An interventional study of Fluoroscopy Guided Spinal Biopsy and CT guided Spinal Biopsy in Spondylodiskitis and Spinal Tumor, sponsored by University of Malaya. Completed at 1 site in Malaysia. Open to participants aged 18 Years and older. Per ClinicalTrials.gov, last updated 2018-07-19.
Sponsored by University of Malaya · Not applicable, Interventional, and Diagnostic
Spinal biopsy is important to obtain culture and histopathological diagnosis in spine infection and tumors. To date, there is no prospective randomized study comparing both techniques. Therefore, the aim of this prospective randomized trial was to evaluate the accuracy, safety and diagnostic outcome of both these techniques.A prospective randomized trial was performed in 60 patients divided equally into fluoroscopic and CT guided spinal biopsy groups. Transpedicular approach was done with 8G core biopsy needle. Specimens were sent for histopathological examinations and cultures. Diagnosis were made based on biopsy results, clinical criteria and disease progression during 6 months follow up. Radiation expose to patients and doctors were measured with optically stimulated luminescence dosimeters (OSLDs).
This prospective randomized study was carried out in a single institution from November 2016 to June 2018.
Patients were recruited by three spine surgeons from the same institution after eligibility assessment. Sixty consecutive patients were randomized equally into fluoroscopic and CT guided spinal biopsy groups. Randomization procedure was performed using a computer generated random number sequence on www.random.org. Separate individuals completed the random allocation sequence, patient enrollment and outcome assessment. Outcome assessors were blinded to group assignment.
Data collection Clinical data collected were: patient demographics, comorbidities, infective parameters, tumor markers, Magnetic Resonance Imaging (MRI) findings and pre-biopsy pain score at rest using visual analogue scale (VAS). Intraoperative data included radiation exposure dosage, biopsy duration and complications encountered. Following biopsy, we recorded the biopsy result, 6-hourly pain score (VAS) at for 48 hours, additional analgesia requirement and complications.
Radiation measurement Commercial optically stimulated luminescence dosimeters, OSLDs (NanoDotTM Dosimeter, Landauer Inc, Glenwood, IL) were used to measure radiation dose. Ten OSLDs were placed on patients and doctors prior to all biopsies over selective areas representing radiosensitive organs. Placements of the OSLDs were done by a single observer. OSLDs were processed using MicroStar OSLD reader system (Landauer, Inc. Glenwood, IL). Each OSLD was processed 3 times during each reading to obtain a mean value to minimize error. The absorbed doses were measured in centigrays (cGy). Bleaching/zeroing of the OSLDs were done using optical annealing system containing fluorescent lamps (Osram lumilux, 24 W, 280 \~780 nm) in between each use of OSLDs.
Biopsy technique Transpedicular approach with an 8-gauge T-Lok™ bone marrow biopsy needle (Argon Medical Devices, Athens, TX, USA) was used in both arms. 10cc 2% lignocaine was infiltrated prior to biopsy. Biopsy needle was tapped gently with mallet through the pedicle and into the lesion under imaging guidance. Trocar was then withdrawn once it reached the affected area. The cannula was rotated several times to disengage sample from surrounding tissue. Then, aspiration of samples was done using 10-ml syringe prior to retraction of the cannula. Tissue samples were retrieved from the cannula with the use of stylet.
Samples collected were sent to laboratories for histopathological examination (HPE), culture and sensitivity (bacteriology, mycology and acid-fast bacilli), staining (Gram and Ziehl-Neelsen) and polymerase chain reaction (PCR) test for Mycobacterium tuberculosis.
Post biopsy care Antimicrobials were commenced upon completion of biopsy for patients who were diagnosed to have spine infection. Disease progression was assessed based on clinical symptoms, ESR, CRP and/or MRI repeated during 6 months follow up for patients who were not treated for spinal infection.
For suspected spinal tumor cases, negative biopsies that were reported to have inadequate sample, were repeated with the other method or other investigation modalities will be resorted accordingly. Patients with negative biopsy that was reported to have adequate sample were follow up for 6 months for disease progression.
Sample size Sample size was determined based on accuracy of biopsy as outcome variable, in which the accuracy rate was 0.89. It was estimated using G*Power software (version 3.1.9.2) based on 2 proportions formula (Fisher's exact test). With alpha level of 0.05, 95% confidence interval and power of study 0.8, a minimum number of 52 patients (26 patients for each arm) was required for this study.
Statistical analysis Data were analyzed with SPSS Inc., Chicago, IL (SPSS v 23). Continuous data were reported as mean ± standard deviation and compared using t test. Chi-squared testing was used for between-groups comparisons. Fisher-exact test was used for the comparison of diagnostic accuracy between fluoroscopic and CT guided spinal biopsy. A p-value of \<0.05 was considered significant.
24 studies on the registry are indexed under Discitis; 5 are open to participants now.
Browse Discitis studies →University of Malaya is the lead sponsor of 284 studies on the registry; 58 are open to participants now.
Counted across the registry records on this site, refreshed daily.
Go through the criteria one by one — yes, no or not sure — and take the list to your doctor or the study team. Kept in this browser only.
Exclusion Criteria:
Underlined terms in the criteria open these too. Explained by clinicaltrials.gg, not part of the registry record. The study team decides who can take part.
Malignancy means cancer. Criteria about another or earlier malignancy ask whether you have had a different cancer, usually within a set number of years.
Some are commonly allowed, such as treated skin cancers other than melanoma and early cancers removed completely — check the exceptions this study lists.
A biopsy takes a small piece of tissue to examine. “Archival tissue” is a sample already taken, for example at diagnosis, and kept by the hospital.
Whether a stored sample will do depends on when it was taken, how much there is and what the study needs. Ask whether the study accepts your stored sample or needs a new biopsy.
Cancer (malignancy)
Malignancy means cancer. Criteria about another or earlier malignancy ask whether you have had a different cancer, usually within a set number of years.
Some are commonly allowed, such as treated skin cancers other than melanoma and early cancers removed completely — check the exceptions this study lists.
Explained by clinicaltrials.gg, not part of the registry record. The study team decides who can take part.
Biopsy and archival tissue
A biopsy takes a small piece of tissue to examine. “Archival tissue” is a sample already taken, for example at diagnosis, and kept by the hospital.
Whether a stored sample will do depends on when it was taken, how much there is and what the study needs. Ask whether the study accepts your stored sample or needs a new biopsy.
Explained by clinicaltrials.gg, not part of the registry record. The study team decides who can take part.
Fluoroscopy guided spinal biopsies were done by spine surgeons in the operation theatre using C-Arm fluoroscopy device (OECFluorostar7900Compact - GE®). C-arm image intensifier was positioned until fluoroscopic beam was collinear with the corresponding vertebral body on AP view prior to insertion of biopsy needle
Diagnostic Test: Fluoroscopy Guided Spinal Biopsy
CT guided spinal biopsies were done by radiologist under guidance of 128-slice CT scanner (SOMATOM Definition AS+, Siemens Medical Solutions USA, Inc.). Preliminary axial CT scanning was done in bone window (window width, WW:2500; window level, WL:500) at the pre-selected levels decided from previous imaging to plan the needle access. Biopsy was then performed under sequential CT-fluoroscopy scan.
Diagnostic Test: CT guided Spinal Biopsy
Spinal biopsy done via Transpedicular approach with an 8-gauge T-Lok™ bone marrow biopsy needle under fluoroscopic guidance. Samples collected were sent to laboratories for histopathological examination (HPE), culture and sensitivity (bacteriology, mycology and acid-fast bacilli), staining (Gram and Ziehl-Neelsen) and polymerase chain reaction (PCR) test for Mycobacterium tuberculosis.
Spinal biopsy done via Transpedicular approach with an 8-gauge T-Lok™ bone marrow biopsy needle under CT guidance. Samples collected were sent to laboratories for histopathological examination (HPE), culture and sensitivity (bacteriology, mycology and acid-fast bacilli), staining (Gram and Ziehl-Neelsen) and polymerase chain reaction (PCR) test for Mycobacterium tuberculosis.
Diagnostic accuracy of fluoroscopic and CT guided spinal biopsy
Diagnostic accuracy were determined based on true positive, true negative, false positive and false negative biopsy findings
Time frame: 6 months
Radiation expose to patients and doctors
Total of 10 commercial optically stimulated luminescence dosimeters (OSLDs) were placed on patients and doctors at different body areas prior to biopsy to measure radiation dose
Time frame: During biopsy
Pre biopsy and post biopsy pain score assessed by visual analogue scale (VAS)
Pre biopsy pain score and post biopsy pain score (6-hourly for 48 hours) were assessed base on visual analogue scale (VAS) and recorded. Pain score will be aggregated by mean and standard deviation and compared between both groups. Additional analgesia requirement was documented.
Time frame: 48 hours post biopsy
Complications of spinal biopsy
Complications of spinal biopsy were observed such as neurovascular injury and iatrogenic fracture.
Time frame: During and 48 hours after spinal biopsy
Plan to share: Undecided
No publications or documents are linked to this record.
This study is completed, as verified in Jul 2018. You cannot join it, but the record below documents what was studied.
Get an email when the registry record changes — status, dates, results — or when someone posts here.
Sign in to followQuestions and observations about this study, from anyone following it. Not medical advice, and not a channel to the study team — their contact details are on the registry record.
Sign in to join the discussion. Reading takes no account; posting does. You choose a display name, and a pseudonym is the default.
Nothing here yet. If you are running this trial, taking part in it, or weighing whether to, this is the place to say so.