An observational study in Oral Tumors, sponsored by M.D. Anderson Cancer Center. Completed at 1 site in United States. Open to participants aged 18 Years and older. Per ClinicalTrials.gov, last updated 2017-10-20.
Sponsored by M.D. Anderson Cancer Center · Observational
The goal of this clinical research study is to evaluate an imaging technology that may help clinicians see how far an area of pre-cancerous or cancerous tissue extends in the mouth.
Fluorescence and Reflectance:
All tissue and cells are made up of tiny particles that give off small amounts of light. This light is called fluorescence. Cancerous cells and normal cells give off different amounts and types of fluorescence and also reflect (bounce back) light differently. Researchers want to better understand if fluorescence and reflectance from mouth tissue can be used to tell which cells are abnormal. This information may help doctors detect early mouth cancers and treat all areas affected by cancerous changes.
The MDM Instrument, FastEEM4 Instrument, POS Instrument, PS2 Instrument, and the IMS Instrument:
Five (5) instruments have been developed:
The MDM system is a modified standard medical microscope similar to what doctors use to examine people's ears. A special light source has been attached to this microscope to provide different colors of light that can shine in the mouth. This microscope also has a digital camera attached to it so that researchers can take pictures of fluorescence and reflectance in the mouth in order to record what is seen with the different light colors. Researchers want to study the pictures in order to better understand the differences in fluorescence and reflectance from normal and abnormal cells.
The PS2 is an imaging device for examining the mouth without touching the mouth. The PS2 uses a blue light source in fluorescence mode. The light passes through a filter and shines on the tissue area. A filter is placed in the path to collect only the fluorescent light given off from the tissue. In reflectance mode, a white light is used. Images are collected using a device and a laptop with a software interface. A set of fluorescence and reflectance images can be taken in less than a minute.
The IMS is also an imaging device for examining the mouth without touching the mouth. The IMS includes white and blue light, a camera lens, customized optics (mirror, prisms, and lenses), a filter, a camera, and a computer. In reflectance mode, a white light shines on the tissue area, and specialized optics put the data on the camera. In fluorescence mode, the blue light highlights the tissue. A filter blocks the blue light, which allows tissue fluorescence to be seen. The IMS uses the same light sources as the PS2.
The FastEEM4 system (nonstandard imaging technology) has a probe (a small device used for measuring and/or detecting) that is about the size of a pencil. The probe is placed gently against the mucosa, and different colors of light are directed through the probe to a small area (the lesion and the normal-appearing area) of mouth tissue. Then the fluorescence and reflectance is recorded by a computer.
The POS instrument will direct different colors of light through fibers to the lining of the mouth and then light is collected and sent to a special camera and a computer to be analyzed. The spectroscopy system has a small probe about the size of a writing pen which is placed gently against the lining of the mouth. The exposed tissues will give off very small amounts of fluorescence. This light cannot be seen by the eye, but is seen by a computer.
Use of the MDM, PS2, or IMS Instruments:
If you agree to take part in this study, a clinician may first use the MDM, PS2, or IMSsystem. If one of these systems are used, the clinician will examine the inside of your mouth with a gloved finger while using standard white light or one or more of the imaging systems for viewing. The instrument will then take pictures of abnormal-appearing and normal-appearing areas in the mouth. The edge between these areas will then be marked with a surgical pen to outline the border between the abnormal-appearing tissue and normal-appearing tissue to be seen on a digital photo. Imaging with each device will take about 2 minutes or less. Between each use of the instrument, it will be sterilized according to standard practices.
Use of the FastEEM4 and/or POS Instruments:
The clinician may then use the FastEEM4 and/or the POS systems. If the FastEEM4 and/or POS systems are used, you will have a FastEEM4 and/or POS probe(s) placed gently on the mouth lesion(s). Several measurements will then be taken by moving the probe(s) a short distance at a time, toward the edge of the lesion(s), until it measures what appears to be normal mouth tissue.
Biopsies and Tissue Removal:
You may be having surgery to remove abnormal-appearing mouth lesions as part of standard care, so the study biopsies and tissue removal may be done at the same time as your surgery. After the surgeon has finished surgery and removed tissue from your mouth as part of your standard treatment, a portion of tissue (from both the abnormal-appearing and normal-appearing areas) that was already removed by the surgeon may be separated out from the main tissue specimen and separately evaluated. This is done so that the researchers can better compare the appearance and diagnosis at these sites to the images that were taken. In addition, a biopsy may be taken from the area of normal-appearing tissue from the opposite side of the mouth that was imaged with the FastEEM4 and/or POS probe(s), if the FastEEM4 and/or POS system(s) were used. If it is performed, this one biopsy of normal appearing tissue will be in addition to what is removed for standard care.
If this biopsy is performed, a small sample (4 mm, about the size of a small pencil eraser) of the lining of your mouth will be removed, while you are asleep under general anesthesia, from the area of normal-appearing tissue from the opposite side of the mouth that was imaged by both instruments.
Length of Study:
You will not be told of any experimental findings of this study. Information about the diagnosis will be available to your treating doctor. After tissue collection is complete, your participation in this study will be over.
All data (such as the tissue images and pathologic diagnosis) will be coded with a number instead of your personal identifying information (such as your name or medical record number) to help ensure your privacy.
This is an investigational study. Up to 60 patients will take part in this study. All will be enrolled at MD Anderson.
377 studies on the registry are indexed under Mouth Neoplasms; 126 are open to participants now.
This study's enrollment of 58 is below the median of 90 across 103 observational studies indexed under Mouth Neoplasms.
Browse Mouth Neoplasms studies →M.D. Anderson Cancer Center is the lead sponsor of 2,999 studies on the registry; 581 are open to participants now.
Of its 599 completed or terminated interventional studies of FDA-regulated products, 402 (67%) have results posted.
Counted across the registry records on this site, refreshed daily.
Participants with precancerous or cancerous oral lesions.
Exclusion Criteria:
Multispectral digital microscope (MDM) + FastEEM4 Systems
Device: FastEEM4 System · Device: Multispectral Digital Microscope
The FastEEM4 probe is moved toward the edge of the lesion(s) until it measures what appears to be normal mouth tissue.
The MDM instrument will take pictures of abnormal-appearing and normal-appearing areas in the mouth.
Also known as: MDM
Feasibility of using optical imaging and spectroscopy to assist in margin detection for tumor resection in the oral cavity.
Time frame: 3 Years
This study is completed, as verified in Oct 2017. You cannot join it, but the record below documents what was studied.
Get an email when the registry record changes — status, dates, results — or when someone posts here.
Sign in to followQuestions and observations about this study, from anyone following it. Not medical advice, and not a channel to the study team — their contact details are on the registry record.
Sign in to join the discussion. Reading takes no account; posting does. You choose a display name, and a pseudonym is the default.
Nothing here yet. If you are running this trial, taking part in it, or weighing whether to, this is the place to say so.
M.D. Anderson Cancer Center