CClinicalTrials.gg
WithdrawnNCT02618252Updated Nov 12, 2025

Ultrasound vs Veinviewer in Patients With Difficulty IV Access

An interventional study of Zonare and Veinviewer in Vascular Access Complication, sponsored by University of Maryland, Baltimore. Withdrawn at 1 site in United States. Open to participants aged 18 Years and older. Per ClinicalTrials.gov, last updated 2025-11-12.

Sponsored by University of Maryland, Baltimore · Not applicable, Interventional, and Treatment

Why this study was withdrawn
We were not able to enroll participants
Phase
Not applicable
Study type
Interventional
Enrollment
0
Allocation
Randomized
Ages
18 Years and older
Sex
All
01

Study summary

Patients with difficulty intravenous access frequently have delay of care in emergency departments because Emergency Department (ED) personnel could not establish intravenous (IV) access for diagnostic blood test or treatment. The ultrasound machine or near-infrared devices have been used to improve this situation but no study has ever compared which machine is more efficient. This study is designed to investigate whether the ultrasound or Vein Viewer, which is a near-infrared device, is more efficient.

Read the detailed description

Intravenous (IV) access is important for patient care in emergency medicine as an estimate of 78% of ED patients would require more than 3 ED resources such as blood tests, medication, contrast, fluid. Care for patients with difficult intravenous access (DIVA) could be significantly delayed as it may take up to 120 minutes to establish IV access in patients with severe DIVA. Many solutions for DIVA had also been established to avoid central venous catheter insertion, including using ultrasound or near-infrared imaging systems for peripheral IV insertion.

Using ultrasound in the ED has been shown to decrease the rate of central venous catheters (CVC) insertion. However, the results from ultrasound-guided peripheral IV insertion (USGPIV) have been mixed. Among patients with DIVA, Costantino reported USGPIV required less time to successful first cannulation and fewer punctures comparing to traditional approach of landmark and palpation. However, other studies showed that USGPIV did not improve successful first attempts comparing to traditional IV insertion, and may have taken same or even longer time to successfully establish IV. USGPIV success rate requires more training for nurses and ED technicians as it is operator - dependent.

Patients have difficulty with IV access because their veins' clinical accessibility is low, for example, they are less visible or less palpable. The near-infrared imaging devices, such as Christie Digital's VeinViewer, improve this situation by using infra-red lights to make veins visible to the eyes.

Compared with routine IV insertion, near-Infra red imaging devices have been shown to increase first successful attempts and in less time in children with DIVA and improved visualization of peripheral veins. However, it did not show higher rate of successful attempts nor faster time in non-selected adults.

The efficacy of these near-infrared devices has not been established among adult patients with DIVA.

02

Conditions studied

  • Vascular Access Complication

Keywords

  • difficult IV access
  • ultrasound
  • veinviewer
  • near infrared device
03

In context

Lead sponsor

University of Maryland, Baltimore is the lead sponsor of 687 studies on the registry; 130 are open to participants now.

Of its 90 completed or terminated interventional studies of FDA-regulated products, 63 (70%) have results posted.

Counted across the registry records on this site, refreshed daily.

04

Who can participate

Ages eligible
18 Years and older
Sexes eligible
All
Accepts healthy volunteers
No

Inclusion criteria

  • Patients who fail inspections for visible or palpable veins or
  • Patients who request Ultrasound guided peripheral IV (USGPIV)
  • patients who are oriented to self (correct last name, first name), place (correct name of hospital), time (correct day of week or month of year) and person (correct name of current president)

Exclusion criteria

Exclusion Criteria:

  • Patients \< 18 years of age
  • Patients with hemodynamically instability requiring rapid central access.
  • Patients with impaired cognition and not able to consent, these patients are :

    • Clinically intoxicated patients, as defined by primary team.
    • Patients who family reported as "confused", "confusion", "altered mental status."
    • Patients who is not oriented x 4 as above
  • Patients who do not speak English.
05

Study design

Phase
Not applicable
Primary purpose
Treatment
Allocation
Randomized
Intervention model
Parallel assignment
Masking
None (open label)
Enrollment
0 participants (actual)

Study arms

  • Experimental
    Zonare

    108 patients are randomized to receive the intervention of using ultrasound machine (Zonare ZS3 machine) for IV cannulation. These patients will first undergo IV cannulation with assistance of the ultrasound machine.

    Device: Zonare

  • Experimental
    Veinviewer

    108 Patients are randomized to receive the Intervention of using the Veinviewer Flex machine for IV cannulation. These patients will first undergo IV cannulation with assistance of the Veinviewer Flex machine.

    Device: Veinviewer

Interventions

  • DeviceZonare

    Patients with difficulty IV access are randomized to receive either intervention with ultrasound machine (Zonare ZS3 machine) or the Veinviewer Flex machine.

  • DeviceVeinviewer

    Patients with difficulty IV access are randomized to receive either intervention with ultrasound machine (Zonare ZS3 machine) or the Veinviewer Flex machine.

06

What researchers measure

Primary outcomes

  1. Operator's time

    time from equipment-in-room to successful aspiration of 3ml of blood

    Time frame: up to 40 minutes

Secondary outcomes

  1. Number of first successful attempts

    operators have up to 40 minutes or 3 attempts.

    Time frame: 40 minutes

  2. Number of failures

    operators have up to 40 minutes or 3 attempts prior to patients crossing over or requiring a rescue modality

    Time frame: 40 minutes

  3. IV size

    operators have up to 40 minutes or 3 attempts to establish IV from 18 to 24 gauge

    Time frame: 40 minutes

  4. Patient satisfaction

    after completion of IV cannulation

    Time frame: up to 40 minutes

  5. Patient's perception of pain

    after completion of IV cannulation

    Time frame: up to 40 minutes

  6. ED length of stay

    Length of stay for discharged patients.

    Time frame: 24 hours

  7. hospital length of stay for admitted patient

    Length of stay for admitted patients

    Time frame: 30 days

  8. Cannulation time

    time from applying tourniquet to successful aspiration of 3ml of blood.

    Time frame: 40 minutes

  9. Number of failure to cannulate

    operators have up to 40 minutes or 3 attempts.

    Time frame: 40 minutes

07

Study locations

1 site
  • University of Maryland Medical Center
    Baltimore, Maryland 21201, United States
08

References and documents

Publications

  • Tanabe P, Gimbel R, Yarnold PR, Adams JG. The Emergency Severity Index (version 3) 5-level triage system scores predict ED resource consumption. J Emerg Nurs. 2004 Feb;30(1):22-9. doi: 10.1016/j.jen.2003.11.004. PubMed 14765078 ↗
  • Witting MD. IV access difficulty: incidence and delays in an urban emergency department. J Emerg Med. 2012 Apr;42(4):483-7. doi: 10.1016/j.jemermed.2011.07.030. Epub 2011 Dec 2. PubMed 22137793 ↗
  • Bauman M, Braude D, Crandall C. Ultrasound-guidance vs. standard technique in difficult vascular access patients by ED technicians. Am J Emerg Med. 2009 Feb;27(2):135-40. doi: 10.1016/j.ajem.2008.02.005. PubMed 19371518 ↗
  • Maiocco G, Coole C. Use of ultrasound guidance for peripheral intravenous placement in difficult-to-access patients: advancing practice with evidence. J Nurs Care Qual. 2012 Jan-Mar;27(1):51-5. doi: 10.1097/NCQ.0b013e31822b4537. PubMed 21826027 ↗
  • Teismann NA, Knight RS, Rehrer M, Shah S, Nagdev A, Stone M. The ultrasound-guided "peripheral IJ": internal jugular vein catheterization using a standard intravenous catheter. J Emerg Med. 2013 Jan;44(1):150-4. doi: 10.1016/j.jemermed.2012.02.044. Epub 2012 May 11. PubMed 22579025 ↗
  • Weiner SG, Sarff AR, Esener DE, Shroff SD, Budhram GR, Switkowski KM, Mostofi MB, Barus RW, Coute RA, Darvish AH. Single-operator ultrasound-guided intravenous line placement by emergency nurses reduces the need for physician intervention in patients with difficult-to-establish intravenous access. J Emerg Med. 2013 Mar;44(3):653-60. doi: 10.1016/j.jemermed.2012.08.021. Epub 2012 Oct 25. PubMed 23103067 ↗
  • de Graaff JC, Cuper NJ, Mungra RA, Vlaardingerbroek K, Numan SC, Kalkman CJ. Near-infrared light to aid peripheral intravenous cannulation in children: a cluster randomised clinical trial of three devices. Anaesthesia. 2013 Aug;68(8):835-45. doi: 10.1111/anae.12294. Epub 2013 Jun 14. PubMed 23763614 ↗
  • Shokoohi H, Boniface K, McCarthy M, Khedir Al-tiae T, Sattarian M, Ding R, Liu YT, Pourmand A, Schoenfeld E, Scott J, Shesser R, Yadav K. Ultrasound-guided peripheral intravenous access program is associated with a marked reduction in central venous catheter use in noncritically ill emergency department patients. Ann Emerg Med. 2013 Feb;61(2):198-203. doi: 10.1016/j.annemergmed.2012.09.016. Epub 2012 Nov 7. PubMed 23141920 ↗
  • Au AK, Rotte MJ, Grzybowski RJ, Ku BS, Fields JM. Decrease in central venous catheter placement due to use of ultrasound guidance for peripheral intravenous catheters. Am J Emerg Med. 2012 Nov;30(9):1950-4. doi: 10.1016/j.ajem.2012.04.016. Epub 2012 Jul 15. PubMed 22795988 ↗
  • Costantino TG, Parikh AK, Satz WA, Fojtik JP. Ultrasonography-guided peripheral intravenous access versus traditional approaches in patients with difficult intravenous access. Ann Emerg Med. 2005 Nov;46(5):456-61. doi: 10.1016/j.annemergmed.2004.12.026. PubMed 16271677 ↗
  • Stein J, George B, River G, Hebig A, McDermott D. Ultrasonographically guided peripheral intravenous cannulation in emergency department patients with difficult intravenous access: a randomized trial. Ann Emerg Med. 2009 Jul;54(1):33-40. doi: 10.1016/j.annemergmed.2008.07.048. Epub 2008 Sep 27. PubMed 18824276 ↗
  • Liu YT, Alsaawi A, Bjornsson HM. Ultrasound-guided peripheral venous access: a systematic review of randomized-controlled trials. Eur J Emerg Med. 2014 Feb;21(1):18-23. doi: 10.1097/MEJ.0b013e328363bebc. PubMed 23880981 ↗
  • Witting MD, Schenkel SM, Lawner BJ, Euerle BD. Effects of vein width and depth on ultrasound-guided peripheral intravenous success rates. J Emerg Med. 2010 Jul;39(1):70-5. doi: 10.1016/j.jemermed.2009.01.003. Epub 2009 Mar 9. PubMed 19272730 ↗
  • Sebbane M, Claret PG, Lefebvre S, Mercier G, Rubenovitch J, Jreige R, Eledjam JJ, de La Coussaye JE. Predicting peripheral venous access difficulty in the emergency department using body mass index and a clinical evaluation of venous accessibility. J Emerg Med. 2013 Feb;44(2):299-305. doi: 10.1016/j.jemermed.2012.07.051. Epub 2012 Sep 13. PubMed 22981661 ↗
  • Hess HA. A biomedical device to improve pediatric vascular access success. Pediatr Nurs. 2010 Sep-Oct;36(5):259-63. PubMed 21067078 ↗
  • Kim MJ, Park JM, Rhee N, Je SM, Hong SH, Lee YM, Chung SP, Kim SH. Efficacy of VeinViewer in pediatric peripheral intravenous access: a randomized controlled trial. Eur J Pediatr. 2012 Jul;171(7):1121-5. doi: 10.1007/s00431-012-1713-9. Epub 2012 Mar 14. PubMed 22415409 ↗
  • Sun CY, Lee KC, Lin IH, Wu CL, Huang HP, Lin YY, Hsu YF, Yu HR. Near-infrared light device can improve intravenous cannulation in critically ill children. Pediatr Neonatol. 2013 Jun;54(3):194-7. doi: 10.1016/j.pedneo.2012.12.012. Epub 2013 Feb 1. PubMed 23597539 ↗
  • Aulagnier J, Hoc C, Mathieu E, Dreyfus JF, Fischler M, Le Guen M. Efficacy of AccuVein to facilitate peripheral intravenous placement in adults presenting to an emergency department: a randomized clinical trial. Acad Emerg Med. 2014 Aug;21(8):858-63. doi: 10.1111/acem.12437. PubMed 25176152 ↗
  • Fields JM, Piela NE, Au AK, Ku BS. Risk factors associated with difficult venous access in adult ED patients. Am J Emerg Med. 2014 Oct;32(10):1179-82. doi: 10.1016/j.ajem.2014.07.008. Epub 2014 Jul 30. PubMed 25171796 ↗

Individual participant data

Plan to share: No

09

Updates

Tracking since Sep 25, 2026
No changes since tracking began. The registry record was last updated on Nov 12, 2025, before this site started recording changes on Sep 25, 2026. Its history is on ClinicalTrials.gov ↗
10

Registry details

Key details

Study ID
NCT02618252
Lead sponsor
University of Maryland, Baltimore
Responsible party
Quincy Tran (Assosciate Professor, University of Maryland, Baltimore) — Principal investigator
First posted
Dec 1, 2015
Start date
Aug 1, 2016
Primary completion
May 5, 2025
Completion
May 5, 2025
Last update
Nov 12, 2025

Study contacts

Quincy Tran, MD, PhD
principal investigator · University of Maryland

Oversight

Data monitoring committee
No
FDA-regulated drug
No
FDA-regulated device
Yes
View the source record on ClinicalTrials.gov ↗

Not currently enrolling

This study is withdrawn, as verified in Nov 2025. You cannot join it, but the record below documents what was studied.

Follow this study

Get an email when the registry record changes — status, dates, results — or when someone posts here.

Sign in to follow

Discussion

Questions and observations about this study, from anyone following it. Not medical advice, and not a channel to the study team — their contact details are on the registry record.

Sign in to join the discussion. Reading takes no account; posting does. You choose a display name, and a pseudonym is the default.

Nothing here yet. If you are running this trial, taking part in it, or weighing whether to, this is the place to say so.

Start the discussion