 months

07

Study locations

No study locations are listed for this record.

08

References and documents

Publications

  • ACS. Breast Cancer Facts and Figures 2011-2012. (2012).
  • Vila J, Gandini S, Gentilini O. Overall survival according to type of surgery in young (</=40 years) early breast cancer patients: A systematic meta-analysis comparing breast-conserving surgery versus mastectomy. Breast. 2015 Jun;24(3):175-81. doi: 10.1016/j.breast.2015.02.002. Epub 2015 Feb 23. PubMed 25728282 ↗
  • Pleijhuis RG, Graafland M, de Vries J, Bart J, de Jong JS, van Dam GM. Obtaining adequate surgical margins in breast-conserving therapy for patients with early-stage breast cancer: current modalities and future directions. Ann Surg Oncol. 2009 Oct;16(10):2717-30. doi: 10.1245/s10434-009-0609-z. Epub 2009 Jul 17. PubMed 19609829 ↗
  • Chiappa C, Rovera F, Corben AD, Fachinetti A, De Berardinis V, Marchionini V, Rausei S, Boni L, Dionigi G, Dionigi R. Surgical margins in breast conservation. Int J Surg. 2013;11 Suppl 1:S69-72. doi: 10.1016/S1743-9191(13)60021-7. PubMed 24380558 ↗
  • Ruidiaz ME, Cortes-Mateos MJ, Sandoval S, Martin DT, Wang-Rodriguez J, Hasteh F, Wallace A, Vose JG, Kummel AC, Blair SL. Quantitative comparison of surgical margin histology following excision with traditional electrosurgery and a low-thermal-injury dissection device. J Surg Oncol. 2011 Dec;104(7):746-54. doi: 10.1002/jso.22012. Epub 2011 Jul 8. PubMed 21744349 ↗
  • Haydon E. et al. Assessment of penetrating thermal tissue damage/spread associated with PhotonBlade™, Valleylab™ Pencil, Valleylab™ EDGE™ Coated Pencil, PlasmaBlade® 3.0S and PlasmaBlade® 4.0 for intraoperative tissue dissection using the fresh extirpated porcine muscle model

Individual participant data

Plan to share: Undecided — No plan in place at this time.

09

Updates

Tracking since Sep 25, 2026
No changes since tracking began. The registry record was last updated on Oct 24, 2018, before this site started recording changes on Sep 25, 2026. Its history is on ClinicalTrials.gov ↗
10

Registry details

Key details

Study ID
NCT03718442
Lead sponsor
Invuity, Inc.
Collaborators
Montefiore Medical Center
Responsible party
Sponsor
First posted
Oct 24, 2018
Start date
Mar 15, 2019 (estimated)
Primary completion
Dec 15, 2019 (estimated)
Completion
Jun 15, 2020 (estimated)
Last update
Oct 24, 2018

Study contacts

Dennise D Dalma-Weiszhausz, PhD
Contact
ddalma@invuity.com
6502486662
John Kang
Contact
jkang@invuity.com
415-846-9105

Oversight

Data monitoring committee
Yes
FDA-regulated drug
No
FDA-regulated device
Yes
View the source record on ClinicalTrials.gov ↗

Not currently enrolling

This study is status unknown, as verified in Oct 2018. You cannot join it, but the record below documents what was studied.

Follow this study

Get an email when the registry record changes — status, dates, results — or when someone posts here.

Sign in to follow

Discussion

Questions and observations about this study, from anyone following it. Not medical advice, and not a channel to the study team — their contact details are on the registry record.

Sign in to join the discussion. Reading takes no account; posting does. You choose a display name, and a pseudonym is the default.

Nothing here yet. If you are running this trial, taking part in it, or weighing whether to, this is the place to say so.

Start the discussion