An interventional study of ADM X3-MoP Cup and CoC Cup in Arthroplasties, Hip Replacement, sponsored by University of Aarhus. Enrolling by invitation at 1 site in Denmark. Open to participants aged 40 Years to 65 Years. Per ClinicalTrials.gov, last updated 2026-11-06.
Sponsored by University of Aarhus · Not applicable, Interventional, and Treatment
Help build ClinicalTrials.gg — short surveys, remote interviews or testing, in your language. Take part →
A Single-Center Randomized, Patient-Blinded, Prospective Five-Year Study to Compare the Functional Results after Insertion of ADM X3-MoP Cup (Stryker) and a CoC Cup (Zimmer) in Primary THA. 60 patients will be enrolled during a 2 year period. At surgery tantalum beads will be inserted into predrilled holes of the polyethylene rim for assessment of motion of the large mobile poly in the ADM Trident Cup by use of RSA. Patients will be followed by functional examinations as well as PROM assessment.
With Metal-on-Metal (MoM) articulations leaving the marked the THA bearing choice for younger patients is currently debated and overall the choice stands between CoC and MoP. New HXLPE is wear-resistant and safe and clinical HXLPE wear (RSA) hardly exceed the wear measured in retrieval CoC implants. For CoC articulations stripe wear on edge loading is a reported problem leading to increased wear in examined retrieval components and CoC wear is dependent on component position. Although the risk is very small, CoC bearings are at still at risk of fracture, and functional squeaking is a complication that adversely affects the quality of life in about 1% of CoC THA patient. Dual mobility MoP cups were designed for reducing hip dislocations in older patients treated with THA after medial hip fractures. The concept provides good stability and mobility and may also be an optimal solution for younger and active patients; however, dual mobility MoP has not previously been documented for use in younger patients. The anatomical dual mobility (ADM) cup design (Stryker) is soft tissue sparing (iliopsoas tendon) potentially leading to lesser groin-pain and squeaking is not a concern. It is currently unknown if the outer-articulation of the dual mobility PE liner keeps moving over time or could impinge in the joint capsule in an undesirable position and result in unwanted edge loading and higher wear-rates. Metal ions are produced even in MoP bearings and even though in dual-articulation MoP bearings most (90%) of the motion is believed to occur between the head and liner (ceramic-polyenthylene), the metal ion levels may be higher than expected for MoP hips (large poly contact in metal shell), while expectedly there will be no metal ions in CoC THA.
University of Aarhus is the lead sponsor of 1,303 studies on the registry; 190 are open to participants now.
Counted across the registry records on this site, refreshed daily.
Go through the criteria one by one — yes, no or not sure — and take the list to your doctor or the study team. Kept in this browser only.
Exclusion Criteria:
Underlined terms in the criteria open these too. Explained by clinicaltrials.gg, not part of the registry record. The study team decides who can take part.
Cancer that has spread from where it began to other parts of the body. “Metastatic” cancer is cancer that has spread this way.
Metastases
Cancer that has spread from where it began to other parts of the body. “Metastatic” cancer is cancer that has spread this way.
Explained by clinicaltrials.gg, not part of the registry record. The study team decides who can take part.
THA: ADM dual-mobility hydroxyapatite coated cups with X3TM HXLPE liners on 28mm BIOLOX® delta femoral heads (Stryker) with femoral stems being 2nd generation Accolade stems of the taper lock type, proximal circumferential coated with a 50µm plasma-spray PureFix HA coating to aid the mechanical engagement in bone coating (Stryker)
Device: ADM X3-MoP Cup
THA: CoC BIOLOX® delta-delta large-head single-mobility cementless fiber-mesh titanium coated acetabular system from Zimmer (Zimmer TrilogyIT cup/CLS spotorno stem) with a grit-blasted osteophilic titanium alloy CLS® Spotorno femoral stems (Zimmer) that has a three-dimensional wedge shape and sharpened ribs in the proximal region
Device: CoC Cup
Motion analysis (accelerometer (Ax3 Axivity) based activity monitoring)
For all participants: Inertia sensors are a new technology for patient motion analysis which allows simple and fast routine clinical movement analysis and long-term activity monitoring. We will employ the newest generation of accelerometer (Ax3 Axivity) based activity monitoring (small, light, low cost, validated for orthopaedic patients also with walking aids) to count, in real life, the number of events and the duration of postures and activities. Further muscle power investigations such as by use of the legg extension power rig will be used.
Time frame: 5 year
questionnaires ("the Harris Hip Score" (HHS), the Oxford Hip Score (OHS), the HOOS score, satisfaction, dislocation, and revisions)
For all participants: Pre- and postoperative clinical evaluations will be made according to "the Harris Hip Score" (HHS), the Oxford Hip Score (OHS), the HOOS score, and satisfaction, dislocations and revisions will be noted. Moreover, pre-operative rest and motion pains will be assessed by visual analogue scale scores (VAS).
Time frame: 5 year
Radiography (implant migration and wear)
For all participants: Within a week following surgery a stereo x-ray is performed and this functions as the baseline for future follow-up (in this study at 1 year, 2 years and 5 years). When comparing all stereo x-rays in a patient series, implant migration with respect to a set of bone markers can be calculated in three dimensions as a function of time - similarly wear of the implant surfaces can be evaluated.Fluoroscopic stereoradiometric recordings (Dynamic RSA) can be used to assess the functional motion of implants at desired motion speeds. In this study we record the liner motion of the ADM cup with the patients in different positions that in theory stresses the motion of the liner into new positions at edge-motions. The purpose is to gain knowledge on the safety function of the implant in vivo - if the liner moves and if it positions safely like it is supposed to.
Time frame: 5 year
The record gives a start of Nov 2014, a primary completion of Jun 2027 and a completion of Nov 2027. It does not say whether these dates are actual or estimated.
Primary completion moved once since we started tracking on Sep 25, 2026: Jun 2026 → Jun 2027, on Nov 6, 2026.
Earlier changes are on the record history on ClinicalTrials.gov ↗
How these figures are worked out, and which studies are left out of them.
From the registry record's own update history. This site started tracking changes on Sep 25, 2026; for anything earlier, see the record history on ClinicalTrials.gov ↗
Eligibility is decided by the study team. Share this record with your doctor or contact the team directly.
No contact was published for this record. The registry link below has the sponsor’s details.
Get an email when the registry record changes — status, dates, results — or when someone posts here.
Sign in to followQuestions and observations about this study, from anyone following it. Not medical advice, and not a channel to the study team — their contact details are on the registry record.
Sign in to join the discussion. Reading takes no account; posting does. You choose a display name, and a pseudonym is the default.
Nothing here yet. If you are running this trial, taking part in it, or weighing whether to, this is the place to say so.