An interventional study of Rapid Prototyping method of fabrication of complete denture and Conventional method of fabrication of complete denture in Stability, sponsored by Cairo University. Status unknown. Open to participants aged 40 Years to 70 Years, including healthy volunteers. Per ClinicalTrials.gov, last updated 2017-04-19.

Sponsored by Cairo University · Not applicable, Interventional, and Other

The sponsor has not verified this record recently (last verified Apr 2017), so the status shown — last known as Not yet recruiting — may be out of date.
Phase
Not applicable
Study type
Interventional
Enrollment
14
Allocation
Randomized
Ages
40 Years to 70 Years
Sex
All
01

Study summary

In this study we are going to compare dimensional accuracy of maxillary complete denture base fabricated by using rapid prototyping method and conventional method.

We hypothesize that both techniques do not significantly differ from each other

Read the detailed description

The study will be carried out in the department of prosthodontics, Faculty of Oral and Dental Medicine, Cairo University. Fourteen patients will be selected from the out-patient clinic according to the inclusion and exclusion criteria, the participants will be divided randomly into two equal groups. The clinical procedures on denture fabrication for both groups will be carried out by TS. The laboratory steps will be carried out by one well trained dental technician (MA). The set of dentures will be fabricated according to the conventional method (Group C) as follow: First appointment: preliminary impression will be obtained by using irreversible hydrocolloid (alginate, cavex, normal set) in stainless steel stock trays. Trays will be augmented with warm utility wax strips (cavex) and shaped by tongue movements and manipulation of labial and buccal tissues. A special tray will be prepared with self-cured acrylic resin (Acrostone-Egypt) over the study cast poured from preliminary impression. Second appointment: A secondary impression will be made with putty rubber base as a border molding material and the final impression will be made with medium rubber base impression material. The final impressions will be poured with type 4 Hydrocal dental stone (Hydrocal Dental stone, Moldano, Bayer Leverkusen, and Germany) to obtain the master cast which will be used for constructing self-cured acrylic resin trial denture bases that will carry a wax occlusion rim. Third appointment: A face bow record will be made to transfer the relation of the maxilla to the temporomandibular joint. Maxilla-mandibular relationship will be recorded using maxillary and mandibular occlusion rims formed over the master cast. Fourth appointment: Setting of artificial teeth will be performed and trial dentures will be tried in inside patients' mouth. Fifth appointment: The finished and polished dentures will be delivered immediately after the necessary adjustments and instructions regarding hygiene and maintenance. The other set of dentures (Group R) will be fabricated according to the rapid prototyping Stereo lithography (SLA) method. The detailed procedures are the same as described for the conventional method (Group C) except for that master casts will be scanned to fabricate the denture bases. The obtained master casts will be used to attach three stainless steel pins before fabrication of the denture bases to assess the linear dimensional changes at the following positions; A: pin at the incisive papilla B: pin at the right second molar area C: pin at the left second molar area Digital caliper will be used to measure distance between the points (AB, BC and CA) and each measurement will be repeated five times. The mean of five readings will be taken as a single reading to decrease the percentage of error. For Conventional Methods: Self-cured acrylic resin trial denture bases will be constructed on the obtained master casts, then processing of the final denture bases by conventional clamping method cured by long curing cycle (74º C for 8 hours) using heat-cured poly-methyl methacrylate (PMMA) resin material. The position of the pins will be recorded into the denture bases so that the linear changes could be measured. For Rapid Prototyping Method: the master casts will be scanned using DENTAL WINGS eco-scan 3, using laser technology for scanning, after spraying the stainless steel pins with scanning spray to be recorded into the denture base. Virtual model will be obtained for fabrication of denture bases. Denture base will be designed and modified on the virtual model, then it will be printed using ZENITH-3D Printer using Urethane acrylate oligomer based photo-polymerized resin. After finishing and polishing of the conventional denture bases and printing of rapid prototyped denture bases, evaluation of linear dimensional changes will be carried out through recording five reading for each of the three dimensions and a mean value will be calculated using digital caliper. This value will be calculated for the master model. The same procedure will be repeated for the two experimental groups (A\&B). The dimensional changes will be determined based on the difference between the two values for each method and all records will be tabulated and analysis will be done for the differences between records.

02

Conditions studied

  • Stability

Keywords

  • Rapid Prototyping technique
  • complete denture
03

In context

Lead sponsor

Cairo University is the lead sponsor of 4,909 studies on the registry; 1,445 are open to participants now.

Of its 37 completed or terminated interventional studies of FDA-regulated products, 5 (14%) have results posted.

Counted across the registry records on this site, refreshed daily.

04

Who can participate

Ages eligible
40 Years to 70 Years
Sexes eligible
All
Accepts healthy volunteers
Yes

Go through the criteria one by one — yes, no or not sure — and take the list to your doctor or the study team. Kept in this browser only.

Inclusion criteria

  • Age ranging from 40-70 years.
  • Class I Angle's ridge relationship.
  • Literate patients are able to understand and respond to a written questionnaire in Arabic.
  • Cooperative patients with no history psychological diseases.
  • A period of at least six months should elapse from the last extraction.

Exclusion criteria

Exclusion Criteria:

  • Pathological changes of residual ridges.
  • Patients with debilitating systemic diseases.
  • Patients with xerostomia.
  • Patients with temporo-mandibular joint disorders or systemic or neuromuscular disorder that might affect chewing efficiency of masticatory muscles.
  • Patients with macroglossia or microstomia
  • Patients with flabby and flat ridges.
  • Patients with allergy to acrylic resin
05

Study design

Phase
Not applicable
Primary purpose
Other
Allocation
Randomized
Intervention model
Parallel assignment
Masking
Quadruple (Participant, Care provider, Investigator, Outcomes assessor)
Enrollment
14 participants (estimated)

Study arms

  • Experimental
    Group R

    Rapid Prototyping method of fabrication of complete denture: the master casts will be scanned using DENTAL WINGS eco-scan 3, using laser technology for scanning, after spraying the stainless steel pins with scanning spray to be recorded into the denture base. Virtual model will be obtained for fabrication of denture bases. Denture base will be designed and modified on the virtual model, then it will be printed using ZENITH-3D Printer using Urethane acrylate oligomer based photo-polymerized resin.

    Device: Rapid Prototyping method of fabrication of complete denture

  • Active comparator
    Group C

    Conventional method of fabrication of complete denture: Self-cured acrylic resin trial denture bases will be constructed on the obtained master casts, then processing of the final denture bases by conventional clamping method cured by long curing cycle (74º C for 8 hours) using heat-cured poly-methyl methacrylate (PMMA) resin material. The position of the pins will be recorded into the denture bases so that the linear changes could be measured.

    Device: Conventional method of fabrication of complete denture

Interventions

  • DeviceRapid Prototyping method of fabrication of complete denture

    For Rapid Prototyping Method of fabrication of complete denture : the master casts will be scanned using DENTAL WINGS eco-scan 3, using laser technology for scanning, after spraying the stainless steel pins with scanning spray to be recorded into the denture base. Virtual model will be obtained for fabrication of denture bases. Denture base will be designed and modified on the virtual model, then it will be printed using ZENITH-3D Printer using Urethane acrylate oligomer based photo-polymerized resin.

  • DeviceConventional method of fabrication of complete denture

    For Conventional Method of fabrication of complete denture: Self-cured acrylic resin trial denture bases will be constructed on the obtained master casts, then processing of the final denture bases by conventional clamping method cured by long curing cycle (74º C for 8 hours) using heat-cured poly-methyl methacrylate (PMMA) resin material. The position of the pins will be recorded into the denture bases so that the linear changes could be measured.

06

What researchers measure

Primary outcomes

  1. dimensional accuracy of complete denture

    dimensional accuracy of complete denture will be measured using digital caliper

    Time frame: 1 month

07

Study locations

No study locations are listed for this record.

08

References and documents

Individual participant data

Plan to share: Undecided

No publications or documents are linked to this record.

09

Updates

Tracking since Sep 25, 2026
No changes since tracking began. The registry record was last updated on Apr 19, 2017, before this site started recording changes on Sep 25, 2026. Its history is on ClinicalTrials.gov ↗
10

Registry details

Key details

Study ID
NCT03119753
Lead sponsor
Cairo University
Responsible party
Tarek Salah Hashim Ali (principle investigator, Cairo University) — Principal investigator
First posted
Apr 19, 2017
Start date
Jun 10, 2017 (estimated)
Primary completion
Jul 10, 2017 (estimated)
Completion
Sep 10, 2017 (estimated)
Last update
Apr 19, 2017

Oversight

Data monitoring committee
Yes
FDA-regulated drug
No
FDA-regulated device
No
View the source record on ClinicalTrials.gov ↗

Not currently enrolling

This study is status unknown, as verified in Apr 2017. You cannot join it, but the record below documents what was studied.

Follow this study

Get an email when the registry record changes — status, dates, results — or when someone posts here.

Sign in to follow

Discussion

Questions and observations about this study, from anyone following it. Not medical advice, and not a channel to the study team — their contact details are on the registry record.

Sign in to join the discussion. Reading takes no account; posting does. You choose a display name, and a pseudonym is the default.

Nothing here yet. If you are running this trial, taking part in it, or weighing whether to, this is the place to say so.

Start the discussion